• Title/Summary/Keyword: Function model

Search Result 12,784, Processing Time 0.039 seconds

A Graph Layout Algorithm for Scale-free Network (척도 없는 네트워크를 위한 그래프 레이아웃 알고리즘)

  • Cho, Yong-Man;Kang, Tae-Won
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.34 no.5_6
    • /
    • pp.202-213
    • /
    • 2007
  • A network is an important model widely used in natural and social science as well as engineering. To analyze these networks easily it is necessary that we should layout the features of networks visually. These Graph-Layout researches have been performed recently according to the development of the computer technology. Among them, the Scale-free Network that stands out in these days is widely used in analyzing and understanding the complicated situations in various fields. The Scale-free Network is featured in two points. The first, the number of link(Degree) shows the Power-function distribution. The second, the network has the hub that has multiple links. Consequently, it is important for us to represent the hub visually in Scale-free Network but the existing Graph-layout algorithms only represent clusters for the present. Therefor in this thesis we suggest Graph-layout algorithm that effectively presents the Scale-free network. The Hubity(hub+ity) repulsive force between hubs in suggested algorithm in this thesis is in inverse proportion to the distance, and if the degree of hubs increases in a times the Hubity repulsive force between hubs is ${\alpha}^{\gamma}$ times (${\gamma}$??is a connection line index). Also, if the algorithm has the counter that controls the force in proportion to the total node number and the total link number, The Hubity repulsive force is independent of the scale of a network. The proposed algorithm is compared with Graph-layout algorithm through an experiment. The experimental process is as follows: First of all, make out the hub that exists in the network or not. Check out the connection line index to recognize the existence of hub, and then if the value of connection line index is between 2 and 3, then conclude the Scale-free network that has a hub. And then use the suggested algorithm. In result, We validated that the proposed Graph-layout algorithm showed the Scale-free network more effectively than the existing cluster-centered algorithms[Noack, etc.].

Investigation of O4 Air Mass Factor Sensitivity to Aerosol Peak Height Using UV-VIS Hyperspectral Synthetic Radiance in Various Measurement Conditions (UV-VIS 초분광 위성센서 모의복사휘도를 활용한 다양한 관측환경에서의 에어로솔 유효고도에 대한 O4 대기질량인자 민감도 조사)

  • Choi, Wonei;Lee, Hanlim;Choi, Chuluong;Lee, Yangwon;Noh, Youngmin
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_1
    • /
    • pp.155-165
    • /
    • 2020
  • In this present study, the sensitivity of O4 Air Mass Factor (AMF) to Aerosol Peak Height (APH) has been investigated using radiative transfer model according to various parameters(wavelength (340 nm and 477 nm), aerosol type (smoke, dust, sulfate), aerosol optical depth (AOD), surface reflectance, solar zenith angle, and viewing zenith angle). In general, it was found that O4 AMF at 477 nm is more sensitive to APH than that at 340 nm and is stably retrieved with low spectral fitting error in Differential Optical Absorption Spectroscopy (DOAS) analysis. In high AOD condition, sensitivity of O4 AMF on APH tends to increase. O4 AMF at 340 nm decreased with increasing solar zenith angle. This dependency isthought to be induced by the decrease in length of the light path where O4 absorption occurs due to the shielding effect caused by Rayleigh and Mie scattering at high solar zenith angles above 40°. At 477 nm, as the solar zenith angle increased, multiple scattering caused by Rayleigh and Mie scattering partly leads to the increase of O4 AMF in nonlinear function. Based on synthetic radiance, APHs have been retrieved using O4 AMF. Additionally, the effect of AOD uncertainty on APH retrieval error has been investigated. Among three aerosol types, APH retrieval for sulfate type is found to have the largest APH retrieval error due to uncertainty of AOD. In the case of dust aerosol, it was found that the influence of AOD uncertainty is negligible. It indicates that aerosol types affect APH retrieval error since absorption scattering characteristics of each aerosol type are various.

