• 제목/요약/키워드: G-power

검색결과 4,956건 처리시간 0.033초

단상 PV-배터리에너지저장시스템의 출력전류 오프셋 보상기법 (Offset Compensation Method of Output Current in Single Phase PV-Baterry Energy Storage System)

  • 주재연;서현욱;조영훈;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.130-131
    • /
    • 2013
  • In this paper, it suggests offset compensation method of output current in single phase PV-BES system which is connected with grid. The algorithm applied removes grid's frequency ingredient using a notch filter and it extracts only DC offset current. It can reduce problems as saturation of power transformer cause by DC current when it is indoctrinated to grid.

  • PDF

가스분석을 이용한 변압기의 이상진단 알고리즘 연구 (A Study of the Preventive Diagnostic Algorithm of Gas in Oil for Power Transformer)

  • 최인혁;권동진;정길조;유연표;선종호;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1903-1905
    • /
    • 2000
  • Power transformers have a tendency of ultra-high voltage capacity as power demand increases day after day KEPCO also will have plan to supply transmission power from 345KV to 765KV in the early of 2000. Therefore, the fault by insulation destruction gives rise to large area of power failure in huge capacity transformers. On-line predictive diagnostics is very important in power transformers because of economic loss and its spreading effect. This study presents the algorithm for transformer oil analysis used KEPCO code, IEC code, gas pattern method and Dornenburg & Roger Ratio method. We also describe the MMI display of expert system programmed by Element Expert Tool(Neuron Data Inc.).

  • PDF

파라미터를 이용한 배전계통 보호능력 평가 및 최적화 (Optimal protection by using Parametric Protection Ability Index)

  • 신재항;현승호;임성일;이승재;최인선;진보건
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.202-204
    • /
    • 2003
  • This paper suggests an optimal parameter setting method by use of parametric protectability index, as the objective function. In this paper, a gradient based optimization method is used under the assumption that the initial values of a parameter is in a convex set including the optimal value, which is verified by a plenty of simulation studies. The proposed method is applied to a sample distribution network to shows its effectiveness.

  • PDF

Design of a Microcontroller Based Electronic Load Controller for a Self Excited Induction Generator Supplying Single-Phase Loads

  • Gao, Sarsing;Murthy, S. S.;Bhuvaneswari, G.;Gayathri, M. Sree Lalitha
    • Journal of Power Electronics
    • /
    • 제10권4호
    • /
    • pp.444-449
    • /
    • 2010
  • The generation of electric power using self excited induction generation (SEIG) is a viable option in remote and rural areas where grid electricity is not available. The generated voltage and frequency of these machines, however, varies with varying loads. This characteristic can be resolved either by adjusting the values of the excitation capacitance or by controlling the prime mover speed. Further, in a single-point constant power application, where the machines deliver a fixed amount of power, the electronic load controller (ELC) can be used to switch-in or switch-out a dump load whenever the consumer load decreases or increases respectively. This paper presents a detailed analysis and the design of a microcontroller based SEIG -ELC system intended for stand-alone pico hydro power generation. The simulated performance of the controller is supplemented by experimental results.

UPS용 병렬공진형 직류링크인버터를 위한 제어방식에 관한 연구 (Control Strategy of Resonant DC Link Inverter for UPS)

  • 백주원;유동욱;민병권;류승표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.159-161
    • /
    • 1994
  • A new control technique which generates high-quality sinusoidal output voltage from a single-phase resonant do link inverter suitable for the UPS systems is presented. The inverter output voltage control system has the PID controller with a minor loop of the filter inductor current and tile feedforward controller. The proposed control scheme also solves resonant voltage overshoot without any additional switch or passive component, resulting in pulses with uniform amplitude and high efficiency. Experimental results in the case of linear and nonlinear loads are presented to confirm the usefulness of the Proposed control algorithms.

  • PDF

싸이리스터 제어 직렬 보상기에 의한 전력계통 안정화 효과 (Power System Stabilization Effect by Thyristor Controlled Series Compensator)

  • 손광명;조정현;한학근;박종근;이병하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.9-11
    • /
    • 1994
  • FACTS concept is the control of power flow and increase of the loading on existing lines to the thermal limuts. This paper focuses on the ability of the thyristor controlled series compensator (TCSC) to stabilize the disturbed power systems. The result shows the potential benefit of the TCSC in addition to the role of controlling the steady state power flow. In order to show the effectiveness of controlled series capacitor, power system dynamic model is augmented and the effect of the SC into the power system dynamics is included. As a control algorithm, Linear Optimal Control theory is applied.

