• Title/Summary/Keyword: Gamma Detection

Search Result 542, Processing Time 0.023 seconds

Analysis of Flavor Composition of Coriander Seeds by Headspace Mulberry Paper Bag Micro-Solid Phase Extraction

  • Cha, Eun-Ju;Won, Mi-Mi;Lee, Dong-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.11
    • /
    • pp.2675-2679
    • /
    • 2009
  • This paper reports the example of headspace mulberry paper bag micro solid phase extraction (HS-MPB-$\mu$-SPE) as a new sampling method for the determination of volatile flavor composition of coriander seeds. Adsorption efficiencies between two configurations of mulberry paper bag were compared, and several parameters affecting the HS-MPB-$\mu$-SPE were investigated and optimized. The optimized technique uses an adsorbent (Tenax TA, 0.1 mg) contained in a mulberry paper bag of front configuration where fine surface was outside, and minimal amount of organic solvent (0.6 mL). Linalool and $\gamma$-terpinene were found as abundant flavor compounds from coriander seeds. The limit of detection (LOD) and the limit of quantitation (LOQ) for linalool of major flavor in coriander seeds were 10.3 ng/mL and 34.4 ng/mL, respectively. The proposed method showed good reproducibility and good recovery. The HS-MPB-$\mu$-SPE is very simple to use, inexpensive, requires small sample amounts and solvent consumption. Because the solvent for extraction is reduced to only a very small volume, there is minimal waste or exposure to toxic organic solvent and no further concentration step.

Identification of Irradiated Granule-Type Ramen Soup Powder by Pulsed Photostimulated Luminescence and Thermoluminescence during Storage

  • Yi, Sang-Duk;Yang, Jae-Seung;Kim, Dong-Woo;Shin, Doo-Ho;Jo, Gab-Yeon;Chang, Kyu-Seob;Oh, Man-Jin
    • Preventive Nutrition and Food Science
    • /
    • v.8 no.1
    • /
    • pp.79-84
    • /
    • 2003
  • This study was carried out to establish a method for determining if granule-type Ramen soup powder has been irradiated. Thermoluminescence (TL) and pulled photostimulated luminescence (PPSL) were used as the detection methods through observed changes of TL and PPSL intensities after storage under differing conditions. PPSL intensities increased with increases in irradiation doses. The threshold level of PPSL was below 412$\pm$58 photon counts regardless of storage conditions (room and darkroom) after 10 months. TL intensities also increased with increasing irradiation doses. The coefficients ($R^2$) of PPSL (0.74~0.94) and TL intensities (0.92~0.58) were very highly correlated with irradiation dose. The PPSL and TL intensities were decreased after 10 months of storage. These results indicate that discrimination of irradiated from non-irradiated granule-type Ramen soup powder is possible using TL and PPSL methods despite the decrease in intensities of TL and PPSL with increasing storage times.

The Electrical and Radiation Detection Properties of $Au/Cd_{1-x}Zn_x/Te(x=20%)/Au$ Structure ($Au/Cd_{1-x}Zn_x/Te(x=20%)/Au$ 구조의 전기적 특성 및 방사선 탐지 특성)

  • 최명진;왕진석
    • Electrical & Electronic Materials
    • /
    • v.10 no.1
    • /
    • pp.39-44
    • /
    • 1997
  • Bulk type radiation detector of Au/Cd$_{1-x}$ Zn$_{x}$Te(x=20%)/Au structure using Cd$_{1-x}$ Zn$_{x}$Te(x=20%) wafer(3x4xl mm$^{3}$) grown by high pressure Bridgman method has been developed. We etched wafer surfaces with 2% Br-methanol solution and coated gold thin film on the surfaces by electroless deposition method for 5 min. in 49/o HAuCI$_{3}$ 4H20 solution. Initial etch rates of Cd, Zn and Te were 46%, 12% and 42% respectively. After etched, the surface of wafer was slightly revealed to Te rich condition. The leakage current was increased with etch time, but it didn't exceed 3nA at 50volt. The thickness of Au film was about 100nm by Rutherford Backscattering Spectroscopy(RBS). The resolution were 6.7% for 22.1 keV photon from 109 $^{109}$ Cd and 8.2% for 59.5 keV photon from $^{241}$ Am. The radiation detector such as Au/Cd$_{1-x}$ Zn$_{x}$Te(x=20%)/Au structure was more effective to monitor the low energy gamma radiation.iation.

