• 제목/요약/키워드: Function Observer

검색결과 230건 처리시간 0.031초

현대건축에서 그리드와 축에 관한 연구 -듀랑에서부터 르 코르뷔제까지- (The Grid and Axis in Modern Architecture From Durand to Le Corbusier)

  • 배형민
    • 건축역사연구
    • /
    • 제11권4호
    • /
    • pp.99-115
    • /
    • 2002
  • Centered on Durand and Le Corbusier, this study analyses the changing status of the grid and axis in modern architecture. In the Renaissance, the taxis grid operated as a contour grid, defining the elements and space of the building as part of closed harmonized world. In his Pre'cis des lec., ons d'architecture, Durand provides the most explicit demonstration of a new modem grid in which its lines function as spatial and structural axes. In principle these axes are coordinates for the placements of a priori elements but in Beaux-Arts practice, as Durand himself acknowledged, they involve a simultaneous process in which the spatial axis sets up the basic parti and the structural axis is developed into the building's poche'. As a coordinate, Durand's grid provides a place for the 'subject' to enter the architectural process. At the same time, it is the object of the subject's gaze, the dense site of the subject's transformative actions. Though Le Corbusier is noted for his frequent attacks on the academic system, his architecture should be seen within the continuity of the classical tradition. He redefines the Beaux-Arts axis as a moving and seeing observer, and continues the discipline of the plan, the essential discipline of the Beaux-Arts system. In his dialectics, an intellectual scheme which extends to his commentators, the intention and will of the subject must come in tune with the objective material form of the building. Like Durand, Le Corbusier's axis provides the medium for the subject to enter. Unlike the Beaux-Arts system, however, Le Corbusier's mobile subject no longer has a holistic view of the building previously provided by the central axis. If there is a parti for Le Corbusier, it consists of the domino grid as a potential, but nonetheless, tangible form. In comparison with the Beaux-Arts structural grid, his gaze no longer lingers on their lines because they no longer constitute a formal process tied to the development of a thick articulated structure. Le Corbusier's grid constitutes a 'loose' form, one that breaks down the hierarchical nature of the Beaux-Arts system.

  • PDF

건조정도에 따른 자연치아의 색조비교 (Comparison of Shade Changes According to Dry/Wet Condition of Tooth using Intra-Oral Colorimeter)

  • 최미라
    • 구강회복응용과학지
    • /
    • 제26권3호
    • /
    • pp.265-271
    • /
    • 2010
  • 심미적 보철물을 제작하는 데 있어 색조의 선택은 중요한 단계이다. 이러한 색조선택과정은 광원, 표면, 관찰자 의 능력, 주변 배경색상, 관찰각도, 명암적응력 등과 같은 다양한 원인에 의해 좌우된다. 색조를 선택하는 시점에 따라 치아의 건조정도는 달라지게 되므로 본 실험에서는 치아 건조정도가 자연치아의 색조에 미치는 영향에 대해 살펴보고자 하였다. 구강내 색조측정기를 이용하여 구강가글 즉시 측정한 군을 실험군으로 구강가글 10초 후, 1분 후, 5분 후, 30초간 건조 후 색조를 측정하여 ${\Delta}E$값을 비교하였다. 각 실험군사이 ${\Delta}E$값은 유의할 만한 차이를 보였으나 대부분의 경우 구강내에서 시각적으로 구별할 수 없는 정도의 근접치를 보였다. 실험결과 시각적인 방법으로 색조 견본을 이용하는 방법은 건조정도에 따른 색조 차이가 없는 것으로 사료되고 기계를 이용하는 경우 건조정도가 색조 선택에 유의할 만한 영향을 줄 것이라고 사료된다.

