• Title/Summary/Keyword: G-power

Search Result 4,958, Processing Time 0.03 seconds

Design of Power System Stability for Local Mode Using Eigen-Sensivity (지역모드 제동을 위한 고유치 감도와 PSS 설계)

  • Song, S.G.;Nam, H.K.;Shim, K.S.;Kim, Y.G.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.14-16
    • /
    • 2001
  • The Eigen-Sensitivity theory at full system is used to supplement drawback of the existing PSS gain tuning methods in this paper. Hessenberg method is used to linear analysis. This proposed method is successfully tested on KEPCO 2003 off-peak power system to improve local mode. The designed PSS at 2003 off-peak system is installed in 2003 peak system to improve robustness.

  • PDF

Development of EMTDC model for Seo-deagu SVC (서대구 SVC의 EMTDC 모델 개발)

  • Kim, D.H.;Son, K.M.;Lee, T.G.;Yoon, Y.B.;Lee, J.;Jang, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.217-219
    • /
    • 2000
  • Recently a static var compensator(SVC) is installed at Seo-deagu Substation. It is a power system controller using power electronics commonly called Flexible AC Transmission Systems(FACTS). This paper presents the characteristics and configuration of the Seo-deagu SVC. This paper discusses the modeling aspect of the Seo-deagu SVC systems. EMTDC simulation model of the Seo-deagu SVC is developed and verified.

  • PDF

A Study on the Knowledge Based Control Algorithm for Performance Improvement of the Automotive Suspension System (현가장치의 성능향상을 위한 지능형 제어로직에 관한 연구)

  • So, S.G.;Byun, G.S.
    • Journal of Power System Engineering
    • /
    • v.5 no.2
    • /
    • pp.87-92
    • /
    • 2001
  • Automotive suspension system is a mechanism for isolation of the vibration coming from the road inputs. Recently, the electronically controlled suspension systems which may improve ride and handling performance have been developed. Here, the continuously controlled semi-active suspension system is focused. As a mechanism to control damping forces continuously, a solenoid valve is used. The modeling for the solenoid valve is introduced briefly, a vehicle dynamics modeling is constructed, and then combined system model is completed. To design the efficient control algorithm for the semiactive suspension system the knowledge based fuzzy logic is applied and the technique how to apply the sky-hook theory to the fuzzy logic is developed. Finally, to confirm the improvement of performance the computer simulation is carried out.

  • PDF

Simulation of Phase Unbalance and Power Factor Correction System (비상용발전기의 상불평형 및 역율보상기 시뮬레이션)

  • Shin, B.C.;Song, E.H.;Jeong, C.Y.;Kan, Y.;Cho, J.G.;Rim, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.419-421
    • /
    • 1997
  • Three-phase system has many problems because of the unbalance load. So we propose two control algorithms using active power filter to dissolve these problems. One is three-leg inverter topology in which ac neutral line is connected directly to the midpoint of two series dc capacitors. The other is four-leg inverter topology in which ac neutral line is provided through a fourth leg. The three-phase unbalance is considered by connecting the load to one-phase. It is show that the proposed control algorithms give good performances.

  • PDF

The antioxidant and cytotoxic activities of Sonchus oleraceus L. extracts

  • Yin, Jie;Kwon, Gu-Joong;Wang, Myeong-Hyeon
    • Nutrition Research and Practice
    • /
    • v.1 no.3
    • /
    • pp.189-194
    • /
    • 2007
  • This study investigated in vitro antioxidant activity of Sonchus oleraceus L. by extraction solvent, which were examined by reducing power, hydroxyl radical-scavenging activity(HRSA) and 1, 1-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging assays. 70% MeOH extract had the greatest reducing power while EtOH extract had the greatest HRSA. The antioxidant activity of S. oleraceus extracts was concentration dependent and its $IC_{50}$ values ranged from 47.1 to $210.5\;{\mu}g/ml$ and $IC_{50}$ of 70% MeOH, boiling water and 70% EtOH extracts were 47.1, 52.7 and $56.5\;{\mu}g/ml$, respectively. 70% MeOH extract of S. oleraceus contained the greatest amount of both phenolic and flavonoid contents. The extracts tested had greater nitrite scavenging effects at lower pH conditions. The cytotoxic activity showed that EtOH extract had the best activity against the growth of stomach cancer cell. These results suggest that S. oleraceus extract could be used as a potential source of natural antioxidants.

