• Title/Summary/Keyword: Gamma 보정

Search Result 160, Processing Time 0.024 seconds

A Study on Spine and Rib Properties for Standoff Compensation, Density Log (밀도검층 이격 보정을 위한 기준선과 이격선의 특성 연구)

  • Kim, Yeonghwa;Kim, Jongman
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.190-198
    • /
    • 2012
  • A series of density log data were obtained from the standoff experiments made in the four physical model boreholes of different densities, and the properties of spine and rib curves have been derived by the analysis of the gamma-gamma data. Particularly, the shape of gamma ray propagation path between source and detector, the geometrical property of spine and rib curves, the influence of borehole density and the detector combination on the properties of the curves, and the adequate detector combination for standoff compensation could be discussed. It was also confirmed that spine and rib slopes can be expressed as proportional to source-to-detector distance ratio between far and near detectors. The result of this experiment was also effectively applied for understanding the basic concept of spine and rib slopes.

A Study of Quality Control of Nuclear Medicine Counting System and Gamma Camera (핵의학 계측기기 및 감마카메라의 정도관리 연구)

  • 손혜경;김희중;정해조;정하규;이종두;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.103-112
    • /
    • 2001
  • Purpose: The purpose of this study was to investigate the current status of performing nuclear medicine quality control in korea and to test selected protocols of quality control of nuclear medicine counting system and gamma camera. Materials and Methods: Fifty three hospitals were included to investigate the current status of nuclear medicine quality control in korea. The precision of dose calibrator and thyroid uptake system was measured with Tc-99m 35.52 MBq for 2 minuets and Tc-99m 5.14 MBq for 10 sec every one minute, respectively. The sensitivity of CeraSPECT$^{TM}$ with low energy high resolution parallel hole collimator was measured using two cylindrical phantoms with 15 cm in diameter and 12 cm and 30 cm in heights containing Tc-99m. The correction factor for sensitivity of CeraSPECT$^{TM}$ was calculated using phantom data. The system planar sensitivity, uniformity, count rate and spatial resolution were measured for Varicam gamma camera with low energy high resolution parallel hole collimator using 140 keV centered 20% energy window, 256$\times$256 or 512$\times$512 matrix sizes. Results: The quality control of dose calibrator and well counter were showed poor performance status. On the other hand, The quality control of gamma camera and other systems were showed relatively good performance status. The results of precision of dose calibrator and thyroid uptake system was $\pm$1.4%(<$\pm$5%) and chi^2=29.7(>16.92), respectively. It showed that the sensitivity of CeraSPECT$^{TM}$ was higher in center slices compared with the edge slices. After correction of nonuniform sensitivities for patient data, it showed better results compare with prior to correction. System planar sensitivity of Varicam gamma camera was 4.39 CPM/MBq. The observed count rate at 20% loss was 102,407 counts/sec (head 1), 113,427 counts/sec (head 2), when input count rate was 81,926 counts/sec (head 1), 90,741 counts/sec (head 2). The spatial resolution without scatter medium were 8.16 mm of FWHM and 14.85 mm of FWTM. The spatial resolution with scatter medium were 8.87 mm of FWHM and 18.87 mm of FWTM. Conclusion: It is necessary to understand the importance of quality control and to perform quality control of nuclear medicine devices.vices.

  • PDF

Histogram Equalization using Gamma Transformation (감마변환을 사용한 히스토그램 평활화)

  • Chung, Soyoung;Chung, Min Gyo
    • KIISE Transactions on Computing Practices
    • /
    • v.20 no.12
    • /
    • pp.646-651
    • /
    • 2014
  • Histogram equalization generally has the disadvantage that if the distribution of the gray level of an image is concentrated in one place, then the range of the gray level in the output image is excessively expanded, which then produces a visually unnatural result. However, a gamma transformation can reduce such unnatural appearances since it operates under a nonlinear regime. Therefore, this paper proposes a new histogram equalization method that can improve image quality by using a gamma transformation. The proposed method 1) derives the proper form of the gamma transformation by using the average brightness of the input image, 2) linearly combines the earlier gamma transformation with a CDF (Cumulative Distribution Function) for the image in order to obtain a new CDF, and 3) to finally perform histogram equalization by using the new CDF. The experimental results show that relative to existing methods, the proposed method provides good performance in terms of quantitative measures, such as entropy, UIQ, SSIM, etc., and it also naturally enhances the image quality in visual perspective as well.

Background Reduction for the ${\gamma}$-Ray Spectrometry of Environmental Radioactivity (환경방사능의 감마선 분광분석을 위한 백그라운드 소멸)

  • Seo, Bum Kyoung;Lee, Kil Yong;Yoon, Yoon Yeol;Lee, Dae Won
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.212-220
    • /
    • 2001
  • This study was performed to establish the analytical method of radium and radon in various environmental samples with the ${\gamma}$-ray spectrometry. The major problem in the measurements of low level ${\gamma}$-ray, such as environmental radioactivity, is the fluctuation of ${\gamma}$-ray background spectrum. To overcome this problem, a nitrogen gas was filled up in the detector chamber to reduce the background counts due to airborne radioactivities, i.e., $^{214}Pb$ and $^{214}Bi$, the daughters of $^{222}Rn$ in air. When nitrogen gas flowed around the detector, peak counts of ${\gamma}$-rays from the daughters of $^{222}Rn$ decreased about 80% below 1 MeV and about 20~50% above 1 MeV. The use of nitrogen purging results in approximately tenfold increment of sensitivity.

