• 제목/요약/키워드: GMI

검색결과 52건 처리시간 0.029초

백서의 피하조직에 Gelatin Matrix Implant (Fibrel®) 매식시 조직변화에 관한 연구 (TISSUE CHANGE AFTER EMBEDDING GELATIN MATRIX IMPLANT(FFIBREL®) IN SUBCUTANEOUS TISSUE OF RATS;HISTOLOGIC, IMMUNOHISTOCHEMICAL AND SCANNING ELECTRON MICROSCOPIC STUDY)

  • 김홍진;이종헌;김경욱
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제20권4호
    • /
    • pp.341-354
    • /
    • 1998
  • GMI (Fibrel${(R)}$) is one of the dermal filling substances which have been successfully used for the treatment of depressed cutaneous scar and wrinkles. It's major components are; Gelatin powder, which provides a framework for the clot to form and remains stable under the scar, and ${\varepsilon}$-aminocaproic acid, which inhibits the production of fibrinolysin, and Plasma, which provides the necessary ingredients for collagen synthesis. GMI has advantages of low immunogenicity and increased longevity. It has been known to induce fibroblast activity and promote new collagen synthesis. We used 34 Sprague-Dawley rats which were bred under the same condition and duration. 18 of experimental animals were undergone cardiac puncture, and their blood were collected, centrifugated, and stored in freezer. Out of 16 animals, control group were injected with 2ml plasma into the subcutaneous tissue of Lt. scapular, while experimental group were implanted of 2 ml GMI into the Rt. same area. Experimental animals were sacrificed at the 3rd day, 5th day, 1st week and 2nd week respectively after implantation of GMI. To observe the histopathologic change of GMI and surrounding tissue reaction of GMI, we had examined with H&E staining, immunohistochemical staining with vimentin, ${\alpha}$-SMA, S-100 under LM and SEM. The obtained results were as follows ; 1. In LM study, the inflammatory cell infiltrations and granulation tissue formation were observed, and muscle tissues were well attached with adipose tissues in the control group. In the experimental group, inflammatory cell infiltrations had been observed by the 2nd week and irregular adipiose tissues and well differentiated mesenchymal tissues were examined. 2. In immunohistochemical study, the experimental group of ${\alpha}$-SMA study, there were a prominent positive response on endothelial development of granulation tissues and mesenchymal tissues compare with the control group. In vimentin study, positive response on mescenchymal fibroblast continued to 2nd week, but negative in the control group. In S-100 study, both groups were positively responded on irregular adipose tissues. 3. In SEM study, collagen fibers were embedded by the plasma by the 5th day in the control group, and in the 3rd day experiment GMI were resorved but communited with collagen fiber till the 1st week. Collagen fibers were infilt-rated into GMI at the 2nd week and the infilltrated GMI were conglomerated with the mature adipose cells and the collagen fibers. From the above results, GMI implantation in the subcutaneous tissue of Sprague-Dawley rat, the mild infiltration of inflammatory cells were showed till 2nd week and the granulation tissues were observed. GMI were nearly resorbed till 2nd week, but well attached with adipose tissue and collagen fibers. The endothelium and fibroblasts were actively proliferated. Adipose tissues and mesenchymal tissue cells were observed. As already expressed, GMI showed resorptive change in course of time without any early immune reaction, and seemed to induce fibroblast activity and promote new collagen synthesis.

  • PDF

GMI Magnetic Field Sensor Based on a Time-coded Principle

  • Cao, Xuan-Huu;Son, De-Rac
    • Journal of Magnetics
    • /
    • 제15권4호
    • /
    • pp.221-224
    • /
    • 2010
  • A laboratory sensor model was designed, constructed, and tested based on a newly proposed working principle of magnetic field detection. The principle of sensing employed a time-coded method in correlation with exploiting the advantageous features of the GMI effect. The sensor demonstrated a sensitivity of $10\;{\mu}s/{\mu}T$ in the field range of ${\pm}100\;{\mu}T$. The sensing element in the form of an amorphous thin wire, $100\;{\mu}m$ in diameter ${\times}50\;mm$ long, was fit into a small field modulation coil of 60 mm length. At a magnetic field modulation in the range of hundreds of Hz, the change in time interval of two adjacent GMI voltage peaks was linearly related to the external magnetic field to be measured. This mechanism improved the sensor linearity of the GMI sensor to better than 0.2% in the measuring range of ${\pm}100\;{\mu}T$.

