• Title/Summary/Keyword: GAs analysis

Search Result 9,076, Processing Time 0.041 seconds

Simultaneous Analysis of 13 Pesticides in Groundwater and Evaluation of its Persistent Characteristics

  • Song, Dahee;Park, Sunhwa;Jeon, Sang-Ho;Kim, Ki-In;Hwang, Jong Yeon;Kim, Moonsu;Jo, Hun-Je;Kim, Deok-hyun;Lee, Gyeong-Mi;Kim, Hye-Jin;Kim, Tae-Seung;Chung, Hyen Mi;Kim, Hyun-Koo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.50 no.5
    • /
    • pp.434-451
    • /
    • 2017
  • For this study, groundwater samples for 3 years from 2011 through 2013 were collected at 106 groundwater monitoring site in Korea. These groundwater samples were analyzed for 13 pesticides such as cabofuran, pentachlorobenzene, hexachlorobenzene, simazine, atrazine, lindane (gamma-HCH), alachlor, heptachlor, chlordane (total), endosulfan (1, 2), dieldrin, endrin, 4,4-DDT. The objectives of this study were to determine the detection frequency and their concentrations of 13 pesticides and evaluate the health risk level considering ingestion, inhalation, and skin contact using concentrations of 13 pesticides in groundwater samples. An analysis was used for the simultaneous determination for 13 pesticides using GC-MS. GC-MS was performed on HP-5ms, using helium ($1ml\;min^{-1}$) as carrier gas. The average recoveries of the pesticides were from 92.8% to 120.8%. The limits of detection (LODs) were between $0.004{\mu}g\;L^{-1}$ and $0.118{\mu}g\;L^{-1}$ and the limits of quantification (LOQs) were between $0.012{\mu}g\;L^{-1}$ and $0.354{\mu}g\;L^{-1}$. 106 groundwater wells were selected. 54 wells were from well to monitor background groundwater quality and 52 wells were from well to monitor groundwater quality in industrial or contamination source area. Eight pesticides including pentachlorobenzene, lindane (Gamma-HCH), heptachlor, chlordane (total), Endosulfan (1, 2), dieldrin, endrin, and 4,4-DDT were not detected in groundwater samples. The detection frequency for hexachlorobenzene, alachlor, carbofuran and simazine was 23.4%, 11.4%, 7.3%, and 1.0%, respectively. Atrazine was detected once in 2011. The average concentrations were $0.00423{\mu}g\;L^{-1}$ for carbofuran, $0.000243{\mu}g\;L^{-1}$ for alachlor, $0.00015{\mu}g\;L^{-1}$ for simazine, and $0.00001{\mu}g\;L^{-1}$ for hexachlorobenzene. The detection frequency of hexachlorobenzene was high, but the average concentration was low. In the contaminated groundwater, the detection frequency for hexachlorobenzene, alachlor, carbofuran, simazine and atrazine was 26.1%, 21.3%, 7.1%, 1.9% and 0.3%, respectively. In the uncontaminated groundwater, detection frequency for hexachlorobenzene, carbofuran and alachlor were 20.2%, 7.5%, and 1.9% respectively. Simazine and atrazine were not detected at uncontaminated groundwater wells. According to the purpose of groundwater use, atrazine was detected for agricultural groundwater use. Hexachlorobenzene showed high detection frequency at agricultural groundwater use area where the animal feeding area and golf course area were located. Alachlor showed more than 50% detection frequency at cropping area, pollution concern river area, and golf course area. Atrazine was detected in agricultural water use area. By land use, the maximum detection frequency of alachlor was found near an orchard. For human risk assessment, the cancer risk for the 5 pesticides was between $10^{-7}$ and $10^{-10}$, while the non-cancer risk (HQ value) was between $10^{-4}$ and $10^{-6}$. For conclusion, these monitoring study needs to continue because of the possibility of groundwater contamination based on various purpose of groundwater use.

