Er이 도핑된 졸-겔 코팅막의 발광특성 (Near IR Luminescence Properties of Er-doped Sol-Gel Films)

  • Lim, Mi-Ae;Seok, Sang-Il;Kim, Ju-Hyeun;Ahn, Bok-Yeop;Kwon, Jeong-Oh
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2003년도 추계학술발표강연 및 논문개요집
    • /
    • pp.136-136
    • /
    • 2003
  • In fiber optic networks, system size and cost can be significantly reduced by development of optical components through planar optical waveguides. One important step to realize the compact optical devices is to develop planar optical amplifier to compensate the losses in splitter or other components. Planar amplifier provides optical gain in devices less than tens of centimeters long, as opposed to fiber amplifiers with lengths of typically tens of meters. To achieve the same amount of gain between the planar and fiber optical amplifier, much higher Er doping levels responsible for the gain than in the fiber amplifier are required due to the reduced path length. These doping must be done without the loss of homogeniety to minimize Er ion-ion interactions which reduce gain by co-operative upconversion. Sol-gel process has become a feasible method to allow the incorporation of Er ion concentrations higher than conventional glass melting methods. In this work, Er-doped $SiO_2$-A1$_2$ $O_3$ films were prepared by two different method via sol -Eel process. Tetraethylorthosilicate(TEOS)/aluminum secondary butoxide [Al (OC$_4$ $H_{9}$)$_3$], methacryloxypropylcnethoxysaane(MPTS)/aluminum secondary butofde [Al(OC$_4$ $H_{9}$)$_3$] systems were used as starting materials for hosting Er ions. Er-doped $SiO_2$-A1$_2$ $O_3$ films obtahed after heat-treating, coatings on Si substrate were characterized by X-ray din action, FT-IR, and N-IR fluorescence spectroscopy. The luminescence properties for two different processing procedure will be compared and discussed from peak intensity and life time.

  • PDF

E-Band Wideband MMIC Receiver Using 0.1 ${\mu}m$ GaAs pHEMT Process

  • Kim, Bong-Su;Byun, Woo-Jin;Kang, Min-Soo;Kim, Kwang Seon
    • ETRI Journal
    • /
    • 제34권4호
    • /
    • pp.485-491
    • /
    • 2012
  • In this paper, the implementations of a $0.1{\mu}m$ gallium arsenide (GaAs) pseudomorphic high electron mobility transistor process for a low noise amplifier (LNA), a subharmonically pumped (SHP) mixer, and a single-chip receiver for 70/80 GHz point-to-point communications are presented. To obtain high-gain performance and good flatness for a 15 GHz (71 GHz to 86 GHz) wideband LNA, a five-stage input/output port transmission line matching method is used. To decrease the package loss and cost, 2nd and 4th SHP mixers were designed. From the measured results, the five-stage LNA shows a gain of 23 dB and a noise figure of 4.5 dB. The 2nd and 4th SHP mixers show conversion losses of 12 dB and 17 dB and input P1dB of -1.5 dBm to 1.5 dBm. Finally, a single-chip receiver based on the 4th SHP mixer shows a gain of 6 dB, a noise figure of 6 dB, and an input P1dB of -21 dBm.

이득 포화된 광섬유증폭기를 사용하는 기상에 둔감한 무선광통신 (Weather-insensitive Optical Free-space Communication Using the Gain-Saturated Optical Fiber Amplifier)

  • 신경운;허윤석;이상훈;이재승
    • 한국광학회지
    • /
    • 제17권5호
    • /
    • pp.396-400
    • /
    • 2006
  • 본 논문은 광 패킷 채널을 전송하는 기상에 둔감한 무선광통신방법을 제안한다. 이 방법은 광 패킷 채널들을 광섬유증폭기의 포화영역에서 증폭한다. 전송손실이 증가하면, 평균 패킷의 속도나 평균 패킷의 길이를 줄여서, 자유공간에 입력되는 광파워 레벨을 증가시킨다. 실험으로, $8{\times}10$ Gigabit Ethernet 채널을 자유공간에서 2.4 km 전송하였다. 또한 자유공간에서 광 패킷 채널을 중계하기 위하여 1.2 km 지점에 한 개의 이득포화 광중계기를 사용하였다.