Demonstration Analysis of 3kW Grid Connected PV System (3kW급 계통연계형 태양광발전시스템 실증연구)

  • Choi Y.O.;Piao Z.G.;Jeong S.B.;Cho G.B.;Baek H.L.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.558-560
    • /
    • 2006
  • Solar cell converts sunlight into the electricity that one of the most versatile forms of energy. It has been developed and applied on residental electric power system by urbanized countries as a alternative energy source to overcome energy problem after oil shock. This paper summarizes the results of these efforts by offering a snapshot of the configuration of photovoltaic in residential applications. The status of PV system components and inter-connection and safety equipment will be summarized. Hence this paper discusses only points that might be useful for application.

  • PDF

Performance Analysis of 3kW Grid-Connected PV System (3kW급 계통연계형 태양광발전시스템의 성능 비교분석)

  • So J.H.;Jung Y.S.;Yu G.J.;Lee K.O.;Choi J.Y.;Ahn H.S
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.707-710
    • /
    • 2003
  • 3kW grid-connected photovoltaic (PV) system and data acquisition system are constructed for performance analysis of PV system at field demonstration test center of Gwang-Ju in Korea. As climatic and irradiation conditions are varied, operation characteristics of the PV system are collected and analyzed in data acquisition system. From these results, the performances of PV system have simulated and evaluated using simulation tool in comparison with actual value of data acquisition system of field demonstration test center. Furthermore, performance of total PV system e.g. electric power and loss factor at the site are reviewed.

  • PDF

Analyses and Evaluation of Gird Connected PCU for PV System (태양광발전용 계통연계형 PCU의 성능특성 분석평가)

  • So J. H.;Jung Y. S.;Yu G. J.;Choi J. Y.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.65-68
    • /
    • 2003
  • 3kW grid-connected photovoltaic(PV) systems and data acquisition system are constructed for performance analysis of PV system at field demonstration test center of Gwang-Ju in Korea. As climatic and irradiation conditions are varied, operation characteristics of the PV system are collected and analyzed in data acquisition system. From these results, the performances of PV systems have simulated and evaluated using simulation tool In comparison with actual value of data acquisition system of field demonstration test center. Furthermore, performance of each PV system e.g. electric power and loss factor is reviewed.

  • PDF

Power Spectrum of 2 Phase Random Centered Distribution Modulation Scheme with Multi Zero Vector (멀티 영벡터를 갖는 2상 랜덤 중앙 분포 변조기법의 파워 스펙트럼)

  • Oh S. Y.;Kim J. G.;Lim Y. C.;Yang H. Y.;Jung Y. G.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.21-30
    • /
    • 2003
  • 본 연구에서는 변조지수 M이 큰 영역에서는 고조파 스펙트럼의 광대역화 효과가 저하되는 2상 랜덤 중앙 정렬 변조기법 (Random Centered Distribution PWM : RCD)기법의 문제점을 해결하고자 멀티 영벡터 2상 RCD (Multi Zero Vector RCD : MZRCD) 변조기법을 제안하였다. 제안된 2상 MZRCD기법은 변조지수 M=0.7을 기준으로 하여 M이 0.7보다 큰 영역에서는 영벡터를 V(111)로 선택하고, 0.7보다 작은 영역에서는 V(000)을 선택한다. 제안된 방법을 유도모터 구동시스템에 적용해 본 결과, M이 0.7이상인 영역에서도 모터의 전압/전류 및 소음 스펙트럼의 광대역화 특성이 종전의 방법에 비하여 우수함을 확인할 수 있었다.

  • PDF

Development of the Preventive Diagnostic Expert System of Gas in Oil for Power Transformer (변압기 예방진단을 위한 유중가스 전문가 시스템 구축 연구)

  • Choi, I.H.;Kweon, D.J.;Jung, G.J.;Sun, J.H.;Kim, C.G.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1019-1021
    • /
    • 1999
  • In this paper, we describe the design and appliance of the preventive diagnostic expert system of gas in oil for power transformer. This expert system is developed to use expert system development tool; Element Expert (NEURON DATA Inc.) Analysis is developed by four diagnose methods. In first, the standard of KEPCO is applied. It classifies the state of transformer by four level: Normal, warning, abnormal and danger. And the others are gas pattern methods, IEC code method, and Dornen & Roger Ratio method and applied later. These latter methods analyse the cause of result. Inference engine was designed with Element Expert. In last, we operate the system with sample data and we can obtain the correctly inferred result for the state of transformer.

  • PDF