• Title/Summary/Keyword: Gamma 보정

Search Result 160, Processing Time 0.026 seconds

The Comparison of Motion Correction Methods in Myocardial Perfusion SPECT (심근관류 SPECT에서 움직임 보정 방법들의 비교)

  • Park, Jang-Won;Nam, Ki-Pyo;Lee, Hoon-Dong;Kim, Sung-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.28-32
    • /
    • 2014
  • Purpose Patient motion during myocardial perfusion SPECT can produce images that show visual artifacts and perfusion defects. This artifacts and defects remain a significant source of unsatisfactory myocardial perfusion SPECT. Motion correction has been developed as a way to correct and detect the patient motion for reducing artifacts and defects, and each motion correction uses different algorithm. We corrected simulated motion patterns with several motion correction methods and compared those images. Materials and Methods Phantom study was performed. The anthropomorphic torso phantom was made with equal counts from patient's body and simulated defect was added in myocardium phantom for to observe the change in defect. Vertical motion was intentionally generated by moving phantom downward in a returning pattern and in a non-returning pattern throughout the acquisition. In addition, Lateral motion was generated by moving phantom upward in a returning pattern and in a non-returning pattern. The simulated motion patterns were detected and corrected similarly to no-motion pattern image and QPS score, after Motion Detection and Correction Method (MDC), stasis, Hopkins method were applied. Results In phantom study, Changes of perfusion defect were shown in the anterior wall by the simulated phantom motions, and inferior wall's defect was found in some situations. The changes derived from motion were corrected by motion correction methods, but Hopkins and Stasis method showed visual artifact, and this visual artifact did not affect to perfusion score. Conclusion It was confirmed that motion correction method is possible to reduce the motion artifact and artifactual perfusion defect, through the apply on the phantom tests. Motion Detection and Correction Method (MDC) performed better than other method with polar map image and perfusion score result.

  • PDF

Evaluating applicability of metal artifact reduction algorithm for head & neck radiation treatment planning CT (Metal artifact reduction algorithm의 두경부 CT에 대한 적용 가능성 평가)

  • Son, Sang Jun;Park, Jang Pil;Kim, Min Jeong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.107-114
    • /
    • 2014
  • Purpose : The purpose of this study is evaluation for the applicability of O-MAR(Metal artifact Reduction for Orthopedic Implants)(ver. 3.6.0, Philips, Netherlands) in head & neck radiation treatment planning CT with metal artifact created by dental implant. Materials and Methods : All of the in this study's CT images were scanned by Brilliance Big Bore CT(Philips, Netherlands) at 120kVp, 2mm sliced and Metal artifact reduced by O-MAR. To compare the original and reconstructed CT images worked on RTPS(Eclipse ver 10.0.42, Varian, USA). In order to test the basic performance of the O-MAR, The phantom was made to create metal artifact by dental implant and other phantoms used for without artifact images. To measure a difference of HU in with artifact images and without artifact images, homogeneous phantom and inhomogeneous phantoms were used with cerrobend rods. Each of images were compared a difference of HU in ROIs. And also, 1 case of patient's original CT image applied O-MAR and density corrected CT were evaluated for dose distributions with SNC Patient(Sun Nuclear Co., USA). Results : In cases of head&neck phantom, the difference of dose distibution is appeared 99.8% gamma passing rate(criteria 2 mm / 2%) between original and CT images applied O-MAR. And 98.5% appeared in patient case, among original CT, O-MAR and density corrected CT. The difference of total dose distribution is less than 2% that appeared both phantom and patient case study. Though the dose deviations are little, there are still matters to discuss that the dose deviations are concentrated so locally. In this study, The quality of all images applied O-MAR was improved. Unexpectedly, Increase of max. HU was founded in air cavity of the O-MAR images compare to cavity of the original images and wrong corrections were appeared, too. Conclusion : The result of study assuming restrained case of O-MAR adapted to near skin and low density area, it appeared image distortion and artifact correction simultaneously. In O-MAR CT, air cavity area even turned tissue HU by wrong correction was founded, too. Consequentially, It seems O-MAR algorithm is not perfect to distinguish air cavity and photon starvation artifact. Nevertheless, the differences of HU and dose distribution are not a huge that is not suitable for clinical use. And there are more advantages in clinic for improved quality of CT images and DRRs, precision of contouring OARs or tumors and correcting artifact area. So original and O-MAR CT must be used together in clinic for more accurate treatment plan.

