• Title/Summary/Keyword: Furnace

Search Result 3,771, Processing Time 0.029 seconds

Properties of Blast Furnace Slag Cement Modified with Electric Arc Furnace Slag (전기로 슬래그를 치환한 고로 슬래그 시멘트의 특성)

  • Lee, Seung-Heun;Hwang, Hae-Jeong;Kwon, Sung-Ku
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.7 s.290
    • /
    • pp.408-414
    • /
    • 2006
  • Properties of slag cement that contained 50 wt% of blast furnace slag were studied when replaced blast furnace slag powder with electric arc furnace slag powder. Electric arc furnace slag was aged for about 2 months in the air by being crushed to be 1-3 mm in size. As a result of the experiment, it was proven that the water content for obtaining the same consistency became decreased as slag is replaced with electric arc furnace slag instead of blast furnace slag. Also, the workability of mortar increased about 30% at the same ratio of water to binder when blast furnace slag was completely replaced with electric arc furnace slag. The compressive strength of mortar on the 28 days increased when a slag replacement rate became 10 wt%, however, it rather decreased when the slag replacement rate exceeded 10 wt%. The heat of hydration became higher for the first 14 h in case of the replacement of slag cement by electric arc furnace slag. Yet, it decreased when 14 h had passed. Therefore, when all blast furnace slag was replaced with electric arc furnace slag, about 15 cal/g heat of hydration decreased when it passed about 72 h.

A Study of Harmonics by Arc Furnace Operating for Demand Side Management (수요관리를 위한 아크로 운전 상태에 따른 고조파 연구)

  • Park, Kyung-Ho;Kim, Jae-Chul;Park, Hyun-Teak;Im, Sang-Kug;Oh, Dong-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.17-19
    • /
    • 2003
  • Electric arc furnace has consumed plenty of power. Hence electric arc furnace can be expected to use for demand side management. When electric arc furnace use for demand side management, electric arc furnace frequently occur a starting and a stop. Electric arc furnace irregularity change consumption of power. Due to character of time-varing and non-linear, electirc arc furnace has a problem with voltage quality(flicker, harmonics). Producted harmonic in electric art furnace is different any harmonic source because of electric arc furnace peculiar operating. Accordingly, analysis for generated harmonic in electric arc furnace operating is demanded. This paper analyze effect of harmonic by arc furnace operating.

  • PDF

Effect of Blast Furnace Slag, Hwang-toh and Reinforcing Fibers on The Physical and Mechanical Properties of Porous Concrete Using Blast Furnace Slag Coarse Aggregate (고로슬래그 골재를 사용한 다공성 콘크리트의 물리·역학적 특성에 미치는 고로슬래그 미분말, 황토 및 보강섬유의 효과)

  • Lee, Jin-Hyung;Park, Chan-Gi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.5
    • /
    • pp.53-60
    • /
    • 2010
  • The effects of blast furnace slag, hwang-toh, and reinforcing fiber on the physical and mechanical properties of porous concrete using blast furnace slag coarse aggregates have been evaluated in this study. The effect of the depending on replacement ratio of blast furnace slag to cement was investigated such that the replacement ratio was varied to 0 %, 25 % and 50 %. Also, the replacement ratios of hwang-toh were 0, 20 and 30 %. The polyvinyl alcohol fiber was used for the reinforcing fiber. A series of pH, unit mass, and void ratio tests have been performed to study the physical properties of the porous concrete using blast furnace slag coarse aggregates with the polyvinyl alcohol fiber and the replacement ratios of blast furnace slag, hwang-toh, while a series of compressive tests have been performed to evaluate the strength property depending on polyvinyl alcohol fiber and the replacement ratios of blast furnace slag, hwang-toh. The test results indicated that the physical and mechanical properties of porous concrete using blast furnace slag coarse aggregates is affected by the replacement ratio of blast furnace slag, and the fiber contents. According to the tests with polyvinyl alcohol fiber contents, the void ratio was decreased and the compressive strength was upgraded.

Engineering properties of mortar with the variation of blast furnace slag from different production areas (고로슬래그 미분말의 산지별 치환율 변화에 따른 모르타르의 공학적 특성)

  • Park, Jae-Yong;Zhao, Yang;Jung, Sang-Woon;Jo, Man-Ki;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.206-207
    • /
    • 2014
  • Blast furnace slag is one kind of industrial by-product and was utilized with recycled fine aggregates for the manufacture of zero cement mortar. As the blast furnace slag was from different areas, the strength of the specimen using blast furnace slag showed different performances. In this study, blast furnace slag generated in different areas in Korea has been chosen, fundamental performances of the blast furnace slag blended mortar has been tested to evaluate the quality of the blast furnace slag. Results showed that difference for flowability is limited. As the alkali activation of the blast furnace slag, the compressive strength showed different results. The flexural strength showed little difference when the aggregates and types of blast furnace slag changed.

  • PDF

Setting and Strength Properties of Mortar Containing Steel Furnace Slag Dust

  • Choi, Yun-Wang;Chung, Jee-Seung;Moon, Dae-Joong;Shin, Hwa-Cheol;Jang, Lee-Duck
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.193-196
    • /
    • 2003
  • In this paper, the experimental investigation for the setting properties of cement paste, the consistency and strength properties of mortar with steel furnace slag dust was performed and compared with those of cement paste and mortar with ground granulated blast furnace slag. When steel furnace slag dust was replaced with normal portland cement, setting time and flow value indicated to good results like as mortar with ground granulated blast furnace slag. However, mortar with steel furnace slag dust expressed to appreciably strength devaluation according to containing ratio, and did not indicate the pozzolanic reaction like as ground granulated blast furnace slag.

