• 제목/요약/키워드: Gamma Detection

검색결과 542건 처리시간 0.027초

Calculation of Effective Angular Correlation in the HPGe Spectroscopy of Co-60 $\gamma$-rays

  • Kim, In-Jung;Sun, Gwang-Min;Park, H. D.;Bae, Young-Dug
    • Nuclear Engineering and Technology
    • /
    • 제34권1호
    • /
    • pp.22-29
    • /
    • 2002
  • The angular correlation effect was investigated for Co-60 ${\gamma}$-ray spectroscopy by using HPGe detector and the effective angular correlation was theoretically calculated by considering the finite detector solid angle. For the calculation of effective angular correlation, the detection efficiency as a function of ${\gamma}$-ray incident direction was obtained by using Monte Carlo method and the first interaction model. The results and the methods used in the calculation are discussed.

천연우라늄 오염에 관한 방사선/능 측정기술 연구 (A Study on the Natural Uranium Contamination Measuring Technology)

  • 정운수;홍상범;서범경;박진호;조용우;조성원;이정민
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.407-417
    • /
    • 2004
  • 본 연구는 우라늄변환시설의 해체과정에서 발생되는 콘크리트 및 구성부품에 대한 알파분광과 감마분광에 대한 방사선계측방법의 타당성을 입증하고자 한다. 우라늄변환시설내의 구성부품 및 내부벽면은 천연우라늄 물질로 오염되어있다. 스테인레스 스틸 파이프와 벽면의 콘크리트의 일부에 대하여 시료를 채취하고 알파분석과 감마분석을 수행하였다. 천연우라늄 시료(AUC)의 측정에서 0.01 Bq/g 이상에서는 알파선 측정결과와 감마선 측정결과가 잘 일치하지만, 0.005 Bq/g의 낮은 농도에서는 감마선 측정결과가 상대적으로 높게 평가된다. 변환공정의 천연우라늄인 $^{238}U$$^{214}Pb$, $^{214}Bi$$^{234}Th$, $^{234m}Pa$을 비교 측정하여 그 농도를 구할 수 있다. 우라늄변환시설의 벽면은 대부분 우라늄으로 오염되어있다. 우라늄변환시설 해체과정에서 발생되는 배경방사능 준위의 폐기물을 감마분광법을 이용하여 계측하여 보수적인 평가 자료로 활용할 수 있다.

  • PDF

방사성 의약품 자동합성장치용 단채널 감마선 분광기 보드의 설계 및 제작 (Development of One-channel Gamma ray spectroscope for Automatic Radiopharmaceutical Synthesis System)

  • 송관훈;김광수
    • 전자공학회논문지
    • /
    • 제51권4호
    • /
    • pp.193-200
    • /
    • 2014
  • 본 논문에서는 방사성 의약품의 자동합성장치에 사용되는 단채널 감마선 분광기를 보드 형태로 설계, 제작하고 그 특성을 측정 분석하였다. 감마선 검출을 위해 CZT (CdZnTe) spear 검출기를 이용하였고 아날로그 방식을 적용한 신호처리 보드의 형태로 감마선 분광기를 제작하였다. 측정을 위하여 방사성 물질인 Co-60을 시료로 사용하였으며, 최대 1173keV까지의 감마선 에너지 스펙트럼을 얻을 수 있었다. 아날로그 보드는 CZT spear 검출기에서 감마선을 검출하여 출력하는 신호를 적절히 변화시켜주기 위한 SF (shaping filter) 및 PHA (peak and hold amplifier)와 수치화된 감마선 신호 데이터를 계산하기 위한 ADC(analog to digital converter)와 FPGA (field programmable gate array)로 구성되었다.

감마선 검출용 $HgI_2$ 소자 제작 및 특성 평가 (Fabrication and Test of a $HgI_2$ Gamma Ray Detector)

  • 최명진;이홍규;강영일;임호진;최승기
    • Journal of Radiation Protection and Research
    • /
    • 제16권2호
    • /
    • pp.1-6
    • /
    • 1991
  • 상온에서 사용할 수 있는 감마선 검출 소자로서 $HgI_2$ 소자의 응용성을 판단하기 위하여 기상 성장법으로 $HgI_2$ 단결정을 성장시켰고 이를 이용하여 검출 소자를 제작한 후 감마선 검출 특성을 조사하였다 성장된 단결정의 비저항과 전하 운반자 포획 밀도는 상온에서 각각 $10^{11}{\Omega}\;cm$$1.8{\times}10^{14}/cm^3$였으며 단결정의 Photoluminescence를 측정한 결과 성장된 $HgI_2$ 단결정의 밴드갭의 온도계수는 20K부터 77K에서 $-1.53{\times}10^{-4}eV/K$였다. 감마선 검출실험 결과 제작된 $HgI_2$ 검출 소자는 상온에서 우수한 계수 특성과 시간에 대한 선형적 축적 계수 특성을 나타내었으나 온도변화에 따라 계수의 특성의 변화는 심하였다.

