• 제목/요약/키워드: Fuzzy Diagnosis System

검색결과 228건 처리시간 0.028초

스왐기반 퍼지시스템을 이용한 코크오븐 연소제어 모델링 (A combustion control modeling of coke oven by Swarm-based fuzzy system)

  • 고언태;황석균;이진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.493-495
    • /
    • 2005
  • This paper proposes a swarm-based fuzzy system modeling technique for coke oven combustion control diagnosis. The coke plant produces coke for the blast furnace plant in steel making process by charging coal into oven and supplying gas to carbonize it. A conventional mathematical model for coke oven combustion control has been used to control the amount of gas input, but it does not work well because of highly nonlinear feature of coke plant. To solve this problem, swarm-based fuzzy system modeling technique is suggested to construct a diagnosis model of coke oven combustion control. Based on the measured input-output data pairs, the fuzzy rules are generated and the parameters are tuned by the PSO(Particle Swarm Optimizer) to increase the accuracy of the fuzzy system is operated. This system computes the proper amount of gas input taking the operation conditions of coke oven into account, and compares the computed result with the supplied gas input.

  • PDF

가능성 이론을 이용한 전력계통 고장진단 (Power System Fault Diagnosis using Possibility Theory)

  • 이흥재;이철균;박등용;김성희;안복신
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권6호
    • /
    • pp.665-670
    • /
    • 1999
  • This paper introduces a fuzzy expert systems for fault diagnosis, where the causal relationships between faults and protective devices are defined as fuzzy relations. The uncertainties existing in the fault diagnosis are figured out using the possibility theory and the possibility measure is associated with the fuzzy relation to evaluate the possibilities of faults. Besides, the knowledge base in the expert system is described and explained. In this way, multiple-fault can be handled easily and simultaneously together with single faults.

  • PDF

저압 배선 이상 진단을 위한 지능형 차단 시스템 구축 (Development Intelligent Diagnosis System for Detecting Fault of Transmission Line)

  • 성화창;박진배;주영훈
    • 한국지능시스템학회논문지
    • /
    • 제18권4호
    • /
    • pp.518-523
    • /
    • 2008
  • 본 논문에서는 저압 배선 진단 시스템 개발에서 핵심 파트 중 하나인 지능형 차단 시스템 구축을 목표로 한다. 제안된 진단 시스템은 TFDR (Time-Frequency Domain Reflectometry) 알고리즘을 바탕으로 하여 실제 전압이 흐르는 배선에 대해 이상 거리 측정을 하게 된다. 그리고 배선으로부터 얻은 정보를 바탕으로 배선 이상의 종류를 분석하는 것이 지능형 차단 시스템의 목표이다. 효율적인 분석을 위해, 본 논문에서는 퍼지-베이시안 (Fuzzy-Bayesian) 알고리즘을 바탕으로 하여 시스템을 구성하였다. 실제 저압 배선에서 실험된 데이터를 바탕으로 한 실험을 통해 제안된 기술의 우수성을 입증하고자 한다.

Fuzzy 알고리즘을 이용한 엘리베이터 안전진단 및 동특성 분석 포터블 장비 개발 (A study on the Development of the Portable Device for Safety Diagnosis and Dynamic Characteristics Analysis of Elevator using Fuzzy Algorithm)

  • 김태형;김훈모
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.199-202
    • /
    • 2001
  • An elevator system, which is essential equipment for vertical movement of an object, as a property of building, has been driven by various expenditures and purposes. Since developing electrical control technology, control system are highly developed. The elevator system has expanded widely, but a data accuracy acquisition technique and safety predict technique for securing system safety is still at a basic level. So, objective verification for elevator confidence condition requires an absolute accuracy measurement technique. Therefore, this study is executed in order to acquire a method of depending on sense of a manager with simple numeric measurement data, and to construct a logical, analytical foresight system for more efficient elevator management system. As an artificial intelligence for diagnosis, the fuzzy inference algorithm is used for foreseeing the system in this thesis, because the fuzzy algorithm is the most useful method for resolving subjective ideas and a vague judgment of humans. The fuzzy inference algorithm is developed for each sensor signal(i.e. vibration, velocity, current).

  • PDF

퍼지 패턴 분류와 뉴럴 네트워크를 이용한 지능형 유중가스 판정 시스템 (Intelligent Diagnosis System for DGA Using Fuzzy Pattern Classification and Neural Network)

  • 조성민;권동진;남창현;김재철
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2084-2090
    • /
    • 2007
  • The DGA (Dissolved Gases Analysis) technique has been widely using for fault diagnosis of the power transformers. Some electric power utility company establishes the criteria of DGA to improve reliability, because of difference of operation environment and design of power transformer. In this paper, we introduce intelligent diagnosis system for DGA result of KEPCO (Korea Electric Power Cooperation). This system can classify patterns type of gases ratio that frequently occurs in recent result of gases analysis using Fuzzy Inference. The classification of Patterns let us know that major causes of gases generation based on type of patterns. Finally, Neural Network based on patterns diagnose transformer. NN was trained using result data of DGA of actually faulted transformers recently. Result of intelligent diagnosis system is right well in comparison with actual inner inspection of transformers.