  • PDF

Crystal growth and scintillation properties of CsI:Na (CsI:Na 결정 육성과 섬광 특성)

  • Cheon, Jong-Kyu;Kim, Sung-Hwan;Kim, H.J.
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.443-448
    • /
    • 2010
  • In this work, the scintillation properties of CsI:Na crystal were investigated as radiation detection sensor. This scintillation material was grown by a 2-zone vertical Bridgman method. Under X-ray excitation the crystal shows a broad emission band between 280 nm and 690 nm wavelength range, peaking at 413 nm. Energy resolution for $^{137}Cs$ 662 keV $\gamma$-rays of the crystal was measured to be 6.9 %(FWHM). At room temperature, the crystal exhibits three exponential decay time components. The fast and major component of scintillation time profile of the crystal emission decays with a 457 ns time constant. Absolute light yield of the crystal was estimated to be 53,000 ph/MeV using LAAPD. The sample crystal shows proportionality of 30 % in the measured energy range from 31 to 1,333 keV. And the $\alpha/\beta$ ratio of the crystal was 0.14.

Lymphoscintigraphy for Intraopertive Sentinel Node Biopsy of Skin and Soft Tissue Malignancy (Lymphoscintigraphy와 전초 림프절 절제술을 이용한 피부 악성종양의 치험례)

  • Lee, Tae Hoon;Shim, Jeong Su;Jeong, Jae Ho
    • Archives of Plastic Surgery
    • /
    • v.32 no.5
    • /
    • pp.635-640
    • /
    • 2005
  • Sentinel lymphnode biopsy is widely performed in the management of malignant melanoma and breast cancer. The sentinel lymphnode is the prime site of draining from the malignant lesion and of metastasis. The aim of this study was to evaluate a usefulness of lymphoscintigraphy in conjunction with a removal of sentinel lymphnodes of skin and soft tissue malignancy. We studied 11 patients selected between January, 2003 and November, 2004. Clinically sentinel lymphnodes free of metastasis were examined with lymphoscintigraphy, gamma detection probe and vital dye staining, and we reviewed histopathologic findings and inert status of the nodes and the results fo treatment. Nine cases were malignant melanoma, one was squamous cell carcinoma on the left hand and another one leiomyosarcoma. Sentinel lymphnodes were identified in all cases. Three cases of malignant melanoma had positive sentinel lymphnodes on histological examination. All patients with positive sentinel lymphnodes were treated with therapeutic regional lymphadectomy, chemotherapy and adjuvant regimen. Four patients underwent PET scanning and followed sentinel lymphnode biopsy. Two had no metastasis signs on PET scanning. Therapeutic lymphnode dissection was carried out upon the patients whose sentinel lymphnode was positive on PET scanning. We contend that lymphoscintigraphy and sentinel lymphnode biopsy are reliable to confirm regional lymphnode metastasis of the skin and soft tissue malignancy, and blind extensive lymphnode dissection can be spared.

Identification of the associations between genes and quantitative traits using entropy-based kernel density estimation

  • Yee, Jaeyong;Park, Taesung;Park, Mira
    • Genomics & Informatics
    • /
    • v.20 no.2
    • /
    • pp.17.1-17.11
    • /
    • 2022
  • Genetic associations have been quantified using a number of statistical measures. Entropy-based mutual information may be one of the more direct ways of estimating the association, in the sense that it does not depend on the parametrization. For this purpose, both the entropy and conditional entropy of the phenotype distribution should be obtained. Quantitative traits, however, do not usually allow an exact evaluation of entropy. The estimation of entropy needs a probability density function, which can be approximated by kernel density estimation. We have investigated the proper sequence of procedures for combining the kernel density estimation and entropy estimation with a probability density function in order to calculate mutual information. Genotypes and their interactions were constructed to set the conditions for conditional entropy. Extensive simulation data created using three types of generating functions were analyzed using two different kernels as well as two types of multifactor dimensionality reduction and another probability density approximation method called m-spacing. The statistical power in terms of correct detection rates was compared. Using kernels was found to be most useful when the trait distributions were more complex than simple normal or gamma distributions. A full-scale genomic dataset was explored to identify associations using the 2-h oral glucose tolerance test results and γ-glutamyl transpeptidase levels as phenotypes. Clearly distinguishable single-nucleotide polymorphisms (SNPs) and interacting SNP pairs associated with these phenotypes were found and listed with empirical p-values.