An historical analysis on the carbon lock-in of Korean electricity industry (한국 전력산업의 탄소고착에 대한 역사적 분석)

  • Chae, Yeoungjin;Roh, Keonki;Park, Jung-Gu
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.125-148
    • /
    • 2014
  • This paper performs a historical analysis on the various factors contributing to the current carbon lock-in of Korean electricity industry by using techo-institutional complex. The possibilities of the industry's carbon lock-out toward more sustainable development are also investigated. It turns out that market, firm, consumer, and government factors are all responsible for the development of the carbon lock-in of Korean power industry; the Korean government consistently favoring large power plants based on the economy of scale; below-cost electricity tariff; inflation policy to suppress increases in power price; rapid demand growth in summer and winter seasons; rigidities of electricity tariff; and expansion of gas-fired and imported coal-fired large power plants. On the other hand, except for nuclear power generation and smart grid, environment laws and new and renewable energy laws are the other remaining factors contributing to the carbon lock-out. Considering three key points that Korea is an export-oriented economy, the generation mix is the most critical factor to decide the amounts of carbon emission in the power industry, and the share of industry and commercial power consumption is over 85%, it is unlikely that Korea will achieve the carbon lock-out of power industry in the near future. Therefore, there are needs for more integrated approaches from market, firm, consumer, and government all together in order to achieve the carbon lock-out in the electricity industry. Firstly, from the market perspective, it is necessary to persue more active new and renewable energy penetration and to guarantee consumer choices by mitigating the incumbent's monopoly power as in the OECD countries. Secondly, from the firm perspective, the promotion of distributed energy system is urgent, which includes new and renewable resources and demand resources. Thirdly, from the consumer perspective, more green choices in the power tariff and customer awareness on the carbon lock-out are needed. Lastly, the government shall urgently improve power planning frameworks to include the various externalities that were not properly reflected in the past such as environmental and social conflict costs.

Innovation Technology Development & Commercialization Promotion of R&D Performance to Domestic Renewable Energy (신재생에너지 기술혁신 개발과 R&D성과 사업화 촉진 방안)

  • Lee, Yong-Seok;Rho, Do-Hwan
    • Journal of Korea Technology Innovation Society
    • /
    • v.12 no.4
    • /
    • pp.788-818
    • /
    • 2009
  • Renewable energy refers to solar energy, biomass energy, hydrogen energy, wind power, fuel cell, coal liquefaction and vaporization, marine energy, waste energy, and liquidity fuel made out of byproduct of geothermal heat, hydrogen and coal; it excludes energy based on coal, oil, nuclear energy and natural gas. Developed countries have recognized the importance of these energies and thus have set the mid to long term plans to develop and commercialize the technology and supported them with drastic political and financial measures. Considering the growing recognition to the field, it is necessary to analysis up-to-now achievement of the government's related projects, in the standards of type of renewable energy, management of sectional goals, and its commercialization. Korean government is chiefly following suit the USA and British policies of developing and distributing renewable energy. However, unlike Japan which is in the lead role in solar rays industry, it still lacks in state-directed support, participation of enterprises and social recognition. The research regarding renewable energy has mainly examinedthe state of supply of each technology and suitability of specific region for applying the technology. The evaluation shows that the research has been focused on supply and demand of renewable as well as general energy and solution for the enhancement of supply capacity in certain area. However, in-depth study for commercialization and the increase of capacity in industry followed by development of the technology is still inadequate. 'Cost-benefit model for each energy source' is used in analysis of technology development of renewable energy and quantitative and macro economical effects of its commercialization in order to foresee following expand in related industries and increase in added value. First, Investment on the renewable energy technology development is in direct proportion both to the product and growth, but product shows slightly higher index under the same amount of R&D investment than growth. It indicates that advance in technology greatly influences the final product, the energy growth. Moreover, while R&D investment on renewable energy product as well as the government funds included in the investment have proportionate influence on the renewable energy growth, private investment in the total amount invested has reciprocal influence. This statistic shows that research and development is mainly driven by government funds rather than private investment. Finally, while R&D investment on renewable energy growth affects proportionately, government funds and private investment shows no direct relations, which indicates that the effects of research and development on renewable energy do not affect government funds or private investment. All of the results signify that although it is important to have government policy in technology development and commercialization, private investment and active participation of enterprises are the key to the success in the industry.

  • PDF

Synthesis of Ultrasound Contrast Agent: Characteristics and Size Distribution Analysis (초음파 조영제의 합성 및 합성된 초음파 조영제의 특성 분석)

