• Title/Summary/Keyword: Gamma 보정

Search Result 160, Processing Time 0.03 seconds

Flesh Tone Balance Algorithm for AWB of Facial Pictures (인물 사진을 위한 자동 톤 균형 알고리즘)

  • Bae, Tae-Wuk;Lee, Sung-Hak;Lee, Jung-Wook;Sohng, Kyu-Ik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.11C
    • /
    • pp.1040-1048
    • /
    • 2009
  • This paper proposes an auto flesh tone balance algorithm for the picture that is taken for people. General white balance algorithms bring neutral region into focus. But, other objects can be basis if its spectral reflectance is known. In this paper the basis for white balance is human face. For experiment, first, transfer characteristic of image sensor is analyzed and camera output RGB on average face chromaticity under standard illumination is calculated. Second, Output rate for the image is adjusted to make RGB rate for the face photo area taken under unknown illumination RGB rate that is already calculated. Input tri-stimulus XYZ can be calculated from camera output RGB by camera transfer matrix. And input tri-stimulus XYZ is transformed to standard color space (sRGB) using sRGB transfer matrix. For display, RGB data is encoded as eight-bit data after gamma correction. Algorithm is applied to average face color that is light skin color of Macbeth color chart and average color of various face colors that are actually measured.

Evaluation on the Usefulness of 6DoF Couch in V-MAT on Patients with Long length of Target (표적의 길이가 긴 환자의 용적회전변조 방사선치료 시 6DoF Couch의 유용성 평가)

  • Choi, Young Se;Park, Hyo Kuk;Kim, Se Young;Kim, Joo Ho;Lee, Sang Kyoo;Yoon, Jong Won;Cho, Jung Heui
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.53-64
    • /
    • 2017
  • Purpose: To evaluate the usefulness of the $HexaPOD^{TM}$ evo RT system(6DoF couch) and the tendency of dose difference according to size of rotational direction error for volumetric rotational modulated radiotherapy(V-MAT) in patients with long target lengths. Therefore, it is suggested to recommend the need for rotational error correction. Materials and Methods: Ten patients with Esophagus cancer or Breast cancer including SCL treated with HexaPOD 6DoF(Six-Degree of Freedom) couch were included in this study. 6DoF couch was used to measure the difference in dose according to the rotation error in the directions of Rx(pitch), Ry(roll), and Rz(yaw). Each rotation error was applied. Positioning variation on x, y and z axis was verified and random variations were made by 6DoF couch with positioning variation. Modified DQA is conducted and point dose and gamma value are analyzed and compared. In addition, after applying the rotation error every $1^{\circ}$ to treatment plans of each target with a diameter of 3 cm, 5, 10, 15, and 20 cm respectively, gamma passing rate is being monitored by its aspect of change according to types and sizes of the target length and rotation error. Results: Mean error of the point dose and Gamma passing rate when the position variation was applied were $2.50{\pm}1.11%$ and $84.1{\pm}7.39%$ in the Rx direction, $2.36{\pm}1.16%$, and $81.0{\pm}8.49%$ in the Ry, $2.35{\pm}1.10%$ and $84.4{\pm}6.99%$ in the Rz direction, respectively. As a result of analysis on gamma passing rate according to types and sizes of the target length and rotation error, the gamma passing rate tended to decrease with increasing rotation error in the Rx and Rz directions except Ry direction. In particular, the lowest gamma passing rate (74.2 %) was in the case of $2.5^{\circ}$ rotation error in Rz direction of the target of 10 cm. Conclusion: The correction of the rotational error is needed for volumetric modulated radiotherapy of the treatment area with a long target length, and the use of 6DoF couch will improve the reproducibility of the patient position and the quality of the treatment.

  • PDF

Change of Dose Distribution on the Beam Axis of 60Co γ Ray and 10MV X-Ray with Part Thickness (치료부위(治療部位)두께에 따른 Co-60 γ선(線)과 10MV X선(線)의 선축상(線軸上) 선량분포(線量分布)의 변화(變化))

  • Kang, Wee Saing;Koh, Kyoung Hwan;Ha, Sung Whan;Park, Charn Il
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.21-24
    • /
    • 1983
  • The thickness of the part being irradiated is finite. Percent depth dose tables being used routinely are generally obtained from dosimetry in a phantom much thickner than usual patient. At or close to exit surface, the dose should be less than that obtained from the percent depth dose tables, because of insufficient volume for backscattering. To know the difference between the true absorbed dose and the dose obtained from percent depth dose table, the doses at or close to the exit surface were measured with plate type ionization chamber with volume of 0.5ml. The results are as follows; 1. In the case of $^{60}Co$, percent depth dose at a given depth increases with underlying phantom thickness up to the 5cm. 2. In the case of $^{60}Co$, the dose correction factor at exit surface which is less than 1, increases with part thickness and decreases with field size. 3. Exposure time may not be corrected when the part above 10cm in thickness is treated by $^{60}Co$. 4. In the case of 10MV x-ray, the dose correction factor is nearly 1 and constant for the underlying phantom thickness and field size, so the correction of monitor unit is not necessary for part thickness.

