• Title/Summary/Keyword: Fundamental Factors

Search Result 1,288, Processing Time 0.027 seconds

A Study on the Actual Operating Conditions of Guard Lamps and its Maintenance Problems (국내 보안등 운용실태 조사 및 유지관리성 검토 연구)

  • Jung, Jong-Wook;Jung, Jin-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.8
    • /
    • pp.89-95
    • /
    • 2008
  • This paper describes the checking results and some problems of guard lamps installed in the field. The guard lamp providing night security for people is installed outdoors and exposed to the natural factors causing secular ageing and the people's vandalism, etc., thus it is prone to get troubles in function. In fact, the guard lamps has been left without considering the fundamental measures in the legislative system in spite of the loss of lives due to the electric shock accidents repetitively taking place every year. This study arouses people's attention to the risk due to the lack of management and maintenance of the guard lamp by investigating the recent technology and the actual operating conditions and some problems and countermeasures were ultimately deduced. In this process, we reflected on the various opinions through fieldwork and had a couple of consultations with field staffs, manufacturers concerned and active officers with local autonomous entities.

Design of Compensated Digital Interface Circuits for Capacitive Pressure Sensor (용량형 압력센서용 디지탈 보상 인터페이스 회로설계)

  • Lee, Youn-Hee;Sawada, Kouji;Seo, Hee-Don;Choi, Se-Gon
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.5
    • /
    • pp.63-68
    • /
    • 1996
  • In order to implement the integrated capacitive pressure sensors, which contains integrated interface circuits to detect the electrical output signal, several main factors that have a bad effect on the characteristics of sensors must be improved, such as parasitic capacitance effects, temperature/thermal drift, and the leakage current of a readout circuitry. This paper describes the novel design of the dedicated CMOS readout circuitry that is consists of two capacitance to frequency converters and 4 bit digital logic compensating circuits. Dividing the oscillation frequency of a sensing sensor by that of reference sensor, this circuit is designed to eliminate the thermal/temperature drift and the effect of the leakage currents, and to access a digital signals to obtain a high signal-to-noise(S/N)ratio. Therefore, the resolution of this circuit can be increased by increasing the number of the digital bits. Digital compensated circuits of this circuits, except for the C-F converters, are fabricated on a FPGA chip, and fundamental performance of the circuits are evaluated.

  • PDF

Fundamental Studies for the Automatic Control System in the Greenhouse Using Microcomputer(II) -A Development of a Controller for an Automatic Control System- (마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(II) -자동화 시스템의 종합제어기 개발-)

  • 김진현;김철수
    • Journal of Biosystems Engineering
    • /
    • v.20 no.1
    • /
    • pp.73-86
    • /
    • 1995
  • The automatic control system in the greenhouse have to be developed to the direction of considering various factors the variables such as condition of the cultivation and greenhouse, the properties and types of products. Therefore, it is more important to set up variables appropriately than the problems of automatic control system itself, and the automatic control system which satisfy these problems should be simplified in the aspect of operation. In addition, even the individual automations are not perfect yet, so more studies are required for the development of comprehensive automatic system in korea. This study was carried out to automatize environment control systems for greenhouse, especially from most intensive labor requiring parts such as watering, irrigating liquefied fertilizer, spraying chemicals, mixing and ventilation system, etc. The results are summarized as follows. 1. Control type tensiometer was expected to be desirable in the automation of watering system, therefore, a new tensiometer was designed and developed through this study. 2. The chemical spraying system developed through this study was found to be excellent in the aspect of operation. 3. When pulse type water discharge meter was used in the mixing of liquefied fertilizer and chemical solution, the error of mixing were range $\pm$0.1~0.15%. 4. The water level switch of electrod type used for controlling water level was found to be affective in both control performance and operation cost. 5. The water and level control system can be omitted if each tank size are standardized in accordance with greenhouse size, therefore, the installation cost might be significantly reduced. 6. The developed general controller was excellent in hardware parts, but still remained to be improved in software parts.