A study on U.K.:s design education program of the Primary school (Centered on analysing program of study in the National curicurrum) (영국의 초등학교 디자인교육 프로그램에 관한 연구 -국가교육과정 학습프로그램 분석을 중심으로-)

  • Son, Yeoun-Suck
    • Archives of design research
    • /
    • v.18 no.2 s.60
    • /
    • pp.243-254
    • /
    • 2005
  • Great Britain and the United States and Finland are having an interest in long policy subject about child design education through early design education. And they approaches and practices it systematically. The research about the design learning program instance of advanced nation of primary school's design education for various objective is necessary for use with the fundamental reference data for an elementary design education. And so, This research presented the program instance investigation and analysis result of British primary school's design education. U.K is teaching an primary design education from two subjects of Art & Design and Design and Technology which is a legal subject with national curriculum. The analysis result of design relation unit learning program of two subjects is: Design relation unit learning programs of 'Design and Technology' subject's 20 unit which except 4 food relation unit is largely scientific engineering contents that include utility function contents in part. The reason is as behavior styles based on Design process solve problems scientifically & rationally. Design relation 6 units in subject of Art & Design which except the units which relates with the pure fine arts and architecture in 19 units is aesthetic-symbolic and utility-functional contents largely. And so, the result was analyzed about relation of scientific-engineering content of 'Arts & Design' subject is insufficient comparing with 'Design and Technology' subject Specially, I think that the design relation's unit learning program instances of 'Design and Technology' subject of the British primary school which have been presented by this research paper is a possibility becoming one reference model for a program development. And so I expects that this research could be applied in the program development for the primary design education of primary teacher & education agency.

  • PDF

A study on the implementation of Medical Telemetry systems using wireless public data network (무선공중망을 이용한 의료 정보 데이터 원격 모니터링 시스템에 관한 연구)

  • 이택규;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.278-283
    • /
    • 2000
  • As information communication technology developed we could check our blood pressure, pulsation electrocardiogram, SpO2 and blood test easily at home. To check our health at ordinary times is able though interlocking the house medical instrument with the wireless public data network This service will help the inconvenience to visit the hospital everytime and will save the individual's time and cost. In each house an organism data which is detected from the human body will be transmitted to the distance hospital and will be essentially applied through wireless public data network The medical information transmit system is utilized by wireless close range network It would transmit the obtained organism signal wirelessly from the personal device to the main center system in the hospital. Remote telemetry system is embodied by utilizing wireless media access protocol. The protocol is embodied by grafting CSMA/CA(Carrier Sense Multiple Access with Collision Avoidance) protocol falling mode which is standards from IEEE 802.11. Among the house care telemetry system which could measure blood pressure, pulsation, electrocardiogram, SpO2 the study embodies the ECC(electrocardiograph) measure part. It within the ECC function into the movable device and add 900㎒ band wireless public data interface. Then the aged, the patients even anyone in the house could obtain ECG and keep, record the data. It would be essential to control those who had a health-examination heart diseases or more complicated heart diseases and to observe the latent heart disease patient continuously. To embody the medical information transmit system which is based on wireless network. It would transmit the ECG data among the organism signal data which would be utilized by wireless network modem and NCL(Native Control Language) protocol to contact through wireless network Through the SCR(Standard Context Routing) protocol in the network it will be connected to the wired host computer. The computer will check the recorded individual information and the obtained ECC data then send the correspond examination to the movable device. The study suggests the medical transmit system model utilized by the wireless public data network.

  • PDF

Effect of Ischemic Preconditioning on the Oxygen Free Radical Production in the Post-ischemic Reperfused Heart

  • Park, Jong-Wan;Kim, Young-Hoon;Uhm, Chang-Sub;Bae, Jae-Moon;Park, Chan-Woong;Kim, Myung-Suk
    • The Korean Journal of Pharmacology
    • /
    • v.30 no.3
    • /
    • pp.321-330
    • /
    • 1994
  • The protective effect of 'ischemic preconditioning (PC)' on ischemia-reperfusion injury of heart has been reported in various animal species, but without known mechanisms in detail. In an attempt to investigate the cardioprotective mechanism of PC, we examined the effects of PC on the myocardial oxidative injuries and the oxygen free radical production in the ischemia-reperfusion model of isolated Langendorff preparations of rat hearts. PC was performed with three episodes of 5 min ischemia and 5 min reperfusion before the induction of prolonged ischemia (30 min)-reperfusion(20 min). PC prevented the depression of cardiac function (left ventricular pressure x heart rate) observed in the ischemic-reperfused heart, and reduced the release of lactate dehydrogenase during the reperfusion period. On electron microscopic pictures, myocardial ultrastructures were relatively well preserved in PC hearts as compared with non-PC ischemic-reperfused hearts. In PC hearts, lipid peroxidation of myocardial tissue as estimated from malondialdehyde production was markedly reduced. PC did not affect the activity of xanthine oxidase which is a major source of oxygen radicals in the ischemic rat hearts, but the myocardial content of hypoxanthine (a substrate for xanthine oxidase) was much lower in PC hearts. It is suggested from these results that PC brings about significant myocardial protection in ischemic-reperfused heart and this effect may be related to the suppression of oxygen free radical reactions.

