• Title/Summary/Keyword: Further compression

Search Result 361, Processing Time 0.023 seconds

Block Based Blind & Secure Gray Image Watermarking Technique Based on Discrete Wavelet Transform and Singular Value Decomposition

  • Imran, Muhammad;Harvey, Bruce A.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.2
    • /
    • pp.883-900
    • /
    • 2017
  • In this paper block based blind secure gray image watermarking scheme based on discrete wavelet transform and singular value decomposition is proposed. In devising the proposed scheme, security is given high importance along with other two requirements: robustness and imperceptibility. The use of discrete wavelet transform not only improves robustness but the selection of bands with high tolerance towards noise caused an improvement in terms of imperceptibility. The robustness further improved due to the involvement of singular vectors along with singular values in watermark embedding and extraction process. Finally, to achieve security, the selected DWT band is decomposed into smaller blocks and random blocks are chosen for modification. Furthermore, the elements of left and right singular vectors of selected blocks are chosen based on their dependence upon each other for watermark embedding. Various experiments using different images as host and watermark were conducted to examine and validate the proposed technique. Additionally, the proposed technique is tested against various attacks like compression, affine transformation, cropping, translation, X shearing, scaling, Y shearing, filtering, blurring, different kinds of noises, histogram equalization, rotation, etc. Lastly, the proposed technique is compared with state-of-the-art watermarking techniques and their comparison shows significant improvement of proposed scheme over existing techniques.

Video Coding Algorithm Based on High Efficiency Video Coding (HEVC) and Hybrid Transforms

  • Wang, Chengyou;Shan, Rongyang;Zhou, Xiao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.9
    • /
    • pp.4448-4466
    • /
    • 2018
  • In recent years, due to its high efficiency and better performance, the high efficiency video coding (HEVC) has become the most common compression standard in the field of video coding. In this paper, the framework of HEVC is deeply analyzed, and an improved HEVC video coding algorithm based on all phase biorthogonal transform (APBT) is proposed, where APBT is utilized to replace the discrete cosine transform (DCT) and discrete sine transform (DST) in original HEVC standard. Based on the relationship between APBT and DCT, the integer APBT is deduced. To further improve the coding performance, an optimal HEVC video coding algorithm based on hybrid APBT is proposed. The coding performance of the proposed HEVC coding algorithm is improved without increasing the complexity. Experimental results show that compared with HEVC standard algorithm, the improved HEVC video coding algorithm based on hybrid APBT can improve the coding performance of chrominance components by about 0.3%.

DC Magnetron Sputtering of Cr/Cu/Cr Metal Electrodes for AC Plasma Display panel (DC Magnetron Sputtering 법에 의한 AC Plasma Display panel의 Cr/Cu/Cr 금속전극 제조)

  • 남대현;이경우;박종완
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.8
    • /
    • pp.704-710
    • /
    • 2000
  • Metal electrode materials for plasma display panel should have low electrical resistivity in order to maintain stable gas discharge and have fast response time. They should also hae good film uniformity adhesion and thermal stability. In this study Cr/Cu/Cr metal electrode structure is formed by DC magnetron sputtering. Cr and Cu films were deposited on ITO coated glasses with various DC power density and main pressures as the major parameters. After metal electrodes were formed a heat treatment was followed at 55$0^{\circ}C$ for 20 min in a vacuum furnace. The intrinsic stress of the sputtered Cr film passed a tensile stress maximum decreased and then became compressive with further increasing DC power density. Also with increasing the main pressure stress turned from compression to tension. After heat the treatment the electrical resistivity of the sputtered Cu film of 2${\mu}{\textrm}{m}$ in thickness prepared at 1 motor with the applied power density of 3.70 W/cm$^2$was 2.68 $\mu$$\Omega$.cm With increasing the main pressure the DC magnetron sputtered Cu film became more open structure. The heat treatment decreased the surface roughness of the sputtered Cr/Cu/Cr metal electrodes.