A Study on the Screening of the Novel Genes Associated with Lysosomal Trafficking and Mutation Detection in Fibroblasts of the Patients with Mucolipidosis type II and III (리소좀 교통 이상을 초래하는 뮤코지방증 2형과 3형 환자의 섬유아세포를 이용한 신규 유전자 탐색 및 돌연변이에 대한 연구)

  • Song, Seng Mi;Chang, Soo Hee;Paik, Kyung Hoon;Jin, Dong-Kyu
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.5 no.1
    • /
    • pp.65-75
    • /
    • 2005
  • Purpose: To understand genetic differences and similarities between mucolipidosis and control. Methods: Using the fibroblast of the mucolipidosis II and control, forward and reverse subtracted libraries were constructed. Among these clones, we investigated mutations in the GNPTA (MGC4170) gene, which codes for the ${\alpha}/{\beta}$ subunits of phosphotransferase, and in the GNPTAG gene, which codes for the ${\gamma}$ subunits in 5 Korean patients with mucolipidosis type II or IIIA. Result: Several differentially expressed cDNAs were cloned and their sequences were determined. Mutation analysis of the interested gene, GNPTA was performed and we identified 7 mutations in the GNPTA gene, but none in the GNPTAG gene. The mutations in type II patients included p.Q104X(c.310C>T), p.R1189X(c.3565C>T), p.S1058X(c.3173C>G), p.W894X(c.2681G>A) and p.H1158fsX15(c.3474_3475delTA), all of which are non-sense or frame shift mutations. However, a splicing site mutation, IVS13+1G>A (c.2715+1G>A) was detected along with a non-sense or a frame shift mutation (p.R1189X or p.E858fsX3(c.2574_2575delGA)) in two mucolipidosis type IIIA patients. Conclusion: This report shows that mutations in the GNPTA gene coding for the ${\alpha}{\beta}$subunits of phosphotransferase, and not mutations in the GNPTAG gene, account for most of mutations found in Korean patients with mucolipidosis type II or IIIA.

  • PDF

The development of conductive 10B thin film for neutron monitoring (중성자 모니터링을 위한 전도성 10B 박막 개발)

  • Lim, Chang Hwy;Kim, Jongyul;Lee, Suhyun;Jung, Yongju;Choi, Young-Hyun;Baek, Cheol-Ha;Moon, Myung-Kook
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.199-205
    • /
    • 2014
  • In the field of neutron detections, $^3He$ gas, the so-called "the gold standard," is the most widely used material for neutron detections because of its high efficiency in neutron capturing. However, from variable causes since early 2009, $^3He$ is being depleted, which has maintained an upward pressure on its cost. For this reason, the demands for $^3He$ replacements are rising sharply. Research into neutron converting materials, which has not been used well due to a neutron detection efficiency lower than the efficiency of $^3He$, although it can be chosen for use in a neutron detector, has been highlighted again. $^{10}B$, which is one of the $^3He$ replacements, such as $BF_3$, $^6Li$, $^{10}B$, $Gd_2O_2S$, is being researched by various detector development groups owing to a number of advantages such as easy gamma-ray discrimination, non-toxicity, low cost, etc. One of the possible techniques for the detection is an indirect neutron detection method measuring secondary radiation generated by interactions between neutrons and $^{10}B$. Because of the mean free path of alpha particle from interactions that are very short in a solid material, the thickness of $^{10}B$ should be thin. Therefore, to increase the neutron detection efficiency, it is important to make a $^{10}B$ thin film. In this study, we fabricated a $^{10}B$ thin film that is about 60 um in thickness for neutron detection using well-known technology for the manufacturing of a thin electrode for use in lithium ion batteries. In addition, by performing simple physical tests on the conductivity, dispersion, adhesion, and flexibility, we confirmed that the physical characteristics of the fabricated $^{10}B$ thin film are good. Using the fabricated $^{10}B$ thin film, we made a proportional counter for neutron monitoring and measured the neutron pulse height spectrum at a neutron facility at KAERI. Furthermore, we calculated using the Monte Carlo simulation the change of neutron detection efficiency according to the number of thin film layers. In conclusion, we suggest a fabrication method of a $^{10}B$ thin film using the technology used in making a thin electrode of lithium ion batteries and made the $^{10}B$ thin film for neutron detection using suggested method.

