• Title/Summary/Keyword: GacA

Search Result 236, Processing Time 0.031 seconds

Analysis of Enterococcus faecalis Attachment to Granular Activated Carbon with a Column Experiment (칼럼실험에 의한 입상활성탄에서 Enterococcus faecalis의 부착 연구)

  • Kim, Hyon-Chong;Park, Seong-Jik;Lee, Chang-Gu;Han, Yong-Un;Kim, Song-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.2
    • /
    • pp.119-124
    • /
    • 2009
  • The aim of this study was to investigate the influence of ionic strength and iron impregnation on the attachment of Enterococcus faecalis to granular activated carbon (GAC). Column experiments were performed to examine bacterial adhesion to coconutbased GAC (c-GAC), iron-impregnated c-GAC (fc-GAC), acid-washed c-GAC (a-GAC) and iron-impregnated a-GAC (fa-GAC) under two different solution (NaCl 1, 10 mM) conditions. Results showed that bacterial mass recovery in c-GAC decreased from 77.3 to 61.6% while in a-GAC it decreased from 71.6 to 32.3% with increasing ionic strength from 1 to 10 mM. This indicates that bacterial attachment to GAC can be enhanced with increasing ionic strength. Results also showed that the mass recoveries in fc-GAC were 62.6% (1 mM) and 53.3% (10 mM) while they were 50.8% (1 mM) and 16.9%(10 mM) in fa-GAC, which were lower than those in c-GAC and a-GAC. This demonstrates that bacterial adhesion to GAC can be enhanced through iron impregnation. This study provides information regarding the effects of ionic strength and iron impregnation on bacterial attachment to GAC. Furthermore, this study will advance our knowledge of bacterial removal in surface-modified granular media.

A Study on the Characteristics of Activated Carbons Supported Metal by Microwave Irradiation (마이크로파 조사에 따른 금속이 담지 된 활성탄의 특성 연구)

  • Kim, Sung-Wook;Kim, Jung-Bae;Choi, Sung-Woo
    • Journal of Environmental Science International
    • /
    • v.18 no.5
    • /
    • pp.501-508
    • /
    • 2009
  • In this study, the characteristics of granular activated carbon (GAC) supported metal was investigated in an area influenced by flame discharge and temperature variation during irradiating microwave. The modified GAC was formulated by impregnating metal hydroxides of nickel (Ni/GAC), barium (Ba/GAC), copper (Cu/GAC), zinc (Zn/GAC), cobalt (Co/GAC) and lanthanum (La/GAC). Ba/GAC was selected as it showed lack of spark discharge and temperature increasing aspects. Comparison of adsorption and desorption amount of GAC and Ba/GAC showed that adsorption and desorption rate of the GAC were higher than those of Ba/GAC. The results show that the presence of barium can decrease adsorption/desorption rate because of plugging pore of GAC. Toluene regeneration rate of Ba/GAC was better than that of GAC due to barium loading. Finally, GAC with barium can be controled a rapid increasing temperature and spark discharge, increased the regeneration rate of toluene during desorption by irradiating microwave.

Temperature Characteristics of the Modified GAC by Microwave Irradiation and Benzene Adsorption (마이크로파 조사에 따른 개질화 활성탄의 온도특성 및 벤젠흡착)

  • Choi Sung-Woo;Kim Yoon-Kab
    • Journal of Environmental Science International
    • /
    • v.15 no.6
    • /
    • pp.579-586
    • /
    • 2006
  • The purposes of this paper were to monitor the temperature rising courses and spark discharge of the modified granular activated carbon (GAC) by microwave (MW) irradiation and to evaluate absorption of benzene. The GAC coated on $SiO_2$, boron, talc, ferrite was named as the modified GAC. Thermal and spark discharge measurement of virgin GAC and modifed GAC has been carried out using a MW device operating at 2450 MHz under various energy conditions. The results of this paper as follows. First, the modified GAC is more efficient than the virgin GAC in temperature control. Temperature gradient of the modified GAC is more lower than that of virgin GAC. The temperature gradient of GAC was observed in the following order : virgin GAC, Mn-Zn ferrite/GAC, Ni-Zn ferrite,/GAC, $SiO_2/GAC$, Boron/GAC, Talc/GAC. Second, the spark discharge of the modified GAC was diminished, compared with that of virgin GAC. Because of its excellent electrical insulating properties, the coating material prevents the spark discharge. Finally, the benzene adsorption capacity of the modified GAC decreased due to diminishing of adsorption site by the coating material. Considering the temperature gradient and spark discharge of GAC, the GAC coated $SiO_2$ would be appropriate absorbent under irradiation of MW.