  • Lee, Hak Jong;Yoon, Tae Jong;Yoon, Young Il
    • Ultrasonography
    • /
    • v.32 no.1
    • /
    • pp.59-65
    • /
    • 2013
  • Purpose: The purpose of this study is to establish the methodology regarding synthesis of ultrasound contrast agent imaging, and to evaluate the characteristics of the synthesized ultrasound contrast agents, including size or degradation interval and image quality. Materials and Methods: The ultrasound contrast agent, composed of liposome and SF6, was synthesized from the mixture solution of $21{\mu}mol$ DPPC (1, 2-Dihexadecanoyl-sn-glycero-3-phosphocholine, $C_{40}H_{80}NO_8P$), $9{\mu}mol$ cholesterol, $1.9{\mu}mol$ of DCP (Dihexadecylphosphate, $[CH_3(CH_2)_{15}O]_2P(O)OH$), and chloroform. After evaporation in a warm water bath and drying during a period of 12-24 hours, the contrast agent was synthesized by the sonication process by addition of buffer and SF6 gas. The size of the contrast agent was controlled by use of either extruder or sonication methods. After synthesis of contrast agents, analysis of the size distribution of the bubbles was performed using dynamic light scattering measurement methods. The degradation curve was also evaluated by changes in the number of contrast agents via light microscopy immediate, 12 hours, 24 hours, 36 hours, 48 hours, 60 hours, 72 hours, and 84 hours after synthesis. For evaluation of the role as an US contrast agent, the echogenicity of the synthesized microbubble was compared with commercially available microbubbles (SonoVue, Bracco, Milan, Italy) using a clinical ultrasound machine and phantom. Results: The contrast agents were synthesized successfully using an evaporation-drying-sonication method. The majority of bubbles showed a mean size of 154.2 nanometers, and they showed marked degradation 24 hours after synthesis. ANOVA test revealed a significant difference among SonoVue, synthesized contrast agent, and saline (p < 0.001). Although no significant difference was observed between SonoVue and the synthesized contrast agent, difference in echogenicity was observed between synthesized contrast agent and saline (p < 0.01). Conclusion: We could synthesize ultrasound contrast agents using an evaporation-drying-sonication method. On the basis of these results, many prospective types of research, such as anticancer drug delivery, gene delivery, including siRNA or microRNA, targeted molecular imaging, and targeted therapy can be performed.

Key Methodologies to Effective Site-specific Accessment in Contaminated Soils : A Review (오염토양의 효과적 현장조사에 대한 주요 방법론의 검토)

  • Chung, Doug-Young
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.32 no.4
    • /
    • pp.383-397
    • /
    • 1999
  • For sites to be investigated, the results of such an investigation can be used in determining foals for cleanup, quantifying risks, determining acceptable and unacceptable risk, and developing cleanup plans t hat do not cause unnecessary delays in the redevelopment and reuse of the property. To do this, it is essential that an appropriately detailed study of the site be performed to identify the cause, nature, and extent of contamination and the possible threats to the environment or to any people living or working nearby through the analysis of samples of soil and soil gas, groundwater, surface water, and sediment. The migration pathways of contaminants also are examined during this phase. Key aspects of cost-effective site assessment to help standardize and accelerate the evaluation of contaminated soils at sites are to provide a simple step-by-step methodology for environmental science/engineering professionals to calculate risk-based, site-specific soil levels for contaminants in soil. Its use may significantly reduce the time it takes to complete soil investigations and cleanup actions at some sites, as well as improve the consistency of these actions across the nation. To achieve the effective site assessment, it requires the criteria for choosing the type of standard and setting the magnitude of the standard come from different sources, depending on many factors including the nature of the contamination. A general scheme for site-specific assessment consists of sequential Phase I, II, and III, which is defined by workplan and soil screening levels. Phase I are conducted to identify and confirm a site's recognized environmental conditions resulting from past actions. If a Phase 1 identifies potential hazardous substances, a Phase II is usually conducted to confirm the absence, or presence and extent, of contamination. Phase II involve the collection and analysis of samples. And Phase III is to remediate the contaminated soils determined by Phase I and Phase II. However, important factors in determining whether a assessment standard is site-specific and suitable are (1) the spatial extent of the sampling and the size of the sample area; (2) the number of samples taken: (3) the strategy of taking samples: and (4) the way the data are analyzed. Although selected methods are recommended, application of quantitative methods is directed by users having prior training or experience for the dynamic site investigation process.

