• 제목/요약/키워드: GC-determination

검색결과 478건 처리시간 0.024초

연삭동력을 이용한 숫돌수명 판정 (Determination of decision of wheel life using grinding power)

  • 이상태
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.204-209
    • /
    • 1999
  • The dressing time monitoring in cylindrical grinding is very important with respect to machining efficiency. Therefore, the purpose of this paper is to determine the wheel life by monitoring behavior of grinding power for Wa, 19A and GC. For this purpose, we investigated indirectly the attritious wear of grain edge, the loading of grinding wheel and the breakage of grain through the grinding power and the surface roughness under various grinding conditions. From obtained the results, the relationship between the wheel life and the average sectional chip area is examined to guide for the determination of dressing time.

  • PDF

반복적인 막 추출과 GC-MS를 이용한 물 중 BTEX의 분석 (Solvent-free determination of BTEX in water using repetitive membrane extraction followed by GC-MS)

  • 김희갑;김세영;이수형
    • 분석과학
    • /
    • 제24권5호
    • /
    • pp.352-359
    • /
    • 2011
  • 용매를 사용하지 않고 반복적으로 막 추출한 후 저온농축과 GC-MS로 물 중 BTEX를 분석하는 방법을 시도하였다. 물로부터 비공성막의 silicone 막을 투과한 BTEX를 He 기체를 통해 $-100^{\circ}C$의 저온 농축장치로 보낸 후 열 탈착과 GC-MS로 분석하였다. 물 시료(30 mL)는 10 mL/min로 흘려주었고, 한 번 추출된 시료는 다시 되돌려서 두 번 더 추출하였다. Benzene에 대한 회수율은 가장 높아 약 80%인 반면에, ethylbenzene과 xylenes에 대한 회수율은 3.5-10%로 낮은 편이었다. 그렇지만, RSD는 모두 10% 미만이었고 검량선의 직선성($r^2$)도 0.9976-0.9997로 높은 편이었으며, 방법검출한계도 1.8 ${\mu}g$/L 이었다. 이 방법은 짧은 추출 시간, 용매의 미사용 및 분석의 편의성의 장점을 갖고 있다.

GC-MS에 의한 소변 중 Ibuprofen의 대사체 규명 및 대사 연구 (Determination of ibuprofen and its metabolites in human urine by GC-MS)

  • 유대형;조정흠;홍종기
    • 분석과학
    • /
    • 제23권2호
    • /
    • pp.179-186
    • /
    • 2010
  • 본 연구는 건강한 성인남자로부터 ibuprofen의 인체 내 대사물질의 규명 및 배설에 대한 연구를 gas chromatography-mass spectrometry (GC/MS) 법으로 수행하였다. Ibuprofen 복용 후 3시간 단위로 15시간까지 소변을 채취하여 실험하였다. 이 중 glucuronide가 포합된 대사체로부터 포합체를 떼어내기 위해 6 M HCl을 통해 $100^{\circ}C$에서 30분 동안 가열하여 산 가수분해 시켰다. 가수분해 된 뇨 중 ibuprofen과 그 대사체를 추출하기 위하여 액체-액체 추출법을 적용하였다. 모약물과 대사체의 추출 최적조건을 찾기 위하여 pH 3, 5 및 8에서 수행하였으며 그 중 pH 3에서 가장 좋은 회수율을 보여 주었다. 또한 미량의 대사체 검출을 위하여 trimethylsilylation (TMS) 유도체 반응을 적용시킨 후 GC-MS를 이용하여 분석하였다. 본 연구에서는 모약물을 포함한 총 5개의 대사체를 검출하였으며, 이들 대사물질들은 주로 산화과정에 의해 약물 모핵에 hydroxylation 또는 carboxylation된 화합물이었다. 또한 시간대별로 채취한 시료에서 각각의 대사체의 배설율의 변화를 관찰함으로써 시간대별 배설율 및 축적률을 구할 수 있었다.

