• Title/Summary/Keyword: GT-POWER

Search Result 92, Processing Time 0.023 seconds

Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.99-105
    • /
    • 2016
  • The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electro-technical Commission standard (IEC 62220-1). Various radiation therapy (RT) devices such as TrueBeam$^{TM}$(Varian), BEAMVIEW$^{PLUS}$(Siemens), iViewGT(Elekta) and Clinac$^R$ iX (Varian) were used. In order to measure the region of interest (ROI) of the NPS, we used the following four factors: the overlapping impact, the non-overlapping impact, the flatness and penumbra. As for NPS results, iViewGT(Elekta) had the higher amplitude of noise, compared to BEAMVIEW$^{PLUS}$ (Siemens), TrueBeam$^{TM}$(Varian) flattening filter, Clinac$^{R}$iXaS1000(Varian) and TrueBeam$^{TM}$(Varian) flattening filter free. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS methodologies control in MVI.

A Real-time Calculation Method on Performance Impact of Controllable Operation Parameters for Combined Cycle rower Plant (복합화력 제어가능 운전 파라미터의 실시간 영향산출 기법)

  • Joo Yong-Jin;Park Jong-Ho
    • Journal of Energy Engineering
    • /
    • v.15 no.1 s.45
    • /
    • pp.67-73
    • /
    • 2006
  • A calculation method on performance impact of the controllable operations parameter such as GT inlet filter ${\Delta}P$, compressor efficiency, and condenser pressure was devised to achieve best performance of combined cycle power plant with the on-line performance monitoring system. This method calculates the performance impact on the deviation between 'Expected' values and 'Actual' values. Controllable parameter targets are determined based on achievable performance given existing equipments and control conditions.

Perfomance Simulation of a EFI Small Engine (전자분사식 소형엔진의 성능 해석)

  • Yeom, Kyoung-Min;Park, Sung-Young
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.1007-1009
    • /
    • 2010
  • 실험을 통하여 엔진의 성능을 파악하고자 한다면 적지 않은 시간동안 많은 비용과 노력이 필요하다. 최근 연구에서는 이러한 단점을 해결하기 위해 CFD를 이용 선행해석을 통해 미리 그 엔진의 성능을 예측하여 실험에 들이는 시간과 비용을 줄여가고 있다. 본 연구는 실험을 통하여 소형엔진의 성능을 알아보기 이전에 선행해석을 통해 소형엔진의 성능을 예측하고자 한다. 소형엔진의 선행 해석을 위해 전자제어 연료분사 방식의 400cc급 소형엔진을 모델링하고 1D 해석프로그램인 GT-Power를 통하여 엔진의 Toque, Power 및 배기가스를 예측하였다.

  • PDF

Scale Efficiency and Fishing Capacity Analysis for Large Pair-Trawl Vessels in Korean Waters (한국 근해 쌍끌이 대형기선저인망어선의 규모별 효율성과 어회능력 활용도 평가)

  • Lee, Dong-Woo;Lee, Jae-Bong;Jung, Suk-Geun;Kim, Yeong-Hye
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.41 no.6
    • /
    • pp.485-492
    • /
    • 2008
  • To propose proper vessel characteristics for sustainable fisheries in Korean waters, we analyzed the fishing capacity, scale efficiency and utilization of large pair-trawl vessels based on the database of catch, effort and vessel characteristics (gross tonnage and engine power) in 1990 by applying data envelopment analysis (DEA). The input factors were gross tonnage, horse power and days operated; whereas the output factor was expected catch by vessel characteristics. The optimal vessel types, selected based on the input-oriented technical efficiency and gross tonnages, was 100 GT with engine power <600 HP. The output-oriented unbiased estimate of capacity utilization (CD) decreased with increasing vessel tonnage. For the same tonnage vessels, the CD decreased with increasing engine power.

Analysis of Performance Characteristics of Gas Turbine-Pressurized SOFC Hybrid Systems Considering Limiting Design Factors (제한요소를 고려한 가스터빈-가압형 SOFC 하이브리드 시스템의 성능특성 해석)

  • Yang Won Jun;Kim Tong Seop;Kim Jae Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1013-1020
    • /
    • 2004
  • The hybrid system of gas turbine and fuel cell is expected to produce electricity more efficiently than conventional methods, especially in small power applications such as distributed generation. The solid oxide fuel cell (SOFC) is currently the most promising fuel cell for the hybrid system. To realize the conceptual advantages resulting from the hybridization of gas turbine and fuel cell, optimized construction of the whole system must be the most important. In this study, parametric design analyses for pressurized GT/SOFC systems have been peformed considering probable practical limiting design factors such as turbine inlet temperature, fuel cell operating temperature, temperature rise in the fuel cell and soon. Analyzed systems include various configurations depending on fuel reforming type and fuel supply method.

