• Title/Summary/Keyword: GC-MS-SIM

Search Result 318, Processing Time 0.031 seconds

Comparative Study of Extracting Fragrance Allergens by GC-MS/MS

  • Lee, In Ja;Ahn, Jae-Chan;Kim, Bogsoon;Chung, Deukmo
    • Mass Spectrometry Letters
    • /
    • v.8 no.1
    • /
    • pp.18-22
    • /
    • 2017
  • Products containing any one or more of 26 fragrance allergens likely to cause contact allergies, are required under the 2008 domestic cosmetic law to be labeled when their concentrations exceed a certain range. This study focuses on the comparison and development of analytical methods based on headspace-solid phase micro extraction (HS-SPME) and liquid-liquid extraction (LLE) methods followed by GC-MS/MS for 24 of the fragrance allergens excepting for two natural materials in water samples. Using the developed HS-SPME method, 15 of the 24 fragrance allergens were analyzed and 9 compounds which have relatively low $logK_{OW}$ values (below about 2.5) were not extracted, and the correlation coefficient ($r^2$) of the calibration curve for quantification showed linearity of 0.9969 or more, and the method detection limits (MDL) and the limits of quantification (LOQ) were $0.078{\sim}0.582{\mu}g/L$ and $0.261{\sim}1.940{\mu}g/L$, respectively. In the case of using the optimized LLE method, all 24 fragrance allergens were analyzed, and the correlation coefficient ($r^2$) of the calibration curve for quantification showed linearity of 0.9957 or more, MDL and LOQ were $0.020{\sim}0.138{\mu}g/L$ and $0.065{\sim}0.440{\mu}g/L$, respectively.

Quantitative Analysis of Pentachlorophenol in Paper Products (종이재 중의 Pentachlorophenol 정량 분석)

  • Hahn, Airan;Park, Jihye;Choi, Hyeongki;Hong, Sungyeap;Han, Hyechul;Jo, Byoungmuk;Oh, Jungsoo
    • Applied Chemistry for Engineering
    • /
    • v.16 no.3
    • /
    • pp.323-327
    • /
    • 2005
  • Pentachlorophenol (PCP) is a representative compound of chlorophenol derivatives which are especially toxic and potentially carcinogenic compounds in the priority pollutant list of the EPA (Environmental Protection Agency, USA). The aim of this study was to investigate an analysis method of PCP in infinitesimal quantity retained in paper. PCP in paper was pretreated by solid phase extraction (SPE) in a phenyl cartridge. The extracted sample was acetylated or silylated and analyzed with GC/MS-SIM. The detection sensitivity of silylated PCP was improved significantly when compared with those of PCP itself and acetylated PCP. As a test specimen, an office paper and a wallpaper were used.

디클로벤지딘에 폭로된 흰쥐의 간장세포와 방광 상피세포에 형성된 DNA adducts의 $^{32}P-postlabeling$과 GC/MS-SIM에 의한 분석

  • 이진헌;신호상;장미선
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.49-51
    • /
    • 2002
  • To identify and evaluate the dichlorobenzidine(DCB)-DNA adducts in liver cell and bladder epithelial cells by $^{32}$ P-postlabeling and GC/MS-SIM, we orally exposed the dichlorobenzidine (20mg/kh body wt.,/day)to male sprague-dawley rats for 14 days. Two kinds of DCB-DNA adduct were found at the same site of thin layer chromatogram of $^{32}$ P-postlabeling method in liver cells and bladder epithelial cells. In liver cells, relative adduct labeling(RAL) $\times$ 10$^{12}$ of DCB-DNA adduct A1 were 34.1$\pm$3.71 and 69.9$\pm$5.02, that of adduct A2 were 74.1$\pm$10.1 and 105.1$\pm$10.1 on 10 and 14 days after treatment, respectively. And in bladder epithelia cells, RAL $\times$ 10$^{12}$ of DCB-DNA adduct A1 were 5.92$\pm$1.60 and 15.9$\pm$1.31, that of adduct A2 were 9,81$\pm$2.81 and 22.8$\pm$1.79 on 10 and 14 days after treatment, respectively. DCB metabolites formed DNA adducts were monoacetyl-dichlorobenzidine(acDCB) and diacety1-dichlorobenzidine(di-acDCB), which was identify by gas chromatography/mass spectrometry-scan ionization mode(GC/MS-SIM), along with hydrolysis, extraction and TFA(trifluoroacetyl anhyride) derivatization with DCB-DNA adducts isolated from live cells and bladder epithelial cells. The base peak of acDCB were 252 and 294 m/z, and that of di-acDCB were 252, 294 and 336 m/z. In conclusion, the exposed DCB formed two kinds of DCB-DNA adduct, the proximate materials of that were acDCB and di-acDCB in liver and bladder epithlial cells. And the above GC/MS-SIM method was found the DCB-DNA adducts could be monitoring by gas chromatography.