Assessment of Validity of RT-PCR and EIA for The Detection of Hepatitis C Virus Infection (C형 간염의 진단을 위한 역전사중합효소연쇄반응과 효소면역측정법의 타당성 평가)

  • Son, Byung-Chul;Chun, Jin-Ho;Park, Yeong-Hong;Shin, Hai-Rim;Cho, Kyu-Il;Kim, Jong-Han;Jung, Kui-Oak;Lee, Jong-Tae;Lee, Chae-Un;Paik, Nak-Whan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.2 s.50
    • /
    • pp.526-541
    • /
    • 1995
  • This study was conducted to estimate the validity of reverse transcriptase-polymerase chain reaction(RT-PCR) compared to enzyme immunoassay(EIA) for the detection of hepatitis C virus (HCV) infection. EIA for antibody to HCV(anti-HCV) and RT-PCR for HCV was executed on the subjects from Pusan and Kyungnam area with questionnaire survey to collect some relating factors of HCV infection. As the result from 617 cases, the prevalence of HCV infection was 1.5% by EIA and 3.7% by RT-PCR(p<0.05), and the age standardized rate was 1.7% and 3.4% by EIA and RT-PCR, respectively. The prevalence of hepatitis B surface antigen(HBsAg) was 6.8% by enzyme linked immunosorbent assay(ELISA) and the age standardized rate was 7.7%. It was the higher in male group comparing to female group(p<0.01). Both of the prevalence of HCV and HBsAg were higher in elevated asparate aminotransferase(AST) and alanine aminotransferase (ALT) group than in normal AST and ALT group(p<0.01). There was no specific risk factor of HCV infection. Though the degree of agreement of EIA and RT-PCR by gamma statistics was 97.2%, it showed a significant difference between the two methods(p<0.01). For the detection of HCV infection, positive predictive value of EIA was 66.7% and negative predictive value of EIA was 97.2%. This study suggests that negative result to anti-HCV by EIA didn't mean the free state of HCV infection, therefore it would be helpful that further monitoring for HCV infection by RT-PCR in the case of elevated AST and ALT and/or clinically suspected.

  • PDF

Optical Characterizations of TlBr Single Crystals for Radiation Detection Applications

  • Oh, Joon-Ho;Kim, Dong Jin;Kim, Han Soo;Lee, Seung Hee;Ha, Jang Ho
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.167-171
    • /
    • 2016
  • Background: TlBr is of considerable technological importance for radiation detection applications where detecting high-energy photons such as X-rays and ${\gamma}$-rays are of prime importance. However, there were few reports on investigating optical properties of TlBr itself for deeper understandings of this material and for making better radiation detection devices. Thus, in this paper, we report on the optical characterizations of TlBr single crystals. Spectroscopic ellipsometry (SE) and photoluminescence (PL) measurements at RT were performed for this work. Materials and Methods: A 2-inch TlBr single crystalline ingot was grown by using the vertical Bridgman furnace. SE measurements were performed at RT within the photon energy range from 1.1 to 6.5 eV. PL measurements were performed at RT by using a home-made PL system equipped with a 266 nm-laser and a spectrometer. Results and Discussion: Dielectric responses from SE analysis were shown to be slightly different among the different samples possibly due to the different structural/optical properties. Also from the PL measurements, it was observed that the peak intensities of the middle samples were significantly higher than those of the other two samples. With the given values for permittivity of free space (${\varepsilon}_0=8.854{\times}10^{-12}F{\cdot}m^{-1}$), thickness (d = 1 mm), and area ($A=10{\times}10mm^2$) of the TlBr sample, capacitances of TlBr were 6.9 pF (at $h{\nu}=3eV$) and 4.4 pF (at $h{\nu}=6eV$), respectively. Conclusion: SE and PL measurement and analysis were performed to characterize TlBr samples from the optical perspective. It was observed that dielectric responses of different TlBr samples were slightly different due to the different material properties. PL measurements showed that the middle sample exhibited much stronger PL emission peaks due to the better material quality. From the SE analysis, optical, dielectric constants were extracted, and calculated capacitances were in the few pF range.