Dependence of GMI Profile on Size of Co-based Amorphous Ribbon

  • Jin, L.;Yoon, S.S.;Kollu, P.;Kim, C.G.;Suhr, D.S.;Kim, C.O.
    • Journal of Magnetics
    • /
    • 제12권1호
    • /
    • pp.31-34
    • /
    • 2007
  • The Co-based ribbons with different length were annealed in different magnetic field and GMI profiles were investigated in order to clarify the influence of ribbon size on GMI effect. The GMI ratio decreased with the decreasing in length and also decreased with increasing annealing field. While, the slope of GMI profiles inclined and the field range showing linearity was broadened. It shows prospect to low field sensor, especially for a navigation sensor.

Effectiveness of graded motor imagery in subjects with frozen shoulder: a pilot randomized controlled trial

  • Gurudut, Peeyoosha;Godse, Apurva Nitin
    • The Korean Journal of Pain
    • /
    • 제35권2호
    • /
    • pp.152-159
    • /
    • 2022
  • Background: Subjects with frozen shoulder (FS) might not be comfortable with vigorous physical therapy. Clinical trials assessing the effect of graded motor imagery (GMI) in FS are lacking. The aim of this study was to determine the effect of GMI as an adjunct to conventional physiotherapy in individuals with painful FS. Methods: Twenty subjects aged 40-65 years having stage I and II of FS were randomly divided into two study groups. The conventional physiotherapy group (n = 10) received electrotherapy and exercises while the GMI group (n = 10) received GMI along with the conventional physiotherapy thrice a week for 3 weeks. Pre- (Session 1) and post- (Session 9) intervention analysis for flexion, abduction, and external rotation range of motion (ROM) using a universal goniometer, fear of movement using the fear avoidance belief questionnaire (FABQ), pain with the visual analogue scale, and functional disability using the shoulder pain and disability index (SPADI) was done by a blinded assessor. Results: Statistically significant difference was seen within both the groups for all the outcomes. In terms of increasing abduction ROM as well as reducing fear of movement, pain, and functional disability, the GMI group was significantly better than control group. However, both groups were equally effective for improving flexion and external rotation ROM. Conclusions: Addition of GMI to the conventional physiotherapy proved to be superior to conventional physiotherapy alone in terms of reducing pain, kinesiophobia, and improving shoulder function for stage I and II of FS.

한반도 주변해 GMI 마이크로파 해수면온도 검증과 환경적 요인 (GMI Microwave Sea Surface Temperature Validation and Environmental Factors in the Seas around Korean Peninsula)

  • 김희영;박경애;곽병대;주희태;이준수
    • 한국지구과학회지
    • /
    • 제43권5호
    • /
    • pp.604-617
    • /
    • 2022
  • 해수면온도는 해양-대기의 현상을 이해하고 기후변화를 예측하기 위해 사용되는 중요한 변수이다. 마이크로파 영역의 인공위성 원격탐사는 구름과 강수와 같은 기상현상 위성 관측 측기의 경로에 존재하더라도 해수면온도 획득을 가능하게 한다. 따라서 마이크로파 해수면온도의 높은 활용도를 고려하면 위성 해수면온도를 정확도를 지속적으로 검증하고 오차 특성을 분석할 필요가 있다. 본 연구에서는 2014년 3월부터 2021년 12월까지 약 8년 동안 Global Precipitation Measurement (GPM)/GPM Microwave Imager (GMI) 마이크로파 해수면온도의 정확도를 표층 뜰개 부이 수온 자료를 사용하여 검증하였다. GMI 해수면온도는 실측 해수면온도에 비해 0.09 K의 편차와 0.97 K의 평균 제곱근 오차를 보였고, 이는 기존 연구 결과에 비해 다소 높게 나타났다. 이외에도 GMI 해수면 온도의 오차 특성은 위도, 연안과의 거리, 해상풍 및 수증기량과 같은 환경적 요인과 관련성이 있다. 오차는 육지에서 300 km 이내의 거리에서 해안 지역에 가까운 지역과 고위도 지역에서 증가하는 경향이 있다. 또한 낮에는 약한 풍속(<6 m s-1), 밤에는 강한 풍속(>10 m s-1) 범위에서 상대적으로 높은 오차가 나타났다. 대기 수증기는 30 mm 미만의 매우 낮은 범위 또는 60 mm보다 큰 매우 높은 범위에서 높은 해수면온도 차이에 기여했다. 이러한 오차들은 저수온에서 GMI 자료의 정확도가 떨어지는 기존 연구와 일치하며, 연안으로부터의 거리, 풍속, 수증기량에 의한 오차의 경우 육지와 해양의 방사율 차이 및 바람에 의한 해수면 거칠기 변화, 수증기의 마이크로파 대기 흡수에서 기인하는 것으로 추정된다. 이는 한반도 주변해에서 마이크로파 위성 계산 SST를 보다 광범위하게 활용하기 위해서는 GMI 해수면온도 오차의 특성에 대한 이해가 필요함을 시사한다.