고체상 추출과 GC/MS를 이용한 소변 중 대마 대사체 (THCCOOH) 분석 (Determination of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THCCOOH) in human urine by solid-phase extraction and GC/MS)

  • 정재철;김진영;인문교;정원조
    • 분석과학
    • /
    • 제19권5호
    • /
    • pp.441-448
    • /
    • 2006
  • 소변 중 대마 남용여부를 판별하는데 기준이 되는 tetrahydrocannabinol (THC)의 대사체 성분인 11-nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol (THCCOOH)를 고체상 추출법 (solid-phase extraction, SPE)과 가스크로마토그래피/질량분석법 (GC/MS)을 이용하여 신속하게 분석 할 수 있는 방법을 제시하였다. 본 실험은 시험관에 소변 3 mL를 취해 염기성 (pH 10) 조건에서 가수분해 한 후, 양이온교환 카트리지를 사용하여 THCCOOH 성분을 선택적으로 추출하고, 증발 건고한 다음 유도체 반응을 시켜 GC/MS로 분석하였다. 그 결과 분석방법의 검출한계 (LOD)는 0.4 ng/mL이고, 정량한계 (LOQ)는 1.2 ng/mL이였다. 검정곡선의 직선성 상관계수 ($r^2$)는 1.2 (LLE는 1.3)~50.0 ng/mL의 농도범위에서 0.999를 나타내었다. 그리고 정밀도 (precision)와 정확도 (accuracy)는 모두 ${\pm}1.20%$ 이내로 안정적이었으며, 회수율(recovery)은 83.6~90.7%로 측정되었다. 액체상 추출법 (liquid-liquid extraction, LLE)과 비교할 때, SPE 방법이 회수율은 낮았지만 검출한계, 정량한계, 정밀도 및 정확도에서는 큰 차이가 없었다. 그러나 LLE 방법은 추출과정에 시간과 노력이 많이 드는 반면, SPE 방법은 상대적으로 추출 조작이 간편하고 신속하게 추출되었으며, 추출 잔류물도 깨끗하였다. SPE를 이용한 추출방법을 다수의 대마 흡연자 소변에 적용하였을 때 기존에 사용하던 LLE 방법보다 간편하고, 신속하게 대마 대사체 분석이 가능하였다.

GC/MS를 이용한 DHOA의 방사선 분해생성물 분석 (Determination of Radiolysis Produce of DHOA by GC/MS)

  • 양한범;이일희;임재관;정동용;김광욱;김종승
    • 방사성폐기물학회지
    • /
    • 제7권1호
    • /
    • pp.17-23
    • /
    • 2009
  • 방사성 액체폐기물에 함유되어 있는 우라늄의 추출제 또는 아미드 (amide) 화합물 추출제를 사용한 용매추출계에서 제 3상 생성 방지제로 사용되는 dihexyloctanamide(DHOA)을 합성하고, 이를 $^{60}Co$ 감마 방사선으로 조사시킬 때 생성된 방사선 분해생성물 (radiolysis product)을 정량 분석하였다. 방사선 조사된 DHOA에 대한 FT-IR 스펙트럼과 방사선 분해생성물에 대한 GC/MS 스펙트럼 그리고 GC/MS-SIM 방법으로 측정한 결과를 근거로 octanoic acid와 dihexylamine 2종의 방사선 분해생성물의 존재를 확인하였으며, 이들 2종 화합물의 표준시약과 tridecane을 내부표준물질(ISTD)로 사용하여 GC/MS-SIM 방법으로 정량 분석하였다. 방사선 분해생성물에 대한 총 이온 크로마토그램에서 나타난 머무름 거동, 분리도 및 해 상도에서 정량 분석할 수 있는 결과를 얻었으며, 총 이온 크로마토그램에서 분리피크가 나타나는 시간은 octanoic acid는 8.65분, tridecane은 9.79분 그리고 dihexylamine은 10.27분이었다. 그리고 DHOA의 방사선 흡수선량이 증가할수록 octanoic acid의 농도는 감소하였으며, dihexylamine의 농도는 증가하였다.

  • PDF

Headspace Hanging Drop Liquid Phase Microextraction and GC-MS for the Determination of Linalool from Evening Primrose Flowers

  • Kim, Nam-Sun;Jung, Mi-Jin;Yoo, Zoo-Won;Lee, Sun-Neo;Lee, Dong-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권12호
    • /
    • pp.1996-2000
    • /
    • 2005
  • Headspace hanging drop liquid phase micro-extraction (HS-HD-LPME) is studied as a novel solvent-based sample pretreatment method for floral volatile aroma compounds. This paper reports on application of the HSHD- LPME combined with GC-MS for the analysis of linalool component emitted from evening primrose flowers. The effect of several variables on the method performance was investigated. Additionally, the separation of enantiomers on a cyclodextrin capillary column was performed to identify chirality of (−)-linalool component. Since the unsurpassed volume of a few micro-liters of solvent is used, there is minimal waste or exposure to toxic organic solvents. This method enables to combine extraction, enrichment, clean-up, and sample introduction into a single step prior to the chromatographic process.