  • PDF

Experimental Study on Frost Resistance of High-Strength Concrete Using Granulated Blast-Furnace Slag (고로슬래그 미분말을 흔입한 고강도콘크리트의 내동해성에 관한 실험적 연구)

  • 김무한;권영진;강석표;박선규
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.4
    • /
    • pp.41-48
    • /
    • 2000
  • This study is to investigate for the frost resistance of high-strength concrete using finely ground granulated blast-furnace slag with experimental parameters, such as water/binder ratio, replacement proportion of granulated blast-furnace slag, air content and methods of curing. The high-strength concrete using granulated blast-furnace slag is effective to resist frost and decrease scaling. The more increasable replacement proportion of granulated blast-furnace slag is, the better the effect is. The high-strength concrete using granulated blast-furnace slag needs hydrating adequately to prevent deterioration by drying in the early curing period. The micro structure of high-strength concrete, increased to the pore number with diameter of 0.03~0.1mm, is changed by using granulated blast-furnace slag, but is presented differently according to water/binder ration and replacement proportion of granulated blast-furnace slag.

A Numerical Study on the Slab Heating Characteristics in a Reheating Furnace with the Formation and Growth of Scale on the Slab Surface (스케일 층의 생성 및 성장을 고려한 가열로 내 슬랩의 승온 특성 해석에 관한 연구)

  • Lee, Dong-Eun;Jang, Jung-Hyun;Kim, Chong-Min;Hong, Dong-Jin;Park, Hae-Doo;Park, Yun-Beom;Kim, Man-Young
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.109-112
    • /
    • 2008
  • In this work, a mathematical heat transfer model of a walking-beam type reheating furnace that can predict the formation and growth of the scale layer, which is produced due to oxidative reaction between the furnace oxidizing atmosphere and the steel surface in the reheating furnace, has been developed. The model can also predict the heat flux distribution within the furnace and the temperature distribution in the slab and scale throughout the reheating furnace process by considering the heat exchange between the slab and its surroundings in the furnace, including radiant heat transfer among the slabs, the skids, the hot gases and the furnace wall as well as the gas convection heat transfer in the furnace. Using the model developed in this work, the effects of the scale layer on the heat transfer characteristics and temperature behavior of the slab is investigated. A comparison is also made between the predictions of the present model and the data from an in situ measurement in the furnace, and a reasonable agreement is founded.

  • PDF

Thermal Stress Analysis of Spent Fuel Vol-oxidizer Furnace on the Internal Pressure (내부 압력변화에 대한 사용후핵연료 분말화장치 가열로의 열 응력 해석)

  • Kim, Y.H.;Jung, J.H.;Hong, D.H.;Park, B.S.;Lee, J.K.;Yoon, J.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.136-140
    • /
    • 2006
  • We are developing a vol-oxidizer which transforms the spent $UO_2$ pellets into the $U_3O_8$ power through oxidizing process. The vol-oxidizer consists of furnace, filter, heater and valve etc. When the filter is blocked by the powder, the internal pressure of the furnace is increased owing to the air flow restriction. Then, the furnace vessel is swelled and deformed by it. In this paper, we proposed a procedure of the thermal analysis for furnace vessel design of spent fuel vol-oxidizer. In this work, we determined the thickness of the furnace through analyzing the internal pressure and the thermal stress of the furnace with respect to various pressure and temperature. To analyze the thermal stress, we used ANSYS 8.0 for constructing a FEM model of the furnace, and then analyzed it based on the ASME code. We also surveyed the material property and yield stress of SUS304 with various temperature. Analysis results are compared with the yield stress of the material. We manufactured the furnace and conduct the verification experiments.

  • PDF

The Experimental study on the property of concrete which used Blast furnace slag aggregate (고로슬래그 골재를 사용한 콘크리트 특성에 대한 실험적 연구)

  • 박정우;김상미;김광기;임남기;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.489-494
    • /
    • 2001
  • Several studies have reported that Granulated Blast-Furnace Slag improved the properties of concrete. The Granulated Blast-Furnace Slag could be a good alternative in the shortage of aggregate situation. Slag shows the possibility of influential aggregate and effect of environment preservation. This study presents that the basic properties of fresh concrete using Air-cooled Blast-furnace slag aggregate and Water-cooled Blast-furnace slag aggregate. Testing Factors of this study are concrete slump, slump loss, bleeding, and air contents. The result of this study is below. 1) In case of proportion slag and grave is 50 to 50, the biggest slump value is measured. 2) In the concrete using of air-cooled Blast-furnace slag aggregate, the bleeding capacity is a little. In the concrete using of Water-cooled Blast-furnace slag aggregate, the bleeding capacity goes up to 50% increase. 3) As substitution rate of the granulated blast-furnace slag goes up, air content is increased.

  • PDF

Experimental Analysis of Radiative Heat Interchange on Furnace Exit Plane of a Steam Boiler

  • Ahn, Kook-Young;Antonovsky, Vjacheslav-Ivanovich
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.239-247
    • /
    • 2001
  • Measured radiative heat fluxes on the furnace exit plane of a heavy duty power boiler of steam output 1650 T/h are discussed. A high-ash pulverized bituminous coal was used. Such measurements are necessary to improve heat fluxes inside a steam boiler furnace was manufactured. An extra small heat radiation sensor was placed in the water cooled head of the probe. The sensor had no direct contact with furnace gases and measured only the radiant energy. There was no exposure to convective heat transfer. With the radiometric probe, one can obtain a spherical indicatrix of radiation intensity as well as hemispherical radiative heat flux incident on any surface passing through a measuring point inside the furnace. Thus, the quantity of radiation energy, passing through the furnace exit plane, to the convective heating surfaces and the quantity of radiation energy going in the opposite direction were measured. A formula for relative radiative heat flux on the furnace exit plane has been proposed.