Study on the cascade summing correction for high efficiency HPGe detector (고효율 HPGe 검출기의 동시합성효과 보정 연구)

  • Lee, M.S.
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.3
    • /
    • pp.107-112
    • /
    • 2005
  • Cascade summing occurs when two gamma-rays emitted in the decay of a single nucleus both deposit energy in a detector. The effect may cause systematic errors that can reach levels of more than ten percent for some radionuclides. A method for estimation of the effect of these coincidences was developed. It is based on direct computation of the effect by means of peak to total ratio measured for the place around the detector. It has been shown that the P/T ratio for the given energy in the working space around the detector may not be a constant value and must use its mean value. Some results from a peak to total calibration study in the presence of scattering materials are also given.

A Study on Relationship between Hypertension and Dietary Intake in a Rural Adult Population (일부 농촌 성인을 대상으로 한 고혈압과 식이섭취와의 관계에 관한 연구)

  • Go, Un-Yeong;Kim, Joung-Soon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.4 s.59
    • /
    • pp.729-740
    • /
    • 1997
  • To determine the relationship between hypertension and nutrient intake cross-sectional study were performed in a rural area. Adult resident over 30-year-old age were measured blood pressure and body mass index(BMI), and interviewed about food in-take for the previous 24 hours. 250 men and 297 women participated the survey. Significant correlation was showen in men between mean systolic blood pressure and protein density. Significant correlation with mean diastolic blood pressure was showen on protein density, protein energy(%), calcium density and energy-adjusted protein in men. We analysed risk factor for hypertension adjust the effect of age, BMI, sex and family history by multiple logistic regression. Protein density(odds ratio=3.18), fat density(odds ratio=1.94) and energy-adjusted protein(odds ratio=1.01) intake were positively associated with hypertension but sodium density(odds ratio=0.73) was showen to have inverse relationship.

  • PDF

Improved characterization method for mobile phone camera and LCD display (모바일 폰 카메라와 LCD의 향상된 특성화 방법)

  • Jang, In-Su;Son, Chang-Hwan;Lee, Cheol-Hee;Song, Kun-Woen;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.2
    • /
    • pp.65-73
    • /
    • 2008
  • The characterization process for the accurate color reproduction in mobile phone with camera and LCD is popular. The camera and LCD characterization, gamut mapping process is necessary to map the camera's input color stimulus, CIEXYZ value, into the LCD's output color stimulus. Each characterization is the process estimating the relation between input and output signals. In case of LCD, because of output device, the output color stimulus for the arbitrary input signal can be measured by spectro-radiometer However, in the camera, as the input device, the characterization is an inaccurate and needs the manual works in the process obtaining the output signal because the input signal can not be generated. Moreover, after gamut mapping process, the noise is increased because the optimized gamma tone curve of camera for the noise is distorted by the characterization. Thus, this paper proposed the system of obtaining the output signal of camera and the method of gamma correction for the noise. The camera's output signal is obtained by RGB values of patches from captured the color chart image. However, besides the illumination, the error for the location of the chart in the viewfinder is generated when many camera modules are captured the chart. The method of correcting the position to correct the error from manual works. The position of camera is estimated by captured image. This process and moving of camera is accomplished repeatedly, and the optimized position can be obtained. Moreover, the lightness curve of camera output is corrected partly to reduce the noise from the characterization process.

석회암지역에서 불연속면의 물리검층반응

  • Kim, Yeong-Hwa;Yang, Yeong-Geun;Kim, Jung-Yeol;Kim, Yu-Seong
    • Journal of the Korean Geophysical Society
    • /
    • v.4 no.2
    • /
    • pp.95-102
    • /
    • 2001
  • As a basic study of characterizing fracture condition in bore hole, conventional geophysical well log data consisting of sonic, gamma-gamma and resistivity logs were compared with geological core log and acousic televiewer log in limestone geology. Discontinuities shown on the acoustic televiewer log and the core log show fairly good correlation. The conventional Geophysical log is also shown to bi effective in locating discontinities in limestone geology; sonic log shows the best result and resistivity shows the worst. Particularly, the combination method of density and sonic logs is shown to be the most effective in delineating discontinuities.