  • PDF

A Case Report on Cervical Myelopathy Applied Chuna Treatment (추나 요법을 적용한 경수부 척수 손상 환자의 경과관찰 1례)

  • Lee, Jin-Bok;Cho, Yi-Hyun;Im, Jeong-Gyun;Jeong, Si-Yeong
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.5 no.1
    • /
    • pp.81-89
    • /
    • 2010
  • Objects : This study was to report a clinical effect of Chuna Treatment for a patient diagnosed by Magnetic Resonance Imaging(MRI) as Cervical Myelopathy. Methods: In order to alleviate shoulder pain and neck stiffness, the patient was treated by acupuncture therapy, herbal medicine, phamacopucture, cervical traction technique of Chuna treatment and conservative managements. To evaluate the effect of the treatment, Recovery rate of Hirabayashi, VAS(Visual Anlaogue Scale), NDI and ROM(Range of Motion) were used. Lhermitte's sign, Valsalva test, Distraction test, Compression test and Spurling test were carried out. Results: VAS, NDI and ROM were improved and Recovery rate was 100%. Conclusions: Korean Treatment can be effectively used for a patient with Cervical Myelopathy. Further clinical studies are needed to verify the findings.

  • PDF

A Case Report on Cervical Spinal Stenosis with Ossification of posterior Longitudinal Ligament Applied Chuna Treatment (추나요법을 적용한 후종인대골화증을 동반한 경추척추관협착증 환자의 경과관찰 1례)

  • Lee, Jin-Bok;Lee, Hwi-Yong;Cho, Yi-Hyun;Jeong, Si-Yeong
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.4 no.1
    • /
    • pp.85-94
    • /
    • 2009
  • Objects : This study was to report a clinical effect of Korean Treatment for a patient diagnosed by Computed Tomography as Cervical Spinal Stenosis with Ossification of posterior Longitudinal Ligament. Methods : In order to alleviate left shoulder pain and neck stiffness, the patient was treated by acupuncture therapy, herbal medicine, distilled herbal injection, cervical traction technique of Chuna treatment and conservative managements. To evaluate the effect of the treatment, Recovery rate of Hirabayashi, VAS(Visual Anlaogue Scale), NDI and ROM(Range of Motion) were used. Lhermitte's sign, Valsalva test, Distraction test, Compression test and Spurling test were carried out. Results : VAS, NDI and ROM were improved and Recovery rate was 100%. Conclusions : Korean Treatment can be effectively used for a patient with Cervical Spinal Stenosis with OPLL. Further clinical studies are needed to verify the findings.

  • PDF

Review on Conservative Treatment of Spasmodic Torticollis -Reviewing Articles Published after Year 2000 (경련성 사경증의 보존적 치료 효과에 대한 문헌적 고찰 -2000년 이후 발표된 논문을 중심으로)

  • Kim, Kyoung-Seok;Kim, Sung-Soo;Chung, Seok-Hee;Lee, Jong-Soo
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.5 no.1
    • /
    • pp.145-156
    • /
    • 2010
  • Objects: This study was to report a clinical effect of Chuna Treatment for a patient diagnosed by Magnetic Resonance Imaging(MRI) as Cervical Myelopathy. Methods: In order to alleviate shoulder pain and neck stiffness, the patient was treated by acupuncture therapy, herbal medicine, pharmacopucture, cervical traction technique of Chuna treatment and conservative managements. To evaluate the effect of the treatment, Recovery rate of Hirabayashi, VAS(Visual Analogue Scale), NDI and ROM(Range of Motion) were used. Lhermitte's sign, Valsalva test, Distraction test, Compression test and Spurling test were carried out. Results: VAS, NDI and ROM were improved and Recovery rate was 100%. Conclusions: Korean Treatment can be effectively used for a patient with Cervical Myelopathy. Further clinical studies are needed to verify the findings.

  • PDF

Partially confined circular members subjected to axial compression: Analysis of concrete confined by steel ties

  • Eid, R.;Dancygier, A.N.
    • Structural Engineering and Mechanics
    • /
    • v.21 no.6
    • /
    • pp.737-765
    • /
    • 2005
  • This paper presents a theoretical model for the behavior of partially confined axi-symmetric reinforced concrete members subjected to axial load. The analysis uses the theories of elasticity and plasticity to cover the full range of the concrete behavior. Analysis of the elastic range of the problem involves boundary conditions that are defined along a relatively simple geometry. However, extending the analysis into the plastic range involves difficulties that arise from the irregular geometry of the boundary between the plastic zone and the elastic zone, a boundary which is also changing as the axial load increases. The solution is derived by replacing the discrete steel ties with an equivalent tube of thickness $t_{eq}$ and by analyzing the concrete cylinder, which is uniformly confined by the equivalent tube. The equivalency criterion initiates from a theoretical analysis of the problem in its elastic range where further finite element analysis shows that this criterion is valid also for the plastic range of the cylinder material. According to the proposed model, the efficiency of the lateral reinforcement can be evaluated by the equivalent thickness $t_{eq}$. Comparison with published test results of confined reinforced concrete stress-strain curves shows good agreement between the test and the analytical results.