십자 슬롯을 이용한 광대역 원형편파 적층 개구결합 마이크로스트립 안테나 (Wide Bandwidth Circularly Polarized Aperture Coupled Microstrip Antenna using Cross-slot)

  • 양태식;이범선
    • 한국전자파학회논문지
    • /
    • 제11권5호
    • /
    • pp.748-754
    • /
    • 2000
  • 단일 급전구조를 갖는 새로운 구조의 십자슬롯 결합 광대역 원형판의 적층 마이크로스트립 안테나를 설계, 제작하고 측정하였다. 설계된 단일 방사소자의 10dB 반사손실 대역폭은 34.5%(9.45~13.54GHz), 3dB 축비 대역폭은 18.7%(11.17~13.39GHz), 6dB 이득 대역폭은 29% (10.21~13.64GHz)로 광대역 특성을 갖는다. 순차적 회전 배열방식을 이용하여 설게한 2$\times$2배열 안테나의 10dB 반사손실 대역폭은 35.9%(9.69~13.94GHz), 3dB 축비 대역폭은 34.6GHz (9.93~14.03GHz), 12dB 이득 대역폭은 27.4%(10.35~13.6GHz)로 더욱 개선된 광대역 특성을 갖는다. 이 방법을 이용하여 확장된 8$\times$8 배열 안테나를 제작하여 측정한 결과, 10dB 반사손실 대역폭은 27.3%(10.17~13.41GHz), 3dB 축비 대역폭은 27.9%(10.1~13.4GHz)로 나타났고, 방사패턴은 이론에 의한 것과 거의 일치하였다. 이 안테나는 Ku 대역에서 광대역 응용이 필요한 분야의 통신 또는 방송 안테나로 사용될 수 있다.

  • PDF

의복형태에 따른 성인여성의 발한반응에 관한 연구 (The Study on the Sweating Responses of Adult Female according to Garment types)

  • 염희겅;최정화
    • 한국의류학회지
    • /
    • 제16권4호
    • /
    • pp.405-416
    • /
    • 1992
  • This study was performed to investigate correlation between total body weight loss and local sweat rate and to find out any possible method that can estimate total body weight loss judging from local sweat rate. Twelve adult females were kept at 44 $\pm1^{\circ}C$, 50 ${\pm}5\%$ R.H. (1) Physiological responses such as total body weight loss, local sweat rate, rectal temperature, skin temperature, blood pressure and pulse, (2) micro climate inside garment and (3) subjective sensation were examined. Two types of garment such as long-sleeves with long pants (Type I) and half·sleeves with short pants (Type II) were used to observe the effect of garment types on sweating response. Both clothing weight was equal (132$\pm$3 g/$m^{2}$). The results were as follows: 1. Regardless of the different types, total body weight loss was more interrelated with the sweat rate on forehead than any other parts of the body. Except the forehead, different parts of body with different types of garment influenced on body weight loss quite differently. 2. Total body weight loss was more interrelated with the weight gain of garment than the local sweat rate. 3. Under the environment of 44$\pm1^{\circ}C,\;50{\pm}5\%$R.H., body weight loss during 1 hour of subject clothed and silted was 275.2 g/hr and weight loss per body surface area was 178.9 g/$m^{2}/hr$ Garment types have no influences on total body weight loss. 4. Local sweat rate (mg/7.07 $cm^{2}/hr$) was 208.0,191.0, 133.0, 115.0,81 0, 75.1 and 66.3 on scruff, breast, forehead, forearm, thigh, upper arm, leg respectively No evidence has been found that garment types influenced on local sweat rate (p<0.1). 5. No interrelationships between rectal temperature and total body weight loss, local skin temperature and total body weight loss, and local skin temperature and local sweat rate were found. From this study, some possible method that we can estimate total body' weight loss judging from weight loss of garment. But considering the fact that clothing design factor, the physical characteristics of fabric and environmental factor such as humidity and wind velocity should be concerned in weight loss of garment, it should be studied further whether the total body weight loss can be estimated properly from the weight loss of garment. This experiment suggest that different parts of body with different types of garment can influence on body weight loss quite differently. Therefore, in order to get more precise results, more studies under the diversity of garment types should be done in the near future.