  • PDF

Serum Tumor Marker Levels might have Little Significance in Evaluating Neoadjuvant Treatment Response in Locally Advanced Breast Cancer

  • Wang, Yu-Jie;Huang, Xiao-Yan;Mo, Miao;Li, Jian-Wei;Jia, Xiao-Qing;Shao, Zhi-Min;Shen, Zhen-Zhou;Wu, Jiong;Liu, Guang-Yu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.11
    • /
    • pp.4603-4608
    • /
    • 2015
  • Background: To determine the potential value of serum tumor markers in predicting pCR (pathological complete response) during neoadjuvant chemotherapy. Materials and Methods: We retrospectively monitored the pro-, mid-, and post-neoadjuvant treatment serum tumor marker concentrations in patients with locally advanced breast cancer (stage II-III) who accepted pre-surgical chemotherapy or chemotherapy in combination with targeted therapy at Fudan University Shanghai Cancer Center between September 2011 and January 2014 and investigated the association of serum tumor marker levels with therapeutic effect. Core needle biopsy samples were assessed using immunohistochemistry (IHC) prior to neoadjuvant treatment to determine hormone receptor, human epidermal growth factor receptor 2(HER2), and proliferation index Ki67 values. In our study, therapeutic response was evaluated by pCR, defined as the disappearance of all invasive cancer cells from excised tissue (including primary lesion and axillary lymph nodes) after completion of chemotherapy. Analysis of variance of repeated measures and receiver operating characteristic (ROC) curves were employed for statistical analysis of the data. Results: A total of 348 patients were recruited in our study after excluding patients with incomplete clinical information. Of these, 106 patients were observed to have acquired pCR status after treatment completion, accounting for approximately 30.5% of study individuals. In addition, 147patients were determined to be Her-2 positive, among whom the pCR rate was 45.6% (69 patients). General linear model analysis (repeated measures analysis of variance) showed that the concentration of cancer antigen (CA) 15-3 increased after neoadjuvant chemotherapy in both pCR and non-pCR groups, and that there were significant differences between the two groups (P=0.008). The areas under the ROC curves (AUCs) of pre-, mid-, and post-treatment CA15-3 concentrations demonstrated low-level predictive value (AUC=0.594, 0.644, 0.621, respectively). No significant differences in carcinoembryonic antigen (CEA) or CA12-5 serum levels were observed between the pCR and non-pCR groups (P=0.196 and 0.693, respectively). No efficient AUC of CEA or CA12-5 concentrations were observed to predict patient response toward neoadjuvant treatment (both less than 0.7), nor were differences between the two groups observed at different time points. We then analyzed the Her-2 positive subset of our cohort. Significant differences in CEA concentrations were identified between the pCR and non-pCR groups (P=0.039), but not in CA15-3 or CA12-5 levels (p=0.092 and 0.89, respectively). None of the ROC curves showed underlying prognostic value, as the AUCs of these three markers were less than 0.7. The ROC-AUCs for the CA12-5 concentrations of inter-and post-neoadjuvant chemotherapy in the estrogen receptor negative HER2 positive subgroup were 0.735 and 0.767, respectively. However, the specificity and sensitivity values were at odds with each other which meant that improving either the sensitivity or specificity would impair the efficiency of the other. Conclusions: Serum tumor markers CA15-3, CA12-5, and CEA might have little clinical significance in predicting neoadjuvant treatment response in locally advanced breast cancer.

