• Title/Summary/Keyword: Functional force

Search Result 525, Processing Time 0.028 seconds

Equilibrium Partitioning of Nutrient Components in Functional Solvents (기능성 용매에 대한 영양성분들의 평형분배 특성)

  • Lee, Hyoung Jin;Hong, In Kwon
    • Applied Chemistry for Engineering
    • /
    • v.20 no.3
    • /
    • pp.346-350
    • /
    • 2009
  • Natural state materials contain a lot of available nutrient components. Among them, natural nutrient substances are utilized not only as the ingredient of functional foods but also as the excipients of functional cosmetics and pharmaceutic. Of these nutrient substances, solubility parameters of each components were calculated to choose the most suitable solvents for solutions. The solubility parameters for each components were composed of the dispersion contribution of the molecular attractive function, the polar contribution of the molecular attractive function and the contribution of the hydrogen bonding force. The chi parameters ($\chi_{12}$) were calculated with the information of the solubility parameter for the solute and solvent and were used as the criteria for the optimal solute-solvent pair. The optimal solvents were suggested with the numerical values of chi parameters for some amino acids.

The Effect of Task-oriented Training on Mobility Function, Postural Stability in Children with Cerebral Palsy

  • Kim, Ji-Hye;Choi, Young-Eun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.3
    • /
    • pp.79-84
    • /
    • 2017
  • PURPOSE: The purpose of this study is to examine how task-oriented training focused on lower extremity strengthening can affect mobility function and postural stability. METHODS: The study's subjects included 10 children with cerebral palsy: 7 girls and 3 boys between the ages of 4 and 9 whose Gross Motor Functional Classification System (GMFCS) level was I or II. Their functional mobility was gauged using the Gross Motor Function Measurement (GMFM), and their postural stability was evaluated using a force platform. Participants received task-oriented training focused on lower extremity strengthening for 5 weeks. The study used a paired t-test to investigate the difference in mobility function and postural stability of children with cerebral palsy before and after the lower extremity strengthening exercise. RESULTS: The GMFM dimensions D (standing) (p<.02) and E (walking) (p<.001) improved significantly between the pre-test and post-test. A significant increase in the posturographic center of pressure (CoP) shift and surface area of the CoP were found overall between the pre-test and post-test (p<.001). CONCLUSION: The present study provides evidence that an 8-week task-oriented training focused on strengthening the lower extremities is an effective and feasible strategy for improving the mobility function and postural stability of children with cerebral palsy.

Hydrogen Permeation Properties of Ni-based Amorphous Alloys Membrane (Ni-based 비정질 합금막의 수소투과 특성)

  • Seok, Song;Lee, Dock-Young;Kim, Yoon-Bae
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.1
    • /
    • pp.35-40
    • /
    • 2008
  • Ni-based amorphous alloy ribbon was prepared by a single-roller melt-spinning technique. Palladium coating was found to enhance significantly the absorption/desorption behavior of hydrogen in amorphous alloy. The hydrogen permeability of a Pd-coated $(Ni_{60}Nb_{40}){_{100-X}}$TaX(x=5, 10) amorphous alloy was examined in the temperature range of $623{\sim}773K$, comparable with those of $Pd_{60}-Cu_{40}$ alloys. The permeated hydrogen flux was increased with increasing the temperature and the difference of hydrogen pressure between the feed side and permeates side of the membrane. The Ni-based amorphous alloys were characterized by X-ray diffractometry(XRD) and differential scanning calorimetry(DSC). The morphology of surface and roughness was observed by using scanning electron microscopy(SEM) and atomic force microscopy(AFM).

Hydrogen Embrittlement and Surface Properties of Pd-coated Zr-based Amorphous Alloys (Pd 코팅된 Zr기 비정질 합금의 수소취성 및 표면특성)

  • Seok, Song;Lee, Dock-Young;Kim, Ki-Bae
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.2
    • /
    • pp.182-188
    • /
    • 2007
  • [ $Zr_{50}-Ni_{27}-Nb_{18}-Co_5$ ] amorphous alloys ribbon was prepared by a single-roller melt-spinning technique. In order to improve the hydrogen kinetics Pd-coating were carried out on each side of the amorphous ribbon. Pd prevents oxidation of Zr and catalyses the dissociation of molecular hydrogen to atomic hydrogen. In this work, the hydrogen embrittlement and surface properties on Zr-based amorphous alloys were investigated. The Zr-based amorphous alloys were characterized by X-ray diffractometry(XRD) and differential scanning calorimetry(DSC). The morphology of surface and roughness was observed by using scanning electron microscopy(SEM) and atomic force microscopy (AFM). A lattice parameter of both Pd and Zr-based amorphous alloy was increased after hydrogen permeation at 473 K. After hydrogen permeation at 473 K, some cracks were observed on the surface of Pd, which was the cause for the hydrogen embrittlement. The crystallization temperature of Zr-based amorphous alloy was decreased due to the permeated hydrogen.

