• Title/Summary/Keyword: GD1a

Search Result 505, Processing Time 0.025 seconds

Sintering and Grain Growth of Rare Earth-Doped Ceria Particles

  • Sameshima, Soichiro;Higashi, Kenji;Hirata, Yoshihiro
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 2000.06a
    • /
    • pp.65-86
    • /
    • 2000
  • Rare earth-doped ceria powders with a composition of Ce0.8R0.2O1.9(R=Yb, Y, Gd, Sm, Nd and La) were prepared by heating the oxalate coprecipitate. The green compacts began to shrink at 600$^{\circ}$-700$^{\circ}C$. The relative density after the sintering at 1200$^{\circ}$ and 1400$^{\circ}C$ became higher for the higher green density. The samples were densified above 98% relative density by the sintering ant 1600$^{\circ}C$ for 4 h and the grain sizes (4.7-7.6$\mu\textrm{m}$) showed a tendency to become larger with increasing ionic radius of doped-rare earth element. In the intial stag of sintering at 700$^{\circ}$-800$^{\circ}C$, the dominant mass transport process changed from lattice diffusion to grain boundary diffusion to grain boundary diffusion with heating time. The porosity during the intermediated and final stage of the sintering at 1200$^{\circ}$ and 1400$^{\circ}C$ decreased by the mass transport through lattice diffusion with grain growth.

  • PDF

Characterization of PSCF3737 for intermediate temperature solid oxide fuel cell (IT-SOFC) (중.저온형 고체 산화물 연료전지의 공기극으로 사용되는 PSCF3737 물질의 특성에 관한 연구)

  • Park, Kwang-Jin;Bae, Joong-Myeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.61-64
    • /
    • 2008
  • $Pr_{0.3}Sr_{0.7}Co_{0.3}Fe_{0.7}O_{3-\delta}$ (PSCF3737) was prepared and characterized as a cathode material for intermediate temperature-operating solid oxide fuel cell (IT-SOFC). X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), extended X-ray absorption fine structure (EXAFS), and electrical property measurement were carried out to study cathode performance of the material. XPS and EXAFS results proved that oxygen vacancy concentration was decreased and lattice constants of the perovskite structure material were increased by doping Fe up to 70 mol% at B-site of the crystal structure, which also extended the distance between oxygen and neighbor atoms. Thermal expansion coefficient (TEC) of PSCF3737 is smaller than that of $Pr_{0.3}Sr_{0.7}CoO_{3-\delta}$(PSC37) due to lower oxygen vacancy concentration. PSCF3737 showed better cathode performance than PSC37. It might be due good adhesion by a smaller difference of TEC between $Gd_{0.1}Ce_{0.9}O_2$ (CGO91) and electrode. Composite material PSCF3737-CGO91 showed better compatibility of TEC than PSCF3737. However, PSCF3737-CGO91 did not represent higher electrochemical property than PSCF3737 due to decreased reaction sites by CGO91.

  • PDF

Spectral, Electrochemical, Fluorescence, Kinetic and Anti-microbial Studies of Acyclic Schiff-base Gadolinium(III) Complexes

  • Vijayaraj, A.;Prabu, R.;Suresh, R.;Kumari, R. Sangeetha;Kaviyarasan, V.;Narayanan, V.
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3581-3588
    • /
    • 2012
  • A new series of acyclic mononuclear gadolinium(III) complexes have been prepared by Schiff-base condensation derived from 5-methylsalicylaldehyde, diethylenetriamine, tris(2-aminoethyl) amine, triethylenetetramine, N,N-bis(3-aminopropyl)ethylene diamine, N,N-bis(aminopropyl) piperazine, and gadolinium nitrate. All the complexes were characterized by elemental and spectral analyses. Electronic spectra of the complexes show azomethine (CH=N) within the range of 410-420 nm. The fluorescence efficiency of Gd(III) ion in the cavity was completely quenched by the higher chain length ligands. Electrochemical studies of the complexes show irreversible one electron reduction process around -2.15 to -1.60 V The reduction potential of gadolinium(III) complexes shifts towards anodic directions respectively upon increasing the chain length. The catalytic activity of the gadolinium(III) complexes on the hydrolysis of 4-nitrophenylphosphate was determined. All gadolinium(III) complexes were screened for antibacterial activity.

