Stability Analysis and Proposal of a Simple Form of a Fuzzy PID Controller

  • Lee, Byung-Kyul;Kim, In-Hwan;Kim, Jong-Hwa
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권8호
    • /
    • pp.1299-1312
    • /
    • 2004
  • This paper suggests the simple form of a fuzzy PID controller and describes the design principle, tracking performance, stability analysis and changes of parameters of a suggested fuzzy PID controller. A fuzzy PID controller is derived from the design procedure of fuzzy control. It is well known that a fuzzy PID controller has a simple structure of the conventional PID controller but posses its self-tuning control capability and the gains of a fuzzy PID controller become nonlinear functions of the inputs. Nonlinear calculation during fuzzification, defuzzification and the fuzzy inference require more time in computation. To increase the applicability of a fuzzy PID controller to digital computer, a simple form of a fuzzy PID controller is introduced by the backward difference mapping and the analysis of the fuzzy input space. To guarantee the BIBO stability of a suggested fuzzy PID controller, ‘small gain theorem’ which proves the BIBO stability of a fuzzy PI and a fuzzy PD controller is used. After a detailed stability analysis using ‘small gain theorem’, from which a simple and practical method to decide the parameters of a fuzzy PID controller is derived. Through the computer simulations for the linear and nonlinear plants, the performance of a suggested fuzzy PID controller will be assured and the variation of the gains of a fuzzy PID controller will be investigated.

고정 파라미터를 갖는 단순화된 퍼지 PID 제어기의 제안과 안정도 분석 (Stability Analysis and Proposal of the Simplified Form of a Fuzzy PID Controller with Fixed Parameters)

  • 이병결;김인환;김종화
    • 한국지능시스템학회논문지
    • /
    • 제14권7호
    • /
    • pp.807-815
    • /
    • 2004
  • 본 논문은 고정 파라미터를 갖는 퍼지 PID제어기의 설계방법을 기술하고 컴퓨터 연산 시간을 줄일 수 있는 단순화된 퍼지 PID제어기를 제안하며 제안한 제어기의 안정도를 분석한다. 안정도 분석을 위해 사용한 소이득 정리로부터 전체 피드백 시스템의 BIBO 안정도의 실제적인 충분조건을 유도하고, 유도한 안정 조건으로부터 안정한 선형 PID제어기의 파라미터로부터 퍼지 PID제어기의 파라미터를 결정하는 방법을 고찰한다. 마지막으로 선형 시스템과 비선형 시스템에 대한 컴퓨터 시뮬레이션을 실시하고 비선형 퍼지 PID제어기의 시뮬레이션 결과를 선형 PID제어기의 시뮬레이션 결과와 비교하여 성능을 확인한다.

Simple Fuzzy PID Controllers for DC-DC Converters

  • Seo, K.W.;Choi, Han-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.724-729
    • /
    • 2012
  • A fuzzy PID controller design method is proposed for precise robust control of DC-DC buck converters. The PID parameters are determined reflecting on the common control engineering knowledge that transient performances can be improved if the P and I gains are big and the D gain is small at the beginning. Different from the previous fuzzy control design methods, the proposed method requires no defuzzification module and the global stability of the proposed fuzzy control system can be guaranteed. The proposed fuzzy PID controller is implemented by using a low-cost 8-bit microcontroller, and simulation and experimental results are given to demonstrate the effectiveness of the proposed method.

자연 순환식보일러의 퍼지제어 모사기 개발에 관한 연구 (A Study on Fuzzy Control Simulator of Naturally Circulated Boiler)

  • 김광선;김삼운
    • 대한기계학회논문집B
    • /
    • 제24권4호
    • /
    • pp.543-554
    • /
    • 2000
  • The engineering equations, which have been used in many engineering companies, were employed for the dynamic modelling part in order to develop the naturally circulated boiler simulator. The fuzzy algorithm, which is similar to the algorithm of making decision by the human being, was developed for the boiler simulator controller and its simulated variables were compared with those of classical PID simulations to verify the stability and the effectiveness of fuzzy controller. The simulator is for the naturally circulated boiler and the main components are the furnace, the drum, the super heater, and the economizer. The combustion and thermal radiation dominant equations were used within the furnace and the mass conservation and the energy rate balance equations were employed for the drum part. The heat transfer rates were calculated using the logarithmic mean temperature differences both for the super heater and for the economizer. The simulations are very useful to understand the boiler operations and the engineering design of the main components. The main program was developed under the PC window condition by linking the fuzzy controller to the main boiler program using the Visual C++ language. The various operational conditions such as the abrupt changes of load, the changes of water supply pipes and the diameter of drum were simulated.

Circle Criterion을 이용한 FLC의 안정도에 대한 고찰 (Consideration to the Stability of FLC using The Circle Criterion)

  • 이경웅;최한수
    • 제어로봇시스템학회논문지
    • /
    • 제15권5호
    • /
    • pp.525-529
    • /
    • 2009
  • Most of FLC received input data from error e and change-of-error e' with no relation with system complexity. Basic scheme follows typical PD and PI or PID Controller and that has been developed through fixed ME In this paper, We studied the relationship between MF and system response and system response through changing Fuzzy variable of consequence MF and propose the simple FLC using this relationship. The response of FLC is changed according to the width of Fuzzy variable of consequence MF. As changing the Fuzzy variable of consequence MF shows various nonlinear characteristic, we studied the relation between response and MF using analytical method. We designed the effective FLC using three-variable MF and nine rules and took simulation for verification. In this study, we propose the method to design system with FLC in stability point which is an impotent characteristic of designing system. The circle criterion which is adapted to analysis the nonlinear system is put to use for proposed method. Since SISO FLC has a time-invariant and odd characteristic we can use the critical point not disk which is generally used to determine the stability in the circle criterion, to determine the stability. Using this, we can get the maximum critical point plot of SISO FLC with changing the consequence fuzzy variables. The predetermined critical point plot of FLC can be used to decide the region of the system to be stable. This method is effectively used to design the SISO FLC.