• Title/Summary/Keyword: Fusion device

Search Result 294, Processing Time 0.025 seconds

Estimation of Stroke Volume Based on Air Pressure in Air Tube with Pneumatic Pulsatile Ventricular Assist Device (공압식 박동형 심실보조장치에서 공압관 내 공기압에 따른 박출량 추정)

  • Kang, Yu Min;Lee, Jin Hong;Her, Keun;Choi, Seong Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.12
    • /
    • pp.971-974
    • /
    • 2014
  • A ventricular assist device (VAD) is used for bridge to heart transplantation and heart diseases. Knowing the status of a pneumatic pulsatile VAD when implanting it into the body is important: when the velocity of blood flow through the VAD is slow, a thrombus may occur, and thrombosis can be fatal to a patient. In order to determine the state of a VAD, various sensors need to be implanted. Because this introduces the risk of infection and difficulties with sensor management, we developed a method for estimating the state of a VAD indirectly via the pressure in an air tube that can be measured in vitro. We compared the measured values to in vitro experimental results. The estimated and measured values showed some errors, but the accuracy can be improved by refining the estimation process to minimize the risk of infection.

A Cyber-Physical Information System for Smart Buildings with Collaborative Information Fusion

  • Liu, Qing;Li, Lanlan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.5
    • /
    • pp.1516-1539
    • /
    • 2022
  • This article shows a set of physical information fusion IoT systems that we designed for smart buildings. Its essence is a computer system that combines physical quantities in buildings with quantitative analysis and control. In the part of the Internet of Things, its mechanism is controlled by a monitoring system based on sensor networks and computer-based algorithms. Based on the design idea of the agent, we have realized human-machine interaction (HMI) and machine-machine interaction (MMI). Among them, HMI is realized through human-machine interaction, while MMI is realized through embedded computing, sensors, controllers, and execution. Device and wireless communication network. This article mainly focuses on the function of wireless sensor networks and MMI in environmental monitoring. This function plays a fundamental role in building security, environmental control, HVAC, and other smart building control systems. The article not only discusses various network applications and their implementation based on agent design but also demonstrates our collaborative information fusion strategy. This strategy can provide a stable incentive method for the system through collaborative information fusion when the sensor system is unstable in the physical measurements, thereby preventing system jitter and unstable response caused by uncertain disturbances and environmental factors. This article also gives the results of the system test. The results show that through the CPS interaction of HMI and MMI, the intelligent building IoT system can achieve comprehensive monitoring, thereby providing support and expansion for advanced automation management.

A study on Evaluation Methods for Safety and Performance of Electrical Stimulations for Home Use (개인용전기자극기 성능 및 안전성 평가 방법 연구)

  • Kim, San;Jang, Moo-Young;Hwang, Yoon Su;Lee, Ki-Hun;Hur, Chan-Hoi;Hong, Choongman
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.3
    • /
    • pp.187-202
    • /
    • 2013
  • The electronic medical device industry and the relevant market have been greatly expanded owing to various factors, such as the advent of the aged society and the spread of the desire for well-being in developed countries, and rapid development of China, India and other emerging markets. The electrical stimulator is one of electronic medical devices most commonly used in homes. The electrical stimulator is widely used for pain relief, rehabilitation, muscle conditioning and others. Since it is mainly used in homes, it is very important to assure the safety and performance for protection of users. However, there is no guideline on evaluation of safety and performance of such electrical stimulator for home use. In this study, various local and foreign references were reviewed to develop the internationally harmonized procedures for safety and performance evaluation of the electrical stimulator and test items, specifications and methods are proposed. In addition, such proposed test items were validated to decide the internationally harmonized tests for safety and performance evaluation. This study will contribute to improvement of quality and safety of electrical stimulators for home use and help the Korean medical device industry have the international competitiveness.

A HMD VR data transmission solution by using strip LED attached Window Signage

  • Kim, Seung-Kyun;Woo, Deok-Gun;Park, Young-Ki;Im, Sang-Il;Timur, Khudaybergenov;Ku, Kyung-Hwan;Cha, Jae-Sang
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.4
    • /
    • pp.11-17
    • /
    • 2020
  • This paper proposed the design of a new window signage system architecture, which utilized a window of a building, with attached LED for visible light communication. In this paper, the proposed method using the LED strip to transmit light data and receive the data through a HMD with a smart device camera. The LED strip attached to the existing building window, as a part of semi-transparent signage. Semi-transparent signage based on a controllable LED strip-modules and attached to the window used to provide entertainment contents and the information service to people through optical camera communication (OCC) as well. Also, this work suggests using the camera supplied Head Mounted Device (HMD) as an OCC receiver. The LED attached window signage system structure described in this paper can be utilized in various buildings infrastructure like house, shopping areas, industrial building, etc.

Fabrication and Characterization of Hydrogen Getter Based on Palladium Oxide Doped Nanoporous SiO2/Si Substrate (PdOx가 도핑된 나노 기공구조 SiO2/Si 기반의 수소 게터 제작 및 특성평가)

  • Eom, Nu Si A;Lim, Hyo Ryoung;Choi, Yo-Min;Jeong, Young-Hun;Cho, Jeong-Ho;Choa, Yong-Ho
    • Korean Journal of Materials Research
    • /
    • v.24 no.11
    • /
    • pp.573-577
    • /
    • 2014
  • The existing metal getters are invariably covered with thin oxide layers in air and the native oxide layer must be dissolved into the getter materials for activation. However, high temperature is needed for the activation, which leads to unavoidable deleterious effects on the devices. Therefore, to improve the device efficiency and gas-adsorption properties of the device, it is essential to synthesize the getter with a method that does not require a thermal activation temperature. In this study, getter material was synthesized using palladium oxide (PdOx) which can adsorb $H_2$ gas. To enhance the efficiency of the hydrogen and moisture absorption, a porous layer with a large specific area was fabricated by an etching process and used as supporting substrates. It was confirmed that the moisture-absorption performance of the $SiO_2/Si$ was characterized by water vapor volume with relative humidity. The gas-adsorption properties occurred in the absence of the activation process.