Study of Motion-induced Dose Error Caused by Irregular Tumor Motion in Helical Tomotherapy (나선형 토모테라피에서 불규칙적인 호흡으로 발생되는 움직임에 의한 선량 오차에 대한 연구)

  • Cho, Min-Seok;Kim, Tae-Ho;Kang, Seong-Hee;Kim, Dong-Su;Kim, Kyeong-Hyeon;Cheon, Geum Seong;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.119-126
    • /
    • 2015
  • The purpose of this study is to analyze motion-induced dose error generated by each tumor motion parameters of irregular tumor motion in helical tomotherapy. To understand the effect of the irregular tumor motion, a simple analytical model was simulated. Moving cases that has tumor motion were divided into a slightly irregular tumor motion case, a large irregular tumor motion case and a patient case. The slightly irregular tumor motion case was simulated with a variability of 10% in the tumor motion parameters of amplitude (amplitude case), period (period case), and baseline (baseline case), while the large irregular tumor motion case was simulated with a variability of 40%. In the phase case, the initial phase of the tumor motion was divided into end inhale, mid exhale, end exhale, and mid inhale; the simulated dose profiles for each case were compared. The patient case was also investigated to verify the motion-induced dose error in 'clinical-like' conditions. According to the simulation process, the dose profile was calculated. The moving case was compared with the static case that has no tumor motion. In the amplitude, period, baseline cases, the results show that the motion-induced dose error in the large irregular tumor motion case was larger than that in the slightly irregular tumor motion case or regular tumor motion case. Because the offset effect was inversely proportion to irregularity of tumor motion, offset effect was smaller in the large irregular tumor motion case than the slightly irregular tumor motion case or regular tumor motion case. In the phase case, the larger dose discrepancy was observed in the irregular tumor motion case than regular tumor motion case. A larger motion-induced dose error was also observed in the patient case than in the regular tumor motion case. This study analyzed motion-induced dose error as a function of each tumor motion parameters of irregular tumor motion during helical tomotherapy. The analysis showed that variability control of irregular tumor motion is important. We believe that the variability of irregular tumor motion can be reduced by using abdominal compression and respiratory training.

In Vitro Evaluation of Shear Bond Strengths of Zirconia Cerami with Various Types of Cement after Thermocycling on Bovine Dentin Surface (지르코니아 표면 처리와 시멘트 종류에 따른 치면과의 전단 결합 강도 비교 연구)

  • Cho, Soo-Hyun;Cho, In-Ho;Lee, Jong-Hyuk;Nam, Ki-Young;Kim, Jong-Bae;Hwang, Sang-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.3
    • /
    • pp.249-257
    • /
    • 2007
  • State of problem : The use of zirconium oxide all-ceramic material provides several advantages, including a high flexural strength(>1000MPa) and desirable optical properties, such as shading adaptation to the basic shades and a reduction in the layer thickness. Along with the strength of the materials, the cementation technique is also important to the clinical success of a restoration. Nevertheless, little information is available on the effect of different surface treatments on the bonding of zirconium high-crystalline ceramics and resin luting agents. Purpose : The aim of this study was to test the effects of surface treatments of zirconium on shear bond strengths between bovine teeth and a zirconia ceramic and evaluate differences among cements Material and methods : 54 sound bovine teeth extracted within a 1 months, were used. They were frozen in distilled water. These were rinsed by tap water to confirm that no granulation tissues have left. These were kept refrigerated at $4^{\circ}C$ until tested. Each tooth was placed horizontally at a plastic cylinder (diameter 20mm), and embedded in epoxy resin. Teeth were sectioned with diamond burs to expose dentin and grinded with #600 silicon carbide paper. To make sure there was no enamel left, each was observed under an optical microscope. 54 prefabricated zirconium oxide ceramic copings(Lava, 3M ESPE, USA) were assigned into 3 groups ; control, airborne-abraded with $110{\mu}m$ $Al_2O_3$ and scratched with diamond burs at 4 directions. They were cemented with a seating force of 10 ㎏ per tooth, using resin luting cement(Panavia $F^{(R)}$), resin cement(Superbond $C&B^{(R)}$), and resin modified GI cement(Rely X $Luting^{(R)}$). Those were thermocycled at $5^{\circ}C$ and $55^{\circ}C$ for 5000 cycles with a 30 second dwell time, and then shear bond strength was determined in a universal test machine(Model 4200, Instron Co., Canton, USA). The crosshead speed was 1 mm/min. The result was analyzed with one-way analysis of variance(ANOVA) and the Tukey test at a significance level of P<0.05. Results : Superbond $C&B^{(R)}$ at scratching with diamond burs showed the highest shear bond strength than others (p<.05). For Panavia $F^{(R)}$, groups of scratching and sandblasting showed significantly higher shear bond strength than control group(p<.05). For Rely X $Luting^{(R)}$, only between scratching & control group, significantly different shear bond strength was observed(p<.05). Conclusion : Within the limitation of this study, Superbond $C&B^{(R)}$ showed clinically acceptable shear bond between bovine teeth & zirconia ceramics regardless of surface treatments. For the surface treatment, scratching increased shear bond strength. Increase of shear bond strength by sandblasting with $110{\mu}m$ $Al_2O_3$ was not statistically different.

