• 제목/요약/키워드: Fusion device

검색결과 294건 처리시간 0.039초

구형 집속 빔 핵융합 장치의 방전특성 연구 (A Study on Discharge Characteristics of Spherically Convergent Beam Fusion Device)

  • 박정호;주흥진;김봉석;고광철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1823-1825
    • /
    • 2004
  • Spherically convergent beam fusion device accelerate ions, which are generated between outer anode and inner grid cathode, toward the spherical center. The collision of opposite direction ions give rise to fusion reactions. Spherically convergent beam fusion device is very simple and compact, therefore the device has a potential that is applied to a portable neutron source. An experimental device consist of a 20cm-diameter spherical mesh-type anode and 7cm-diameter open spherical grid cathode and was maintained at a constant pressure of about 1333 Pa by feeding argon gas.

  • PDF

척추용 퓨전 디바이스의 개발 및 3차원 유한요소법을 이용한 역학적 해석 (Development of a Vertebral Fusion Device and Its Mechanical Analysis using 3-D Finite Element Method)

  • 김현수;전병찬;손한철;최경호;박정호;최태원
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권5호
    • /
    • pp.385-390
    • /
    • 2002
  • 오늘날 의료기기의 국산화 연구가 활발히 진행되고 있는 가운데 본 연구에서는 적추용 fusion device를 새롭게 개발하고자 시도하였다. 일반적으로 사용되고 있는 삽입형과 나사형을 기본 대상으로 하되 수술 시 뼈를 보다 적게 제거하여 삽입할 수 있게 하는 데 .) 주안점을 두고 형상 개발을 시도하였다. 아직 그 실효성을 논하기는 어려우나 고안된 척추용 fusion device의 형상을 중심으로 소개하고자 한다. 본 연구에서 경첩형과 분리삽입형을 고안하게 되었다. 그러나 경첩형은 기존 형상의 절반 크기로 삽입되는 장점은 있으나 핀의 강도해석과 안정된 잠금 장치의 개발에 더 연구가 요구되어 일단 본 연구에서는 분리삽입형을 중심으로 시제품과 3차인 유한요소 모델을 제작하여 그 역학적 해석을 행하였다. 그 결과 척추에 작용하는 기본 하중에 대한 역학적 안전성은 인정되나 아직 실용화되기까지는 보조 수술장비의 개발이 필요하다고 사료된다.

High Power ICRF Experiments in the Large Helical Device

  • Kasahara, H.;Saito, K.;Seki, T.;Kumazawa, R.;Kubo, S.;Shimozuma, T.;Yoshimura, Y.;Igami, H.;Takahashi, Y.;Nakamura, Y.;Shimpo, F.;Nomura, G.;Takahashi, C.;Yokota, M.;Mutoh, T.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2007년도 제33회 하계학술대회 초록집
    • /
    • pp.179-179
    • /
    • 2007
  • PDF

CONSTRUCTION, ASSEMBLY AND COMMISSIONING OF KSTAR MAIN STRUCTURES

  • Yang, Hyung-Lyeol;Bak, Joo-Shik;Kim, Byung-Chul;Choi, Chang-Ho;Kim, Woong-Chae;Her, Nam-Il;Hong, Kwon-Hee;Kim, Geung-Hong;Kim, Hak-Kun;Sa, Jeong-Woo;Kim, Hong-Tack;Kim, Kyung-Min;Kim, Sang-Tae
    • Nuclear Engineering and Technology
    • /
    • 제40권6호
    • /
    • pp.439-450
    • /
    • 2008
  • The KSTAR device succeeded in first plasma generation on $13^{th}$ June of 2008 through comprehensive system test and commissioning. Among various kinds of the key factors that decisively affected the project, success in the construction and assembly of the major tokamak structure was most important one. Every engineering aspects of each structure were finally confirmed in the integrated commissioning period, and there were no severe troubles and failures prevented the KSTAR device from operating during the commissioning and the first plasma experiments. As a result, all of the experiences and technologies achieved through the KSTAR construction process are expected to be important fundamentals for future construction projects of superconducting fusion devices. This paper summarizes key engineering features of the major structures and of the machine assembly.