GC/MS와 data system을 이용한 한국산 향끽미종 잎담배의 정유성분 분석 (Analysis of Essential Oils from Korean Aromatic Tobacco Varieties by GC/MS and data system.)

  • 박진우;이운철;김용태;허일
    • 한국연초학회지
    • /
    • 제4권1호
    • /
    • pp.61-66
    • /
    • 1982
  • Essential oil components were isolated from Korean aromatic tobaccos by using a simultaneous distillation and extraction apparatus. The essential oils were analyzed by GC/M S and date system. Forty-two volatile components were identified on the basis of their mass spectra. Determination of contents of essential oil components from Hyangcho and Sohyang was achieved by pseudo-multiple ion selection (Ml S) technique. Varietal differences were detected from the quantitative comparison of the MIS data.

  • PDF

Determination of Methamphetamine and its Metabolite Amphetamine in Biological Fluids from 11 Fatal Gases

  • Yoo, Young-Chan;Chung, Hee-Sun;Choi, Hwa-Kyung
    • Archives of Pharmacal Research
    • /
    • 제16권3호
    • /
    • pp.175-179
    • /
    • 1993
  • Gas chromoatography with flame ionization detector (FID) along with mass spectrometry (GC/MS) were used for the screening and quantification of methamphetamine (MA) and its major metabolite, amphetamine (AM0, in blood and urine in eleven fatal cases in which MA abuse was suspected. Postmortem blood MA varied from $0.5-30.2\;\mu{g/ml}$, while Am levels ranged from none detected (6 of 11 cases) to 4.8 .mu.g/ml. Additionally, distribution studies were performed in three of these cases in which tissue smaples were available for evaluation. Liver contained the highest ocncentration of MA among the tissu samples. In eight of the eleven cases, when no other direct cause of death was evident (i.e. 3 cases of traumatic dath0, either no blood AM was found or the ratio of MA/AM was 3.4 or greater. These data are consistent with acute MA use followed by death due to acute drug intoxication or by the occurrence of hypersensitivity and reverse seen in cases of chronic drug abuse.

  • PDF

면역분석법에서 암페타민류의 교차 반응성 (Cross-reactivity of Amphetamine Analogues in Various Immunoassays)

  • 박미정;최화경;최상길;손행자;임미애;정희선
    • 약학회지
    • /
    • 제47권5호
    • /
    • pp.266-270
    • /
    • 2003
  • We evaluated four commercially available methamphetamine immunoassays for their relative cross-reactivities of amphetamine analogues in human urine: Abbott TDx, Vitalab Selectra and on-site test kits (Accusign MET, SD bioline MET). High cross-reactivities were shown at designer's drugs such as methylenedioxyamphetamine (MDA), methylenedioxymethamphetamine (MDMA) and methylenedioxyethylamphetamine (MDEA) in all of the tested immunoassays. Methoxyphenamine, fenfluramine and phentermine were positive in TDx and Selectra, but were not positive in on-site test kits. Pseudoephedrine, norpseudoephedrine, ephedrine, norephedrine, MDMA, MDA, fenfluramine and phentermine were detected by gas chromatography/mass spectrometry(GC/MS) in false positive urines. Since the overall specificity of any of the devices was not 100%, we found it is important to confirm any positive screening test result, so we developed simultaneous determination of amphetamine analogues in urines. After alkalinization of the urine samples with 6-N NaOH, the analytes were extracted using ethyl acetate, derivatized with pentafluoropropyl anhydride (PFPA) prior at GC/MS analysis.

GC/MS를 이용한 알칼리 폐수 중 ethylene glycol 정량 (Determination of ethylene glycol in alkali wastewater by gas chromatography/mass spectrometry)

  • 박교범;이석근
    • 분석과학
    • /
    • 제17권6호
    • /
    • pp.527-531
    • /
    • 2004
  • Treatment with aqueous sodium hydroxide solution plays an important role to impart certain desirable properties - feel and luster on the surface of polyester fiber. In this process alkali wastewater contains disodium terephthalate, ethylene glycol (EG) and residual sodium hydroxide. In this paper we report a new method containing the pretreatments of derivatization with benzoyl chloride and solvent extraction using pentane. The calibration curve of EG determined by GC/MS-SIM shows a good linearity in the range of 0.1 to $25{\mu}g/mL$ having the standard deviation of ${\leq}8.7%$. The recovery and the detection limit of this method are 91.9-93.7% and $0.05{\mu}g/mL$ respectively.