Automatic $St{\ddot{o}}ckigt$ Sizing Test Using Hue Value Variation of a Droplet

  • Kim, Jae-Ok;Kim, Chul-Hwan;Lee, Young-Min;Kim, Gyeong-Yun;Shin, Tae-Gi;Park, Chong-Yawl
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2006년도 PAN PACIFIC CONFERENCE vol.2
    • /
    • pp.227-230
    • /
    • 2006
  • The $St{\ddot{o}}ckigt$ sizing test of the most-commonly used sizing tests is easily influenced by the individual testers' bias in recognizing red coloration. Therefore the test had to be modified to improve its reliability and reproducibility by automated recognition of a coloration procedure during testing. In order to achieve this, all measured variables occurring during the $St{\ddot{o}}ckigt$ test was first be analyzed and then reflected in the new automatic system. Secondly, the most important principle applied was to transform the RGB values of the droplet image to hue (H), saturation (S) and value (V) respectively. This is because RGB cannot be used as a color standard, owing to RGB's peculiarity of being seriously affected by the observer's point of view. Therefore, the droplet color had to be separated into three distinct factors, namely the HSV values, in order to allow linear analysis of the droplet color. When the average values of the vectors calculated during color variation from yellow to brown were plotted against time, it was possible to determine the vector value of hue, the most sensitive factor among HSV, at the specific time by differentiation of a function when it exceeds the critical point. Then, the specific time consumed up to the critical point was regarded as the $St{\ddot{o}}ckigt$ sizing degree. The conventional method took more time to recognize an ending point of coloration than the automatic method, and in addition the error ranges of the conventional sizing degrees on the specific addition points of AKD were wider than those of the automatic method.

  • PDF

스테레오 카메라를 이용한 3차원 정보의 가시화 (Visualization of The Three Dimensional Information Using Stereo Camera)

  • 이남호;박순용;이승민
    • 전자공학회논문지SC
    • /
    • 제47권4호
    • /
    • pp.15-20
    • /
    • 2010
  • 스테레오 카메라에 의해 취득된 대상물체의 좌, 우 영상을 이용하여 3차원 형상 정보를 추출하여 가시화 하는 기법 및 주시 각 제어 알고리즘을 적용하여 입체감 있는 영상으로 출력하는 기술에 관한 연구이다. 효율적인 3차원 형상 정보 추출을 위해, 카메라 렌즈의 왜곡 보정 및 에너지 함수를 적용한 정합을 실시하였다. 특히, 다 방향 시차영상에 정합선 최적화 기법을 적용하여 정합 방향에 따른 다방향성 방법과 신뢰확장 방법의 약점을 보완하였다. 정합된 관심영역에 대한 3차원 형상정보를 VRML(virtual reality modeling language)을 사용하여 나타내었고, 주시각 제어를 통하여 입체감 있는 영상을 출력하였다. 이는 관측자에게 보다 향상된 3차원 정보를 제공할 수 있을 것이다.

구내용 분광광도계를 이용한 자연치의 색상분석 (COLOR ANALYSIS OF THE NATURAL TEETH WITH A MODIFIED INTRAORAL SPECTROPHOTOMETER)

  • 조경모;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.223-235
    • /
    • 1998
  • The recognition of the esthetics as well as their function of the teeth in the dental field is growing. Evaluating the esthetics of a tooth concerns shape, texture, and color. And among these, color has been the most difficult element to make natural expression. Color is a very subjective element affected by many different factor like light source, object, observer. Numerous efforts to quantifying color has been made. Currently the use of colorimeter and spectrophotometercolor that the color measuring device has been suggested. In this study, the normal range of the tooth color in canines, lateral incisors and central incisors for Koreans was evaluated with a modified spectrophotometer for intraoral use. The color differences in terms of teeth positions, age and area within the tooth was evaluated and comparatively analyzed. Results were as follow ; 1. In all age groups, the central incisors are most bright and least yellowish opposit to the canines are most dark and yellowish. The central incisors and lateral incisors showed the similar color patterns. 2. In the comparison between gender, it showed that in the 10' s group male have more yellowish, the 20's female have lighter and more redness, the 30's indicated more redness in female and in the 40's the lightness is more in female. 3. With aging, there was no significant change in $L^*$ and $a^*$ coordinates but a shift was in $b^*$ to yellowish in the 30' sand 40's in central incisors. Lateral incisors and canines showed a lighter and more yellowish tooth color with an irregular change of color coordinate in $a^*$. 4. In all teeth the middle and cervical portion showed close correlation with over 0.7(0.05>p) but color ($a^*$, $b^*$) showed higher correlation than lightness($L^*$). 5. It has been shown that through the regression test the cervical color could be calculated by the middle color value.