Dynamic analysis of multi-functional maintenance platform based on Newton-Euler method and improved virtual work principle

  • Li, Dongyi;Lu, Kun;Cheng, Yong;Zhao, Wenlong;Yang, Songzhu;Zhang, Yu;Li, Junwei;Shi, Shanshuang
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2630-2637
    • /
    • 2020
  • The structure design of divertor Multi-Functional Maintenance Platform (MFMP) actuated by hydraulic system for China Fusion Engineering Test Reactor (CFETR) was introduced in this paper. The model of MFMP was established according to maintenance requirements. In this paper, Newton-Euler method and the improved virtual work principle were used, the equivalent driving force of each actuator was obtained through the equivalent Jacobian inverse matrix derived from velocity relationship among the components. The accuracy of the model was verified by ADAMS simulation. The stability control of the heavy-duty components driven by hydraulic cylinders based on Newton-Euler method and improved virtual work principle was established.

Efficient Adsorption of Methylene Blue from Aqueous Solution by Sulfuric Acid Activated Watermelone Rind (Citrullus lanatus)

  • Lee, Seo-Yun;Choi, Hee-Jeong
    • Applied Chemistry for Engineering
    • /
    • v.32 no.3
    • /
    • pp.348-356
    • /
    • 2021
  • The lignocellulose-based dried watermelon rind (WR) was modified with sulfuric acid, namely SWR for enhancement of methylene blue (MB) adsorption from the aqueous solution. According to FT-IR analysis, after the modification of WR with sulfuric acid, the functional groups of R-SO3H, COOH and -OH groups was formated or enhanced on the surface of the WR. Moreover, the point of zero charge (pHpzc) was changed from 6.3 to 4.1 after modification, which widened the range for adsorbing of cationic dye MB. The adsorption process of MB onto the SWR was suitable for pseudo-2nd-order and Langmuir model and the maximum adsorption capacity of Langmuir was found to be 334.45 mg/g at pH 7. In adition, the adsorption process occurs through the electrostatic interaction, hydrogen bridge formation, electron donor-acceptor relationship, and 𝜋-𝜋 electron dispersing force between functional groups on the carbon surface with MB molecules. Depending on functional groups available on the SWR surface, the MB adsorption mechanism can occur in combination with various interactions.

An Analysis of Plantar Foot Pressure Distribution and COP Trajectory Path in Lifting Posture (들기 자세에서 족저의 압력 분포와 압력중심 이동거리의 분석)

  • Lee, Myoung-Hee;Han, Jin-Tae;Bae, Sung-Soo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.1
    • /
    • pp.25-29
    • /
    • 2009
  • The purpose of this study was to investigate the effect of two different lifting posture on the plantar foot pressure, force and COP(center of pressure) trajectory path during object lifting. Fourteen healthy adults who had no musculoskeletal disorders were instructed to lift with two postures(stoop and squat) and two object weights(empty box and 10 kg box). Plantar foot pressures, forces and COP trajectory path were recorded by the F-mat system(Tekscan, Boston, USA) during object lifting with barefoot. Plantar foot surface was defined as seven regions for pressure measurement; two toe regions, three forefoot regions, one midfoot region and one heel region. Paired t-test was used to compare the outcomes of peak pressure and maximum force with different two lifting postures and two object weights. Plantar peak pressure and maximum force under hallux was significantly greater in squat posture than stoop posture during the two different boxes lifting(p<.05). During the empty box lifting, maximum force under lessor toes was significantly less and plantar peak pressure under second metatarsal region was significantly greater in squat than stoop(p<.05). Maximum force under heel was significantly less in squat than stoop posture during 10kg box lifting(p<.05). Finally, COP trajectory path was significantly greater in squat than stoop(p<.05). These findings confirm that there are significantly change in the structure and function of the foot during the object lifting with different posture. Future studies should focus on the contribution of both structural and functional change to the development of common foot problems in adults.

