• Title/Summary/Keyword: GAF

Search Result 41, Processing Time 0.043 seconds

Research on Friction Characteristics of Constant Velocity Joint Grease (등속조인트용 그리스 마찰특성 연구)

  • Lee, Sung Uk;Bae, Dae Yoon
    • Tribology and Lubricants
    • /
    • v.29 no.4
    • /
    • pp.223-227
    • /
    • 2013
  • A GAF (generated axial force) is produced at a plunging-type CVJ (constant velocity joint). A high GAF can cause vibrations in a vehicle. Grease is used to reduce friction between the roller and the track of the outer case of a CVJ. The grease performance depends on the surface conditions and operating temperature. The surface of the outer case is extremely rough and hard. In recent times, the maximum operating temperature of CVJs has crossed $140^{\circ}C$, because the exhaust line is now located close to the CVJ. In this study, we examined the friction characteristics of friction additives at $25-150^{\circ}C$ and determined an optimal formulation with a low friction coefficient. This formulation can be used to develop low-friction grease that can reduce the GAF produced at a CVJ by approximately 7-26%.

Feasibility Study of Dose Evaluation of Stereotactic Radiosurgery using GafChromic $EBT^{(R)}$ Film (GafChromic $EBT^{(R)}$ 필름을 이용한 뇌정위방사선치료의 선량분석 가능성 평가)

  • Jang, Eun-Sung;Lee, Chul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.27-33
    • /
    • 2007
  • Purpose: We have performed SRS (stereotactic radiosurgery) for avm (arterry vein malformation) and brain cancer. In order to verify dose and localization of SRS, dose distributions from TPS ($X-Knife^{(R)}$ 3.0, Radionics, USA) and GafChromic $EBT^{(R)}$ film in a head phantom were compared. Materials and Methods: In this study, head and neck region of conventional humanoid phantom was modified by substituting one of 2.5 cm slap with five 0.5 cm acrylic plates to stack the GafChromic $EBT^{(R)}$ film slice by slice with 5 mm intervals. Four films and five acrylic plates were cut along the contour of head phantom in axial plane. The head phantom was fixed with SRS head ring and adapted SRS localizer as same as real SRS procedure. CT images of the head phantom were acquired in 5 mm slice intervals as film interval. Five arc 6 MV photon beams using the SRS cone with 2 cm diameter were delivered 300 cGy to the target in the phantom. Ten small pieces of the film were exposed to 0, 50, 100, 200, 300, 400, 500, 600, 700, 800, 900 cGy, respectively to calibrate the GafChromic $EBT^{(R)}$ film. The films in the phantom were digitized after 24 hours and its linearity was calibrated. The pixel values of the film were converted to the dose and compared with the dose distribution from the TPS calculation. Results: Calibration curve for the GafChromic $EBT^{(R)}$ film was linear up to 900 cGy. The R2 value was better than 0.992. Discrepancy between calculated from $X-Knife^{(R)}$ 3.0 and measured dose distributions with the film was less than 5% through all slices. Conclusion: It was possible to evaluate every slice of humanoid phantom by stacking the GafChromic EBT film which is suitable for 2 dimensional dosimetry, It was found that film dosimetry using the GafChromic $EBT^{(R)}$ film is feasible for routine dosimetric QA of stereotactic radiosurgery.

  • PDF

Greedy Anycast Forwarding Protocol based on Vehicle Moving Direction and Distance (차량의 이동 방향과 거리 기반의 그리디 애니캐스트 포워딩 프로토콜)

  • Cha, Siho;Lee, Jongeon;Ryu, Minwoo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.1
    • /
    • pp.79-85
    • /
    • 2017
  • Vehicular ad-hoc networks (VANETs) cause link disconnection problems due to the rapid speed and the frequent moving direction change of vehicles. Link disconnection in vehicle-to-vehicle communication is an important issue that must be solved because it decreases the reliability of packet forwarding. From the characteristics of VANETs, greedy forwarding protocols using the position information based on the inter-vehicle distance have gained attention. However, greedy forwarding protocols do not perform well in the urban environment where the direction of the vehicle changes greatly. It is because greedy forwarding protocols select the neighbor vehicle that is closest to the destination vehicle as the next transmission vehicle. In this paper, we propose a greedy anycast forwarding (GAF) protocol to improve the reliability of the inter-vehicle communication. The proposed GAF protocol combines the greedy forwarding scheme and the anycast forwarding method. Simulation results show that the GAF protocol can provide a better packet delivery rate than existing greedy forwarding protocols.