GMI Magnetic Field Sensor based on Time-coded Principle

  • Cao, Xuan-Huu;Son, De-Rac
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2009년도 정기총회 및 동계학술연구발표회
    • /
    • pp.217-219
    • /
    • 2009
  • A GMI magnetic field sensor working based on time-coded principle has been investigated and designed. The laboratory model has been constructed and tested carefully, demonstrating the sensitivity of $3\;{\mu}s/{\mu}T$ in the field range of ${\pm}100\;{\mu}T$. An amorphous thin wire, $100\;{\mu}m$ in diameter ${\times}50\;mm$ in length, was chosen to be sensing element which was fit into a small field modulation coil of 60 mm in length. The sensor is working based on a time-coded principle that, with the magnetic field modulation was chosen in range of hundreds of Hz, the change in time interval of two adjacent GMI peaks relating to external DC magnetic field is proportional to the intensity of the external field to be measured. This mechanism has made a great improvement to the linearity of the sensor.

  • PDF

교류자기저항효과를 이용한 비정질 리본 전류센서 (Current sensor application of giant magnetoimpedance in amorphous materials)

  • 임영우;김철기;김종오;김기덕;박영태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 초전도 자성체
    • /
    • pp.11-13
    • /
    • 2002
  • The performance of DC current sensor based on giant magnetoimpedance (GMI) effect in amorphous ribbon has been tested. The ribbon after field annealing shows the maximum GMI ratio of 30 % at 100 kHz measuring frequency. In the sensor element of sample wound the circular form, GMI ratio and sensitivity are decreased due to internal stress. The sensor voltage output increases with applied DC current up to 1 A with a good linearity, of which direction can be known due to asymmetric characteristics.

  • PDF

Time-Coded GMI Magnetic Field Sensor

  • Cao, Xuan-Huu;Son, Derac
    • Journal of Magnetics
    • /
    • 제14권3호
    • /
    • pp.129-131
    • /
    • 2009
  • A time-coded giant magnetoimpedance (GMI) magnetic field sensor was investigated and designed. The successfully constructed and tested laboratory model demonstrated a sensitivity of 5 ${\mu}s/{\mu}T$ in the field range of $\pm200{\mu}T$. The sensing element in the form of an amorphous thin wire, 100 mm in diameter $\times50$ mm long, was fit into a small field modulation coil of 60 mm length. At a magnetic field modulation in the range of hundreds of Hz, the change in time interval of two adjacent GMI voltage peaks was linearly related to the external magnetic field to be measured. This mechanism improved the sensor linearity to better than 0.3% in the measuring range of $\pm200{\mu}T$.

Surface Crystalline Modification for Asymmetric Giant Mngnetoimpedance Profile in Annealed Co-based Amorphous Ribbons

  • Rheem, Y.W;Kim, C.G;Kim, C.O;Choi, Y
    • Journal of Magnetics
    • /
    • 제6권3호
    • /
    • pp.86-89
    • /
    • 2001
  • Microstructure modifications are investigated for annealed Co-based amorphous ribbon in vacuum and open air. X-ray diffraction (XRD) spectra for annealed sample in vacuum indicate atomic arrangements with initial nucleation of hcp-Co crystallite at 38$0^{\circ}C$ annealing temperature. However, the XRD spectra in samples with long annealing times of $t_a\geq300$ min demonstrate sharp and good developed surface crystalline hcp-, fcc- Co and $Co_2$Si phases. The giant magnetoimpedance (GMI) profile at 0.1 MHz displaying one-peak behavior in vacuum annealed samples at T = 38$0^{\circ}C$ irrespective of annealing time $t_a$ from 20 to 480 mim. For the annealed samples in an open air, the GMI profile shows two-peaks for $t_a$ = 20 min annealed sample. However, one of peaks disappears and an asymmetric GMI profile exhibits a drastic step-like change near zero field for $t_a\geq300$min. Such asymmetric GMI characteristics is related to the surface microstructures of fcc-Co, hop-Co and $Co_2$Si crystalline phases.

  • PDF