The Effect of Genu Valgum on the Body Mass Index, Moment of Lower Limb Joints, Ground Reaction Force (신체질량지수, 하지관절의 모멘트, 지면반발력이 무릎외반슬에 미치는 영향)

  • Lee, Yong-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.3
    • /
    • pp.257-263
    • /
    • 2015
  • Objective : The purpose of this study was to investigate the effect of genu valgum on the body mass index, movement of lower limb joints, and ground reaction force. Methods : Gait patterns of 30 college students with genu valgum were analyzed and the static Q angle of the femur was measured for selecting genu valgum of the subjects. To analyze the kinetic changes during walking, the six-camera Vicon MX motion analysis system was used. The subjects were asked to walk 12 meters using the more comfortable walking method for walking. After they walked 12 meters more than 10 times, their most natural walking patterns were chosen three times and analyzed. Results : As a result of measuring a relationship between genu valgum and Q-angle, as the Q-angle increases, it showed a genu valgum also increased. Body Mass Index showed a significant difference between the groups was higher in the genu valgum group.(p<.001). The analysis result showed that genu valgum had a significant effect on the internal rotation moment in the hip joint(p<.05). Also, genu valgum had a significant effect on the internal rotation moment of the knee joint(p<.05). The comparative analysis of the Medial-Lateral ground reaction force in the genu valgum group showed a tendency to increase the medial ground reaction force(p<.05). The vertical ground reaction forces of the middle of the stance phase(Fz0) showed a significant increase in genu valgum group(p<.05), in particular the results showed a decrease in the early stance phase(p<.001). Conclusion : In conclusion, the change in body mass is considered to be made by proactive regular exercise for improvement of the genu valgum. In addition, the prevention of the deformation caused by secondary of the genu valgum in this study may be used as an indicator of the position alignment rehabilitation for structural and functional improvements. Applying a therapeutic exercise program for the next lap will require changes in posture alignment.

An Empirical Study on Air Force Mechanic Parka to Improve the Functionality (공군 정비파카의 기능성 개선을 위한 실태조사)

  • Lee, Sung-Ji;Nam, Yun-Ja;Choi, Hee-Eun;Cho, Young-Lim
    • Fashion & Textile Research Journal
    • /
    • v.13 no.5
    • /
    • pp.759-768
    • /
    • 2011
  • This study is designed to understand current wearing conditions of air force mechanic parkas and evaluate their functionality by examining the wearing conditions and wearers' subjective assessment. By doing so, it also intends to identify issues that require improvements; and to provide basic data for future development of air force mechanic parkas. A survey was conducted as a study methodology, and the collected 1,628 questionnaires were analyzed. Findings of this study are as follows. 1. In the usability assessment, it was found that visibility of body sides was needed to be enhanced since reflective tapes were attached only to the front and back of the body; pockets were too big, but not convenient to keep mechanic tools; the design of hiding hood was not suitable for water-proof clothing; and a new design of size-controllable hood was called for since the hood blocked eye sight. With respect to the fabric, dissatisfaction was identified with durability, cold-proof and fire-proof features. 2. In the mobility assessment, respondents showed low satisfaction with collar heights and neck girths. Mobility score was over moderate level on average, except the parka length that obstructs wearers' movement, and neck and collar size. 3. In the wearability assessment, respondents presented moderate satisfaction with pleasantness, weight, pressure and dampness. However, insulation was found unsatisfactory. Based on the result, this study proposed improvement plans on design, pattern and fabric; and is expected to serve as basic data for developing more effective and functional air force mechanic parkas.

Comparison of Mechanical Allodynia and Recovery of Locomotion and Bladder Function by Different Parameters of Low Thoracic Spinal Contusion Injury in Rats

  • Carter, Michael W.;Johnson, Kathia M.;Lee, Jun Yeon;Hulsebosch, Claire E.;Gwak, Young Seob
    • The Korean Journal of Pain
    • /
    • v.29 no.2
    • /
    • pp.86-95
    • /
    • 2016
  • Background: The present study was designed to examine the functional recovery following spinal cord injury (SCI) by adjusting the parameters of impact force and dwell-time using the Infinite Horizon (IH) impactor device. Methods: Sprague-Dawley rats (225-240 g) were divided into eight injury groups based on force of injury (Kdyn) and dwell time (seconds), indicated as Force-Dwell time: 150-4, 150-3, 150-2, 150-1, 150-0, 200-0, 90-2 and sham controls, respectively. Results: After T10 SCI, higher injury force produced greater spinal cord displacement (P < 0.05) and showed a significant correlation (r = 0.813) between the displacement and the force (P < 0.05). In neuropathic pain-like behavior, the percent of paw withdrawals scores in the hindpaw for the 150-4, 150-3, 150-2, 150-1 and the 200-0 injury groups were significantly lowered compared with sham controls (P < 0.05). The recovery of locomotion had a significant within-subjects effect of time (P < 0.05) and the 150-0 group had increased recovery compared to other groups (P < 0.05). In addition, the 200-0 and the 90-2 recovered significantly better than all the 150 kdyn impact groups that included a dwell-time (P < 0.05). In recovery of spontaneous bladder function, the 150-4 injury group took significantly longer recovery time whereas the 150-0 and the 90-2 groups had the shortest recovery times. Conclusions: The present study demonstrates SCI parameters optimize development of mechanical allodynia and other pathological outcomes.