Development of Preliminary Quality Assurance Software for $GafChromic^{(R)}$ EBT2 Film Dosimetry ($GafChromic^{(R)}$ EBT2 Film Dosimetry를 위한 품질 관리용 초기 프로그램 개발)

  • Park, Ji-Yeon;Lee, Jeong-Woo;Choi, Kyoung-Sik;Hong, Semie;Park, Byung-Moon;Bae, Yong-Ki;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.113-119
    • /
    • 2010
  • Software for GafChromic EBT2 film dosimetry was developed in this study. The software provides film calibration functions based on color channels, which are categorized depending on the colors red, green, blue, and gray. Evaluations of the correction effects for light scattering of a flat-bed scanner and thickness differences of the active layer are available. Dosimetric results from EBT2 films can be compared with those from the treatment planning system ECLIPSE or the two-dimensional ionization chamber array MatriXX. Dose verification using EBT2 films is implemented by carrying out the following procedures: file import, noise filtering, background correction and active layer correction, dose calculation, and evaluation. The relative and absolute background corrections are selectively applied. The calibration results and fitting equation for the sensitometric curve are exported to files. After two different types of dose matrixes are aligned through the interpolation of spatial pixel spacing, interactive translation, and rotation, profiles and isodose curves are compared. In addition, the gamma index and gamma histogram are analyzed according to the determined criteria of distance-to-agreement and dose difference. The performance evaluations were achieved by dose verification in the $60^{\circ}$-enhanced dynamic wedged field and intensity-modulated (IM) beams for prostate cancer. All pass ratios for the two types of tests showed more than 99% in the evaluation, and a gamma histogram with 3 mm and 3% criteria was used. The software was developed for use in routine periodic quality assurance and complex IM beam verification. It can also be used as a dedicated radiochromic film software tool for analyzing dose distribution.

Absorbed Dose for the Endovascular Ho-166-DTPA Brachytherapy Using a Balloon Angio Catheter (풍선도자관의 Ho-166-DTPA 흡수선량)

  • 조철우;박찬희;윤석남;강해준;김미화;장지선;박경배
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.98-103
    • /
    • 2002
  • The purpose of this study was to evaluate the absorbed dose to the coronary artery segment from various sized balloon angio catheters. The liquid form of Ho-166 was produced at the KAERI by (n, ${\gamma}$ ) reaction. We used GafChromic film for the estimation of the absorbed dose by beta particles. The exposed films were read using a videodensitometer. Several film exposures were made with varying irradiation times and activities. A modified micrometer was used for the measurement of the absorbed dose distribution near the balloon surface. Four balloons of coronary catheters evaluated were 30 m long and 2.5, 3.0, 3.5 and 4.0 mm in diameter. All doses are plotted in units of Gy/min/GBq/ml as a function of radial distance in mm from the surface of balloon. The absorbed dose rate was 0.86, 1.01, 1.11 and 1.24 Gy/min/GBq/ml at a balloon surface for various balloon diameter 2.5, 3.0, 3.5 and 4.0 mm respectively. Using a vacuum pump, the air in the balloon was evacuated prior to instillation of the Ho-166 source. By removing air bubbles in the balloon, the absorbed dose distribution was more uniform.