  • PDF

충남지역(忠南地域) 논토양중 유기염소계(有機鹽素系) 농약(農藥)의 잔류수준(殘留水準) (Residue Levels of Organochlorine Pesticides on Paddy Field Soils in the Chungnam Area)

  • 최종우;이규승;이중길;노길봉
    • 한국환경농학회지
    • /
    • 제6권2호
    • /
    • pp.12-21
    • /
    • 1987
  • 1986.3.20∼4.6 사이에 충남(忠南)의 대덕(大德), 공주(公州), 금산(錦山), 논산(論山) 및 연기군(燕岐郡) 등 5개 지역(地域)에서 총(總) 108점(點)의 논토양을 채취하여 19종(種), 유기염소계(有機鹽素系) 농약(農藥)을 대상으로 잔류수준(殘留水準)을 조사(調査)하였으며, 중요한 결과를 요약하면 아래와 같다. 1. 모두 12종(種)의 농약성분을 검출(檢出)하였으며, 검출빈도는 P.P'-DDE (67.6%), ${\gamma}-BHC$(54.8%), ${\gamma}-chlordane$(50.9%), 그리고 ${\alpha}-BHC$(47.1%)의 순(順)이었고, 평균잔류량(平均殘留量)은 ${\alpha}-BHC$, ${\gamma}-chlordane$, P.P'-DDD와 P.P'-DDE가 0.001ppm 수준이었다. 2. 검출시료의 평균잔류수준은 ${\beta}$-BHC가 0.001ppm, ${\alpha}-BHC$, ${\gamma}-chlordane$, P.P'-DDT, O.P'-DDT 및 P.P'-DDD가 모두 0.002ppm 수준이었다. 3. 이상(以上)의 결과에서 볼 때, ${\beta}-BHC$, ${\gamma}-chlordane$ 및 DDT의 대사산물(代謝産物)의 잔류성(性)이 비교적 길은 것으로 나타났으나 전반적(全般的)인 잔류수준은 높지 않은 것으로 평가(評價)할 수 있다.

  • PDF

SENSITIVITY ANALYSIS TO EVALUATE THE TRANSPORT PROPERTIES OF CdZnTe DETECTORS USING ALPHA PARTICLES AND LOW-ENERGY GAMMA-RAYS

  • Kim, Kyung-O;Ahn, Woo-Sang;Kwon, Tae-Je;Kim, Soon-Young;Kim, Jong-Kyung;Ha, Jang-Ho
    • Nuclear Engineering and Technology
    • /
    • 제43권6호
    • /
    • pp.567-572
    • /
    • 2011
  • A sensitivity analysis of the methods used to evaluate the transport properties of a CdZnTe detector was performed using two different radiations (${\alpha}$ particle and gamma-ray) emitted from an $^{241}Am$ source. The mobility-lifetime products of the electron-hole pair in a planar CZT detector ($5{\times}5{\times}2\;mm^3$) were determined by fitting the peak position as a function of biased voltage data to the Hecht equation. To verify the accuracy of these products derived from ${\alpha}$ particles and low-energy gamma-rays, an energy spectrum considering the transport property of the CZT detector was simulated through a combination of the deposited energy and the charge collection efficiency at a specific position. It was found that the shaping time of the amplifier module significantly affects the determination of the (${\mu}{\tau}$) products; the ${\alpha}$ particle method was stabilized with an increase in the shaping time and was less sensitive to this change compared to when the gamma-ray method was used. In the case of the simulated energy spectrum with transport properties evaluated by the ${\alpha}$ particle method, the peak position and tail were slightly different from the measured result, whereas the energy spectrum derived from the low-energy gamma-ray was in good agreement with the experimental results. From these results, it was confirmed that low-energy gamma-rays are more useful when seeking to obtain the transport properties of carriers than ${\alpha}$ particles because the methods that use gamma-rays are less influenced by the surface condition of the CZT detector. Furthermore, the analysis system employed in this study, which was configured by a combination of Monte Carlo simulation and the Hecht model, is expected to be highly applicable to the study of the characteristics of CZT detectors.

A comparison study between the realistic random modeling and simplified porous medium for gamma-gamma well-logging