  • PDF

A Rapid, Simple Determination of Sulfur-containing Compounds and Methylmalonic Acid on Plasma using GC-MS-SIM for the Diagnosis of Homocysteinemia (혈장 중 황함유 화합물과 메틸말론산의 신속 간편한 분석법 개발; GC-MS-SIM을 이용한 호모시스테인혈증의 진단)

  • Yoon, Hye-Ran;Thapa, Maheshwor
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.15 no.3
    • /
    • pp.138-146
    • /
    • 2015
  • Purpose: If early diagnosis is not made, patients with metabolic disorders as homocystinemia rapidly progress to physical defect or mental retardation resulted in storage of the toxic material into the brain. Therefore, it is necessary to develop an analytical method for a rapid screening and/or correct confirmation diagnosis. Methods: The standard solution of sulfur amino acids spiked plasma was subjected to protein precipitation with methanol, and then consecutively derivatized with trimethylsilyl (TMS) and trifluoroacyl (TFA) and determined by GC-MS. The formation of TMS derivative of the hydroxyl and TFA derivative of amino functional group was performed by BSTFA and MBTFA, respectively. Selective ion monitoring (SIM) mode was used for quantification with selected specific ions. Results: A calibration curve on standard spiked pooled plasma showed a linear relationship with correlation coefficient of 0.9936-0.9992 for all compounds over the range of 0.1-300 ng. The precision and accuracy were within S.D. of 1-15% and RSD of 1-15% for intra-day assay at 2 ng/mL, 15 ng/mL and 30 ng/mL. LOD and LOQ was 0.4 ng/mL and 4 ng/mL respectively. Conclusion: A rapid analytical method was developed to quantify sulfur amino acids and methyl malonic acid, after two-step derivatization procedure with good sensitivity and specificity on human plasma. Advantages of a new method are simplicity and rapidity. The method could be useful for routine analysis, diagnosis of homocysteinemia.

Analysis of Octylphenol, Nonylphenol, Di-octylphthalate in Sewage Sludge by GC/MS-SIM (GC/MS-SIM에 의한 하수 슬러지중에 포함된 Octylphenol, Nonylphenol, Di-octylphthalate의 정량)

  • Kim, Jong-Hun
    • Analytical Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.248-255
    • /
    • 1999
  • Sewage sludge samples were extracted with dichlomethane by Soxhlet extraction. The extracts were analysed for the endocrine disrupting compounds (EDC), octylphenol(OP), nonylphenol (NP) and bis (2-ethylhexyl)phthalate (DOP) using GC/MS-SIM. In industrial sewage sludge (sample Z-1) the concentration of NP and DOP were respectively $1168{\mu}g/g$ and $1172{\mu}g/g$ whereas in domestic sludge (sample Z-2) the concentration were respectively $10.8{\mu}g/g$ and $80{\mu}g/g$. OP was not detected in Z-2, but detected a small amount in Z-2 of the samples. Environmental EDC have been shown to affect the fertility of range of living organisms, including humans, and the high levels of NP and DOP in industrial sewage sludge could have serious implications for the reproductive health of humans particularly if the compounds entered the human food chain through water or the ingestion of vegetables or animal products.

  • PDF

Development of Analytical Method of Polycyclic Aromatic Hydrocarbons Deposited on Tree Leaves by GC/MS (GC-MS 에 의한 나뭇잎에 침착된 다환방향족 탄화수소의 분석)

  • Chun, Man-Young;Lim, Ceoel-Soo;Kim, Tae-Wook
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.2
    • /
    • pp.135-139
    • /
    • 1999
  • A new effective and economic method was developed, removing interferences such as chlorophyll and lipid from leaves with small amounts of reagents and solvents in order to analyse PAHs(Polycyclic Aromatic Hydrocarbons). The extract from a soxhlet containing $4{\sim}5g$ of leaves and 100ml of dichlormethane and refluxed for 20 hrs was concentrated and eluted with 60ml of a hexane:dichloromethane (1:1) mixture through a column of 9mm wide inner diameter and 130mm long, packed from the bottom with 2.5g of $Al_2O_3$, 1.5g of $SiO_2$and 2g of anhydrous $Na_2SO_4$. The eluent was concentrated and loaded on a GPC column of 20mm wide inner diameter and 280mm long, packed with 12g of Bio-beads. The column was washed with 37ml of the hexane:dichloromethane(1:1) mixture. Another 43ml of the mixture was eluted as a PAH fraction and collected. This eluent was concentrated under gentle nitrogen to $50{\mu}l$ and analysed using GC-MS. The recoveries, obtained by comparing with the amounts of the internal standards of deuterated PAHs were $43.3{\sim}107.5%$(RSD $2.2{\sim}9.5%$).