  • PDF

Prediction of Greenhouse Energy Loads using Building Energy Simulation (BES) (BES 프로그램을 이용한 국내 대표적 대형온실의 에너지 부하 예측)

  • Lee, Sung-Bok;Lee, In-Bok;Homg, Se-Woon;Seo, Il-Hwan;Bitog, P. Jessie;Kwon, Kyeong-Seok;Ha, Tae-Hwan;Han, Chang-Pyoung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.3
    • /
    • pp.113-124
    • /
    • 2012
  • Reliable estimation of energy load inside the greenhouse and the selection of cooling and heating facilities are very important preceding factors to save energy as well as initial and maintenance costs of operating a greenhouse. Recently, building energy simulation (BES) technique to simulate a model similar to the actual conditions through a variety of dynamic simulation methods, and predict and analyze the flow of energy is being actively introduced and developed. As a fundamental research to apply the BES technique which is mainly used for analysis of general buildings, to greenhouse, this research designed four types of naturally-ventilated greenhouses using one of commercial programs, TRNSYS, and then compared and analyzed their energy load properties, by applying meteorological data collected from six regions in Korea. When comparing the greenhouse load of each region depending on latitude and topographical characteristics through simulation, Chuncheon had nearly 9~49 % higher heating load per year than other regions, but its annual cooling load was the reverse to it. Except for Jeju, 1-2W type greenhouses in five regions showed about 17 % higher heating load than a widespan type greenhouse, and 1-2W type greenhouses in Chuncheon, Suwon, Cheongju, Daegu, Cheonju and Jeju had 23 %, 20 %, 17 %, 16 %, 18 % and 20 % higher cooling load respectively than a wide span-type one. Glasshouse and vinyl greenhouse showed 8~11 % and 10~12 % differences respectively in heating load, while 2~10 % and 7~10 % differences in cooling load respectively.

The Analysis of Contents and Evaluation on the Interior Design in Web-sites (인테리어 디자인 관련 웹 사이트의 내용분석 및 평가에 관한 연구)

  • 박현옥;이한나
    • Korean Institute of Interior Design Journal
    • /
    • no.37
    • /
    • pp.129-135
    • /
    • 2003
  • Currently, obtaining information about the interior design studies through the internet web sites is one of the outstanding mediums. Those are of the housings, architecture, interior design, furniture products, hotels and its journals, etc., and out of all those informations are the highly expected value of use. This study focuses on web-site uses in the interior designs' business. To process the study, a two-step research was executed; The step 1 was to find out the current status of web-sites by asking the each panelist to submit the monitored results after having searched and tested for more than two sites that was executed during the October, 2001. The analysis was made with the 47 sample sites selected from the monitored sites. And the step 2 was to find out the contents and evaluation factors of web-sites related the interior design. The results of the study are summarized as follows: First, the monitored Intoner design related 25 web-sites were classified into 3 groups. One group of 13 sites is identified as a remodeling/construction works, and one another with 7 sites is as shopping site, and the other with 5 sites is as a professional portal site. Second, the evaluation has been implemented which has shown 5 variables on the information searches are $\circled1$ the diversities of contents, $\circled2$ the accuracy/reliability of techniques, $\circled3$ the design of a picture and communication, $\circled4$ the convenience of link, and $\circled5$ the originality of web-site This study will provide the users with a fundamental material in evaluating the quality of interior design information on the internet web sites.

A Study on the Ornamental Representation in Contemporary Commercial Space (현대 상업공간 실내디자인에 나타나는 오나먼트의 표상성에 관한 연구)

  • Han, Hea-Shin;Kim, Moon-Duck
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.6
    • /
    • pp.133-141
    • /
    • 2009
  • Since Adolf Loos' Ornament and Crime was released, ornament had been regarded as a vice in Modern architecture. In Post Modern architecture, the ornamental vocabularies extracted from the classical architecture have been symbolically expressed. As a result, the significance of existence of and the use value of architecture have increased with improved intimacy to the public. However, many studies that have analyzed architecture in terms of semantics and semiotics focusing on communication between architecture and the public have admitted instability in architectural meaning because of the fundamental difference between architecture and language. At the same time, the architectural representation has encountered a lot of limitations along with the deconstruction and non-presentation theory in Post-Structuralism. Even under these circumstances, the ornamental representation can be a critical factor which makes communication possible while expressing spatial identity in this pluralistic contemporary society. Hence, this paper has established logical grounds for research based on theoretical investigation on the concept of representation, semiotics, and ornamental representation, with regard to spatial communication through ornamental representation in commercial space. Based on Peirce's Semiotics which is the typical theoretical science in terms of representation, this paper has analyzed the three kinds of signs (Icon, Index and Symbol) that he proposed. Peirce's classification of signs becomes ideal when the factors are well balanced, with room for combination instead of strict classification. It appears that his theory of signs would be useful in understanding and analyzing ornamental representation. This study on representational ornament could offer a plan for ideal communication and abundant spatial experience in the interior design of commercial space in which the expression of creative space identity is required.

