• Title/Summary/Keyword: GUL

Search Result 1,119, Processing Time 0.025 seconds

The Characteristics and Improvement Directions of Regional Climate Change Adaptation Policies in accordance with Damage Cases (지자체 기후변화 적응 대책 특성 및 개선 방향)

  • Ahn, Yoonjung;Kang, Youngeun;Park, Chang Sug;Kim, Ho Gul
    • Journal of Environmental Impact Assessment
    • /
    • v.25 no.4
    • /
    • pp.296-306
    • /
    • 2016
  • There is a growing interest in establishing a regional climate change adaptation policy as the climate change impact in the region and local scale increases. This study focused on the analysis of 32 regions on its characteristics of local climate change adaptation plans. First, statistic program R was used for conducting cluster analysis based on the frequency and budgets of adaptation plan. Further, we analyzed damage frequency from newspapers regarding climate change impacts in eight categories which were caused by extreme weather events on 2,565 cases for 24 years. Lastly, the characteristics of climate change adaptation plan was compared with damage frequency patterns for evaluating the adequacy of climate change adaptation plan on each cluster. Four different clusters were created by cluster analysis. Most clusters clearly have their own characteristics on certain sectors. There was a high frequency of damage in 'disaster' and 'health' sectors. Climate change adaptation plan and budget also invested a lot on those sectors. However, when comparing the relative rate among regional governments, there was a difference between types of damage and climate change adaptation plan. We assumed that the difference could come from that each region established their adaptation plans based on not only the frequency of damage, but vulnerability assessment, and expert opinions as well. The result of study could contribute to policy making of climate change adaptation plan.

Clinical and Therapeutic Aspects of Squamous Cell Carcinoma of Oral Tongue (구강 설 편평 상피 세포암의 임상적, 치료적 고찰)

  • Ryu Samuel;Lee Chang Gul;Park In Kyu;Suh Chang Ok;Kim Gwi Eon;Loh John J.K.
    • Radiation Oncology Journal
    • /
    • v.5 no.2
    • /
    • pp.105-110
    • /
    • 1987
  • Fourty nine patients with squamous cell carcinoma of oral tongue were reviewed retrospectively for the evaluation of clinical manifestation and for the comparison between therapeutic modalites. The gross shape of the tumor was infiltrative in 22, ulcerative in 12, ad ulcer-oinfiltrative type in 10 patients. Direct extension of the tumor was most commonly to the floor of the mouth. The incidence of nodal metastasis generally increased with tumor stage. $55\%$ of the patients showed neck nodal metastasis at the time of diagnosis. Ipsilateral subdigastric node were most commonly involved, followed by submandibular nodes. The 5-year survival rate of patients treated with surgery and radiotherapy was $58.7\%$ in contrast to $21.6\%$ in radiation alone group. Overall 5-year survival rate was $31\%$ In radiation alone group, half of the patients in stage I, II were locally controlled. But the local control In stage III, IV was much inferior to early lesions. Especially, of 4 patients combined with implantation technique, 3 were completely controlled. 5-year survival rate of these implanted patients was $50\%,\;49.4\%$ of patients treated over 7,000cGy survived 5 years. This was significant in contrast to $6.4\%$ of the group treated below 7,000cGy. The most common sites of failures were primary sites. In early lesions primary radiotherapy with implantation would be an appropriate treatment in cancer of oral tongue, operation reserved for radiation failure. Operation and adjuvant radiotherapy is recommended in cases of advanced disease.

