• 제목/요약/키워드: GB

검색결과 1,352건 처리시간 0.027초

한중일의 조도기준 비교분석 : 주택조도기준을 중심으로 (Comparative Analysis on Recommended Levels of Illumination in Korea·China·Japan: Focused on Recommended Levels of Illumination for Housing)

  • 송대선;강혜경;조영미;안옥희
    • 조명전기설비학회논문지
    • /
    • 제28권4호
    • /
    • pp.1-8
    • /
    • 2014
  • This study compared the recommended levels of illumination for housing. KS Recommended Levels of Illumination (KS A 3011) in Korea, Recommended Levels of Illumination (GB 50034-2004) in China and Recommended Levels of Illumination (JIS Z 9110) in Japan are compared. The results are as below. First, recommended levels of illumination used in Korea China Japan are suggested by different locations and activities. However, classification for application scope is set differently. There are 10 areas for classification used in Korea, 5 areas in China, and 13 areas in China. When medium levels for classification are included as classification level, total of 15 areas are used for classification in China. Second, when considering there are 15 areas of application scope in China for recommended levels of illumination, there are 7 areas that are commonly used in Korea China Japan. 7 areas include stadium, factories, hospitals, office, shopping center, houses and hospitals. Third, working surface is considered as the height for recommended levels of illumination in Korea China Japan. Korea and Japan consider all working positions, standing and sitting position, when deciding the height. However, China only considers the standing position. Fourth, application scope for recommended levels of illumination for housing are classified in 16 areas in Korea, 5 in China and 18 in Japan. Thus, the application scope for recommended levels of illumination in housing in Korea is similar to Japan. However, there are only 5 areas used in China such as living room, bedroom, dining room, kitchen and sanitary room. Fifth, recommended levels of illumination is classified in 3 levels such as Lowest-Moderate-Highest while China and Japan only have standard recommended levels of illumination. Sixth, when observing recommended levels of illumination by type of activities, Japan classified the activities in greatest detail followed by Korea and then China. Seventh, Recommended levels of illumination differs by each country.

Efficiency to Discovery Transgenic Loci in GM Rice Using Next Generation Sequencing Whole Genome Re-sequencing

  • Park, Doori;Kim, Dongin;Jang, Green;Lim, Jongsung;Shin, Yun-Ji;Kim, Jina;Seo, Mi-Seong;Park, Su-Hyun;Kim, Ju-Kon;Kwon, Tae-Ho;Choi, Ik-Young
    • Genomics & Informatics
    • /
    • 제13권3호
    • /
    • pp.81-85
    • /
    • 2015
  • Molecular characterization technology in genetically modified organisms, in addition to how transgenic biotechnologies are developed now require full transparency to assess the risk to living modified and non-modified organisms. Next generation sequencing (NGS) methodology is suggested as an effective means in genome characterization and detection of transgenic insertion locations. In the present study, we applied NGS to insert transgenic loci, specifically the epidermal growth factor (EGF) in genetically modified rice cells. A total of 29.3 Gb (${\sim}72{\times}coverage$) was sequenced with a $2{\times}150bp$ paired end method by Illumina HiSeq2500, which was consecutively mapped to the rice genome and T-vector sequence. The compatible pairs of reads were successfully mapped to 10 loci on the rice chromosome and vector sequences were validated to the insertion location by polymerase chain reaction (PCR) amplification. The EGF transgenic site was confirmed only on chromosome 4 by PCR. Results of this study demonstrated the success of NGS data to characterize the rice genome. Bioinformatics analyses must be developed in association with NGS data to identify highly accurate transgenic sites.