  • Fatemeh S. Rasouli
    • Nuclear Engineering and Technology
    • /
    • 제56권5호
    • /
    • pp.1747-1753
    • /
    • 2024
  • The accurate determination of formation density and the physical properties of rocks is the most critical logging tasks which can be obtained using gamma-ray transport and detection tools. Though the simulation works published so far have considerably improved the knowledge of the parameters that govern the responses of the detectors in these tools, recent studies have found considerable differences between the results of using a conventional model of a homogeneous mixture of formation and fluid and an inhomogeneous fractured medium. It has increased concerns about the importance of the complexity of the model used for the medium in simulation works. In the present study, we have suggested two various models for the flow of the fluid in porous media and fractured rock to be used for logging purposes. For a typical gamma-gamma logging tool containing a 137Cs source and two NaI detectors, simulated by using the MCNPX code, a simplified porous (SP) model in which the formation is filled with elongated rectangular cubes loaded with either mineral material or oil was investigated. In this model, the oil directly reaches the top of the medium and the connection between the pores is not guaranteed. In the other model, the medium is a large 3-D matrix of 1 cm3 randomly filled cubes. The designed algorithm to fill the matrix sites is so that this realistic random (RR) model provides the continuum growth of oil flow in various disordered directions and, therefore, fulfills the concerns about modeling the rock textures consist of extremely complex pore structures. For an arbitrary set of oil concentrations and various formation materials, the response of the detectors in the logging tool has been considered as a criterion to assess the effect of modeling for the distribution of pores in the formation on simulation studies. The results show that defining a RR model for describing heterogeneities of a porous medium does not effectively improve the prediction of the responses of logging tools. Taking into account the computational cost of the particle transport in the complex geometries in the Monte Carlo method, the SP model can be satisfactory for gamma-gamma logging purposes.

Radiation Detection System for Prevention of Illicit Trafficking of Nuclear and Radioactive Materials

  • Kwak, Sung-Woo;Chang, Sung-Soon;Yoo, Ho-Sik
    • Journal of Radiation Protection and Research
    • /
    • 제35권4호
    • /
    • pp.167-171
    • /
    • 2010
  • Fixed radiation portal monitors (RPMs) deployed at border, seaport, airport and key traffic checkpoints have played an important role in preventing the illicit trafficking and transport of nuclear and radioactive materials. However, the RPM is usually large and heavy and can't easily be moved to different locations. These reasons motivate us to develop a mobile radiation detection system. The objective of this paper is to report our experience on developing the mobile radiation detection system for search and detection of nuclear and radioactive materials during road transport. Field tests to characterize the developed detection system were performed at various speeds and distances between the radioactive isotope (RI) transporting car and the measurement car. Results of measurements and detection limits of our system are described in this paper. The mobile radiation detection system developed should contribute to defending public's health and safety and the environment against nuclear and radiological terrorism by detecting nuclear or radioactive material hidden illegally in a vehicle.

라돈 표준실과 가옥 내에서 일부 라돈검출기에 대한 성능 평가 (Performance Evaluation of Several Radon Detectors in the Standard Chamber and Dwellings)

  • 윤석원;김용재;장병욱;변종인;윤주용
    • Journal of Radiation Protection and Research
    • /
    • 제33권4호
    • /
    • pp.173-181
    • /
    • 2008
  • 실내 라돈 검출기의 신뢰성 평가를 위해서 미국 Landauer사의 $RadTrak^{(R)}$, 헝가리 Radosys사의 $Radopot^{(R)}$, 그리고 미국 Rad elec 사의 $E-PERM^{(R)}$ 검출기의 성능을 비교 검토하였다. RadTrak과 Radopot에 대한 라돈 표준 챔버 테스트 결과, $AlphaGUARD^{(R)}$ 검출 결과와 비교하여 각각 -13.2%. -6.0%로 라돈 검출기 성능평가기준인 ${\pm}20%$ 이내에 포함되는 결과를 보였다. 또한, 실제 현장에서의 장기간 측정을 통한 성능을 평가하기 위하여 약 100여개의 가옥 내 동일한 장소에 각각의 검출기를 1 년 동안 설치하여 비교하였다. RadTrak 과 Radopot 의 비교에서는 매우 좋은 상관관계 ($R^2$ = 0.91)를 보였지만, E-PERM과 Radopot의 비교결과, 거의 상관성을 파악 할 수 없었다($R^2$ = 0.021). 또한, E-PERM을 이용한 연평균 전국 실내 공간감마선량률 등준위도는 Portable Ion Chamber를 이용한 전국 실외 공간감마선량률 등준위도와 다소 상이한 결과를 보였다. 실험 결과를 바탕으로 향 후 대규모 라돈농도조사에 필요한 검출기 선정 요건에 대해서 논의 하였다.

Cortex-A9 기반 휴대용 방사선 검출장치에서의 검출성능 향상을 위한 연구 (Research of Detection performance enhancement from portable radiation detection platform based on Cortex-A9)

  • 권태경;김영길
    • 한국정보통신학회논문지
    • /
    • 제18권6호
    • /
    • pp.1488-1493
    • /
    • 2014
  • 전 세계적으로 해운물류 안전 보안체계가 강화됨에 따라 국가물류보안 체계 구축을 위한 해운물류 안전 보안 핵심기술 개발이 이루어지고 있다. 이러한 국제적 정서에 발맞추어, 국내에서도 감마선 핵종을 검출할 수 있는 휴대용 방사선 검출 장치에 대한 관심이 높아지고 있다. 본 논문에서는 Cortex-A9을 이용한 휴대용 방사선 검출장치 플랫폼 검출 성능의 향상을 위한 연구하였다.