• Title/Summary/Keyword: Gain-switching

Search Result 282, Processing Time 0.027 seconds

Practical Implementation of Memristor Emulator Circuit on Printed Circuit Board (PCB에 구현한 멤리스터 에뮬레이터 회로 및 응용)

  • Choi, Jun-Myung;Sin, SangHak;Min, Kyeong-Sik
    • Journal of IKEEE
    • /
    • v.17 no.3
    • /
    • pp.324-331
    • /
    • 2013
  • In this paper, we implemented memristor emulator circuit on Printed Circuit Board (PCB) and observed the inherent pinched hysteresis characteristic of memristors by measuring the emulator circuit on PCB. The memristor emulator circuit implemented on PCB is composed of simple discrete devices not using any complicated circuit blocks thus we can integrate the memristor emulator circuits in very small layout area on Silicon substrate. The programmable gain amplifier is designed using the proposed memristor emulator circuit and verified that the amplifier's voltage gain can be controlled by programming memristance of the emulator circuit by circuit simulation. Threshold switching is also realized in the proposed emulator circuit thus memristance can remain unchanged when the input voltage applied to the emulator circuit is lower than VREF. The memristor emulator circuit and the programmable gain amplifier using the proposed circuit can be useful in teaching the device operation, functions, characteristics, and applications of memristors to students when thet cannot access to device and fabrication technologies of real memristors.

Preliminary study on a 3D field permanent magnet flux switching machine - from tubular to rotary configurations

  • Wang, Can-Fei;Shen, Jian-Xin
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.4
    • /
    • pp.505-508
    • /
    • 2012
  • A permanent magnet flux switching (PMFS) machine has a simple rotor, whilst both magnets and coils are set in the stator, resulting in easy removal of heat due to both copper loss and eddy current loss in magnets. However, the volume of magnets used in PMFS machines is usually larger than in conventional PM machines, and leakage flux does exist at the non-airgap side. To make full use of the magnets and gain higher power density, a novel 3-dimensional (3D) field PMFS machine is developed. It combines merits of the tubular linear machine, external-rotor rotary machine and axial-flux rotary machine, hence, offers high power density and peak torque capability, as well as efficient utility of magnets owing to the unique configuration of triple airgap fields.

A New Soft Switching Step-Down/Up Converter with Inherent PFC Performance

  • Jabbari, Masoud;Farzanehfard, Hosein
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.835-844
    • /
    • 2009
  • In this paper a new buck-boost type DC-DC converter is presented. Its voltage gain is positive, all active elements operate under soft-switching condition independent of loading, magnetic isolation and self output short-circuit protection exist, and very fast dynamic operation is achievable by a simple bang-bang controller. This converter also exhibits appropriate PFC characteristics since its input current is inherently proportional to the source voltage. When the voltage source is off-line, it is sufficient to add an inductor after the rectifier, then near unity power factor is achievable. All essential guidelines to design the converter as a DC-DC and a PFC regulator are presented. Simulation and experimental results verify the developed theoretical analysis.

A Study on a Carrier Based PWM having Constant Common Mode Voltage and Minimized Switching Frequency in Three-level Inverter

  • Ahn, Kang-Soon;Choi, Nam-Sup;Lee, Eun-Chul;Kim, Hee-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.393-404
    • /
    • 2016
  • In this paper, a carrier-based pulse with modulation (PWM) strategy for three-phase three-level inverter is dealt with, which can keep the common mode voltage constant with minimized switching frequency. The voltage gain and the switching frequency in overall operating ranges including overmodulation are investigated and the analytic equations are presented. Finally, the leakage current reduction effect is confirmed by carrying out simulation and experiment. It will be pointed out that the leakage current cannot be perfectly eliminated because of the dead time.

A Study on the Fault-Tolerant and Bumpless Switching Control for Boiler Systems in the Power Plant (발전용 보일러 시스템의 이상허용 및 과도상태의 유연한 제어에 관한 연구)

  • Kwon, Oh-Kyu;Lee, Young-Sam
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.1037-1040
    • /
    • 1998
  • In this research a fault-tolerant and bumpless switching control is proposed for boiler systems used in the power plants. Firstly, three operating points are selected to control the nonlinear boiler through the full operational range, and the $H_{\infty}$ loop shaping controller and the model-based predictive controller(MBPC) are designed. To prevent the windup and bump problems which are caused by the actuator saturation and the controller switching, an anti-windup and bumpless transfer technique is adopted to the $H_{\infty}$ loop shaping controller. Also the constrained gain-scheduling technique is applied to MBPC to achieve the same objective. Secondly, the fault-tolerant control technique is proposed to continue the control action without stopping the boiler operation even in case of some faults. Through various simulation studies, the performances of the proposed control techniques are demonstrated.