The Influences of Mother's Psychological Characteristics on Verbal abuse of Early Children Mother's (유아 어머니의 심리적 특성이 언어적 학대에 미치는 영향)

  • Park, Dong-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4368-4379
    • /
    • 2013
  • Purpose: The purpose of this study was to identify the factors that influence verbal abuse in early childhood mothers and to examine the fitness of a path model among these variables. The goal of the study was to provide fundamental data on ways in which verbal abuse by early childhood mothers can be prevented. Methods: The data was collected by using self report questionnaires from December 7th to 25th, 2011. The subjects were 320 early childhood mothers who had children in kindergarten. In order to estimate the hypothesized model, the data was analyzed using the AMOS 18.0 programs for structural equation modeling. Results: Parenting stress, anger and anger expression demonstrated a direct effect on causing verbal abuse by early childhood mothers. This study suggest that parental education program are necessary which a early childhood mothers can be express positively about parenting stress and anger.

Modeling of Practical Photovoltaic Generation System using Controllable Current Source based Inverter (제어 가능한 전류원 기반의 인버터를 이용한 실제적 태양광 발전 시스템 모델링)

  • Oh, Yun-Sik;Cho, Kyu-Jung;Kim, Min-Sung;Kim, Ji-Soo;Kang, Sung-Bum;Kim, Chul-Hwan;Lee, You-Jin;Ko, Yun-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1340-1346
    • /
    • 2016
  • Utilization of Distributed Generations (DGs) using Renewable Energy Sources (RESs) has been constantly increasing as they provide a lot of environmental, economic merits. In spite of these merits, some problems with respect to voltage profile, protection and its coordination system due to reverse power flow could happen. In order to analyze and solve the problems, accurate modeling of DG systems should be preceded as a fundamental research task. In this paper, we present a PhotoVoltaic (PV) generation system which consists of practical PV cells with series and parallel resistor and an inverter for interconnection with a main distribution system. The inverter is based on controllable current source which is capable of controlling power factors, active and reactive powers within a certain limit related to amount of PV generation. To verify performance of the model, a distribution system based on actual data is modeled by using ElectroMagnetic Transient Program (EMTP) software. Computer simulations according to various conditions are also performed and it is shown from simulation results that the model presented is very effective to study DG-related researches.

A Study on the Systematic Construction of the Utility Space in General Hospital (국내 종합병원 Utility Space의 체계 구축에 관한 연구)

  • Kim, Eun Seok;Yang, Nae Won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.4
    • /
    • pp.77-84
    • /
    • 2017
  • Purpose: In terms of the flexibility in hospital architecture, there are fixed elements of hospital architecture: mechanical, electrical, aeration rooms and shafts, which are the main utility spaces. Thus, it is necessary to recognize the utility space as a system that helps internal functions and flexible internal changes. This study analyzes the notion of the main utility space in hospital architecture and the architectural planning features of the main utility spaces as the system in the design process of the recently built hospitals. Methods: The design factors are extracted comparing two hospitals' plans in each stage and the systematic characteristics of utility spaces are analyzed accordingly. The opinions gathered from interviews of practitioners, architects and facility planning experts directly involved in the architecture design process are analyzed and reflected in the results. Results: Planning for utility spaces should be accompanied by the architectural plan from the basic design process, and proceeded with recognizing utility spaces as a system, which is a fixed element. Utility spaces are highly organically connected. Horizontal and vertical distribution of air chambers can reduce the length and number of ducts, and thus save story height, and reduce the number of shafts, the vertical connection passage. This is advantageous in securing the variable area, which is the ultimate objective of the system-centered hospital architecture plan. Implications: Thereby aims to provide fundamental data on systematic utility space planning in the hospital architecture planning.

Study on Radial Force of Helical Structure for Biodegradable Polymer Stents (생분해성 고분자 스텐트를 위한 나선헝 구조의 팽창력 연구)

  • Park, Chul-Ho;Park, Ga-Ram;Choi, Ji-Yeon;Park, Kwi-Deok;Han, Dong-Keun
    • Polymer(Korea)
    • /
    • v.35 no.3
    • /
    • pp.260-264
    • /
    • 2011
  • Biodegradable polymeric stents have been issued to replace the existing non-degradable metal stents due to relatively improved biocompatibility and low side effects. Fundamentally, all the stents must possess the desired mechanism strength, especially, compression or radial force to maintain the diameters of expanded vessels. Therefore, this study suggests a helical structure and focused on the relation between the lateral compression and structural factors, Unlike a cylindrical model, the radial force of the helical model is proportional to the thickness and the length to the power of one, whereas the diameter to the power of 1.6. The function obtained from these results might provide the fundamental information to design and prepare the stem for clinical applications.