  • PDF

Study on Derivation of Fourth-Order GIUH and Revision of Initial State Probability (4차 하천에서의 GIUH의 유도 및 초기확률의 보정에 관한 연구)

  • Ham, Dae-Heon;Joo, Jin-Gul;Jun, Hwan-Don;Kim, Joong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.2
    • /
    • pp.229-239
    • /
    • 2008
  • This study is to derive the fourth-order Geomorphologic Instantaneous Unit Hydrograph (GIUH), driven for only third-order basin, for the application of GIUH to various types of basin. The second, third, and fourth order GIUHs were compared for various topographical conditions. The results showed lower peak runoff and later peak time in GIUH with higher stream order. Initial state probability was estimated from a function of geomorphologic parameters such as area ratio and bifurcation ratio for the application of GIUH. However, initial state probabilities and early parts of the GIUHs have negative values for many basins due to the inherent errors in the parameters. Initial state probability was calculated by area ratio of direct drainage using ArcView GIS 3.2 model to solve the problem. GIUHs were estimated for three basins, Sanganmi, Byeongcheon, and Sangye, using the above suggested method, and the results showed that the method is free of the problem.

Value of Bone Scintigraphy and Single Photon Emission Computed Tomography (SPECT) in Lumbar Facet Disease and Prediction of Short-term Outcome of Ultrasound Guided Medial Branch Block with Bone SPECT

  • Koh, Won-Uk;Kim, Sung-Hoon;Hwang, Bo-Young;Choi, Woo-Jong;Song, Jun-Gul;Suh, Jeong-Hun;Leem, Jeong-Gill;Shin, Jin-Woo
    • The Korean Journal of Pain
    • /
    • v.24 no.2
    • /
    • pp.81-86
    • /
    • 2011
  • Background: Facet joint disease plays a major role in axial low-back pain. Few diagnostic tests and imaging methods for identifying this condition exist. Single photon emission computed tomography (SPECT) is reported that it has a high sensitivity and specificity in diagnosing facet disease. We prospectively evaluated the use of bone scintigraphy with SPECT for the identification of patients with low back pain who would benefit from medial branch block. Methods: SPECT was performed on 33 patients clinically suspected of facet joint disease. After SPECT, an ultrasound guided medial branch block was performed on all patients. On 28 SPECT-positive patients, medial branch block was performed based on the SPECT findings. On 5 negative patients, medial branch block was performed based on clinical findings. For one month, we evaluated the patients using the visual analogue scale (VAS) and Oswestry disability index. SigmaStat and paired t-tests were used to analyze patient data and compare results. Results: Of the 33 patients, the ones who showed more than 50% reduction in VAS score were assigned 'responders'. SPECT positive patients showed a better response to medial branch blocks than negative patients, but no changes in the Oswestry disability index were seen. Conclusions: SPECT is a sensitive tool for the identification of facet joint disease and predicting the response to medial branch block.

An Accuracy Estimation of AEP Based on Geographic Characteristics and Atmospheric Variations in Northern East Region of Jeju Island (제주 북동부 지역의 지형과 대기변수에 따른 AEP계산의 정확성에 대한 연구)

  • Ko, Jung-Woo;Lee, Byung-Gul
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.3
    • /
    • pp.295-303
    • /
    • 2012
  • Clarify wind energy productivity depends on three factors: the wind probability density function(PDF), the turbine's power curve, and the air density. The wind PDF gives the probability that a variable will take on the wind speed value. Wind shear refers to the change in wind speed with height above ground. The wind speed tends to increase with the height above ground. also, Wind PDF refers to the change with height above ground. Wind analysts typically use the Weibull distribution to characterize the breadth of the distribution of wind speeds. The Weibull distribution has the two-parameter: the scale factor c and the shape factor k. We can use a linear least squares algorithm(or Ln-least method) and moment method to fit a Weibull distribution to measured wind speed data which data was located same site and different height. In this study, find that the scale factor is related to the average wind speed than the shape factor. and also different types of terrain are characterized by different the scale factor slop with height above ground. The gross turbine power output (before accounting for losses) was caculated the power curve whose corresponding air density is closest to the air density. and air desity was choose two way. one is the pressure of the International Standard Atmosphere up to an elevation, the other is the measured air pressure and temperature to calculate the air density. and then each power output was compared.