Derivation of response spectrum compatible non-stationary stochastic processes relying on Monte Carlo-based peak factor estimation

  • Giaralis, Agathoklis;Spanos, Pol D.
    • Earthquakes and Structures
    • /
    • 제3권5호
    • /
    • pp.719-747
    • /
    • 2012
  • In this paper a novel approach is proposed to address the problem of deriving non-stationary stochastic processes which are compatible in the mean sense with a given (target) response (uniform hazard) spectrum (UHS) as commonly desired in the aseismic structural design regulated by contemporary codes of practice. The appealing feature of the approach is that it is non-iterative and "one-step". This is accomplished by solving a standard over-determined minimization problem in conjunction with appropriate median peak factors. These factors are determined by a plethora of reported new Monte Carlo studies which on their own possess considerable stochastic dynamics merit. In the proposed approach, generation and treatment of samples of the processes individually on a deterministic basis is not required as is the case with the various "two-step" approaches found in the literature addressing the herein considered task. The applicability and usefulness of the approach is demonstrated by furnishing extensive numerical data associated with the elastic design UHS of the current European (EC8) and the Chinese (GB 50011) aseismic code provisions. Purposely, simple and thus attractive from a practical viewpoint, uniformly modulated processes assuming either the Kanai-Tajimi (K-T) or the Clough-Penzien (C-P) spectral form are employed. The Monte Carlo studies yield damping and duration dependent median peak factor spectra, given in a polynomial form, associated with the first passage problem for UHS compatible K-T and C-P uniformly modulated stochastic processes. Hopefully, the herein derived stochastic processes and median peak factor spectra can be used to facilitate the aseismic design of structures regulated by contemporary code provisions in a Monte Carlo simulation-based or stochastic dynamics-based context of analysis.

Axial compressive behavior of special-shaped concrete filled tube mega column coupled with multiple cavities

  • Wu, Haipeng;Qiao, Qiyun;Cao, Wanlin;Dong, Hongying;Zhang, Jianwei
    • Steel and Composite Structures
    • /
    • 제23권6호
    • /
    • pp.633-646
    • /
    • 2017
  • The compressive behavior of special-shaped concrete filled tube (CFT) mega column coupled with multiple cavities is studied by testing six columns subjected to cyclically uniaxial compressive load. The six columns include three pentagonal specimens and three hexagonal specimens. The influence of cavity construction, arrangement of reinforcement, concrete strength on failure feature, bearing capacity, stiffness, and residual deformation is examined. Experimental results show that cavity construction and reinforcements make it possible to form a combined confinement effect to in-filled concrete, and the two groups of special-shaped CFT columns show good elastic-plastic compressive behavior. As there is no axial bearing capacity calculation method currently available in any Code of practice for special-shaped CFT columns, values predicted by normal CFT column formulas in GB50936, CECS254, ACI-318, EC4, AISCI-LRFD, CECS159, and AIJ are compared with tested values. The calculated values are lower than the tested values for most columns, thus the predicted bearing capacity is safe. A reasonable calculation method by dividing concrete into active and inactive confined regions is proposed. And high accuracy shows in estimating special-shaped CFT columns either coupled with multiple cavities or not. In addition, a finite element method (FEM) analysis is conducted and the simulated results match the test well.

위상변조를 이용한 저 전력 입출력 인터페이스 회로 (Low Power Serial Interface I/O by using Phase Modulation)

  • 박형민;강진구
    • 대한전자공학회논문지SD
    • /
    • 제48권2호
    • /
    • pp.1-6
    • /
    • 2011
  • 본 논문은 위상 변조를 이용한 직렬 인터페이스 입출력 회로를 설계 하였다. 설계된 직렬 입출력 인터페이스 회로는 수신부와 송신부로 구성되어 있다. 제안하는 위상변조 데이터 전송 방식은 상승 에지 위상은 고정시켜 클록 정보로 사용하고 하강에지 위상을 전송되는 데이터에 따라 변조하여 오프-칩 인터페이스에서도 적용 가능한 효율적인 데이터 전송 방식을 사용한다. 제안하는 회로는 16개의 하강 에지 위상을 사용하여 한 클록 주기마다 4비트씩 데이터를 전송함으로써 시스템에서 사용되는 클록 속도보다 4배 빠른 전송 속도를 갖는 저 전력 회로다. 본 논문에서는 0.13um CMOS 공정을 이용하여 설계 및 검증을 수행 하였고, 칩 면적 $2mm^2$ 하에서 1Gb/s 전송 속도와 12mW의 소비 전력을 갖는다.