A Spectrophotometric Study on Color Differences between Various Light-Cured Composite Resins and Shade Guides (광중합형 복합레진과 shade guide의 색차에 관한 연구)

  • Lim, Kyung-Min;Lee, Min-Ho;Song, Kwang-Yeob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.13-22
    • /
    • 2009
  • The composite resin, due to its esthetic quality, is considered the material of choice for restoration of anterior teeth. To get a satisfactory result in the composite resin restorations, it is necessary to choose right shade. At present, most of the commercial composite resins are based on the Vita Lumin shade guides or shade guides that are provided by their company, but color differences among them might be expected even using the same shade in various materials. This study is to measure color differences between various light-cured composite resins and shade guides and to provide the clinicians with information which may aid in improved color match of esthetic restoration. Four kinds of light-cured composite resins (Gradia Direct (GD), Z250 (Z250), Clearfil AP-X (AP-X), Esthet X (E X)) and shade guides with A2 and A3 shade were used. Three specimens of each material and one specimen of each shade guide were made. Each composite resin was filled into the Teflon mold (1.35 mm depth, 8 mm diameter), followed by compression, polymerization and polishing with wet sandpaper. Shade guides were grinded with polishing stones and rubber points to a thickness of approximately 1.35 mm. Color characteristics were performed with a spectrophotometer(color i5, GretagMacbeth, USA). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$, $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E^*ab$) between composite resins and shade guides. CIE standard D65 was used as the light source. The results were as follows : 1. Among the $L^*$, $a^*$, $b^*$ values of most of 4 kinds of composite resin specimens which are produced by same shade, there were significant differences(p<0.05). 2. Among all 4 kinds of composite resin specimens which are produced by same shade, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 3. Between most of composite resin specimens investigated and their corresponding shade guides, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 4. In the clinical environment, it is recommended that custom shade guides be made from resin material itself for better color matching. Shade guides supplied by manufacturers or Vita Lumin shade guide may not provide clinicians a accurate standard in matching color of composite resins, and there are perceptible color differences in most of products. Therefore, it is recommended that custom shade guides be made from resin material itself and used for better color matching.

Magnetization of the stack of HTS tapes

  • Osipov, M.A.;Abin, D.A.;Pokrovskiy, S.V.;Mineev, N.A.;Rudnev, I.A.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.1
    • /
    • pp.21-24
    • /
    • 2015
  • New results of dependence of magnetic field, trapped by a stack of HTS tapes, on amount of tapes in a stack are reported. Commercial GdBCO tape 12 mm width and without Cu layer was used for the research. Tape was divided in square pieces $12{\times}12mm^2$ from which stacks were formed. Filling factor of the tape was about 1.4%. Measurements were carried out for stacks with height from 5 to 250 pieces and at wide temperature range from liquid helium to liquid nitrogen. Both FC (field cooling) and ZFC (zero field cooling) cooling methods were used in the research. These two methods show matching results with good accuracy. As a result dependences of trapped magnetic flux on amount of tapes for different temperatures were received. Research shows, that with increasing height of the stack trapped magnetic field value reach saturation at about 60 tapes in a stack for low temperatures. From 60 to 100 tapes increase of magnet flux is only 5%. Thus increase amount of tapes in a stack is not profitable. Also investigation of trapped magnet field relaxation was carried out. Relaxation speed decreases with increasing amount of elements. It means that the higher the stack is, the longer trapped flux will be held in cause of the same temperature.

Development of Macrocyclic Ligands for Stable Radiometal Complexes (안정한 방사금속 착물을 위한 거대고리 리간드 개발)

  • Yoo, Jeong-Soo;Lee, Jae-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.215-223
    • /
    • 2005
  • Current interest in the regioselective N-functionalization of tetraazacycloalkanes (cyclen and cyclam) stems mainly from their complexes with radioactive metals for applications in diagnostic ($^{64}Cu,\;^{111}In,\;^{67}Ga$) and therapeutic ($^{90}Y$) medicine, and with paramagnetic ions for magnetic resonance imaging ($Gd^{+3}$). Selective methods for the N-substitution of cyclen and cyclam is a crucial step in most syntheses of cyclen and cyclam-based radiometal complexes and bifunctional chelating agents. In addition, mixing different pendent groups to give hetero-substituted cyclen derivatives would be advantageous in many applications for fine-tuning the compound's physical properties. So far, numerous approaches for the regioselective N-substitution of tetraazacycloalkanes and more specifically cyclen and cyclam are reported. Unfortunately, none of them are general and every strategy has its own strong points and drawbacks. Herein, we categorize numerous regioselective N-alkylation methods into three strategies, such as 1) direct substitution of the macrocycle, 2) introductiou of the functional groups prior to cyclization, and 3) protection/iunclionallrationideproteclion. Our discussion is also split into the methods of mono- and tri-functionalization and di-functionalizataion based on number of substituents. At the end, we describe new trials for the new macrocycles which iorm more stable metal complexes with various radiometals, and briefly mention the commercially available tetraazacycloalkanes which are used for the biconjugation of biomolecules.