Proteomic Analysis of the GacA Response Regulator in Pseudomonas chlororaphis O6

  • Anderson, Anne J.;Kim, Young Cheol
    • Research in Plant Disease
    • /
    • v.24 no.2
    • /
    • pp.162-169
    • /
    • 2018
  • The GacS/GacA system in the root colonizer Pseudomonas chlororaphis O6 is a key regulatory system of many traits relevant to the plant probiotic nature of this bacterium. The work in this paper elucidates proteins using proteomics approach in P. chlororaphis O6 under the control of the cytoplasmic regulatory protein, GacA. A gacA mutant of P. chlororaphis O6 showed loss in production of phenazines, acyl homoserine lactones, hydrogen cyanide, and protease, changes that were associated with reduced in vitro antifungal activity against plant fungal pathogens. Production of iron-chelating siderophore was significantly enhanced in the gacA mutant, also paralleling changes in a gacS mutant. However, proteomic analysis revealed proteins (13 downregulated and 7 upregulated proteins in the mutant compared to parental strain) under GacA control that were not apparent by a proteomic study of a gacS mutant. The putative identity of the downregulated proteins suggested that a gacA mutant would have altered transport potentials. Notable would be a predicted loss of type-VI secretion and PEP-dependent transport. Study of mutants of these GacA-regulated proteins will indicate further the features required for probiotic potential in this rhizobacterium.

The Sensor Kinase GacS Negatively Regulates Flagellar Formation and Motility in a Biocontrol Bacterium, Pseudomonas chlororaphis O6

  • Kim, Ji Soo;Kim, Yong Hwan;Anderson, Anne J.;Kim, Young Cheol
    • The Plant Pathology Journal
    • /
    • v.30 no.2
    • /
    • pp.215-219
    • /
    • 2014
  • The GacS/GacA two component system regulates various traits related to the biocontrol potential of plant-associated pseudomonads. The role of the sensor kinase, GacS, differs between strains in regulation of motility. In this study, we determined how a gacS mutation changed cell morphology and motility in Pseudomonas chlororaphis O6. The gacS mutant cells were elongated in stationary-phase compared to the wild type and the complemented gacS mutant, but cells did not differ in length in logarithmic phase. The gacS mutant had a two-fold increase in the number of flagella compared with the wild type strain; flagella number was restored to that of the wild type in the complemented gacS mutant. The more highly flagellated gacS mutant cells had greater swimming motilities than that of the wild type strain. Enhanced flagella formation in the gacS mutant correlated with increased expression of three genes, fleQ, fliQ and flhF, involved in flagellar formation. Expression of these genes in the complemented gacS mutant was similar to that of the wild type. These findings show that this root-colonizing pseudomonad adjusts flagella formation and cell morphology in stationary-phase using GacS as a major regulator.

Sorption of ο-Cresol by Granular Activated Carbon (GAC) and Abiotic Transformation on GAC Surface (입상활성탄에 의한 오르토크레졸(ο-cresol)의 흡착과 비생물학적 변형)

  • 한인섭;김용환
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.1
    • /
    • pp.87-94
    • /
    • 2004
  • The effects of pretreatment of GAC and dissolved oxygen (DO) on the sorption capacity for ο-cresol were investigated using pretreated GAC under oxic and anoxic conditions. Virgin GAC was used with pretreated GACs by $O_2$, acid and base as sorbents. Sorption capacity of GAC was dependent on the oxygen conditions according to the pretreatment methods. Virgin GAC showed increased sorption capacity when DO was present in the solution, while $O_2$-pretreated GAC did not show any considerable capacity change. Acid- and base-pretreated GACs were relatively more influenced by presence of DO as compared with virgin GAC. Both acid and base-pretreated GACs showed a rapid sorption rate at the initial stage, but as contact time became longer the sorption was slower. Sorbed ο-cresol was extracted with micro-Soxhlet extraction apparatus using the GAC separated from the rate experiments. Within 1 hour both acid and base-pretreated GACs showed the decrease in extraction efficiencies under both oxic and anoxic conditions. After 1 hour such a trend (the increase as contact time was longer) was not observed and showed relatively constant efficiencies of 35∼50%. According to the results of this study $O_2$contacted with GAC before sorption as well as DO present in the solution during sorption could influence the GAC sorption capacity.