A High Performance Co-design of 26 nm 64 Gb MLC NAND Flash Memory using the Dedicated NAND Flash Controller

  • You, Byoung-Sung;Park, Jin-Su;Lee, Sang-Don;Baek, Gwang-Ho;Lee, Jae-Ho;Kim, Min-Su;Kim, Jong-Woo;Chung, Hyun;Jang, Eun-Seong;Kim, Tae-Yoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제11권2호
    • /
    • pp.121-129
    • /
    • 2011
  • It is progressing as new advents and remarkable developments of mobile device every year. On the upper line reason, NAND FLASH large density memory demands which can be stored into portable devices have been dramatically increasing. Therefore, the cell size of the NAND Flash memory has been scaled down by merely 50% and has been doubling density each per year. [1] However, side effects have arisen the cell distribution and reliability characteristics related to coupling interference, channel disturbance, floating gate electron retention, write-erase cycling owing to shrinking around 20nm technology. Also, FLASH controller to manage shrink effect leads to speed and current issues. In this paper, It will be introduced to solve cycling, retention and fail bit problems of sub-deep micron shrink such as Virtual negative read used in moving read, randomization. The characteristics of retention, cycling and program performance have 3 K per 1 year and 12.7 MB/s respectively. And device size is 179.32 $mm^2$ (16.79 mm ${\times}$ 10.68 mm) in 3 metal 26 nm CMOS.

Comparative Transcriptome Analysis of Queen, Worker, and Larva of Asian Honeybee, Apis cerana

  • Kim, Woo Jin;Lee, Seok Hee;An, Saes Byeol;Kim, Song Eun;Liu, Qin;Choi, Jae Young;Je, Yeon Ho
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제27권2호
    • /
    • pp.271-276
    • /
    • 2013
  • The Asian honeybee, Apis cerana, is a native honeybee species in Korea which is important in agriculture for pollination and honey production. For better understanding of the physiology of A. cerana, high-throughput Illumina transcriptome sequencing was performed to analyze the gene expression profiles of queen, worker, and larva. A total of 219,799,682 clean reads corresponding to 22.2 Gb of nucleotide sequences was obtained from the whole body total RNA samples. The Apis mellifera reference mRNA sequence database was used to measure the gene expression level with Bowtie2 and eXpress software, and the Illumina short reads were then mapped to 11,459 out of 11,736 A. mellifera reference genes. Total of 9,221 genes with FPKM value greater than 5 of each sample group were subjected to eggNOG with BLASTX for gene ontology analysis. The differential gene expression between queen and worker, and worker and larva were analyzed to screen the overexpressed genes in each sample group. In the queen and worker sample group, total of 1,766 genes were differentially expressed with 887 and 879 genes overexpressed over two folds in queen and worker, respectively. In the worker and larva sample group, total of 1,410 genes were differentially expressed with 1,009 and 401 genes overexpressed over two folds in worker and larva, respectively.

담정격으로 호전된 불면증 치험례 (A Report on the Insomnia Treated Successfully by Acupuncture)

  • 이현수;임성철;김재수;이윤규;이현종;한창현;이봉효
    • Korean Journal of Acupuncture
    • /
    • 제31권4호
    • /
    • pp.234-239
    • /
    • 2014
  • Objectives : The purpose of this study is to report that acupuncture of Damjeonggyeok(tonifying GB in Sa-Am acupucture) can be effective on chronic insomnia. Methods : The patients were treated with Sa-Am acupucture(Damjeonggyeok) added with HT8 and KI6, once a week. Treatments were performed for 20 minutes. The effectiveness was evaluated using total sleep hours and subjective sleep quality based on the Insomnia Severity Index. Result and Conclusions : In all patients, the sleep quality evaluated with the Insomnia Severity Index has shown amelioration and sleeping time was increased. Also, they quit the insomnia pills. Acupuncture at Damjeonggyeok added with HT8 and KI6 seems to be able to one of useful therapies for the sleep disorder in chronic insomnia.