  • PDF

A Study on the Color Modelling Method for Color Picture Tube Color Display (CPT 색제시를 위한 색모델링 방법 연구)

  • 이응주
    • Journal of Korea Multimedia Society
    • /
    • v.3 no.6
    • /
    • pp.586-591
    • /
    • 2000
  • Color pictures on CPT are generally affected by the receiver characteristic and the condition of exterior illuminants. Moreover, readjustment of incorrect color in the CPT causes color distortion on a given picture. This paper describes a color adjustment method for modelling of CPT at the view point of observer in the ordinary lighting condition. To develop this method, we proposed ways of luminance recompensation under the gamma transformation for the intensity of illuminant, hue/saturation compensation for the types of illuminant and control of specific color for the reference. Based on these method, a color correlation system is suggested with the goal of reducing the color errors which are represented due to the influence of reflectance component of illuminants, the gamma transformation of CPT and the frequently adjustment of reference scene to set a optimum color.

  • PDF

RESULTS OF THE TOTAL DOSE EXPERIMENT ON KITSAT-1 (우리별 1호에서의 총 방사선 측정 실험)

  • 이대희;신영훈;민경욱
    • Journal of Astronomy and Space Sciences
    • /
    • v.14 no.1
    • /
    • pp.80-86
    • /
    • 1997
  • High energy particles in the earth's radiation belts cause transient and long term effects on electronic materials, devices, and integrated circuits on board the satellites. Hence, it is very important to have the information on the space radiation environment and the damage on the electronics caused by the se high energy particles. One of the radiation monitor devices frequently used in space is RADFET, a specially designed MOSFET with a thick gate oxide region. The present study focuses on the calibration of RADFET TOT500 using the $Co^{60}{\gamma}-ray$ source. The result shows that the response of RADFET is very sensitive to the change of temperature. The peculiar behavior observed in the TDE (Total Dose Experiment) on board the KITSAT-1 is identified as the thermal effect due to the change in the eclipse rate of the satellite.

  • PDF

Development of Geometric Calibration Method for Triple Head Pinhole SPECT System (삼중헤드 SPECT에서 기하학적 보정 기법의 개발)

  • Kim, Joong-Hyun;Lee, Jae-Sung;Lee, Won-Woo;Park, So-Yeon;Son, Ji-Yeon;Kim, Yu-Kyeong;Kim, Sang-Eun;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.61-69
    • /
    • 2008
  • Purpose: Micro-pinhole SPECT system with conventional multiple-head gamma cameras has the advantage of high magnification factor for imaging of rodents. However, several geometric factors should be calibrated to obtain the SPECT image with good image quality. We developed a simplified geometric calibration method for rotating triple-head pinhole SPECT system and assessed the effects of the calibration using several phantom and rodent imaging studies. Materials and Methods: Trionix Triad XLT9 triple-head SPECT scanner with 1.0 mm pinhole apertures were used for the experiments. Approximately centered point source was scanned to track the angle-dependent positioning errors. The centroid of point source was determined by the center of mass calculation. Axially departed two point sources were scanned to calibrate radius of rotation from pinhole to center of rotation. To verify the improvements by the geometric calibration, we compared the spatial resolution of the reconstructed image of Tc-99m point source with and without the calibration. SPECT image of micro performance phantom with hot rod inserts was acquired and several animal imaging studies were performed. Results: Exact sphere shape of the point source was obtained by applying the calibration and axial resolution was improved. Lesion detectibility and image quality was also much improved by the calibration in the phantom and animal studies. Conclusion: Serious degradation of micro-pinhole SPECT images due to the geometric errors could be corrected using a simplified calibration method using only one or two point sources.

An Recognition and Acquisition method of Distance Information in Direction Signs for Vehicle Location (차량의 위치 파악을 위한 도로안내표지판 인식과 거리정보 습득 방법)

  • Kim, Hyun-Tae;Jeong, Jin-Seong;Jang, Young-Min;Cho, Sang-Bock
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.1
    • /
    • pp.70-79
    • /
    • 2017
  • This study proposes a method to quickly and accurately acquire distance information on direction signs. The proposed method is composed of the recognition of the sign, pre-processing to facilitate the acquisition of the road sign distance, and the acquisition of the distance data. The road sign recognition uses color detection including gamma correction in order to mitigate various noise issues. In order to facilitate the acquisition of distance data, this study applied tilt correction using linear factors, and resolution correction using Fourier transform. To acquire the distance data, morphological operation was used to highlight the area, along with labeling and template matching. By acquiring the distance information on the direction sign through such a processes, the proposed system can be output the distance remaining to the next junction. As a result, when the proposed method is applied to system it can process the data in real-time using the fast calculation speed, average speed was shown to be 0.46 second per frame, with accuracy of 0.65 in similarity value.