  • PDF

Calculation of the Correction Factors related to the Diameter and Density of the Concrete Core Samples using a Monte Carlo Simulation (몬테카를로 전산해석을 이용한 콘크리트 코어시료의 직경과 밀도에 따른 보정인자 계산)

  • Lee, Kyu-Young;Kang, Bo Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.503-510
    • /
    • 2020
  • Concrete is one of the most widely used materials as the shielding structures of a nuclear facilities. It is also the most generated radioactive waste in quantity while dismantling facilities. Since the concrete captures neutrons and generates various radionuclides, radiation measurement and analysis of the sample was fulfilled prior to dismantle facilities. An HPGe detector is used in general for the radiation measurement, and effective correction factors such as geometrical correction factor, self-absorption correction, and absolute detector efficiency have to be applied to the measured data to decide exact radioactivity of the sample. Correction factors are obtained by measuring data using a standard source with the same geometry and chemical states as the sample under the same measurement conditions. However, it is very difficult to prepare standard concrete sources because concrete is limited in pretreatment due to various constituent materials and high density. In addition, the concrete sample obtained by core drill is a volumetric source, which requires geometric correction for sample diameter and self absorption correction for sample density. Therefore in recent years, many researchers are working on the calculation of effective correction factors using Monte carlo simulation instead of measuring them using a standard source. In this study we calculated, using Geant4, one of the Monte carlo codes, the correction factors for the various diameter and density of the concrete core sample at the gamma ray energy emitted from the nuclides 152Eu and 60Co, which are the most generated in radioactive concrete.

Cap-Divided 방식의 VA 액정모드를 채용한 신규 반투과형 LTPS-LCD 개발

  • Gang, Seung-Gon;Kim, Seong-Ho;Song, Seok-Cheon;Park, Won-Sang;Lee, Cheong;Kim, Chi-U;Jeong, Gyu-Ha
    • Information Display
    • /
    • v.5 no.5
    • /
    • pp.10-12
    • /
    • 2004
  • 우수한 화질특성을 나타내는 새로운 반투과형 액정모드를 개발했다. 단일 셀캡 구조에서 감마(Gamma) 보정없이 투과모드와 반사모드를 동시에 구동하기 위해 유기막을 이용하여 반사모드 영역의 액정 Cap을 두 가지로 분리하는 새로운 설계구조를 도입했다. 반사모드 영역의 액정 Cap을 순수한 액정 $Cap(C_{LC})$과 유기막 $Cap(C_{OL})$으로 분리함으로써 액정에 걸리는 실제 전압을 조절하게 되어 단일 셀캡 구조에서도 감마 보정없이 우수한 특성을 나타내는 반투과형 VA 액정모드를 개발하였다. 이러한 Cap-Divided 방식의 신규 VA 액정모드는 높은 콘트라스트, 광시야각 특성 및 공정 단순화의 장점이 있기 때문에 향후 반투과형 LCD에 적극적인 채용이 기대되어진다.

Implementation of Digital Portable Radiation Detector with the Algorithm of Temperature Compensation (온도 보정 Algorithm을 적용한 Digital 휴대용 방사선 검출기의 구현)

  • Park, Ge-O;Lee, Jung-Hyun;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.202-205
    • /
    • 2016
  • Shipping and logistics safety, security system is strengthening worldwide, the development of shipping and logistics safety security core technology for national security logistics system construction has been carried out. Interest in portable radiation detection device capable detecting gamma rays nuclides is increasing. In this paper, I would like to propose the study of implementation of digital portable radiation detector with the algorithm of temperature compensation.

  • PDF

Enhancement of haze Images Using Adaptive Transmission (영상의 적응적인 전달량을 이용한 안개 영상 개선)

  • Pang Jun Ho;Jeong Hyeon Jeong;kim Jin Woo
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2024.01a
    • /
    • pp.85-88
    • /
    • 2024
  • 안개 영상은 먼지, 안개 등의 원인으로 영상 내의 물체가 흐리게 보이며, 빛의 산란으로 인하여 영상의 밝기가 높다. 기존의 다크 채널 방식은 하늘 영역을 따로 처리하지 않고, 안개 영상에서 얻어지는 다크채널을 바탕으로 전달량을 추정한다. 이러한 방식은 안개 영상 내 하늘 영역이 왜곡되는 문제가 발생하게 된다. 이와 같은 문제점을 해결하기 위하여 본 논문에서는 영상의 반전, 유클리드, 그리고 감마보정을 이용한 적응형 전달량을 추정하여 성능을 개선하였다.

  • PDF

Color Correction Method of Non-standard Display Using Standard Color Space (표준 색공간을 이용한 비표준 디스플레이의 색 보정 방법)

  • Kim, Eun-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2151-2157
    • /
    • 2015
  • A standard default color space, sRGB, provides compatibility for the transmission of color within the Internet color operating systems and device drivers. However, a display monitor we use generally have non-standard primaries and gamma characteristic different from those specified by sRGB. In this paper, correction methods of chromatic error for a non-standard display monitor are proposed. Experimental results show that the proposed method using the correction matrix reduced chromatic errors at in compared with the non-corrected image's on a non-standard display.

Algorithms for Implementing One Chip Binary Image Processor (1칩 이진 영상 처리기 구현을 위한 알고리즘)

  • 조석팔;진용옥
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.3
    • /
    • pp.297-306
    • /
    • 1992
  • Algorithms for implementing one chip binary image processor has been studied. In this paper, image quality improvement algorithms, for the data pre-processed with shading and gamma correction after digitizing the analog signal from CCD or CIS, such as : Improved high quality binarization algorithm is suggested. Error diffusion algorithms for high quality half-tone images is analyzed, Fuzzy Theory based mixed mode algorithm is suggested.

  • PDF