Prioritizing of Civil-BIM DB Construction based on Geo-Spatial Information System (지형공간정보체계 기반의 토목-BIM DB구축 우선순위 선정)

  • Park, Dong Hyun;Kang, In Joon;Jang, Yong Gu;Lee, Byung Gul
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.1
    • /
    • pp.73-79
    • /
    • 2015
  • Recently, BIM proliferates at high speeds so that BIM planning is trying to be used in various kinds of engineering. However, when using different software during design phase and construction phase, the problem of mutual compatibility is coming out. Even the BIM technology has been used or the practical applicability has been made into result, it would be fair to say that BIM has limitations in the visual level. In this research, it is meaningless to obtain the BIM result as the primary purpose. As the usefulness of it is judged incomplete, we committed to master the trend and problems of terrain spatial information systems and BIM. Furthermore, the plan of building the BIM in the civil field, especially the civil-BIM based on the technology ofterrain spatial information has been presented. It can be judged through this research that the high-capacity DB of BIM occurred during the whole process may cause poor performance of the following stage the structure system which connects the terrain spatial information and civil-BIM. In order to manage the optimal full cycle, the spatial analysis technology of the stages after choosing the DB has been described.

THE EFFECT OF CONSISTENCY OF SEALER ON CANAL OBTURATION IN INJECTION-THERMOPLASTICIZED GUlTA-PERCHA METHOD (연화(軟化) Gutta-percha 충전법(充塡法)에서 Sealer의 조도(稠度)가 근관폐쇄(根管閉鎖)에 미치는 영향(影響))

  • Lee, Young-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.2
    • /
    • pp.38-48
    • /
    • 1989
  • The purpose of this study was to investigate the proper consistency of root canal sealer needed in obtaining an efficient canal obturation in injection-thermoplasticized low-temperature ($70^{\circ}C$) gutta-percha method. The sealer was made by incorporating zinc oxide powder into $0.5m{\ell}$ of eugenol and then the $0.5m{\ell}$ of mixture slurry was placed between two flat glass plates. The consistency was determined by measuring the degree of spread of the slurry at loading the 120gm of weight from the top plate. The sealer was prepared according to P/L ratio corresponding to the acquired consistency of 65.45mm, 46.80mm, 28.95mm and 22.60mm. The distal roots were obtained by cutting off from 125 extracted human lower molars and the root canals were prepared by using step-back method. The prepared canals were coated with the sealers on their walls and obturated by using the injection-thermoplasticized low-temperature ($70^{\circ}C$) gutta-percha method. All specimens were immersed in 2% methylene blue dye solution for 48 hours at $37^{\circ}C$. Calipers was used to measured the dye penetration into the root canals from apical constrictions. The results were as follows : The canals obturated without sealer showed significantly more leakage than the canals obturated with sealer. Within the consistency from 65.45mm to 22.60mm, the sealer of 65.45mm appeared significantly better than that of 28.95mm and 22.60mm in the canals obturated by injection-thermoplasticized gutta-percha method, and better than that of 46.80mm without statistical significance.

  • PDF

The Study on the Mapping of Wind Resource using Moving Filter Technique at Udo, Jeju Island (무빙필터 기법을 적용한 제주 우도지역의 풍력자원지도 작성에 대한 연구)

  • Moon, Seo Jeong;Ko, Jung Woo;Lee, Byung Gul
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.20 no.4
    • /
    • pp.29-36
    • /
    • 2012
  • In order to create a wind resource map, we need wind data, contour map and roughness map. Moving Filter technique was applied to Udo of Jeju Island to improve the accuracy and efficiency of creating roughness map based on the Land Cover Map of the Ministry of Environment. The Land Cover Map was simplified using moving filtering, and the roughness map was created with this Land Cover Map. The wind resource map was created using this roughness map. Finally, we verified the validity and application of moving filter technique for wind resource map. As a result, the wind map which was created using the roughness map with moving filtering showed bias values which were all negative. It means the wind map is underestimated to values of wind energy and RMSE values were also from 0.0237m/s to 0.0253m/s at 50m height. In other words, estimation of wind resource using image filtering provides reliable results at 80m height typically when the wind turbine is installed. Finally, we found that image filtering technique is very useful tool to make wind resource map.

