• 제목/요약/키워드: Fusion Contrast

검색결과 142건 처리시간 0.024초

The Egect of Heavy Metal tons on the Differentiation of Cultured Muscle Cells of Chick Embryo (배양계배 근세포의 분화과정에 미치는 중금속 이온의 영향)

  • 위인선;이종빈
    • The Korean Journal of Zoology
    • /
    • 제30권4호
    • /
    • pp.410-416
    • /
    • 1987
  • The effect of heavy metal ions on the synthesis of proteins in cultured chick embryonic muscle cells were examined by labeling the cellular proteins with 35S-methionine and the surface proteins with Nalssl and lactoperokidase. The protein pattern in the cells cultured for 48 hrs showed little or no difference whether or not the cells were treated with any of the metal ions including Cu2+, Cd2+ and Hg2+, which are known to block the fusion of mypblasts. However, a 43kd protein disappeared from the control cells cultured for 72 hrs but remained unchanged in the cells treated with the metal ions. When analyzed for the syntheiic pattern of membrane proteins, addition of the ions (particularly of Cda+ and Cr3+) caused a marked increase in the level of 66kd protein, as compared to that in the untreated cells. By contrast, the level of 29kd protein was much higher in the control cells than in the cells treated with the metal ions. These results suggest that the heavy metal ions appear to block the degradation of 43kd soluble protein and 66kd membrane protein, perhaps by inhibiting a metalloprotease, which may be essential for the myogenic process of embryonic muscle cells.

  • PDF

Thermal and Solid State Assembly Behavior of Amphiphilic Aliphatic Polyether Dendrons with Octadecyl Peripheries

  • Chung, Yeon-Wook;Lee, Byung-Ill;Cho, Byoung-Ki
    • Macromolecular Research
    • /
    • 제16권2호
    • /
    • pp.113-119
    • /
    • 2008
  • A series of amphiphilic dendrons n-18 (n: generation number, 18: octadecyl chain) based on an aliphatic polyether denderitic core and octadecyl peripheries were synthesized using a convergent dendron synthesis consisting of a Williamson etherification and hydroboration/oxidation reactions. This study investigated their thermal and self-assembling behavior in the solid state using differential scanning calorimetry (DSC), Fourier transform infrared (FT-IR) absorption spectroscopy, and small angle X-ray scattering (SAXS). DSC indicated that the melting transition and the corresponding heat of the fusion of the octadecyl chain decreased with each generation. FT-IR showed that the hydroxyl focal groups were hydrogen-bonded with one another in the solid state. DSC and FT-IR indicated microphase-separation between the hydrophilic dendritic cores and hydrophobic octadecyl peripheries. SAXS data analysis in the solid state suggested that the lower-generation dendrons 1-18 and 2-18 self-assemble into lamellar structures based upon a bilayered packing of octadecyl peripheries. In contrast, the analyzed data of higher-generation dendron 3-18 is consistent with 2-D oblique columnar structures, which presumably consist of elliptical cross sections. The data obtained could be rationalized by microphase-separation between the hydrophilic dendritic core and hydrophobic octadecyl peripheries, and the degree of interfacial curvature associated with dendron generation.

Cervical Spine Malformations Associated With a 5q34-5q35.2 Micro-interstitial Deletion: A Case Report

  • Lee, Heewon;Kim, Joon Sung;Lim, Seong Hoon;Sul, Bomi;Hong, Bo Young
    • Annals of Rehabilitation Medicine
    • /
    • 제42권6호
    • /
    • pp.884-887
    • /
    • 2018
  • We report a female proband carrying a de novo 5q34-q35.2 deletion breakpoint, and review the unique skeletal phenotype and possible genotype related to this mutation. The patient presented with a persistent head tilt and limited head rotation. Non-contrast-enhanced three-dimensional computed tomography of the cervical spine revealed several malformations including a bone cleft in the right pars interarticularis, a bone defect in both C5 lamina and the transverse foramen at C2-C3, agenesis of the right articular process of C5, bony fusion of C4-C5, and subluxation of the craniocervical joints. Several deformities of the cervical spine seen in this patient have not been associated with the 5q deletion. A review of 5q-related mutations suggests that abnormalities associated with MSX2 gene might cause cervical spine abnormalities.