The Task of the Fashion Designer in Different Types of Domestic Women's Apparel Brands - Focusing on the Fashion Merchandising Process -

  • Kwon, Hae-Sook;Lee, Eun-A
    • 패션비즈니스
    • /
    • 제8권6호
    • /
    • pp.90-102
    • /
    • 2004
  • The purpose of this research is to identify the phases of the fashion merchandising process and the range of the fashion designer's work as well as performing degree at each stage according to the brand types of domestic women's apparel. The preliminary research was conducted with the chief designers of five woman's apparel manufactures located in Seoul and the questionnaires were collected from 192 fashion designers. They were measured by the five point Likert-type scales. For a data analysis, the Pearson's Correlation, ANOVA, Sheffe Test, MANOVA were used with SPSS V. 11.0. The results are as follows; 1. The steps which fashion designers of domestic apparel brand take in fashion merchandising process have been identified in 7 stages- Environment Information, Target Market Planning, Design Planning, Design Development, Price Settlement, Presentation & Line Release, Production. 2. The task achievement level of fashion designers in fashion merchandising process differs in brand types as well as in fashion merchandising stages. In NB, the designer's work was conducted in order of Design Planning(M=4.58)$\to$Presentation & Line release(M=4.31)$\to$ Environment Information(M=3.83)$\to$Target Market Planning(M=3.13). In DB, in order of Price Settlement (M=4.80)$\to$Production(M=4.33)$\to$Design Development(M=4.27)$\to$Design Planning(M=3.77)$\to$Presentation & Line release(M=3.20)$\to$Environment Information (M2.70). In GB, in order of Production(M=4.38)$\to$Design Planning(M=4.22)$\to$Price Settlement(M4.16)$\to$Environment Information(M=3.83)$\to$Merchandising Target Market (M=3.72)$\to$Design Development(M=3.65). 3. Considering the other factors such as sales, the amount of owning shops, item amounts that are related to the company size, this study shows that only the brand type affects designer's task achievement.

Shear capacity of stud shear connectors with initial damage: Experiment, FEM model and theoretical formulation

  • Qi, Jianan;Wang, Jingquan;Li, Ming;Chen, Leilei
    • Steel and Composite Structures
    • /
    • 제25권1호
    • /
    • pp.79-92
    • /
    • 2017
  • Initial damage to a stud due to corrosion, fatigue, unexpected overloading, a weld defect or other factors could degrade the shear capacity of the stud. Based on typical push-out tests, a FEM model and theoretical formulations were proposed in this study. Six specimens with the same geometric dimensions were tested to investigate the effect of the damage degree and location on the static behavior and shear capacity of stud shear connectors. The test results indicated that a reduction of up to 36.6% and 62.9% of the section area of the shank could result in a dropping rate of 7.9% and 57.2%, respectively, compared to the standard specimen shear capacity. Numerical analysis was performed to simulate the push-out test and validated against test results. A parametrical study was performed to further investigate the damage degree and location on the shear capacity of studs based on the proposed numerical model. It was demonstrated that the shear capacity was not sensitive to the damage degree when the damage section was located at 0.5d, where d is the shank diameter, from the stud root, even if the stud had a significant reduction in area. Finally, a theoretical formula with a reduction factor K was proposed to consider the reduction of the shear capacity due to the presence of initial damage. Calculating K was accomplished in two ways: a linear relationship and a square relationship with the damage degree corresponding to the shear capacity dominated by the section area and the nominal diameter of the damaged stud. This coefficient was applied using Eurocode 4, AASHTO LRFD (2014) and GB50017-2003 (2003) and compared with the test results found in the literature. It was found that the proposed method produced good predictions of the shear capacity of stud shear connectors with initial damage.