  • PDF

새로운 ZVS 3-레벨 공진폴 인버터 (A Novel ZVS 3-Level Resonant Pole Inverter)

  • 백주원;조정구;유동욱;송두익;원충언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.360-364
    • /
    • 1995
  • A zero voltage switching (ZVS) three level resonant pole inverter is presented for high power GTO inverters. The concept of auxiliary resonant commutated pole(ARCP) for two level inverter is extended to the three level inverter. The proposed auxiliary commutation circuit consists of one resonant inductor and two bi-directional switches, which provides ZVS condition to the main devices without increasing device voltage or current stresses. The auxiliary device operates with zero current switching(ZCS) which enables use of the low cost thyristors. The proposed circuit can handle higher voltage and higher power(1-10MVA) comparing to the two level one. Operation and analysis of the proposed circuit are illustrated. Experimental results with 10 KW, 4 kHz prototype are presented to verify the principle of operation.

  • PDF

저전력 멀티미디어 재생 기법 (PoMP : Power conscious Multimedia Player)

  • Park, Jung-Wan;Won, You-Jip
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2003년도 봄 학술발표논문집 Vol.30 No.1 (C)
    • /
    • pp.253-255
    • /
    • 2003
  • Electricity is the prime commodity in mobile device, e.g. smart phone, PDA, MP3 player and etc. This strict restriction on power consumption requirement of the mobile device puts unique demand in designing hardware and software components of the device. In this paper, we address the issue of minimizing the power consumption in retrieving the continuous media data from the disk drive for real-time playback purpose. Different from the legacy text based data, real-time multimedia playback requires that the storage supplies the data block continuous fashion. This may put immense burden on the power scarce environment since the disk Is required to be active for the entire playback duration. We develop elaborate algorithm which carefully analyzes the power consumption profile of the disk drive and which establishes the data retrieval schedule for the given playback. It computes the amount of data blocks to read, the length of active and standby period. According to our simulation result, the ARM algorithm exhibits superior performance in continuous media retrieval from the aspect of power consumption to legacy playback scheme.

  • PDF

디지털 제어를 이용한 Interleaving CRM 플라이백 타입 DC-AC 인버터의 구현 (Implementation of interleaved Critical mode Flyback type DC-AC inverter using digital controller)

  • 김지태;이규찬;서갑수;현병철;배현수;조보형
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.13-14
    • /
    • 2010
  • 본 논문에서는 경계 모드(Critical Mode) 플라이백 타입의 DC-AC 인버터에 인터리빙을 적용한 디지털 제어를 제안한다. 연속모드(CCM)나 불연속모드(DCM)와 달리 경계 모드의 경우 주파수가 가변되기 때문에 인터리빙으로 구현하기는 상당히 까다로운 측면이 있다. 또한 아날로그 제어기로 구현에 한계를 지니기 때문에 보다 간편한 구현을 위해 디지털 제어IC을 이용하여 구현하는 방법에 대해 기술한다. 본문에서 200W급 플라이백 타입의 DC-AC 인버터에 경계모드 인터리빙을 방법을 적용한 후 실험으로 검증한다.

  • PDF

Development of a human reliability analysis (HRA) guide for qualitative analysis with emphasis on narratives and models for tasks in extreme conditions

  • Kirimoto, Yukihiro;Hirotsu, Yuko;Nonose, Kohei;Sasou, Kunihide
    • Nuclear Engineering and Technology
    • /
    • 제53권2호
    • /
    • pp.376-385
    • /
    • 2021
  • Probabilistic risk assessment (PRA) has improved its elemental technologies used for assessing external events since the Fukushima Daiichi Nuclear Power Station Accident in 2011. HRA needs to be improved for analyzing tasks performed under extreme conditions (e.g., different actors responding to external events or performing operations using portable mitigation equipment). To make these improvements, it is essential to understand plant-specific and scenario-specific conditions that affect human performance. The Nuclear Risk Research Center (NRRC) of the Central Research Institute of Electric Power Industry (CRIEPI) has developed an HRA guide that compiles qualitative analysis methods for collecting plant-specific and scenario-specific conditions that affect human performance into "narratives," reflecting the latest research trends, and models for analysis of tasks under extreme conditions.