An Enhancement Technique for Backlit Images using Laplace Pyramid Fusion (라플라스 피라미드 융합을 이용한 역광영상의 개선 방법)

  • Kim, Jin Heon
    • Journal of IKEEE
    • /
    • 제26권2호
    • /
    • pp.292-298
    • /
    • 2022
  • There is a limit to improving the image quality through global processing of images taken under backlighting because too bright and dark parts are mixed in one scene. This paper introduces a method to improve the quality of a photo by making two virtual images that improve the dark and bright areas of a backlit photo, and fusing them with the original image into a Laplacian pyramid. The proposed method reduces the computational burden by using histogram stretching and gamma transformation that can be simplified with LUT when creating the two virtual images. In addition, in order to obtain a color-enhanced image, contrast conversion was performed only on the luminance using the HSV coordinate system. The proposed technique showed its effectiveness by calculating several NIQA indicators using standard image data sets.

Block-matching and 3D filtering algorithm in X-ray image with photon counting detector using the improved K-edge subtraction method

  • Kyuseok Kim;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2057-2062
    • /
    • 2024
  • Among photon counting detector (PCD)-based technologies, the K-edge subtraction (KES) method has a very high material decomposition efficiency. Yet, since the increase in noise in the X-ray image to which the KES method is applied is inevitable, research on image quality improvement is essential. Here, we modeled a block-matching and 3D filtering (BM3D) algorithm and applied it to PCD-based X-ray images with the improved KES (IKES) method. For PCD modeling, Monte Carlo simulation was used, and a phantom composed of iodine substances with different concentrations was designed. The IKES method was modeled by adding a log term to KES, and the X-ray image used for subtraction was obtained by applying the 3.0 keV range based on the K-edge region of iodine. As a result, the IKES image using the BM3D algorithm showed the lowest normalized noise power spectrum value. In addition, we confirmed that the contrast-to-noise ratio and no-reference-based evaluation results when the BM3D algorithm was applied to the IKES image were improved by 29.36 % and 20.56 %, respectively, compared to the noisy image. In conclusion, we demonstrated that the IKES imaging technique using a PCD-based detector and the BM3D algorithm fusion technique were very efficient for X-ray imaging.

Comparative Study on the Hydrogen Embrittlement Behavior of Additively Manufactured 316L Stainless Steel and CoCrFeNi Medium-Entropy Alloy (적층제조된 316L 스테인리스강 및 CoCrFeNi 중엔트로피 합금의 수소취화 거동 비교)

  • Jae Yeong Jung;Ji Yoon Jung;Dong-Hyun Lee
    • Journal of the Korean Society for Heat Treatment
    • /
    • 제37권5호
    • /
    • pp.237-246
    • /
    • 2024
  • In this study, hydrogen embrittlement was investigated for 316L stainless steel (SS316L) and CoCrFeNi medium-entropy alloy (MEA) fabricated by laser-powder bed fusion. The in-situ hydrogen charging tensile tests revealed that the reduction in ductility due to hydrogen was more significant in the CoCrFeNi MEA, compared to the SS316L. In the case of SS316L, hydrogen-assisted cracks (HACs) were observed mainly on the surface, whereas in CoCrFeNi, cracks were found not only at the edges but also in the central region. HACs analysis confirmed that transgranular (TG) cracks were predominant in SS316L, whereas only intergranular cracks were formed in the CoCrFeNi MEA. The difference in hydrogen embrittlement resistance between SS316L and CoCrFeNi was discussed in terms of the differences in deformation microstructure and hydrogen diffusivity, as investigated through electron channeling contrast imaging and nanoindentation.