  • PDF

A Study on Switching Shunt Regulator for Satellite Power System

  • Park, Jae-dong;Seong, Se-Jin
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.1
    • /
    • pp.14-20
    • /
    • 1998
  • The resistive shunting for the fine control of a Direct Energy Transfer(DET) systems is fully developed, but the non-resistive shunting using variable size solar array segments is in progress. This paper presents the spacecraft power control through switching of solar array segments, which uses a fully regulated DET power regulation. This method eliminates a dissipative element and removes the associated design limitations which arise from the dissipative elements for radiating cooling in deep space. The switching shunt regulator comprises the switched Solar Array Shunt(SAS) modules that regulate the solar array power. These SAS modules connect/disconnect the solar array segments to/from the bus according to the loading in the main bus without significant variations in the dissipation level. In this paper, twelve segments are used in the shunting. In order to verify the basis of analysis, the computational result of an analytic loop gain is performed.

  • PDF

The Effect of Switching Dead Time on the Output of Inverter (스위칭 데드타임이 인버터 출력에 미치는 영향)

  • You, Wan-Sik;Park, Jong-Kwan;Oh, Won-Seok;Cho, Kyu-Min
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2708-2711
    • /
    • 1999
  • The dead time which is inserted in switching signals of PWM voltage source inverters distorts its output. As a result, the deviations of real fundamental voltage and phase compared with the reference are occurred. And also the harmonics on its output are increased. In this paper, numerical analysis of the error voltage on the output of inverter according to the switching dead time is presented. And the calculation results of fundamental voltage gain and phase deviations are presented

  • PDF

A Dual PID Controller for High-Accuracy Positioning of Ink Jet Printer Media Advance System (잉크젯 프린터 용지 이송 장치의 정밀 위치 제어를 위한 이중 PID 제어기의 설계)

  • 조영완
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.4
    • /
    • pp.317-324
    • /
    • 2004
  • The ink jet printer media advance system is required to be exactly driven to the target position via tracking the reference velocity profile to obtain the high quality print image. A single gain PID controller is not sufficient to fulfill the control objectives, the exact velocity tracking and the accurate positioning, at the same time. A dual PID controller and its switching strategy are presented in this paper to achieve the control objectives. The media advance system is controlled by two separate PID controllers, one of which is for velocity control, and the other is for position control. A PID controller controls the velocity of the media advance system until it reaches the predetermined switching position. When the media advance system passes the predetermined position, the controller is switched to the other PID controller which is more profitable for exact positioning. The switching position is determined by the estimated stop distance. The simulation and experimental results are presented to show the validity and effectiveness of the proposed controller.

Interleaved Current-fed High Step-up DC-DC Converter (인터리브드된 전류 주입형 고승압 DC-DC 컨버터)

  • Lee, Junho
    • Journal of IKEEE
    • /
    • v.24 no.2
    • /
    • pp.586-591
    • /
    • 2020
  • An interleaved current-fed high step-up DC-DC converter is proposed. Besides high voltage gain, a low ripple input current is achieved by adopting interleaving operation. Moreover, soft-switching characteristic of the proposed converter reduces switching losses of active power switches and raise the conversion efficiency. The reverse-recovery problem of output rectifiers is also alleviated by controlling the current changing rates of diodes by utilizing the leakage inductances of transformers. Experimental results obtained on a 200W prototype are discussed.

Analysis of the Errors on the Output voltage of Inverter Caused by Switching Dead Time (스위칭 데드타임에 의한 인버터 출력 전압의 오차 해석)

  • Cho, Kyu-Min
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.11
    • /
    • pp.120-127
    • /
    • 1999
  • The dead time which is inserted in switching signals of PWM voltage source inverters distorts its output. As a result, the deviations of real fundamental voltage and phase compared with the reference are occurred. And also the harmonics on its output are increased. In this paper, numerical analysis of the distorted voltage on the output of inverter caused by switching dead time is performed. With the calculation results, the fundamental voltage gain and phase deviations according to the modulation index, load displacement factor and dead time are presented.

  • PDF