Comparative in-plane pushover response of a typical RC rectangular wall designed by different standards

  • Dashti, Farhad;Dhakal, Rajesh P.;Pampanin, Stefano
    • Earthquakes and Structures
    • /
    • v.7 no.5
    • /
    • pp.667-689
    • /
    • 2014
  • Structural walls (also known as shear walls) are one of the common lateral load resisting elements in reinforced concrete (RC) buildings in seismic regions. The performance of RC structural walls in recent earthquakes has exposed some problems with the existing design of RC structural walls. The main issues lie around the buckling of bars, out-of plane deformation of the wall (especially the zone deteriorated in compression), reinforcement getting snapped beneath a solitary thin crack etc. This study compares performance of a typical wall designed by different standards. For this purpose, a case study RC shear wall is taken from the Hotel Grand Chancellor in Christchurch which was designed according to the 1982 version of the New Zealand concrete structures standard (NZS3101:1982). The wall is redesigned in this study to comply with the detailing requirements of three standards; ACI-318-11, NZS3101:2006 and Eurocode 8 in such a way that they provide the same flexural and shear capacity. Based on section analysis and pushover analysis, nonlinear responses of the walls are compared in terms of their lateral load capacity and curvature as well as displacement ductilities, and the effect of the code limitations on nonlinear responses of the different walls are evaluated. A parametric study is also carried out to further investigate the effect of confinement length and axial load ratio on the lateral response of shear walls.

Deep-beams with indirect supports: numerical modelling and experimental assessment

  • Pimentel, Mario;Cachim, Paulo;Figueiras, Joaquim
    • Computers and Concrete
    • /
    • v.5 no.2
    • /
    • pp.117-134
    • /
    • 2008
  • An experimental and numerical research was conducted to gain a deeper insight on the structural behaviour of deep-beams with indirect supports and to assess the size effects in the ultimate state behaviour. The experimental campaign focused on the influence of the reinforcement tie distribution height on the compression check of the support region and on the benefits of using unbonded prestressing steel. Three reduced scale specimens were tested and used to validate the results obtained with a nonlinear finite element model. As a good agreement could be found between the numerical and the experimental results, the numerical model was then further used to perform simulations in large scale deep-beams, with dimensions similar to the ones to be adopted in a practical case. Two sources of size effects were identified from the simulation results. Both sources are related to the concrete quasi-brittle behaviour and are responsible for increasing failure brittleness with increasing structural size. While in the laboratory models failure occurred both in the experimental tests as well as in the numerical simulations after reinforcement yielding, the numerically analysed large scale models exhibited shear failures with reinforcement still operating in the elastic range.

A Numerical Study on Refrigerant Distribution according to the Insertion Depth of the Distributor-Outlet Pipes in an Air-Conditioning System (공조 시스템 내의 분배기 출구관의 삽입깊이에 따른 유량분포연구)

  • Lee, Hee Won;Park, Il Seouk
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.491-496
    • /
    • 2015
  • Generally, the phase of the refrigerants that circulate in air-conditioning systems is repeatedly changed from liquid to gas and from gas to liquid. In vapor-compression refrigeration, the refrigerant at the inlet of the evaporator is in a gas-liquid two-phase state; therefore, to enhance the heat-transfer performance of the evaporator, the even distribution of the refrigerant across multiple passages of the evaporator is essential. Unlike the distribution of a single-phase refrigerant, multi-phase distribution requires further considerations. It is known that the multi-phase distribution at the outlet of the distributor is affected by factors such as the operating condition, the distributor's shape, and the insertion depth of the outlet pipes; here, the insertion depth of the outlet pipes is especially significant. In this study, for a cylindrical distributor with a 90-degree bend entrance and three outlet pipes, the flow uniformity at the outlet pipes was numerically tested in relation to variations of the insertion depth of the outlet pipes.