• 제목/요약/키워드: Galvanized Steel

검색결과 243건 처리시간 0.023초

파이프 골조 온실 구조물의 표준내용연수 연구 (A Study on the Standard Durable Years of Pipe Framed Greenhouses)

  • 남상운
    • 한국농공학회지
    • /
    • 제43권1호
    • /
    • pp.96-101
    • /
    • 2001
  • In designing the greenhouse structures, snow and wind loads must be estimated on the basis of the probability of occurrence of snow or wind storms of a given intensity. The recurrence interval chosen depends on the standard durable years and safety factors of the greenhouse. This study was carried out to find the standard durable years of pipe framed greenhouses. Bend test for metallic materials was conducted on samples of galvanized steel pipes being used in greenhouse frames. A secular change of collapse loads and flexural rigidity for galvanized steel pipes were analyzed with the parts buried in the ground and exposed in the atmosphere. From those experimental results and corrosion rate of galvanized film, the standard durable years for pipe framed greenhouses are estimated as follows ; the small scale pipe houses of movable type is 7∼8 years and the large scale pipe houses of fixed type is 14∼15 years.

  • PDF

알루미늄 합금의 저항점 용접에 관한 연구 ( I ) (A Study on the Resistance Spot Welding of Aluminum Alloy (I))

  • 김상필;홍태민;장희석
    • Journal of Welding and Joining
    • /
    • 제12권4호
    • /
    • pp.127-140
    • /
    • 1994
  • Resistance spot welding has been widely used in the sheet metal joining processes because of its high productivity and convenience. In the resistance spot welding processes the size of molten nugget is a criterion to assess weld quality. Many research have founded on measuring weld nugget size at the same time monitoring welding process parameters such as dynamic resistance and electrode movement. With increasing demand of energy saving, many efforts were made to employ aluminum alloys that are lighter than steel and have relatively equivalent strength to steel in the automobile industry. In this paper, spot weldability of aluminum alloys for various welding conditions were examined by series of experiments. One of the 6000 series (Mg-Si) aluminum alloy, 6383-T4 was chosen, which is currently considered as a substitute for the galvanized steel. Dynamic resistance, electrode movement and corresponding nugget size were observed and compared to the case of steel. Finally, resistance spot welding of dissimilar material (galvanized steel-aluminum alloy) was attempted.

  • PDF

각종 도금강판의 신장성형시 마찰계수측정 (Measurement of Friction Coefficient in Stretching of Coated Steel Sheets)

  • 권재욱;김인수;이동녕
    • 소성∙가공
    • /
    • 제1권1호
    • /
    • pp.75-86
    • /
    • 1992
  • Coated sheet steels have been increasingly used in automotive industry for improving corrosion resistance. One of the arised concerns is frictional behavior of coated sheet steel in stamping process. But analyses of the frictional behavior are complex and difficult. A tensile strip test has been developed for evaluating friction under the condition which simulate the stretching of sheet. Tests are conducted under different die radius and lubrication conditions. Electro-galvanized steel sheets show a lower coefficient of friction than bare steel sheets whose coated layers have been chemically removed. The coefficients of friction are independent of die radius.

  • PDF

GA에 의한 차량용 이종재 최적점용접 조건 (Optimal Condition for Spot Weldment of Dissimilar Steel Sheet in Automotive)

  • 한재희;양성모;유효선;김태진
    • 한국자동차공학회논문집
    • /
    • 제18권4호
    • /
    • pp.68-73
    • /
    • 2010
  • Welding conditions in process of spot welding must become optimum and need to guarantee stability and reliability of vehicle body considering dynamic load history. Because welding parameters in process of spot welding are various, it is difficult that the quality of spot weldment was included in the optimum levels. In this paper, we found the optimum welding conditions satisfying KS spot welding qualities using genetic algorithm and spot welding experiments of high tensile strength steel and galvanized steel. Those experiments were dissimilar weld and 2-lap spot welding. Genetic algorithm created random welding condition after that, selected optimum individuals by probability concept.

인히비터 첨가용액의 침지에 의한 용융아연도금 강판의 내식성 개선에 관한 전기화학적 연구 (An Electrochemical Study on the Corrosion Resistance Improvement of Galvanizing Steel by Dipping to Solution with Inhibitor)

  • 문경만;조황래;강태영;이명훈;김윤해
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권2호
    • /
    • pp.173-181
    • /
    • 2007
  • Recently, galvanizing method is predominantly being used not only a economical point of view but also due to it s stability and long life. For example, guard rail of high way, all kinds of structures for ship etc. were protected with galvanizing and demand of galvanized structural materials was being increased with more and more. However, galvanized structures were inevitably being deteriorated with time eventually because they were corroded with solution of galvanizing film and exfoliation of it s film in the present severe corrosive environment. Therefore, it is necessary to improve the corrosion resistance of the galvanizing film through various methods such as variation of chemical composition of galvanizing bath, chromate treatment and coating treatment. In this study, three test specimens such as pure galvanizing, galvarium, and chromate treatment were submerged at tap water with inhibitor addition. And the effect of their corrosion resistance improvement was comparatively investigated with electrochemical method. Corrosion current density of the galvanized steel was the largest among three specimens, however, the galvarium steel showed the lowest corrosion current density. Futhermore, these three kinds of test specimens indicated considerably excellent corrosion resistance by dipped at tap water with inhibitor addition. Especially, the galvanized steel showed the best effect of corrosion resistance improvement than other test specimens.