  • PDF

Effects of Myofascial Release and Posture Correction Exercise on the Neck Movement and the Quality of Sleep in Patients with Chronic Tension-Type Headaches

  • Cho, Sunghak
    • 국제물리치료학회지
    • /
    • 제10권4호
    • /
    • pp.1897-1902
    • /
    • 2019
  • Background: Tension-type headaches, which make up the highest proportion of headaches, are prone to develop into chronic tension-type headaches (CTTH). The characteristic of CTTH in patients is that the active myofascial trigger point (ATrP) which causes pain in the muscles of the back of the head is increased, compared to the normal headache and moves the head position forward. Objective: The aim of this study was to investigate the effects of myofascial release (MFR) and posture correction in effectively improving neck function and sleep quality in the symptoms of CTTH patients. Design: Observer-blind study Methods: To reduce ATrP, MFR was applied and exercise was also applied to correct posture. The subjects of this study were 48 individuals randomly divided into three groups; The MFR group using the MFR technique; The MFR with exercise group subject to both the MFR technique and forward head position correction exercises (MFREx), and the control group. MFR and MFREx groups were given the relevant interventions twice a week for four consecutive weeks, and went through the number ATrPs, range of motion (ROM) of neck, Neck Disability Index (NDI) and the Pittsburgh Sleep Quality Index (PSQI) before and after the intervention. A physical therapist, who was fully familiar with the measuring methods of the equipment, was the measurer and not aware of the target's condition was blinded to take measurements only before and after intervention. Results: There was a significant improvement in the ATrP, Neck ROM, NDI and PSQI in the group of patients to whom the MFR technique and MFREx were applied. MFREx was more effective in increasing neck mobility. Conclusions: According to this study, the application of MFR is effective in improving neck movement and sleep quality in chronic tension headache patients.

Computer Simulation for Gradual Yellowing of Aged Lens and Its Application for Test Devices

  • Kim, Bog G.;Han, Jeong-Won;Park, Soo-Been
    • Journal of the Optical Society of Korea
    • /
    • 제17권4호
    • /
    • pp.344-349
    • /
    • 2013
  • This paper proposes a simulation algorithm to assess the gradual yellowing vision of the elderly, which refers to the predominance of yellowness in their vision due to aging of the ocular optic media. This algorithm employed the spectral transmittance property of a yellow filter to represent the color appearance perceived by elderly people with yellow vision, and modeled the changes in the color space through a spectrum change in light using the yellow filter effect. The spectral reflectivity data of 1269 Munsell matte color chips were used as reference data. Under the standard conditions of a D65 illuminant and a $10^{\circ}$ observer of 1964 CIE, the spectrum of the 1269 Munsell colors were processed through the yellow filter effect to simulate yellow vision. Various degrees of yellow vision were modeled according to the transmittance percentage of the yellow filter. The color differences before and after the yellow filter effect were calculated using the DE2000 formula, and the color pairs were selected based on the color difference function. These color pairs are distinguishable through normal vision, but the color difference diminishes as the degree of yellow vision increases. Assuming 80% of yellow vision effect, 17 color pairs out of $(1269{\times}1268)/2$ pairs were selected, and for the 90% of yellow vision effect, only 3 color pairs were selected. The result of this study can be utilized for the diagnosis system of gradual yellow vision, making various types of test charts with selected color pairs.

Optimization of exposure parameters and relationship between subjective and technical image quality in cone-beam computed tomography

  • Park, Ha-Na;Min, Chang-Ki;Kim, Kyoung-A;Koh, Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • 제49권2호
    • /
    • pp.139-151
    • /
    • 2019
  • Purpose: This study was performed to investigate the effect of exposure parameters on image quality obtained using a cone-beam computed tomography (CBCT) scanner and the relationship between physical factors and clinical image quality depending on the diagnostic task. Materials and Methods: CBCT images of a SedentexCT IQ phantom and a real skull phantom were obtained under different combinations of tube voltage and tube current (Alphard 3030 CBCT scanner, 78-90 kVp and 2-8 mA). The images obtained using a SedentexCT IQ phantom were analyzed technically, and the physical factors of image noise, contrast resolution, spatial resolution, and metal artifacts were measured. The images obtained using a real skull phantom were evaluated for each diagnostic task by 6 oral and maxillofacial radiologists, and each setting was classified as acceptable or unacceptable based on those evaluations. A statistical analysis of the relationships of exposure parameters and physical factors with observer scores was conducted. Results: For periapical diagnosis and implant planning, the tube current of the acceptable images was significantly higher than that of the unacceptable images. Image noise, the contrast-to-noise ratio (CNR), the line pair chart on the Z axis, and modulation transfer function (MTF) values showed statistically significant differences between the acceptable and unacceptable image groups. The cut-off values obtained using receiver operating characteristic curves for CNR and MTF 10 were useful for determining acceptability. Conclusion: Tube current had a major influence on clinical image quality. CNR and MTF 10 were useful physical factors that showed significantly associations with clinical image quality.