  • PDF

Preliminary study on a 3D field permanent magnet flux switching machine - from tubular to rotary configurations

  • Wang, Can-Fei;Shen, Jian-Xin
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권4호
    • /
    • pp.505-508
    • /
    • 2012
  • A permanent magnet flux switching (PMFS) machine has a simple rotor, whilst both magnets and coils are set in the stator, resulting in easy removal of heat due to both copper loss and eddy current loss in magnets. However, the volume of magnets used in PMFS machines is usually larger than in conventional PM machines, and leakage flux does exist at the non-airgap side. To make full use of the magnets and gain higher power density, a novel 3-dimensional (3D) field PMFS machine is developed. It combines merits of the tubular linear machine, external-rotor rotary machine and axial-flux rotary machine, hence, offers high power density and peak torque capability, as well as efficient utility of magnets owing to the unique configuration of triple airgap fields.

Stochastic value index for seismic risk management of existing lifelines

  • Koike, Takeshi;Imai, Toshio
    • Structural Engineering and Mechanics
    • /
    • 제32권1호
    • /
    • pp.147-165
    • /
    • 2009
  • This study proposes a certain measure or investment strategy for decision making associated with seismic retrofitting. This strategy reduces the risk of a large-scale malfunction such as water supply loss under seismic risks. The authors developed a stochastic value index that will be used in the overall evaluation of social benefit, income gain, life cycle costs and failure compensation associated with existing lifeline systems damaged by an earthquake during the remaining service period. Optimal seismic disaster prevention investment of deteriorated lifeline systems is discussed. Finally, the present study provides a performance-based design method for seismic retrofitting strategies of existing lifelines which are carried out using the target probabilities of value loss and structural failure.

마이크로파 곡물함수율 측정을 위한 새로운 밀도보정방법 (New Density-Independent Model far Microwave Measurement of Grain Moisture Content)

  • 김종헌;김기복;노상하
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.229-232
    • /
    • 1997
  • A free space transmission method using standard gain horn antennas in the frequency range from 9.0 to 10.5GHz is applied to determine the dielectric properties of grain such as rough rice, brown rife and barley. The dielectric constant and loss factor, which depend on the moisture content of the wetted grain are obtained from the measured attenuation and phase shift by vector network analyzer. The effect of density fluctuation, which is an important parameter governing the dielectric properties of grain, on the dielectric constant and loss factor is presented. A new density-independent model in terms of measured attenuation and moisture density is proposed for reducing the effects of density fluctuation on the moisture content measurement.

  • PDF

Design and Performances of Implantable CPW Fed Apollian Shaped Antenna at 2.45 GHz ISM Band for Biomedical Applications

  • Kumar, S. Ashok;Sankar, J. Navin;Dileepan, D.;Shanmuganantham, T.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권5호
    • /
    • pp.250-253
    • /
    • 2015
  • A novel implantable CPW fed Apollian shaped antenna embedded into human tissue is proposed for ISM band biomedical applications. The proposed antenna is made compatible for implantation by embedding it in an alumina ceramic substrate(εr=9.8 and thickness= 0.65 mm). The proposed antenna covers the ISM band of 2.45 GHz. The radiation parameters such as return loss, xy-plane, xz-plane, and yz-plane etc., are measured and analyzed using the agilent vector network analyzer. The proposed antenna has substantial advantages, including low profile, miniaturization ability, lower return loss, better impedance matching, and high gain over conventional implanted antennas.

New Density-Independent Model for Measurement of Grain Moisture Content using Microwave Techniques

  • Kim, Jong-Heon;Kim, Ki-Bok;Noh, Sang-Ha
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권4호
    • /
    • pp.72-78
    • /
    • 1997
  • A free space transmission method using standard gain horn antennas in the frequency range from 9.0 to 10.5GHz is applied to determine the dielectric properties of grain such as rough rice ,brown rice and barley. The dielectric constant and loss factor, which depend on the moisture content of the wetted grain are obtained from the measured attenuation and phase shift by vector network analyzer. The moisture content of grain varied from 11 to 25% based on this wetted condition. The measured values of dielectric constants as a function of moisture density are compared with values of those obtained using he predicted model for estimating dielectric constants of grain. The effect of density fluctuation, high is an important parameter governing the dielectric properties of grain, on the dielectric constant and loss factor is presented. A new density-independent model in terms of measured attenuation an moisture density is proposed of reducing the effects of density fluctuation on the moisture content measurement.

  • PDF