  • PDF

A Practical and Simple Method of Self-absorption Correction for Environmental Samples (실용적이고 간단한 환경시료의 감마핵종 자체흡수보정 방법)

  • Lee, Wan-No;Lee, Haeng-Pil;Chung, Kun-Ho;Cho, Young-Hyun;Choi, Geun-Sik;Lee, Chang-Woo;Chung, Hyung-Wook;Lee, Eun-Ju;Sho, You-Sup;Lee, Jong-Ok
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.1
    • /
    • pp.47-52
    • /
    • 2006
  • A self-absorption correction is important issue for the exact radioactivity determination of gamma emitting radionuclides in environmental samples which have the range of apparent density from $0.3g/cm^3$ up to $1.5g/cm^3$. In this paper, a practical and simple method without radioactive standard solutions having various densities is proposed for the self-absorption correction of environmental samples by a developed outside beaker surrounding Marinelli beaker. For the densities of 0.8, 1.0, $1.3g/cm^3$, the corrected efficiencies by the new method and the measured those by radioactive standard solutions of the three densities showed good agreement within 4 %.

The Segmented Polynomial Curve Fitting for Improving Non-linear Gamma Curve Algorithm (비선형 감마 곡선 알고리즘 개선을 위한 구간 분할 다항식 곡선 접합)

  • Jang, Kyoung-Hoon;Jo, Ho-Sang;Jang, Won-Woo;Kang, Bong-Soon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.3
    • /
    • pp.163-168
    • /
    • 2011
  • In this paper, we proposed non-linear gamma curve algorithm for gamma correction. The previous non-linear gamma curve algorithm is generated by the least square polynomial using the Gauss-Jordan inverse matrix. However, the previous algorithm has some weak points. When calculating coefficients using inverse matrix of higher degree, occurred truncation errors. Also, only if input sample points are existed regular interval on 10-bit scale, the least square polynomial is accurately works. To compensate weak-points, we calculated accurate coefficients of polynomial using eigenvalue and orthogonal value of mat11x from singular value decomposition (SVD) and QR decomposition of vandemond matrix. Also, we used input data part segmentation, then we performed polynomial curve fitting and merged curve fitting results. When compared the previous method and proposed method using the mean square error (MSE) and the standard deviation (STD), the proposed segmented polynomial curve fitting is highly accuracy that MSE under the least significant bit (LSB) error range is approximately $10^{-9}$ and STD is about $10^{-5}$.

SIMULATION OF SHIELDING EFFECTS ON THE TOTAL DOSE OBSERVED IN TDE OF KITSAT-1 (KITSAT-1 TDE의 차폐 효과에 의한 총 축적 방사능양 변화에 대한 연구)

  • 김성준;신영훈;민경욱
    • Journal of Astronomy and Space Sciences
    • /
    • v.18 no.1
    • /
    • pp.71-80
    • /
    • 2001
  • The threshold voltage shift observed in TDE (Total Dose Experiment) on board the KITAT-1 is converted into dose (rad($SiO_2$)) using the result of laboratory calibration with Co-60 gamma ray source in KAERI (Korea Atomic Energy Research Institute). Simulation using the NASA radiation model of geomagnetosphere verifies that the dose difference between RADFET1 and RADFET3 observed on KITSAT-1 comes from the difference in shielding thickness at the position of these RADFETs.