Effect of CT Contrast Media on Radiation Therapy Planning (Head & Neck Cancer and Prostate Cancer) (CT조영제가 방사선치료계획(두경부, 전립선)에 미치는 영향)

  • Jang, Jaeuk;Han, Manseok;Kim, Minjeong;Kang, Hyeonsoo
    • Journal of the Korean Magnetics Society
    • /
    • 제26권5호
    • /
    • pp.173-178
    • /
    • 2016
  • This study is to evaluate the effect of a Contrast Media (CM) on dose calculations and clinical significance in Radiation (Electromagnetic wave) Therapy (RT) plans for head & neck (H&N) and prostate cancer. Pinnacle 8.0 system was used to measure the change of Electron Density (ED) of the tissue for CM. To determine the effect of dose calculation due to CM, we did the RT planning for 30 patients. To compare the ED and dose calculations of RT plans, 3D CRT and IMRT plans were do with pinnacle and Tomotherapy planning system. Mean difference of ED between enhanced and unenhanced CT was less than 4%: H&N Target Volume (TV) 2.1%, parotid 1.9%, SMG 3.6%, tongue 0.9%, spinal cord 0.3%, esophagus 2.6%, mandible 0.1% and prostate TV 0.7%, lymph node 1.1%, bladder 1.2%, rectum 1.5%, small bowel 1.2%, colon 0.6%, penile bulb 0.8%, femoral head -0.2%. The dose difference between RT plan using CM and without CM showed an increase of dose in TV. The rate of increase was less than 2.5% (3D CRT: H&N 0.69~2.51%, prostate 0.04~1.14%, IMRT: H&N 0.58~1.31%, prostate 0.36~1.04%). RT plans using a CM has the insignificant effect on the organs and TV, so this error is allowable clinically. However, the much more accurate plan is possible as to image fusion (CM and without CM images) to ROI contour and when dose calculation, use the without CM image. Using the fusion of 'ROI import' perform calculations on without CM, it will be able to reduce the error (1~3%) caused by the CM.

A study of usefulness for the plan based on only MRI using ViewRay MRIdian system (ViewRay MRIdian System을 이용한 MRI only based plan의 유용성 고찰)

  • Jeon, Chang Woo;Lee, Ho Jin;An, Beom Seok;Kim, Chan young;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • 제27권2호
    • /
    • pp.131-143
    • /
    • 2015
  • Purpose : By comparing a CT fusion plan based on MRI with a plan based on only MRI without CT, we intended to study usefulness of a plan based on only MRI. And furthermore, we intended to realize a realtime MR-IGRT by MRI image without CT scan during the course of simulation, treatment planning, and radiation treatment. Materials and Methods : BBB CT (Brilliance Big Bore CT, 16slice, Philips), Viewray MRIdian system (Viewray, USA) were used for CT & MR simulation and Treatment plan of 11 patients (1 Head and Neck, 5 Breast, 1 Lung, 3 Liver, 1 Prostate). When scanning for treatment, Free Breathing was enacted for Head&Neck, Breast, Prostate and Inhalation Breathing Holding for Lung and Liver. Considering the difference of size between CT and Viewray, the patient's position and devices were in the same condition. Using Viewray MRIdian system, two treatment plans were established. The one was CT fusion treatment plan based on MR image. Another was MR treatment plan including electron density that [ICRU 46] recommend for Lung, Air and Bone. For Head&Neck, Breast and Prostate, IMRT was established and for Lung and Liver, Gating treatment plan was established. PTV's Homogeneity Index(HI) and Conformity Index(CI) were use to estimate the treatment plan. And DVH and dose difference of each PTV and OAR were compared to estimate the treatment plan. Results : Between the two treatment plan, each difference of PTV's HI value is 0.089% (Head&Neck), 0.26% (Breast), 0.67% (Lung), 0.2% (Liver), 0.4% (Prostate) and in case of CI, 0.043% (Head&Neck), 0.84% (Breast), 0.68% (Lung), 0.46% (Liver), 0.3% (Prostate). As showed above, it is on Head&Neck that HI and CI's difference value is smallest. Each difference of average dose on PTV is 0.07 Gy (Head&Neck), 0.29 Gy (Breast), 0.18 Gy (Lung), 0.3 Gy (Liver), 0.18 Gy (Prostate). And by percentage, it is 0.06% (Head&Neck), 0.7% (Breast), 0.29% (Lung), 0.69% (Liver), 0.44% (Prostate). Likewise, All is under 1%. In Head&Neck, average dose difference of each OAR is 0.01~0.12 Gy, 0.04~0.06 Gy in Breast, 0.01~0.21 Gy in Lung, 0.06~0.27 Gy in Liver and 0.02~0.23 Gy in Prostate. Conclusion : PTV's HI, CI dose difference on the Treatment plan using MR image is under 1% and OAR's dose difference is maximum 0.89 Gy as heterogeneous tissue increases when comparing with that fused CT image. Besides, It characterizes excellent contrast in soft tissue. So, radiation therapy using only MR image without CT scan is useful in the part like Head&Neck, partial breast and prostate cancer which has a little difference of heterogeneity.