  • PDF

Analysis of CO2 Emission Pattern by Use in Residential Sector (가정 부문 이산화탄소 배출량 추이 분석)

  • Yoon, So Won;Lim, Eun Hyouk;Lee, Gyoung Mi;Hong, You Deok
    • Journal of Climate Change Research
    • /
    • v.1 no.3
    • /
    • pp.189-203
    • /
    • 2010
  • The objective of this study is the estimate of $CO_2$ emissions by the energy consumption of functional technology introduced by classifying energy use in households according to functions as well as energy resources. This study also intends to provide the practical basis data in order to establish specific alternatives for GHG mitigation in residential sector with examining the cause analysis affecting $CO_2$ emission increases from 1995 to 2007. The results of this study show a 6.6% increase in the total $CO_2$ from 60,636 thousand tons in 1995 to 64,611 thousand tons in 2007 by using energy in residential sector. Heating is the greatest $CO_2$ emission sector by use, followed electric appliances, cooking, lighting and cooling. Heating sector shows 56.6% reductions from 71.5% in 1995 and as do cooling and electric home appliances, with a 2.4% increase from 0.6% and a 21.8% increase from 14.2% respectively. To analyze factors resulted in $CO_2$ emissions in residential sector, the relevant indicator change rate from 2005 to 2007 was examined. The results find that population, the number of household, housing areas, family patterns, and family income resulted in the $CO_2$ emissions increase in residential sector from 1995 to 2007. On the other hand, carbon intensity and energy intensity contribute to $CO_2$ reduction in residential sector with -2% and -38.7% respectively because of the energy conversion and the improvement of energy efficiency in electronic appliances. This study can be used as a reference when taken account of the reality and considered the introduction of highly effective measures to increase the possibility of mitigation potential in residential sector hereafter.

Analysis of Climate Change Adaptation Researches Related to Health in South Korea (한국의 건강 분야 기후변화적응 연구동향 분석)

  • Ha, Jongsik
    • Journal of Climate Change Research
    • /
    • v.5 no.2
    • /
    • pp.139-151
    • /
    • 2014
  • It is increasingly supported by scientific evidence that greenhouse gas caused by human activities is changing the global climate. In particular, the changing climate has affected human health, directly or indirectly, and its adverse impacts are estimated to increase in the future. In response, many countries have established and implemented a variety of mitigation and adaptation measures. However, it is significant to note that climate change will continue over the next few centuries and its impacts on human health should be tackled urgently. The purpose of this paper is to examine domestic policies and research in health sector in adaptation to climate change. It further aims to recommend future research directions for enhanced response to climate change in public health sector, by reviewing a series of adaptation policies in the selected countries and taking into account the general features of health adaptation policies. In this regard, this study first evaluates the current adaptation policies in public health sector by examining the National Climate Change Adaptation Master Plan(2011~2015) and Comprehensive Plan for Environment and Health(2011~2020) and reviewing research to date of the government and relevant institutions. For the literature review, two information service systems are used: namely, the National Science and Technology Information Service(NTIS) and the Policy Research Information Service & Management(PRISM). Secondly, a series of foreign adaptation policies are selected based on the global research priorities set by WHO (2009) and reviewed in order to draw implications for domestic research. Finally, the barriers or constraints in establishing and implementing health adaptation policies are analyzed qualitatively, considering the general characteristics of adaptation in the health sector to climate change, which include uncertainty, finance, technology, institutions, and public awareness. This study provides four major recommendations: to mainstream health sector in the field of adaptation policy and research; to integrate cross-sectoral adaptation measures with an aim to the improvement of health and well-being of the society; to enhance the adaptation measures based on evidence and cost-effectiveness analysis; and to facilitate systemization in health adaptation through setting the key players and the agenda.

Assessment of CO2 Fertilization Captured in Thermoelectric Power Plant on Leafy Vegetables Grown in Greenhouse (화력발전소 포집 CO2를 이용한 시설 엽채류 시비효과 평가)

  • Jeong, Hyeon Woo;Hwang, Hee Sung;Park, Jeong;Yoon, Seong Ju;Hwang, Seung Jae
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.423-431
    • /
    • 2022
  • Due to increase of interest in 'carbon neutrality', attempts at agricultural use of CO2 are increasing. In this study, we used the dry-ice made by CO2 as by-product in thermoelectric power plant on CO2 fertilization for production of leafy vegetable in greenhouses. The dry-ice was supplied on three leafy vegetable farms (Allium tuberosum Rottl. ex Spreng, Aster scaber, and Oenanthe stolonifera DC.) located in Hadong, Gyeongsangnamdo. Two greenhouses were used in each leaf vegetable crops, one greenhouse used as the control (non-treatment), other greenhouse used as supplied CO2. For CO2 fertilization, a gas sublimated from dry ice was supplied to the greenhouse using a specially designed prototype supply machine. A. tuberosum greenhouse has no difference of CO2 concentration between the control, and CO2 fertilization and shown high CO2 concentration both greenhouses. However, the CO2 concentrations in A. scaber and O. stolonifera greenhouses were increased in CO2 fertilization treatment. The growth of A. scaber and O. stolonifera were increased in CO2 fertilization, and the yield also increased to 36% and 25% than the control, respectively. As a result of economic analysis, the A. scaber has increase of income rate, however A. tuberosum and O. stolonifera has decreased income rate. Thus, the use of the dry-ice made by CO2 as by-product in thermoelectric power plant has possibility to increase productivity of the leafy vegetable in greenhouse and have agricultural use value.