Three-dimensional image analysis of the skull using variable CT scanning protocols-effect of slice thickness on measurement in the three-dimensional CT images (두개골의 3차원 영상 분석을 위한 전산화단층촬영 방법의 비교-상층 두께가 3차원 영상의 계측에 미치는 영향)

  • Jeong Ho-Gul;Kim Kee-Deog;Park Hyok;Kim Dong-Ook;Jeong Haijo;Kim Hee-Joung;Yoo Sun Koo;Kim Yong Oock;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.151-157
    • /
    • 2004
  • Purpose : To evaluate the quantitative accuracy of three-dimensional (3D) images by means of comparing distance measurements on the 3D images with direct measurements of dry human skull according to slice thickness and scanning modes. Materials and Mathods : An observer directly measured the distance of 21 line items between 12 orthodontic landmarks on the skull surface using a digital vernier caliper and each was repeated five times. The dry human skull was scanned with a Helical CT with various slice thickness (3, 5, 7 mm) and acquisition modes (Conventional and Helical). The same observer measured corresponding distance of the same items on reconstructed 3D images with the internal program of V-works 4.0/sup TM/(Cybermed Inc., Seoul, Korea). The quantitative accuracy of distance measurements were statistically evaluated with Wilcoxons' two-sample test. Results: 11 line items in Conventional 3 mm, 8 in Helical 3mm, 11 in Conventional 5mm, 10 in Helical 5mm, 5 in Conventional 7mm and 9 in Helical 7mm showed no statistically significant difference. Average difference between direct measurements and measurements on 3D CT images was within 2mm in 19 line items of Conventional 3mm, 20 of Helical 3mm, 15 of Conventional 5mm, 18 of Helical 5mm, II of Conventional 7mm and 16 of Helical 7mm. Conclusion: Considering image quality and patient's exposure time, scanning protocol of Helical 5mm is recommended for 3D image analysis of the skull in CT.

  • PDF

Clinical usefulness of facial soft tissues thickness measurement using 3D computed tomographic images (3차원 전산화단층촬영 영상을 이용한 안면 연조직 두께 계측의 임상적 유용성)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Choi Seong-Ho;Kim Chong-Kwan;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.2
    • /
    • pp.89-94
    • /
    • 2006
  • Purpose : To evaluate clinical usefulness of facial soft tissue thickness measurement using 3D computed tomographic images. Materials and Methods : One cadaver that had sound facial soft tissues was chosen for the study. The cadaver was scanned with a Helical CT under following scanning protocols about slice thickness and table speed; 3 mm and 3 mm/sec, 5 mm and 5 mm/sec, 7 mm and 7 mm/sec. The acquired data were reconstructed 1.5, 2.5, 3.5 mm reconstruction interval respectively and the images were transferred to a personal computer. Using a program developed to measure facial soft tissue thickness in 3D image, the facial soft tissue thickness was measured. After the ten-time repeation of the measurement for ten times, repeated measure analysis of variance (ANOVA) was adopted to compare and analyze the measurements using the three scanning protocols. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant intraobserver differences in the measurements of the facial soft tissue thickness using the three scanning protocols (p>0.05). There were no statistically significant differences between measurements in the 3 mm slice thickness and those in the 5 mm, 7 mm slice thickness (p>0.05). There were statistical differences in the 14 of the total 30 measured points in the 5 mm slice thickness and 22 in the 7 mm slice thickness. Conclusion : The facial soft tissue thickness measurement using 3D images of 7 mm slice thickness is acceptable clinically, but those of 5 mm slice thickness is recommended for the more accurate measurement.

  • PDF