  • PDF

A Study on Biological Activities of Fermented Jujube and Grape (대추 및 포도 발효물의 생리활성 효과에 관한 연구)

  • Park, Tae-Soon;Kim, Dong-Hee;Kwon, O-Jun;Son, Jun-Ho
    • Microbiology and Biotechnology Letters
    • /
    • v.42 no.2
    • /
    • pp.106-113
    • /
    • 2014
  • For the development of high value consumables utilizing jujube and grape, we investigated the biological activities of a variety of existing fermentation products of jujube and grape. The results revealed that ethanol fermentation products of jujube and grape had a higher antioxidative activity than acetic acid fermentation products. In addition, the ethanol fermentation products of jujube (JEF) had the highest antioxidative activity, with it being greater than that of the ethanol fermentation products of grape (GEF), the acetic acid fermentation products of jujube (JAF) and the acetic acid fermentation products of grape (GAF). As regards tests on whitening effects, JEF exhibited the highest tyrosinase inhibition effects amongst the test groups. However, when immunofluorecence was employed, JAF was seen to inhibit the expression of proteins related to the whitening effect. In the lipopolysaccharide-stimulated mode peritoneal macrophage model, all tested groups of fermentation products (JEF, GEF, JAF and GAF) suppressed nitric oxide production dose-dependently, with ethanol fermentation products demonstrating a higher nitric oxide expression inhibition effect than acetic acid fermentation products. When subjected to antibacterial activity tests, GAF exhibited antibacterial activity against all tested strains except Propionibacterium acnes. Both GAF and JEF revealed high antibacterial activity against Escherichia coli.

A Study on the Characteristics of Vibration Due to the Forces of Drive Shaft (승용차량 구동축의 작용력에 따른 진동특성 연구)

  • Sa, Jongsung;Kang, Taewon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.4
    • /
    • pp.708-716
    • /
    • 2013
  • This study aims to understand the applied forces and related vibrational characteristics of a tripod joint (TJ), which is mostly used in front-drive-type middle-sized sedans in South Korea. The plunging force (PF) and generated axial force (GAF) are the most influential quantities related to the vibrational characteristics of a driveshaft. To obtain meaningful data, specially designed tests were performed using MTS test sets. The results of direct measurements reveal that higher PF and GAF values appear to worsen the vibrational characteristics of the vehicle. On the other hand, the measured apparent mass is useful for calculating the applied forces for a short driveshaft that has no dynamic vibration absorber. Among diversely controlled samples, it shows that the viscosity and tight fit are very sensitive to shudder vibrations of the vehicle. Therefore, these are good design factors for quality controls in the production line of constant-velocity joints.

Influences of mental health characteristics and admission experiences on perceived coercion (정신장애 특성과 입원과정의 경험들이 지각된 강요에 미치는 영향)

  • Seo, Mi Kyung;Kim, Seung-Hyun;Rhee, MinKyu;Choi, Yong-Sung;Kim, Sung-Hyun;Lee, Moon-Soo;Lee, Heon-Jeong;Kwon, Young-Joon;Kim, Bong-Jo
    • Korean Journal of Health Psychology
    • /
    • v.16 no.1
    • /
    • pp.1-14
    • /
    • 2011
  • Coercive treatment in mental health has undergone an immense period of philosophical and clinical debate and yet it remains as a highly important issue in which ideology and practice contradict each other. this study focused on the perceived coercion of the persons with mental disorder and analyzed how the characteristics of mental disorder(psychiatric symptoms, psycho-social functions, insight, and the degree of awareness on the need for treatment) and experiences in the process of hospitalization (legal status, coercive measures, and procedural justice) can predict perceived coercion. The participants of this study were 302 patients that has been hospitalized in the psychiatric ward within the period of 4 weeks. 195 participants(64.6%) were male and 106(35.1%) participants were female. MAES, BPRS, GAF, Insight, Legal Status, Coercive Measures, and Need for Treatment were measured. Regression analysis was used to analyze how much perceived coercion can be predicted by characteristics of mental disorder such as the patients' BPRS, GAF, insight, and need for treatment. As a result it showed that among the characteristics of mental disorder insight and awareness of the need for treatment were the main predictors and the characteristics of experiences during hospitalization such as procedural justice, coercive measures, and legal status all displayed significant predictability. As well as implications of results in a practical method of intervention to reduce perceived coercion, the paper discussed issues for limitations and future consideration.