Behavior of Rare Earth Elements in Synthetic Fluorapatites Revealed by Rietveld Structure Refinement Data (리트벨트법에 의한 합성인회석 내의 희토류 원소의 거동에 관한 연구)

  • 문용희;최진범;이병임
    • Journal of the Mineralogical Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.221-230
    • /
    • 2000
  • 이성분 희토류 원소로 치환된 4종류의 합성불화인회석(synthetic fluorapatite) (Ap49: La+Gd, Ap50:Ce+Dy, Ap51: Pr+Er, Ap54: Eu+Lu; $Ca{10-x-2y}$ $Na_{y}$ $REE_{x+y}$($P_{1-x}$ //$Si_{x}$ $_{4}$)$_{6}$ $F_{2}$, x=0.13~0.12, y=0.26~0.42)을 대상으로 X-선 회절분석을 통해 얻어진 자료를 이용하여 리트벨트 구조분석을 실시하고 치환된 희토류원소의 거동을 단결정법으로 구해진 결과와 비교.분석하였다. 리트벨트 구조분석결과 합성불화인회석은 공간군 $P6_3$/m, 단위포는 평균하여 a=9.3906(1) $\AA$, c=6.8924(1) $\AA$, V=527.36 $\AA^3$의 값을 갖는다. 구조의 정밀도를 나타내는 R 지수를 보면 $R_{B}$ / 값은 17.29~18.80이고 S(GofF)값은 1.44~1.68로 계산되었다. 불화인회석은 9개의 산소를 배위하는 Ca1자리와 6개의 산소와 하나의 불소가 배위하는 Ca2자리가 있으며 Ca1-O의 평균거리는 2.563 $\AA$이고 Ca2-O의 평균거리는 $2.460 \AA$으로 Ca1자리가 Ca2자리보다 다소 크다. 구조자리 치환식에서는 $Ca^{2+}$ / 자리를 치환하는 $REE^{3+ }$ 로 인하여 전하균형을 맞춰주기 위해서 인과규소가 함께 참여하였다. ($REE^{3}$+Si$^{ 4+}$ $2Ca^{2+}$ : Ca1) 계산된 희토류원소의 자리점유율(REE-Ca2/REE-Cal)은 원자번호가 증가함에 따라 일정하게 감소하는 경향을 보여주며 이는 희토류원소의 거동이 LREE는 크기가 상대적으로 작은 Ca2 자리에 우선 치환되고 HREE는 크기가 큰 Ca1자리에 우선 치환되는 경향을 지시한다.

  • PDF

Surface Hardening and Wear Properties of AISI 410 Martensitic Stainless Steel by High & Low Temperature Gaseous Nitriding (고온 가스 질화와 저온 가스 질화 방법에 따른 AISI 410 마르텐사이트 스테인레스강의 경화층 및 마모 특성)

  • Son, Seok-Won;Lee, Won-Beom
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.4
    • /
    • pp.249-255
    • /
    • 2018
  • High temperature and low temperature gaseous nitriding was performed in order to study of the surface hardening and wear properties of the nitrided AISI 410 Martensitic stainless steels. High temperature gaseous nitiridng (HTGN) was carried out using partial pressure $N_2$ gas at $1,100^{\circ}C$ for 10 hour, and Low temperature gaseous nitiridng (LTGN) was conducted in a gas mixture of NH3 and N2 at $470^{\circ}C$ for 10 hour. The nitrided samples were characterized by microhardness measurements, optical microscopy and scanning electron microscopy. The phases were identified by X-ray diffraction and nitrogen concentration was analyzed by GD-OES. The HTGN specimen had a surface hardness of about $700HV_{0.1}$, $350{\mu}m$ of case depth. A ${\sim}50{\mu}m$ thick, $1,250HV_{0.1}$ hard nitrided case formed at the surface of the AISI 410 steel by LTGN, composed nitrogen supersaturated expanded martensite and ${\varepsilon}-Fe_{24}N_{10}$ iron nitrides. Additionally, the results of the wear tests, carried out LTGN specimen was low friction coefficient and high worn mass loss of ball. The increase in wear resistance can be mainly attributed to the increase in hardness and to the lattice distortion caused by higher nitrogen concentration.