Monitoring of Residual Pesticides and Exposure Assessment of Olive Oil Products Sold on the Market (올리브유의 잔류농약 모니터링 및 노출량 조사)

  • Mi-Hui Son;Jae-Kwan Kim;You-Jin Lee;Ji-Eun Kim;Eun-Jin Baek;Byeong-Tae Kim;Seong-Nam Lee;Myoung-Ki Park;Yong-Bae Park
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.4
    • /
    • pp.211-216
    • /
    • 2023
  • A total of 100 commercially available olive oil products were analyzed for 179 pesticide residues using gas chromatography-tandem mass spectrometry (GC/MS/MS). The olive oil samples were mixed with organic solvents, centrifuged and frozen to remove fat, and pesticide residues were analyzed using the "quick, easy, cheap, effective, rugged, and safe" (QuEChERS) method. The determination coefficient (R2) of the analysis method used in this study was ≥0.998. The detection limit of the method ranged 0.004-0.006 mg/kg and its quantitative limit ranged 0.012-0.017 mg/kg. The recovery rate (n=5) measured at the level ranging 0.01-0.02, 0.1, and 0.5 mg/kg ranged 66.8-119.5%. The relative standard deviation (RSD) was determined to be ≤5.7%, confirming that this method was suitable for the "Guidelines for Standard Procedures for Preparing Food Test Methods". The results showed that a total of 151 pesticides (including difenoconazole, deltamethrin, oxyfluorfen, kresoxim-methyl, phosmet, pyrimethanil, tebuconazole, and trifloxystrobin) were detected in 64 of the 100 olive oil products. The detection range of these pesticide residues was 0.01-0.30 mg/kg. The percentage acceptable daily intake (%ADI) of the pesticides calculated using ADI and estimated daily intake (EDI) was 0.0001-0.1346, indicating that the detected pesticides were present at safe levels. This study provides basic data for securing the safety of olive oil products by monitoring pesticide residues in commercially available oilve oil products. Collectively, the analysis method used in this study can be used as a method to analyze residual pesticides in edible oils.

An educational needs analysis of precautions against of safety accidents for school foodservice employees in the Jeonbuk area using Borich priority formula and the Locus for Focus Model (Borich 요구도와 The Locus for Focus Model을 이용한 전북지역 학교급식 조리종사자의 안전사고 예방관리를 위한 교육요구도 우선순위 분석)

  • Hyang Jin Lee ;Sun A Choi ;Jeong Ok Rho
    • Journal of Nutrition and Health
    • /
    • v.56 no.5
    • /
    • pp.554-572
    • /
    • 2023
  • Purpose: The purpose of the study was to analyze the priorities for educational content regarding precautions to be taken to prevent safety accidents for employees in school foodservice using the Borich priority formula and the Locus for Focus model. Methods: A survey was conducted in February 2019 on 194 employees in elementary school and 122 employees in middle- and high school foodservice in the Jeonbuk area. Demographic characteristics, status of safety accidents, safety education, and their importance and performance levels were assessed using a self-administered questionnaire. The priorities for the educational content on precautions to prevent safety accidents were based on a 3-step analysis method, including the paired sample t-test, Borich priority formula, and the Locus for Focus Model. Results: The average perceived importance of the precautions to be taken against safety accidents of employees in elementary-, middle-, and high schools was higher compared to the average performance of the employees (p < 0.001). The top priority for elementary school employees was caution against falls during the cleaning of the gas hood and the trench in the kitchen. In addition, 'awareness of chemical signs' was added as one of the top priorities of middle- and high school employees. The second highest priority items were 'do stretching', 'safely adjusting workbench height', 'keeping the right attitude', 'using assistive devices when moving heavy things', and 'checking the material safety data sheet', which were the same for all elementary, middle- and high school employees. Conclusion: Thus, to improve the educational preparedness of employees in the area of safety precautions, eight safety/accident prevention items should be included in the safety education program.