  • PDF

A study of Three Dimension Shape Measurement by PS(Phase-Shift) (PS(Phase Shift)방법을 이용한 3차원 형상 측정에 대한 연구)

  • Lee, Hye-In;Kim, Hye-Jin;HwanBo, Seong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1784-1785
    • /
    • 2011
  • PS(Phase Shift) 방식을 이용하여 3차원 이미지 형상복원 시스템을 구현하였다. PS 방식은 위상을 이동시켜서 얻어진 강도를 arctan 시킴으로써 $-{\pi}{\sim}{\pi}$ 범위의 접혀진(wrapped) 위상을 얻을 수 있으며, 이러한 wrapped 위상을 위상 펼침(unwrapping) 알고리즘을 이용하여 불연속을 제거할 수 있다. 얻어진 위상 정보는 물체의 높이 정보에 비례하기 때문에 위상 분포로써 3차원 형상을 복원할 수 있다. Unwrapping 알고리즘에는 다양한 방식이 있지만 본 연구에서는 LabVIEW 프로그램을 이용하여 Goldstein 알고리즘을 구현하였으며, 감마(Gamma) 효과에 의한 노이즈를 줄이기 위하여 프로젝트와 카메라의 보정(calibration) 프로그램을 개발 및 적용하였다. 이와 같은 실험을 통하여 효과적으로 3차원 형상 정보를 얻을 수 있었다.

  • PDF

대마젤란은하 식쌍성의 측광 및 분광 관측

  • Hong, Gyeong-Su;Gang, Yeong-Un
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.55.1-55.1
    • /
    • 2010
  • 대마젤란 은하에 속한 식쌍성의 시선속도 곡선을 완성하기 위하여 2009년 11월 칠레에 위치한 Cerro Tololo Inter-American Observatory (CTIO)의 1.5m 망원경과 R-C Spectrograph를 사용하여 중 분산 분광관측을 수행하였다. 분광관측은 380nm - 540nm 영역에서 $H_8,\;H_{\varepsilon},\;H_{\delta},\;H_{\Gamma},\;H_{\beta}$ 등의 흡수선을 관측하였다. 중분산으로 관측된 식쌍성의 각 구성원별에서 나오는 흡수선들은 구별되지 않으므로 이를 구별하기 위하여 구성원들의 Flux 비와 함께 gauss curves fitting 방법으로 각 흡수선들을 2개의 성분으로 분해하여 시선속도를 측정하고, 시선속도곡선을 완성하였다. 완성된 이중 시선속도 곡선은 Wilson & Devinney 차등 보정법으로 분석하여, 궤도 장반경, 질량비, 계의 시선속도 등을 구하였다. 또한 각 식쌍성들의 광도곡선을 분석하여 측광학적인 해를 구하고, 최종적으로 분광 및 측광관측의 해를 혼합하여 대마젤란은하 식쌍성들의 절대량을 구하였다. 이후 이를 바탕으로 거리를 구하여 기존에 발표된 마젤란은하의 거리와 비교하였다.

  • PDF

KSTAR 고속 중성입자 검출기 제작

  • Kim, Seon-Ho;Wang, Seon-Jeong;Gwak, Jong-Gu;Kim, Seong-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.307-307
    • /
    • 2010
  • ICRF 또는 NB 시스템에 의해 가열된 고에너지 이온들을 측정하는 것은 핵융합 플라즈마에서 중요한 과제 중의 하나이다. 특히 ICRF를 이용한 D(H) 플라즈마의 H minority의 가열은 H의 분율에 따라 가열의 정도가 달라지고 이 결과는 이온의 고에너지 측정을 통해서 확인할 수 있으므로 정확한 고속 이온의 측정은 매우 중요하다. 본 연구에서는 고속 이온을 전하 교환된 중성입자로부터 측정하는 중성입자 검출기를 개발하였다. Si 광다이오드인 AXUV3ELA를 기반으로 50-300 keV 범위의 고에너지 H 및 D 이온을 측정할 수 있는 소형의 중성입자 검출기(Compact Neutral Particle Analyzer : CNPA)가 설계 제작되었다. 검출된 신호는 Pre-amp와 shaping amplifier를 통해 증폭되고 shaping 되며 마지막으로 다중채널 분석기(Multi Channel Analyzer : MCA)를 통해서 계수된다. 본 발표에서는 NPA의 구체적인 설계 특성과 함께 Am-241 gamma ray 선원을 이용한 NPA의 시험 및 보정결과를 보고할 예정이다.

  • PDF

A Study on the Measurement of the Personal Exposure Dose by Film Badge Dosimeter (필름배지선량계에 의한 개인피폭선량 측정에 관한 연구)

  • Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.1
    • /
    • pp.37-50
    • /
    • 1994
  • The experimental evaluation of exposure conversion formula using the relationship between optical photo-density, exposure dose and the quality of radiation characteristics of radiation energy to X-ray and ${\gamma}-rays$. The film badge dosimeter is analysed by exposure conversion formula which evaluate image fading characteristics for development time and directional characteristics for incident beam angle. In conclusion, exposure conversion formula evaluated of this study is satisfied with quality decision criterion of the film badge dosimeter.

  • PDF