계장화 압입시험 및 유한요소해석을 이용한 아연도금강판의 기계적 물성 추정 (Determination of Mechanical Properties of Galvanized Steel Sheets Using Instrumented Indentation Technique and Finite Element Analysis)

  • 진지원;곽성종;김태성;노기한;강기원
    • 대한기계학회논문집A
    • /
    • 제36권5호
    • /
    • pp.529-535
    • /
    • 2012
  • 본 논문의 목적은 계장화 압입시험과 유한요소해석을 이용하여 아연도금강판의 기계적 물성을 추정하는 것이다. 먼저 인장시험을 통하여 유한요소해석에 요구되는 두께에 따른 아연도금강판의 기계적 물성을 획득하였으며, 이를 이용하여 유한요소해석을 수행하여 특정지점에서의 소성 응력 및 변형률을 획득하였다. 이러한 유한요소해석의 유효성은 계장화 압입시험의 하중-변위선도와 비교를 통하여 검토하였다. 유한요소해석을 통하여 구한 진응력-진변형률 곡선을 인장시험 결과와 비교하여 이의 정확성을 검증하였으며 또한 이를 바탕으로 대표 응력 및 변형률 산출지점을 재평가하였다.

주철의 재질에 미치는 각종 Steel scrap의 영향 (Effect of Various Steel Scrap on the Microstructures and Mechanical Properties of Ductile Cast Iron)

  • 김홍범;;한용남;곽희환;이종문;김찬규
    • 자원리싸이클링
    • /
    • 제9권1호
    • /
    • pp.15-20
    • /
    • 2000
  • Zn을 많이 함유하는 銅scrap(자동차용강판, Zn표면처리강판 등)을 이용하여 구상흑연주철을 제조한 경우 구상화가 제대로 이루어 지지 않았다. Sb을 많이 함유하는 銅scrap을 이용하여 구상흑연주칠을 제조한 경우에는 기지 층의 퍼얼라이트량이 증가하였다. 퍼얼라이트량이 증가하면 인장강도 및 경도는 증가하지만 연산율은 감소하였다. Mn, Cr을 많이 함유한 銅scrap(기계구조용강판, 가단주철)을 이용하여 구상흑연주출을 제조한 경우에는 피얼라이트량이 증가하였으며, 인장강도 및 경도도 증가하였다.

  • PDF

공동주택의 노후 급수관 개선방안에 관한 연구 : 부천시 공동주택을 중심으로 (The Replacement Plans for Aged Public Water Supply Pipes in Apartment Buildings : Especially Apartment Buildings in Bucheon)

  • 이용화;허용철
    • 설비공학논문집
    • /
    • 제27권4호
    • /
    • pp.228-232
    • /
    • 2015
  • The water supply galvanized steel pipes of apartment buildings in Bucheon city constructed with building permission before 1994 have many problems such as leaks, the water containing rust, and low water pressure due to corrosion. Therefore, this study aims to find a way to renew the water supply pipes under investigation through a survey. As a result, when replacing the galvanized steel pipe with the corrosion-resistant pipe, the water supply system should also be changed from the gravity tank system to the booster pump system and the hygienic water storage tank. It is necessary to redraft the long-term repair plan including the replacement of the water supply system. Also, it is necessary to save the allowance reserve according to the modified long-term repair plan.

아연도금강관의 가스메탈아크용접에서 용접인자가 기공형성에 미치는 영향 (Effects of Welding Parameters on Porosity Formation in Weld Beads of Galvanized Steel Pipes produced with Gas Metal Arc Welding)

  • 임영민;장복수;고진현
    • Journal of Welding and Joining
    • /
    • 제30권5호
    • /
    • pp.46-50
    • /
    • 2012
  • This study was carried out to investigate the effect of welding parameters such as shielding gas compositions welding voltage and welding current on the pore formation in the weld beads of galvanized steel pipes produced with gas metal arc welding. The porosity was evaluated and rated by metallography and radiographic test in terms of weight percentage, number and distribution of pores in weld beads. The porosity increased with increasing welding voltage and current, in which Ar gas produced the most porosity while $Ar+5%O_2$ generated the least porosity. It was found that the porosity could be reduced by selection of the proper gas mixture composition such as $Ar+5%O_2$ and $Ar+10%CO_2$ and by using current (130~150A) and voltage(16~20V).

아연도금강판 겹치기 용접부에 대한 2패스 레이저용접 적용성 연구 (Applicability Study of 2-pass Laser Welding on Galvanized Steel Sheets)

  • 안영남;강민정;김철희
    • Journal of Welding and Joining
    • /
    • 제34권4호
    • /
    • pp.55-61
    • /
    • 2016
  • During laser overlap welding of galvanized steel sheets, explosion of weld pool by the high pressure zinc vapor induces weld defects like porosity and blowhole. In this study, laser 2-pass welding was implemented to prevent the weld defects. Through the 1st pass welding, zinc layers on the faying surfaces were removed when proper heat input was applied. Excessive heat input could result in explosion even during the 1st pass welding and insufficient heat input could not remove enough region of zinc layer for the 2nd pass welding. Coating weights of $45g/m^2$ and $60g/m^2$ were considered and for both cases sound welds without weld defects could be achieved. In spite of 2-pass welding, softening of weld and heat affected zone was not observed and Zn coating was not diluted into the weld metal.