The maintenance record of the KSTAR helium refrigeration system

  • Moon, K.M.;Joo, J.J.;Kim, N.W.;Chang, Y.B.;Park, D.S.;Kwag, S.W.;Song, N.H.;Lee, H.J.;Lee, Y.J.;Park, Y.M.;Yang, H.L.;Oh, Y.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권4호
    • /
    • pp.6-9
    • /
    • 2013
  • Korea Superconducting Tokamak Advanced Research (KSTAR) has a helium refrigeration system (HRS) with the cooling capacity of 9 kW at 4.5 K. Main cold components are composed of 300 tons of superconducting (SC) magnets, main cryostat thermal shields, and SC current feeder system. The HRS comprises six gas storage tanks, a liquid nitrogen tank, the room temperature compression sector, the cold box (C/B), the 1st stage helium distribution box (DB#1), the PLC base local control system interconnected to central control tower and so on. Between HRS and cold components, there's another distribution box (DB#2) nearby the KSTAR device. The entire KSTAR device was constructed in 2007 and has been operated since 2008. This paper will present the maintenance result of the KSTAR HRS during the campaign and discuss the operation record and maintenance history of the KSTAR HRS.

중성자 발생용 구형 집속빔 핵융합 장치의 방전현상 연구 (A Study on Discharge Phenomenon of Spherically Convergent Beam Fusion Device for Neutron Generation)

  • 박정호;주흥진;고광철
    • 한국전기전자재료학회논문지
    • /
    • 제20권5호
    • /
    • pp.467-470
    • /
    • 2007
  • Application field of neutron beam is very broad including industry, medicine and science. But the research and development and use of neutron beam is restricted within in narrow limits in this country, because neutron beam facility is insufficient - a big research facility of nuclear reactor(HANARO) and some small industrial facilities which use radioisotope neutron source are available. This paper compare and investigate the results of experiment and numerical analysis of the discharge in the spherically convergent beam fusion device which were expected as a portable neutron source. The spherically convergent beam fusion device will offer stability in neutron production, possibility of movement for convenience, low construction cost and higher neutron flux than radioisotope neutron source. The star mode discharge which efficiently generate neutron, were observed at both results.

마이크로머시닝을 이용한 세포 융합 기구에 관한 연구 (A Study of Cell Fusion Device Using Micromachining Technology)

  • 이상욱;김용권;김호성;차현철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1445-1447
    • /
    • 1995
  • A cell fusion device is designed and fabricated in order to electrofuse two cells between electrodes. Dielectrophoretic force is used to attract each cell and make a pearl chain of two cells. Two kinds of electrode structure are fabricated and tested the feasibility of the proposed device. The attraction of two radish cells or two Chinese cabbage cells on the electrodes is observed when AC voltage(1MHz, $V_{p-p}$=8V) is applied to the electrodes. The possibility of cell fusion device is shown through experiments.

  • PDF

Transflective liquid crystal display with single cell gap and simple structure

  • Kim, Mi-Young;Lim, Young-Jin;Jeong, Eun;Chin, Mi-Hyung;Kim, Jin-Ho;Srivastava, Anoop Kumar;Lee, Seung-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.340-343
    • /
    • 2008
  • This work reports the simple fabrication of the single cell gap transflective liquid crystal display (LCD) using wire grid polarizer. The nano sized wire grid polarizer was patterned on common electrode itself, on the reflective part of FFS (Fringe field switching) mode whereas the common electrode was unpatterned at transmissive part. However, this structure didn't show single gamma curve, so we further improved the device by patterning the common electrode at transmissive part. As a result, V-T curve of proposed structure shows single gamma curve. Such a device structure is free from in-cell retarder, compensation film and reflector and furthermore it is very thin and easy to fabricate.

  • PDF