페푸프 제어 시스템을 위한 퍼지-신경망 기방 고장 진단 시스템의 개발 (Development of Neuro-Fuzzy-Based Fault Diagnostic System for Closed-Loop Control system)

  • 김성호;이성룡;강정규
    • 제어로봇시스템학회논문지
    • /
    • 제7권6호
    • /
    • pp.494-501
    • /
    • 2001
  • In this paper an ANFIS(Adativo Neuro-Fuzzy Inference System)- based fault detection and diagnosis for a closed loop control system is proposed. The proposed diagnostic system contains two ANFIS. One is run as a parallel model within the model in closed loop control(MCL) and the other is run as a series-parallel model within the process in closed loop(PCL) for the generation of relevant symptoms for fault diagnosis. These symptoms are further processed by another classification logic with simple rules and neural network for process and controller fault diagnosis. Experimental results for a DC shunt motor control system illustrate the effectiveness of the proposed diagnostic scheme.

  • PDF

Development of Insulation Degradation Diagnosis System for Electrical Plant

  • Kim, Yi-Gon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제2권1호
    • /
    • pp.33-37
    • /
    • 2002
  • Insulation aging diagnosis system provides early warning regarding electrical equipment defects. Early warning is very important in that it can avoid great losses resulting from unexpected shutdown of the production line. Since relations of insulation aging and partial discharge dynamics are non-linear. it is very difficult to provide early warning in an electrical equipment. In this paper, we propose the design method of insulation aging diagnosis system that use a electromagnetic wave and acoustic signal to diagnose an electrical equipment. Proposed system measures the partial discharge on-line from DAS(Data Acquisition System and acquires 2D patterns from analyzing it. For filtering the noise contained in sensor signals we used ICA algorithms. Using this data, we design of the neuro-fuzzy model that diagnoses an electrical equipment and is investigated in this paper. Validity of the new method is asserted by numerical simulation.

Bearing Fault Diagnosis Using Fuzzy Inference Optimized by Neural Network and Genetic Algorithm

  • Lee, Hong-Hee;Nguyen, Ngoc-Tu;Kwon, Jeong-Min
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.353-357
    • /
    • 2007
  • The bearing diagnostics method is presented in this paper using fuzzy inference based on vibration data. Both time-domain and frequency-domain features are used as input data for bearing fault detection. The Adaptive Network based Fuzzy Inference System (ANFIS) and Genetic Algorithm (GA) have been proposed to select the fuzzy model input and output parameters. Training results give the optimized fuzzy inference system for bearing diagnosis based on measured vibration data. The result is also tested with other sets of bearing data to illustrate the reliability of the chosen model.

퍼지 전문가 시스템을 이용한 유리 용해로 이상 감시 시스템 구축 사례 (A Fault Diagnosis System of Glass Melting furnace Using A Fuzzy Export System)

  • 문운철
    • 지능정보연구
    • /
    • 제8권1호
    • /
    • pp.63-74
    • /
    • 2002
  • 본 논문에서는 용해로 이상감시를 위한 실시간 유리 용해로 운전 전문가시스템을 구축한 결과를 소개한다. 유리용해 공정에서는 운전자의 경험지식에 의해 내부의 상황을 판단하게 되고, 이는 용해로 수명과 제품의 품질에 중요한 영향을 준다 이를 전문가 시스템으로 구현하기 위하여, 먼저 기존 운전자의 지식을 취합, 분석한다. 그 후, 취합된 각 지식들의 특성에 부합하도록 이진 규칙(Crisp Rule)과 퍼지 규칙(Fuzzy Rule)으로 구분한다. 이 때, 선형 회귀분석을 통하여 퍼지 규칙의 입력을 결정함으로써 보다 정확한 운전 지식의 표현이 가능하도록 하였다. 설계된 알고리즘은 젠심(Gensym)사의 실시간 전문가 시스템 개발 툴인 G2를 사용하여 구현하였다. 제시된 퍼지 전문가 시스템은 삼성코닝(주) 수원사업장의 실제 생산 용해 공정에 직접 적용하여 그 효율성이 검증되었다.

  • PDF

Fuzzy-Bayes Fault Isolator Design for BLDC Motor Fault Diagnosis

  • Suh, Suhk-Hoon
    • International Journal of Control, Automation, and Systems
    • /
    • 제2권3호
    • /
    • pp.354-361
    • /
    • 2004
  • To improve fault isolation performance of the Bayes isolator, this paper proposes the Fuzzy-Bayes isolator, which uses the Fuzzy-Bayes classifier as a fault isolator. The Fuzzy-Bayes classifier is composed of the Bayes classifier and weighting factor, which is determined by fuzzy inference logic. The Mahalanobis distance derivative is mapped to the weighting factor by fuzzy inference logic. The Fuzzy-Bayes fault isolator is designed for the BLDC motor fault diagnosis system. Fault isolation performance is evaluated by the experiments. The research results indicate that the Fuzzy-Bayes fault isolator improves fault isolation performance and that it can reduce the transition region chattering that is occurred when the fault is injected. In the experiment, chattering is reduced by about half that of the Bayes classifier's.