Cognitive Abilities and Auditory Event Related Potentials in Patients with Schizophrenia (조현병 환자의 인지기능과 뇌 사건유발전위의 관계)

  • Kim, Ka-Young;Min, Jung-Ah;Chae, Jeong-Ho
    • Korean Journal of Biological Psychiatry
    • /
    • v.19 no.3
    • /
    • pp.115-120
    • /
    • 2012
  • Objectives : Event-related potentials have been suggested as an objective marker for brain functions in psychiatric disorders. This study was aimed to investigate the relationships between P300, the mismatch negativity (MMN), the loudness dependence of the auditory evoked potential (LDAEP), demographic and clinical variables including neurocognitive abilities in patients with schizophrenia. Methods : P300, the MMN, and the LDAEP were measured and the Korean Stroop color-word test (K-stroop test) and the Wisconsin Card Sorting Test (WCST) were performed in 43 patients with schizophrenia. The relationship of the latency and amplitude of P300 and the MMN as well as regression slope of the LDAEP with demographic and clinical variables were analyzed by t-test and correlation analyses for categorical and continuous variables, respectively. Results : After controlling for age, the latency of central (Cz) and parietal (Pz) P300 posivitively correlated with GAF at admission (Cz ; ${\gamma}$ = 0.385, p = 0.047, Pz ; ${\gamma}$ = 0.421, p = 0.029). The amplitude of parietal P300 correlated with the correction rate of the K-stroop test (${\gamma}$ = 0.575, p = 0.002). In addition, the frontal (Fz) P300 latency tended to negatively correlated with the correction rate of the WCST (${\gamma}$ = -0.371, p = 0.057). Conclusions : Our findings suggest that the values of P300 latency and amplitude might be correlated with GAF at admission and working memory measured by the K-Stroop test and the WCST. Meanwhile, the MMN and the LDAEP did not correlate with demographic and clinical variables. These results support the results of previous studies showing associations with P300 and impaired cognitive ability.

Absorbed Dose from Large Balloon Filled with Liquid Ho-166

  • Joh, Chul-Woo;Park, Chan H.;Lee, Myoung-Hoon;Yoon, Seok-Nam;Kim, Mi-Hwa;Jang, Ji-Sun;Park, Kyung-Bae
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.328-330
    • /
    • 2002
  • Large balloon angio catheter is used for Percutaneous Transluminal Angioplsty(TPA) of the iliac, femoral and renal arteries as well as after Transjugular Intrahepatic portosystemic shunt(TIPS). The use of angioplasty balloon filled with liquid form of radioisotope reduces the rate of restenosis after PTA. The purpose of this study was to evaluate the absorbed dose to the target vessels from various sized large balloon filled with liquid form of Ho-166-DTPA. Four balloons of balloon dilatation catheters evaluated were 5, 6, 8 and 10 mm in diameter. GafChromic film was used for the estimation of the absorbed dose near the surface of the balloon catheters. Absorbed dose rates are plotted in units of Gy/min/GBq/ml as a function of radial distance in mm from the surface of balloon. The absorbed dose rate was 1.1, 1.6, 2.2 and 2.3 Gy/min/GBq/ml at a balloon surface, 0.3, 0.4, 0.5 and 0.6 Gy/min/GBq/ml at 1 mm depth for various balloon diameter 5, 6, 8 and 10 mm in diameter respectively. The study was conducted to estimate the absorbed doses to the vessels from various sized large balloons filled with liquid form of Ho-166-DTPA for clinical trial of radiation therapy after the PTA. The absorbed dose distribution of Ho-166 appeared to be nearly ideal for vascular irradiation since beta range is very short avoiding unnecessary radiation to surrounding normal tissues.

  • PDF