PCB Instrumentation with Lubboe Bone in Anterior Cervical Interbody Fusion (PCB 기구와 이종골을 이용한 경추체간 전방 유합술)

  • Park, Jeong Hyun;Oh, Seong Hoon;Yi, Hyeong Joong;Kim, Ju Heon;Kim, Young Soo;Ko, Yong;Kim, Kwang Myung;Oh, Suck Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.11
    • /
    • pp.1284-1290
    • /
    • 2001
  • Objective : PCB cervical instrument is a newly introduced fusion device which comprises cervical plate, cage (spacer) and screw system. It is developed to enhance fusion rate and stability, as well as to reduce complications related to hardware failure. We investigated the efficacy of clinical and radiological results of PCB instrument and Lubboc bone. Methods : From August, 1998 to October, 1999, authors performed 54 cases of anterior cervical interbody fusion with PCB instrument and Lubboc bone. Retrospective analysis was undertaken based on clinical and radiological findings. Clinical improvement was evaluated according to Odom's criteria. Cervical plain films and tomography were taken every 2 months to evaluate the degree of interbody fusion and disc height changes. Results : Bone fusion was observed in 36 cases(90%) over 6 months after operation, and during which time there was no significant interval change. There were 3 cases of hardware dislodgement. Disc height was increased significantly and preserved in all cases. Clinical outcome over good degree was seen more than 94% of patients. Conclusion : Longer follow-up period and comparative studies to similar instrument appear to be necessary, but this instrumentation system has shown high fusion rate and fewer adverse effects in our series. We believe this system might be indicated for the treatment of cervical trauma and degenerative disease in selective cases.

  • PDF

Transdermal Permeation Behavior of 5-FU using Microneedle (마이크로니들을 이용한 5-FU의 경피투과 거동)

  • Kim, Myoung-Jin;Park, Jung-Soo;Kim, Yun-Tae;Lee, Jun-Hee;Ahn, Sik-Il;Park, Jong-Hak;Mo, Jong-Hyun;Lee, Tae-Wan;Lee, Han-Koo;Khang, Gil-Son;Lee, Hai-Bang
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.1
    • /
    • pp.45-50
    • /
    • 2008
  • 5-Fluorouracil (5-FU) is an antimetabolic of the pyrimidine derivatives that is used in chemotherapy for the treatment of several types of cancer. 5-FU have poor oral absorption and short biological half-time and strong side effects. Microneedle introduced to find a solution of problems. Microneedle device with roll was manufactured for transdermal delivery of various drugs. 5-FU was mixed in non-ionic surfactant such as tween 20 and tween 80. Camscope was used to analysis the permeation magnitude of treated skin by microneedle and trypan blue staining. The 5-FU solution with surfactant measured by ZETA-potential analysis system for stability of solution. The skin permeation rate of 5-FU determined by HPLC. We confirmed that cross treated skin was dyed more deeply than parallel treated skin through trypan blue staining. The results indicate that skin permeation rate of 5-FU was increased with the treatment types and treatment times.

Assembly and electrical property of GFP/Cytochrome b562 Fusion Protein ontothe Au Substrate

  • Jeong, Seong-Cheol;Choe, Jeong-U;Lee, Won-Hong;Nagamune, T.
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.630-633
    • /
    • 2003
  • Transfer of an electron from one site to another in a molecular or between molecules and/or electrodes is one of the most fundamental and ubiquitous processes in chemistry, biology and physics. In this study fusion proteins composed by green fluorescent protein(GFP) and cytochrome b562 were used in fabricating molecular array as an electron sensitizer and electron acceptor, Protein formation onto the substrate was performed by the self-assembly technique. The fusion protein film were analyzed using scanning probe microscope(SPM), Surface Plasmon Resornance(SPR) and hybrid STM/I-V. The results suggest that the proposed molecular photodiode can be used as a basic unit of the memory device.

  • PDF

ARCHITECTURE OF PERSONAL MOBILE NAVIGATION SYSTEM

  • Kim, Jae-Chul;Kim, Ju-Wan;Park, Jong-Hyun
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.713-716
    • /
    • 2006
  • The technique of the information communication are advanced recently and a performance enhance of a hand carried computing device was developed rapidly. Mobile Communication Carrier developed currently the phone navigation and are carrying out the service. But such service localizes at the vehicle movement. In This paper, we explain a system structure for the pedestrian navigation of the Wireless Internet Platform for Interoperability(WIPI) mobile phone which contains the MS-Based Global Positioning System(GPS) internally. And we verified the result to be developed by this method that proposes.

  • PDF

Effect of the Electric Field on the Plant Protoplasts During Cell Fusion (세포융합시 전계하에서 식물세포가 받는 영향에 관한연구)

  • Lee, Sang-Hoon;Lee, Yon-Min;Cha, Hyeon-Cheol
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.173-178
    • /
    • 1996
  • The objective of this paper is to investigate the effect of AC field on the protoplast of plant cells. The results of investigation will be the basis for the development of etectric cell fusion device. For the experiment, we made the electrode and AC and DC pulse generator and observed the behavior of the protoplasts through the inverted microscope which is connected to the monitor and video recorder by the CCD camera. As a result, the numbers of rotating, moving and destructed protoplasts and viability of the protoplasts have close relation to the amplitude of AC field, while the rotation rate is closely related to the frequency of AC pulse.

  • PDF