  • PDF

Meningeal Hemangiopericytomas and Meningomas: a Comparative Immunohistochemical and Genetic Study

  • Trabelsi, Saoussen;Mama, Nadia;Chourabi, Maroua;Mastouri, Maroua Haddaji;Ladib, Mohamed;Popov, Sergey;Burford, Anna;Mokni, Moncef;Tlili, Kalthoum;Krifa, Hedi;Jones, Chris;Yacoubi, Mohamed Tahar;Saad, Ali;Brahim, Dorra H'mida-Ben
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권16호
    • /
    • pp.6871-6876
    • /
    • 2015
  • Background: The meningeal hemangiopericytoma (MHPC) is a vascular tumor arising from pericytes. Most intracranial MHPCs resemble meningiomas (MNGs) in their clinical presentation and histological features and may therefore be misdiagnosed, despite important differences in prognosis. Materials and Methods: We report 8 cases of MHPC and 5 cases of MNG collected from 2007 to 2011 from the Neuro-Surgery and Histopathology departments. All 13 samples were re reviewed by two independent pathologists and investigated by immunohistochemistry (IHC) using mesenchymal, epithelial and neuro-glial markers. Additionally, we screened all tumors for a large panel of chromosomal alterations using multiplex ligation probe amplification (MLPA). Presence of the NAB2-STAT6 fusion gene was inferred by immunohistochemical staining for STAT6. Results: Compared with MNG, MHPCs showed strong VIM (100% of cases), CD99 (62%), bcl-2 (87%), and p16 (75%) staining but only focal positivity with EMA (33%) and NSE (37%). The p21 antibody was positive in 62% of MHPC and less than 1% in all MNGs. MLPA data did not distinguish HPC from MNG, with PTEN loss and ERBB2 gain found in both. By contrast, STAT6 nuclear staining was observed in 3 MHPC cases and was absent from MNG. Conclusions: MNG and MHPC comprise a spectrum of tumors that cannot be easily differentiated based on histopathology. The presence of STAT6 nuclear positivity may however be a useful diagnostic marker.

The Study on Scattered Radiation Effects According to Acquisition of X-ray Imaging using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 X선 의료영상 획득 시 산란선 발생 영향 연구)

  • Park, Ji-Koon;Kang, Sang-Sik;Yang, Seung-Woo;Heo, Ye-Ji;Kim, Kyo-Tae
    • Journal of the Korean Society of Radiology
    • /
    • 제12권5호
    • /
    • pp.549-555
    • /
    • 2018
  • The medical imaging technique images the contrast formed based on the difference in absorption coefficient of X-rays which changes according to the composition and thickness of the object. At this time, not only primary rays entering the image detector but also scattered rays greatly affect the image quality. Therefore, in this paper, Forward scattering rate and Scattered to primary ratio analysis were performed through Monte Carlo simulation in order to consider influence of scattered ray generated according to object thickness and radiation exposure area change on image quality. In the study, the Forward scattering rate corresponding to the thickness of the object was analyzed at a maximum of 15.3%p and the Scattered to primary ratio was analyzed at 2.00 to 4.54, but it was analyzed as maintaining a constant value for radiation exposure area change. Based on these results, the thickness of the object should be considered as a factor influencing the quality of the image, but radiation exposure area verified that it is a factor that does not affect the image quality. We believe that the results of this research can be utilized as basic information of scattered radiation to improve image quality.