  • PDF

Determination of personal care products in aquatic environmental samples by GC/MS (GC/MS를 이용한 수질환경시료 중 personal care products의 분석)

  • Lee, In-Jung;Lee, Chul-Gu;Heo, Seong-Nam;Lee, Jae-Gwan
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.477-484
    • /
    • 2010
  • Personal care products are a diverse group of synthetic organic chemicals such as antimicrobial compounds, UV filters and organo-phosphate flame retardants and derived from individual usages of soaps, toothpaste and cosmetics. It has been detected in municipal sewage effluent and various environmental samples such as surface water, marine, soil, sediment and aquatic biota in many countries. The occurrence of personal care products in environmental samples could negatively impact the health of the ecosystem and humans, due to persistent, long-term chronic exposure of aquatic organisms. In this study, fifteen personal care products in aquatic environmental samples were determined by gas chromatography-mass spectrometry (GC-MS) with liquidliquid extraction (LLE). Method detection limits were in the range of $0.004\sim0.273\;{\mu}g/L$. Two compounds (TCEP, TCPP) were detected in surface waters and seven compounds (triclosan, 4-MBC, EHMC, BP-3, TCEP, TPP, TBEP) were detected in sewage treatment plants (STP) influents or effluents.

Simultaneous Determination of Biliary Free and Phospholipid Fatty Acids Using Gas Chromatography-Mass Spectrometry (GC-MS를 이용한 담즙내 유리 지방산 및 인지질 지방산들의 동시 분석)

  • Yang, Yoon Jung;Lee, Seon Hwa;Chung, Bong Chul
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.592-600
    • /
    • 2000
  • The concentration of free fatty acids and fatty acid composition as well as cholesterol supersaturation in bile may be an important factor in the gallstone formation. Therefore, we simultaneously determinded 23 fatty acids in bile by selected ion monitoring (SIM) method of gas chromatography-mass spectrometry (GC-MS). Biliary fatty acids were extracted by aminopropyl column and the extracts with (phospholipid fraction) or without (free fatty acid fraction) alkaline hydrolysis of phospholipid were derivatized with MSTFA/TMCS (N-methyl-N-trimethylsilyl-trifluoroacetamide/trimethylsilylchloride) mixture in order to be detected on the GC-MS. The recovery range of this method was 61.1-99.0% and the RSD value of within-a-day and day-to-day test were 3.1-25.6% and 3.8-27.0%, respectively. Using this method, biliary profile was investigated in the bile of normal controls and patients with gallstones. The amounts and their distribution of free and phospholipid fatty acids showed different pattern between normal subjects and patients.

  • PDF

Separation of Chromophoric Substance from Sappanwood under Different Extraction Conditions (염료 추출조건에 따른 소목의 색소성분 분리 거동)

  • Ahn, Cheun-Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.12
    • /
    • pp.1653-1661
    • /
    • 2007
  • The research aimed to establish the standard extraction procedure for examining brazilin, the major chromophoric substance of Sappanwood, using GC-MS with the ultimate goal of identifying the sappanwood dye in severely faded archaeological textiles. The amount of brazilin represented by the GC abundance was the largest when acetone was used as the extraction medium, followed by methanol. Shaking plate operated at room temperature was more effective than the waterbath shaker which was operated at $30^{\circ}C$. In both cases, the extraction method which incorporated one hour pre-soaking before the 12 hours of actual extraction resulted in a larger amount of brazilin detection than the extraction procedure without the one hour pre-soaking. In case of water extraction, pH 5 resulted in the most effective pH level for the extraction of brazilin, The best GC-MS parameter for detecting brazilin was to set the column temperature initially at $50^{\circ}C$. gradually increase to $210^{\circ}C$ at a $23^{\circ}C/min$ rate, finally increase to $305^{\circ}C$ at $30^{\circ}C/min$ rate, and hold for 14 minutes, and the MSD scan range at $75{\sim}400m/z$.

Development of Analytical Technology Using the HS-SPME-GC/FID for Monitoring Aromatic Solvents in Urine

  • Lee, Mi-Young;Chung, Yun Kyung;Shin, Kyong-Sok
    • Mass Spectrometry Letters
    • /
    • v.4 no.1
    • /
    • pp.18-20
    • /
    • 2013
  • Headspace solid phase micro-extraction gas chromatography/flame ionization detection (HS-SPME-GC/FID) method was compared with headspace gas chromatography/mass selective detection (HS-GC/MS). Organic solvent-spiked urine as well as urine samples from workspace was analyzed under optimal condition of each method. Detection limit of each compound by HS-SPME-GC/FID was $3.4-9.5{\mu}g/L$, which enabled trace analysis of organic solvents in urine. Linear range of each organic solvent was $10-400{\mu}g/L$, with fair correlation coefficient between 0.992 and 0.999. The detection sensitivity was 4 times better than HS-GC/MS in selected ion monitoring (SIM) mode. Accuracy and precision was confirmed using commercial reference material, with accuracy around 90% and precision less than 4.6% of coefficient of variance. Among 48 urine samples from workplace, toluene was detected from 45 samples in the range of $20-324{\mu}g/L$, but no other solvents were found. As a method for trace analysis, SPME HS GC/FID showed high sensitivity for biological monitoring of organic solvent in urine.