• Title/Summary/Keyword: Functional system

Search Result 5,153, Processing Time 0.035 seconds

A study on functional cosmetics purchasing behavior and satisfaction based on psychological characteristics post-COVID-19

  • Jang, Min-ah;Lee, Jung Min
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.313-324
    • /
    • 2022
  • This study aims to quantitatively understand the influence of changes in functional cosmetics purchasing sentiment on purchasing behavior and purchase satisfaction after the COVID-19 pandemic and present empirical analysis results regarding the rapidly changing cosmetics consumption market. This study empirically analyzed the structural relationship between non-face-to-face service purchase behavior, functional cosmetics purchase behavior, and functional cosmetics purchase satisfaction to predict purchase behavior of functional cosmetics by psychological characteristics after COVID-19. The collected data were analyzed using SPSS 22.0 (Statistical Package for Social Science) program and Amos 21.0, and correlation analysis was performed to understand the relationship between consumers' purchasing behaviors of functional cosmetics according to their perception of risk of COVID-19 carried out.Summarizing the results of this study, it was found that the higher the anxiety after the corona outbreak, the higher the non-face-to-face service purchase behavior and the functional cosmetics purchase behavior. It was found that purchase satisfaction increased when purchasing behavior of functional cosmetics increased, but purchase satisfaction decreased as anxiety increased after the outbreak of Corona.In this study, a sample of 1452 people were used as research data, and the theoretical implications for the development of functional cosmetics were presented by confirming the effect of changes in non-face-to-face service purchase behavior according to psychological characteristics after Corona 19 on consumer satisfaction.

The Assessment of the Postural Control Ability of the Volleyball Players With Functional Ankle Instability Using Balance Master System

  • Kim, Ho-Sung;Ahn, Chang-Sik;Choi, Jong-Duk
    • Physical Therapy Korea
    • /
    • v.15 no.4
    • /
    • pp.18-26
    • /
    • 2008
  • The present study was aimed at investigating the postural control ability of volleyball players with functional ankle instability. The subjects were 26 male volleyball players were divided into 2 groups (13 subjects with functional ankle instability and 13 subjects with ankle stability) who could evaluate Questionnaire. All the male participants were tested by a Balance Master System. This study were to measure of static balance ability, dynamic balance ability, motor function the difference between functional ankle instability group and control group. Ankle instability group and stable group in postural sway ($^{\circ}/sec$) on film surface with eye closed in modified clinical test sensory interaction on balance, and left unilateral stance with eye opened and closed were significantly different (p<.05). The ankle instability group and stable group in limit of stability were significantly different (p<.05). The ankle instability group and stable group in left/right rhythmic weight shirt were significantly different (p<.05). The ankle instability group and stable group in turn time (sec) & turn sway ($^{\circ}$) during step/quick turn and end sway ($^{\circ}/sec$) in tandem walk were significantly different (p<.05). This study showed that volleyball players with functional ankle in stability were effected postural control ability by static balance & dynamic balance ability. Further study is needed to measure various athletic with functional ankle instability for clinical application.

  • PDF

Comparison of the Functional Ambulation Performance Scores of Senior Adults With or Without a History of Falls (낙상 경험 유무에 따른 노인의 기능적 보행성취도 점수(FAP score) 비교)

  • Kwon, Hyuk-Cheol;Kong, Jin-Yong
    • Physical Therapy Korea
    • /
    • v.10 no.1
    • /
    • pp.1-13
    • /
    • 2003
  • The purpose of the study was to determine if there was a difference in the Functional Ambulation Performance score of senior adults with or without a history of falls during walking at a preferred velocity. Twelve subjects with a history of falling (mean age=73.8) and eight subjects with no history of falling (mean age=70.4) participated in the study. Temporal and spatial parameters of gait were analyzed using the computerized GAITRite system. The GAITRite system integrates specific components of locomotion to provide a single, numerical representation of gait, the Functional Ambulation Performance score. The Functional Ambulation Performance score is a Quantitative means of assessing gait based on specific temporal and spatial parameters. Statistical analysis of the two groups demonstrated a significant decrease in Functional Ambulation Performance score for those with a history of falls. They had lower values for step/extremity ratios, mean normalized velocity, and greater values for step times, percent in double support. These results indicate that the GAITRite system can be useful in detecting footfall patterns and selected time and distance measurements of persons with a history of falls and the Functional Ambulation Performance score can be used as indicators of gait performance for senior adults with a history of falls.

  • PDF

Functional analysis of air transport mission (항공 수송 임무의 기능 분석에 관한 연구)

  • Song, Youn-Seob
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.16 no.4
    • /
    • pp.41-48
    • /
    • 2008
  • Functional analysis of air transport mission is conducted to establish the performance requirements of the commercial transport designs. The analysis process begins by making a top-down analysis to the aircraft system level mission functions. Correctly interpreting the top-level performance requirements is the first step in designing and building an aircraft system. Each function and sub-function is allocated and examined to the aircraft level and flight operations phase to optimize the system performance and design requirements, such that these lower-level requirements can be traced back to the top-level requirements they are designed to fulfill. Special attention is given to making sure all interfaces, both internal and external, are addressed. The results are also in good resources of functional hazard assessment involved in certification processes.

  • PDF

A Study on Application of Systems Approach for Laser Micro Machining Design Process (시스템적 접근을 통한 레이저 미세가공 설계 프로세스 개발에 관한 연구)

  • Moon, Seong-Wook;Park, Young-Won;Nam, Gi-Jung
    • Laser Solutions
    • /
    • v.10 no.3
    • /
    • pp.15-24
    • /
    • 2007
  • In this paper laser micromachining system design process for commercialization is suggested. The constructed system design process is properly adjusted for laser micromachining area after tailoring engine process of system engineering process such as requirement analysis, functional analysis and allocation, system synthesis and system optimization process. In the current laser machining system design, system components and specifications are determined on the basis of experimental experience which a laser is being used in machining some materials as well as the current machining and research trend. In this paper, however, systematic process is suggested in addition to experimental experience, which the laser and system components and their specifications are decided in the process of definition of functional requirements and engine design variables of system to satisfy the customer's requirements.