Radiographic Classification and its Clinical Features for Metaphyseal Cortical Defect of the Distal Femur (대퇴골 원위부 골간단의 피질골 결손에 대한 방사선학적 분류 및 그에 따른 임상적 경과관찰)

  • Park, Il-Hyung;Oh, Chang-Wug;Min, Woo-Kie
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.5 no.1
    • /
    • pp.17-22
    • /
    • 1999
  • Over 60 cases were enlisted, but only 31 cases among 24 patients were eligible with a minimum follow-up of 1 year and complete medical documents with imaging data. There were 18 boys and 6 girls, and 7 patients had bilateral lesions. The age of the patients ranged from 2 to 20 years(mean:10.5 years). At their first visit, most lesions had a highly characteristic location and radiographic appearance of radiolucent lesion(s) ranging from 1 to 3cm, except for one case of 5.5 cm in the posteromedial comer of distal femoral metaphysis. The margins were generally well-defined, although some were ill-defined. After reviewing our cases from the viewpoint of clinical course and radiographic patterns, we divided these lesions into two types. Type I is the osteolytic lesion excavated into the posteromedial aspect of the distal femur without cortical defect; and type II is the buldged out lesion of the femur with cortical irregularity into the surrounding soft tissues. Both types have distinctive clinical courses. Type I lesions were easy to make a definite diagnosis with plain radiographs alone, but in type II, it was sometimes very difficult to differentiate it from malignant tumors or chronic localized osteomyelitis. For this lesion, Gd-enhanced MRI was the most effective method for differential diagnosis. In this study, biopsy was not necessary to confirm the diagnosis. Clinical symptoms of type I were very minor or even absent. Many of them were accidentally found after minor trauma around the knee joint. Clinical symptoms disappeared far earlier than radiographical lesions. No treatment such as restriction of activity or drugs was necessary. For type II, the clinical symptoms were more accentuated and lasted longer, and it was necessary to restrict the activity for a certain period in many cases. However, all were self-limited.

  • PDF

A Case Study on the Application of Gravel Pile in Soft Ground (Gravel Pile의 현장적용을 위한 시험시공 사례연구)

  • 천병식;고용일;여유현;김백영;최현석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.02a
    • /
    • pp.32-41
    • /
    • 2000
  • Sand drain as a vertical drainage is widely used in soft ground improvement Recently, sand, the principal source of sand drain, is running out. The laboratory model tests were carried out to utilize gravel as a substitute for sand. Though which the characteristics of gravel are compared to those of sand for engineering purpose. Two cylindrical containers for the model test were filled with marine clayey soil from the west coast of Korea with a column in the center, one with sand, the other with gravel. Vibrating wire type piezometers were installed at the distance of 1.0D, 1.5D and 2.0D from the center of the column. The characteristics of consolidation were studied with data obtained from the measuring instrument place on the surface of the container. The parameter study was performed on the marine clayey soil before and after the test in order to verify the effectiveness of the improvement. The clogging effect was checked at various depth in gravel column after the test. In-situ tests area was divided into two areas by material used. One is Sand Drain(SD) and Sand Compaction Pile(SCP) area, the other is Gravel Drain(GD) and Gravel Compaction Pile(GCP) area. Both areas were monitored to obtain the information on settlement, pore water pressure and bearing capacity by measuring instruments for stage loading caused by embankment. The results of measurements were analyzed. According to the test results, the settlement was found to be smaller in gravel drain than in sand drain. The increase in bearing capacity by gravel pile explains the result. The clogging effect was not found in gravel column. It is assumed that gravel is relatively acceptable as a drainage material. Gravel is considered to be a better material than sand for bearing capacity, and it is found that bearing capacity is larger when gravel is used as a gravel compaction pile than as a gravel drain.

  • PDF