Toluene Desorption of Modified Activated Carbon for Microwave Irradiation (마이크로파조사를 위한 개질화 활성탄의 톨루엔 탈착)

  • Choi, Sung-Woo;Chu, Heon-Jik
    • Journal of Environmental Science International
    • /
    • v.20 no.2
    • /
    • pp.223-229
    • /
    • 2011
  • Toluene desorption of modified activated carbon for microwave irradiation was evaluated. As a virgin GAC reacted from microwave energy, it created an "arcing" between GAC particles in desorption process. The arcing became more and more vigorous and achieved a red flame of GAC. The silica coated GAC(Si/GAC) was developed to prevent arcing phenomenon and temperature control problem. The result shows virgin GAC with 5wt%, 10wt% and 20wt% silica had no arcing and could control temperature very well. However, the adsorption rate of Si/GAC was decreased by coated silica amount due to decreasing surface area of GAC. The 5wt% Si/GAC adsorption rate was quite similar to virgin GAC adsorption rate. After adsorption, the toluene-loaded GAC and Si/GAC was reactivated by 2450MHz MW irradiation with 300W for 5 min. Quantitative desorption of the toluene was achieved at MW irradiation at 300W with desorption efficiencies as high as 98.59% to 84.65%% after four cycles.

Effect of gacS and gacA Mutations on Colony Architecture, Surface Motility, Biofilm Formation and Chemical Toxicity in Pseudomonas sp. KL28

  • Choi, Kyung-Soon;Veeraragouda, Yaligara;Cho, Kyoung-Mi;Lee, Soo-O;Jo, Geuk-Rae;Cho, Kyung-Yun;Lee, Kyoung
    • Journal of Microbiology
    • /
    • v.45 no.6
    • /
    • pp.492-498
    • /
    • 2007
  • GacS and GacA proteins form a two component signal transduction system in bacteria. Here, Tn5 transposon gacS and gacA (Gac) mutants of Pseudomonas sp. KL28, an alkylphenol degrader, were isolated by selecting for smooth colonies of strain KL28. The mutants exhibited reduced ability to migrate on a solid surface. This surface motility does not require the action of flagella unlike the well-studied swarming motility of other Pseudomonas sp. The Gac mutants also showed reduced levels of biofilm and pellicle formation in liquid culture. In addition, compared to the wild type KL28 strain, these mutants were more resistant to high concentrations of m-cresol but were more sensitive to $H_2O_2$, which are characteristics that they share with an rpoS mutant. These results indicate that the Gac regulatory cascade in strain KL28 positively controls wrinkling morphology, biofilm formation, surface translocation and $H_2O_2$ resistance, which are important traits for its capacity to survive in particular niches.

Evaluation of Physical Properties and Adsorption Capacity of Regeneration GAC (재생 활성탄의 물성 및 흡착능 평가)

  • Mun, Ji-Young;Chae, Seon-Ha;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.4
    • /
    • pp.407-416
    • /
    • 2009
  • The objective of this study was to evaluate the variation of physical properties and adsorption capacity after regeneration of Granular Activated Carbon (GAC). It was found that the loss rate of regenerated carbon was related to the usage time of GAC. The correlations between iodide number and loss rate also determined. Effective size and uniformity coefficient for regenerated GAC were within a similar range compared to virgin GAC. This result indicated that the function as media is recovered. Although iodide number and specific surface area for regenerated GAC were not completely recovered compared to that of virgin GAC, cumulative pore volumes of regenerated GAC were increased. Removal efficiency of organic matter in regenerated GAC was resulted the same or slightly higher than that of virgin GAC. This result indicates that the number of mesopore responsible for removal of organic matter was increased after regeneration.

Effect of Ozonation on Removal of Dissolved Organic Matter by Granular Activated Carbon Process (오존공정이 입상활성탄공정에서 용존유기물질의 제거에 미치는 영향)

  • Ahn, Hyo-Won;Chae, Seon-Ha;Wang, Chang-Keun;Lim, Jae-Lim
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.6
    • /
    • pp.601-608
    • /
    • 2008
  • The objective of this study was to evaluate the effect of ozonation as pretreatment on the removal of dissolved or biodegradable organic matter(DOM or BOM), the variance of DOM fractionation, and microbial regrowth by pilot-scale granular activated carbon processes in which adsorption and biodegradability was proceeding due to long time operation. Regardless of point of ozonation applied, GAC processes with ozonation(i.e., Ozonation combined with GAC Filter-adsorber; Pre O$_3$ + F/A, Ozonation combined with GAC adsorber; Post O$_3$ + GAC) compared with GAC processes without ozonation(i.e., GAC Filter-adsorber; F/A, GAC adsorber; GAC) removed approximately 10 to 20% more of DOC, hydrophilic DOM(HPI), BDOC and AOC after long period of operation that biological activity was assumed to happen. Ozonation was not found to have a significant effect on the removal of DOC, but caused the decrease of AOC by approximately 20%. It was found that the fixed bacterial biomass on GAC media did not show a significant difference between the GAC with ozonation and GAC without ozonation as pre-treatment, whereas the HPC of column effluent was more biostable at Post O$_3$ + GAC compared with F/A or GAC.