  • PDF

A system measuring the functional dimension of the hand and arm (손/팔의 기능적 치수 측정시스템)

  • 이경태;강신길;박재희
    • Proceedings of the ESK Conference
    • /
    • 1996.10a
    • /
    • pp.219-224
    • /
    • 1996
  • By integrating the wired-glove and the position sensor using the magnetic fields, we developed the system which could measure the functional dimension of the hand and arm of the human. Magnetic position sensor traces the position and orientation of the arm while the wired-glove measures 18 phalangeal joint angles(including abduction between fingers, pitch and yaw of the wiist). The system could be used to monitor and quantify the functional dimension of the hand and arm and also could be used to test the product usability where the hand motion is important. Another important application lies in determining the degree of paralysis.

  • PDF

FUNDAMENTAL STUDY OF INTELLIGENT MUSTI-FUNCTIONAL INSTRUMENTATION AND ITS SIGNAL PRICESSING ABILITIES

  • Wakuya, Hiroshi;Shimoyama, Akihiko;Shida, Katsunori
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.166-169
    • /
    • 1995
  • An intelligent system which is an integration of multi-functional instrumentation (MFI) and a neural network is discussed. According to some experiments of temperature and wind velocity it is clear that this system can learn the data structure of two parameters above. So it makes good performances for estimations of non-sample data.

  • PDF

BOUNDEDNESS IN FUNCTIONAL DIFFERENTIAL SYSTEMS VIA t-SIMILARITY

  • Goo, Yoon Hoe
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.29 no.2
    • /
    • pp.347-359
    • /
    • 2016
  • In this paper, we show that the solutions to perturbed functional differential system $$y^{\prime}=f(t,y)+{\int_{t_0}^{t}}g(s,y(s),Ty(s))ds$$, have a bounded properties. To show the bounded properties, we impose conditions on the perturbed part ${\int_{t_0}^{t}}g(s,y(s),Ty(s))ds$ and on the fundamental matrix of the unperturbed system y' = f(t, y) using the notion of $t_{\infty}$-similarity.

PERIODIC SOLUTIONS OF A DISCRETE-TIME NONAUTONOMOUS PREDATOR-PREY SYSTEM WITH THE BEDDINGTON-DEANGELIS FUNCTIONAL RESPONSE

  • Dai, Binxiang;Zou, Jiezhong
    • Journal of applied mathematics & informatics
    • /
    • v.24 no.1_2
    • /
    • pp.127-139
    • /
    • 2007
  • In this paper, we investigate a discrete-time non-autonomous predator-prey system with the Beddington-DeAngelis functional response. By using the coincidence degree and the related continuation theorem as well as some priori estimates, easily verifiable sufficient criteria are established for the existence of positive periodic solutions.

Design of Gastrointestinal Diagnosis System based on Ultrasonic Response Characteristics (초음파 응답특성 분석에 의한 위장 경화 진단시스템의 설계)

  • Lim, Do-Hyung;Kim, Eun-Geun;Lee, Gyoun-Jung;Park, Won-Pil;Kim, Han-Sung;Shin, Tae-Min;Choi, Seo-Hyung;Lee, Yong-Heum
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.250-257
    • /
    • 2007
  • Functional gastrointestinal disorders affect millions of people of all age regardless of race and sex. There are, however, rare diagnostic methods for the functional gastrointestinal disorders because functional disorders show no evidence of organic and physical causes. Our research group identified recently that the gastrointestinal tract well in the patients with the functional gastrointestinal disorders becomes more rigid than healthy people when palpating the abdominal regions overlaying the gastrointestinal tract. The aim is, therefore, to develop a diagnostic method for the functional gastrointestinal disorders based on quantitative measurement of the rigidity of the gastrointestinal tract well using ultrasound technique. For this purpose, a preliminary ultrasound diagnostic system was developed and verified through phantom tests. The system consisted of transmitter, ultrasonic transducer, receiver, TGC, and CPLD, and verified via a phantom test. For the phantom test, ten soft-tissue specimens were harvested from porcine. Five of them were then treated chemically to mimic a rigid condition of gastrointestinal tract well, which was induced by functional gastrointestinal disorders. Additionally, the specimens were tested mechanically to identify if the mimic was reasonable. The customized ultrasound system was finally verified through application to human subjects with/without functional gastrointestinal disorders(Normal and Patient Groups). It was identified from the mechanical test that the chemically treated specimens were more rigid than normalspecimen. This finding was favorably compared with the result obtained from the phantom test. The phantom test also showed that ultrasound system well described the specimen geometric characteristics and detected an alteration in the specimens. The maximum amplitude of the ultrasonic reflective signal in the rigid specimens $(0.2{\pm}0.1Vp-p)$ at the interface between the fat and muscle layers was explicitly higher than that in the normal specimens $(0.1{\pm}0.0Vp-p)$ (p<0.05). Clinical tests using our customized ultrasound system for human subject showed that the maximum amplitudes of the ultrasonic reflective signals nea. to the gastrointestinal tract well for the patient group$(2.6{\pm}0.3Vp-p)$ were generally higher than those in normal group$(0.1{\pm}0.2Vp-p)$ (p<0.05). These results suggest that newly designed diagnostic system based on ultrasound technique may diagnose enough the functional gastrointestinal disorders.