Comparison of the Strain on the Alveolar Ridge According to the Occlusal Scheme of Complete Dentures (총의치 교합양식에 따른 응력 분포 양상 비교연구)

  • Choi, Won-Jun;Lim, Young-Jun;Kim, Chang-Whe;Kim, Myung-Joo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.1-12
    • /
    • 2010
  • The purpose of this study was to compare the strain on the alveolar ridge in the centric, eccentric and protrusive position according to the occlusal scheme (bilateral balanced occlusion with 33 degree anatomical teeth, group B; monoplane occlusion with non-anatomical teeth, group M; lingualized occlusion with 33 degree anatomical teeth and non-anatomical teeth, group L; of complete dentures. Experimental dentures were set bilateral balanced occlusion, lingualized occlusion and monoplane occlusion. They are analysed through T-Scan II(Tekscan, Boston, U.S.A) and 1.5mm thick layer was removed from the denture-supporting surface of resin model and then replaced with silicone to simulate resilient edentulous ridge mucosa. A $4{\times}6$ linear strain gauge is attached to the $1^{st}$ premolar and $1^{st}$ molar area. The strain values are recorded according to the occlusal scheme in the centric, eccentric and protrusive position after uniformly applying 50 N and 150 N force through a Universal Testing Machine(instron$^{(R)}$ 5567, Bluehill 2.0 software ,U.S.A.) with the models mounted in the articulator. When performing centric and protrusive occlusion, the three groups of occlusal scheme were compared in the anterior region and in the posterior region. The strains of each group were also compared in the working side and in the non-working side during eccentric excursion. It was observed that the strain in the bilateral balanced occlusion showed a higher value than the lingualized occlusion and monoplane occlusion in every position except the non-working side. However, during the eccentric movement the strain value in the non-working side showed the lowest value in the bilaterally balanced occlusion. The strain change amount from the working side or centric occlusion to non-working side and also the strain variation rate within the non-working side showed the highest value in bilateral balanced occlusion.

The Effect of Heat Co-treatment on Acute Lung Injury of the Rat Induced by Intratracheal Lipopolysaccharide (내독소 투여 직후 가해진 열충격이 백서의 급성폐손상에 미치는 영향)

  • Na, Joo Ock;Shim, Tae Sun;Lim, Chae-Man;Lee, Sang Do;Kim, Woo Sung;Kim, Dong Soon;Kim, Won Dong;Koh, Younsuck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.4
    • /
    • pp.355-366
    • /
    • 2002
  • Background : The heat shock protein (HSP) 70 families are known to protect cells against the irreversible tissue injury induced by stress and to induce the recovery of cell function during stress. Heat pretreatment was reported to decrease the acute lung injury (ALI) of rats induced by lipopolysaccharide (LPS). However, the role of heat shock with LPS co-treatmenton ALI is unclear. The purpose of this study was to investigate the effect of heat treatment, which was given immediately after the beginning of ALI induced by LPS intratracheally administered in rats. Methods : Either saline (saline group) or LPS was intratracheally instilled without heat treatment (LPS group). In addition, heat was conducted 18 hours prior to the instillation of LPS (pre-treatment group) and conducted immediately after instillation of LPS (co-treatment group). Six hours after the LPS or saline treatment, blood, bronchoalveolar lavage (BAL) fluid and lung tissue samples were obtained. The myeloperoxidase (MPO) activity and the heat shock protein expression in the lung tissue, the differential counts of the polymorphonuclear leukocytes (PMN) in the BAL fluids, and the LDH, protein, $IL-1{\beta}$, $TNF-{\alpha}$ and IL-10 levels in BAL fluid and serum were measured. Results : 1) The MPO activity, the differential PMN counts in the BAL fluid, BAL fluid and serum cytokines were higher in the LPS, the heat pre-treatment and co-treatment group than those of the saline group (p value <0.05). 2) The MPO activity and the protein level in the BAL fluid from the heat co-treatment group were similar to those of the LPS group. 3) The serum $TNF-{\alpha}$ level of the heat co-treatment group was significantly higher than that of the LPS group (p=0.01). Conclusion : Heat shock response administered immediately after a LPS instillation did not attenuate the ALI in this model.