Video Based Behavioral Analysis to Observe Attention during Mirror Therapy in Hemiplegic Patients : Preliminary Study

  • Kim, Jinmin;Song, Changho
    • Physical Therapy Rehabilitation Science
    • /
    • 제10권2호
    • /
    • pp.212-216
    • /
    • 2021
  • Objective: Mirror therapy is one of the promising methods suggested for the upper limb rehabilitation of stroke patients. While mirror therapy was presented to be effective in improving motor function of stroke patients, problems were raised as preceding studies had various methods in applying mirror therapy. Some studies even reported no effect in mirror therapy. Our supposition for the reason of such problems was a decrease of attention on the illusive image during mirror therapy of stroke patients, and we aimed to observe this. Design: A cross-sectional preliminary study. Methods: Three hemiplegic acute patients were recruited for the traditional mirror therapy. It lasted for 30 minutes, and 12 different tasks were asked to perform. All procedures were video-recorded, and Observer XT was used to analyse mirror-gazing time, gaze-distracted time, preparation time, frequency of mirror gazing, frequency of distraction, frequency of preparation for treatment. Results: Subjects spent an average of 4-5 minutes having instructions about the mirror therapy intervention (preparation duration), an average of 11 minutes watching the mirror during therapy (mirror-gazing duration), and the rest of 14-15 minutes looking around the environment (gaze-distracted duration). During the mirror therapy, the number of distracted moments (frequency of distraction) was eight times more than focusing on the mirror (frequency of mirror gazing). Conclusions: Once the patient looks at the mirror, it only lasts about 5 seconds on average. Thus, we confirmed that patients could not concentrate on the illusion during the session and therefore it may have affected the effectiveness of the therapy.

Near-Infrared Photopolarimetry of Large Main Belt Asteroid - (4) Vesta

  • Bach, Yoonsoo P.;Ishiguro, Masateru;Takahashi, Jun;Naito, Hiroyuki;Kwon, Jungmi;Kuroda, Daisuke
    • 천문학회보
    • /
    • 제46권1호
    • /
    • pp.45.1-45.1
    • /
    • 2021
  • The polarization degree as a function of phase angle (the Sun-target-observer's angle), so-called the polarimetric phase curves (PPC), have provided priceless information on asteroids' albedos since B. Lyot (1929). Succeeding experimental works in 1970s have confirmed the Umow law: There is a universal and strong correlation between the albedo and the PPC slope (slope of the tangential line at the zero of the PPC at phase angle ~ 20 degrees). Experiments in 1990s (ref [1]), on the other hand, have demonstrated that the negative branch of PPC is dependent on the size parameter (X ~ π * particle-size / wavelength), especially when X <~5. The change in particle size changed the minimum polarization degree, location of the minimum, and the width of the negative branch (called the inversion angle). From polarimetry[2] and spectroscopy[3], large asteroids are expected to be covered with fine (<~ 10 ㎛ size) particles due to the gravity. The size parameters are X ~ 30 at the optical wavelength (λ ~ 0.5 ㎛) and X ~ 10 in near-infrared (J, H, Ks bands; λ ~ 1.2-2.2 ㎛), if the representative particle size of 5 ㎛ is considered. Accordingly, the near-infrared polarimetry has a great potential to validate the idea in ref[1]. We conducted near-infrared photopolarimetry of the large asteroid (4) Vesta using the Nishiharima Infrared Camera (NIC) at Nishi-Harima Astronomical Observatory (NHAO). NIC allows simultaneous polarimetric measurements in J, H, and Ks bands, and thus the change of PPC is obtained for three different size parameters. As a result, we found a signature of the change in the negative branch in the PPC of asteroid (4) Vesta. We will introduce our observation and the results and give an interpretation of the regolith on Vesta.

  • PDF