A techno-economic analysis of partial repowering of a 210 MW coal fired power plant

  • Samanta, Samiran;Ghosh, Sudip
    • Advances in Energy Research
    • /
    • v.3 no.3
    • /
    • pp.167-179
    • /
    • 2015
  • This paper presents a techno-economic analysis of a partial repowering scheme for an existing 210 MW coal fired power plant by integrating a gas turbine and by employing waste heat recovery. In this repowering scheme, one of the four operating coal mills is taken out and a new natural gas fired gas turbine (GT) block is considered to be integrated, whose exhaust is fed to the furnace of the existing boiler. Feedwater heating is proposed through the utilization of waste heat of the boiler exhaust gas. From the thermodynamic analysis it is seen that the proposed repowering scheme helps to increase the plant capacity by about 28% and the overall efficiency by 27%. It also results in 21% reduction in the plant heat rate and 29% reduction in the specific $CO_2$ emissions. The economic analysis reveals that the partial repowering scheme is cost effective resulting in a reduction of the unit cost of electricity (UCOE) by 8.4%. The economic analysis further shows that the UCOE of the repowered plant is lower than that of a new green-field power plant of similar capacity.

A study on the Implementation Extended Concept of GTS in IEEE 802.15.4 (IEEE 802.15.4에서 GTS의 확장개념에 관한 연구)

  • Jeon, Dong-Keun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.3
    • /
    • pp.319-325
    • /
    • 2015
  • Remarkable advances in wireless communication technology have enabled communications among people who are far away from each other. In recent, the needs of local area voice communication using a wireless system based on low-cost and simple hardware are rapidly rising. However, since these applications require that the multi-users communicate on the same wireless channel in a small area, the existing voice technologies are not suitable for directly applying to these applications. Therefore, in this paper I propose a novel idea enabling multi-user voice communication. In particular, as a short range wireless solution, I employ the IEEE 802.15.4 based on low power and low cost. However, since originally the standard is not developed for voice communication, we extend the original scheme to be suitable for the voice communication by utilizing the extended concept of GTS. The capacity and validity of the proposed scheme are evaluated through quantitative analysis in various voice compression rates.

Performance Simulation of Motorcycle Engine Exhaust Heat Recovery System using Thermoelectric Element (열전소자를 이용한 모터사이클용 엔진 배기 폐열 회수 시스템 성능 해석)

  • Lee, Moo-Yeon;Kim, Kihyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.695-701
    • /
    • 2018
  • Research into exhaust heat recovery has been actively carried out to improve the thermal efficiency of internal combustion engines. In this study, the performance of thermoelectric generation from exhaust heat recovery for motorcycle engines was analyzed by 1-D thermo-fluid simulation. GT-SUITE, which was developed by Gamma Tech., was used for the simulation of the internal combustion engine and thermoelectric generation system. The basic performance of the engine was analyzed in the range of engine speed of 1000~7000 rpm and engine load of 0~100%. The ratio of exhaust heat energy to fuel chemical energy was found to be about 40~60%. A combined simulation of the engine model and thermoelectric generation model was carried out to analyze the voltage, current and power generated by the thermoelectric material. The generation characteristics of the thermoelectric material was dominantly affected by the exhaust gas temperature. The maximum generated power of the current thermoelectric generation system was found to be about 2.2% of the total exhaust heat energy. The design optimization of the thermoelectric generation system will be carried out to maximize its power generation and economic feasibility.

Muffler Design Using Transmission Loss Prediction Considering Heat and Flow (열과 유동을 고려한 음장해석을 통한 머플러의 설계)

  • Kim, Hyunsu;Kang, Sang-Kyu;Lim, Yun-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.8
    • /
    • pp.600-605
    • /
    • 2014
  • Two mufflers for a large-size sedan are suggested aiming (1) sporty-sound and (2) quiet-sound as well as both satisfying low back-pressure and low manufacturing cost. Transmission loss prediction considering heat and flow may increase the accuracy and reduce the development cost in muffler design; thus, GT-power prediction considering heat, flow, and acoustics is utilized. By understanding the fundamentals of flow-acoustic theory in small orifice(hole), an effective muffler design concept is proposed. Vehicle tests show the consistence with predictions for sound; also a back-pressure test bench confirms the advantage in pressure drop for both suggested mufflers. Those suggested mufflers also have advantages in manufacturing cost due to simplicity of the design.

Analysis of Cylinder-to-Cylinder EGR Distribution of Gasoline Engine Intake Manifold (가솔린엔진 흡기매니폴드의 기통별 EGR 분배특성 연구)

  • Yeom, Kyoung-Min;Lee, Sang-In;Park, Sung-Young
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.534-537
    • /
    • 2009
  • 최근 자동차 배기가스 규제가 더욱 강화됨에 따라 완전 연소를 통한 배기가스 저감에 관하여 많은 연구가 진행되고 있다. 특히, 고온 연소시 문제가 되는 질소 산화물의 저감을 위해 많은 노력을 기울이고 있다. 질소 산화물을 저감하는데 효과적인 EGR 기술의 도입이 보편화되고 있지만, 각 실린더별 EGR 분배 특성에 따라 엔진의 성능이 달라지는 역효과가 발생한다. 시제품을 동한 EGR 분배특성 파악은 비용과 시간 측면에서 상당한 난제가 산재해있다. 본 연구에서는 이러한 실험시간과 비용 절감을 위하여 1D 성능해석 프로그램인 GT-Power를 적용 EGR의 분배특성을 예측하였다.

  • PDF