• Title/Summary/Keyword: Full-scale structure

Search Result 445, Processing Time 0.027 seconds

Experimental study on seismic performances of steel framebent structures

  • Liang, Jiongfeng;Gu, Lian S.;Hu, Ming H.
    • Earthquakes and Structures
    • /
    • v.10 no.5
    • /
    • pp.1111-1123
    • /
    • 2016
  • To study seismic performance of steel frame-bent structure, one specimen with one-tenth scale, three-bay, and five-story was tested under reversed cyclic lateral load. The entire loading process and failure mode were observed, and the seismic performance indexes including hysteretic loops, skeleton curve, ductility, load bearing capacity, drift ratio, energy dissipation capacity and stiffness degradation were analyzed. The results show that the steel frame-bent structure has good seismic performance. And the ductility and the energy dissipation capacity were good, the hysteresis loops were in spindle shape, which shape were full and had larger area. The ultimate elastic-plastic drift ratio is larger than the limit value specified by seismic code, showing the high capacity of collapse resistance. It can be helpful to design this kind of structure in high-risk seismic zone.

Hybrid vibration-impedance monitoring in prestressed concrete structure with local strand breakage

  • Dang, Ngoc-Loi;Pham, Quang-Quang;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • v.30 no.5
    • /
    • pp.463-477
    • /
    • 2022
  • In this paper, a hybrid vibration-impedance-based damage monitoring approach is experimentally evaluated for prestressed concrete (PSC) structures with local strand breakage. Firstly, the hybrid monitoring scheme is designed to alert damage occurrence from changes in vibration characteristics and to localize strand breakage from changes in impedance signatures. Secondly, a full-scale PSC anchorage is experimented to measure global vibration responses and local impedance responses under a sequence of simulated strand-breakage events. Finally, the measured data are analyzed using the hybrid monitoring framework. The change of structural condition (i.e., damage extent) induced by the local strand breakage is estimated by changes in a few natural frequencies obtained from a few accelerometers in the structure. The damaged strand is locally identified by tomography analysis of impedance features measured via an array of PZT (lead-zirconate-titanate) sensors mounted on the anchorage. Experimental results demonstrate that the strand breakage in the PSC structure can be accurately assessed by using the combined vibration and impedance features.

Forced Vibration Test of a Real-Scale Structure and Design of HMD Controllers for Simulating Earthquake Response (실물 크기 구조물의 강제진동실험 및 지진응답 모사를 위한 HMD제어기 설계)

  • Lee, Sang-Hyun;Park, Eun-Churn;Youn, Kyung-Jo;Lee, Sung-Kyung;Yu, Eun-Jong;Min, Kyung-Won;Chung, Lan;Min, Jeong-Ki;Kim, Young-Chan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.103-114
    • /
    • 2006
  • Forced vibration testing is important for correlating the mathematical model of a structure with the real one and for evaluating the performance of the real structure. There exist various techniques available for evaluating the seismic performance using dynamic and static measurements. In this paper, full scale forced vibration tests simulating earthquake response are implemented by using a hybrid mass damper. The finite element (FE) model of the structure was analytically constructed using ANSYS and the model was updated using the results experimentally measured by the forced vibration test. Pseudo-earthquake excitation tests showed that HMD induced floor responses coincided with the earthquake induced ones which were numerically calculated based on the updated FE model.

The Evaluation of the Proposal for Condominium Housing Remodeling in National Housing Scale($85m^2$) (국민주택 규모의 공동주택 리모델링 계획안의 평가)

  • Choi, Jung-Min
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.3 s.62
    • /
    • pp.119-129
    • /
    • 2007
  • This study illustrates a prototype proposal and its evaluation for the development of floor plans in the condominium housing remodeling. For this I evaluated the survey of the residents of the 'K' town in Joonge-dong, Nowon-gu, Seoul, against the proposal which was developed based on the resident's pre-survey. The result includes that the residents' preference for community actions such as the removal of fences which are reviewed as negative, whereas the introduction of a fitness center and community facilities in the library are reviewed as positive. The residents preferred the open space by the piloti structure, although which is the wall column structure, where they anticipated a rest area, sports facilities, and bicycle drop-off spots. The sidewall proposal in the main building and the full use of the roof floor were underestimated in terms of design concept. The research also illustrated the residents' desired space planning options, those tending to use of space 'B type', personalization 'C type' and spatial size 'A type'. Residents responded positively to the introduction of the 'Alpha' space in which two households share one space that could be used for multiple purposes such as a rest area, an environment-friendly garden, and hobby room, etc, and also there is another possibility it plays an important role to the sociality in community.

A Simple Capacitive Sensor Array Based on a Metal-Insulator-Metal Structure

  • Lee, Hee-Ho;Choi, Jin-Hyeon;Ahn, Jung-Il;Kim, Chang-Soo;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.83-89
    • /
    • 2012
  • A simple array of metal-insulator-metal capacitive elements was proposed for a potential application in humidity sensing platforms. We fabricated meso-scale sensors with different sizes(large-size: $2.7{\times}2.7mm^2$ ; mid-size: $1.5{\times}1.5mm^2$ ; small-size: $0.7{\times}0.7mm^2$) and characterized the performance of each design. Polyimide films were utilized as a humidity-sensitive layer. Capacitance changes of the polyimide layer were measured with respect to water absorption. The device showed sensitivity in the full range of relative humidity (RH) with excellent linearity(correlation coefficient > 0.994). This array structure exhibits unique advantages including easy fabrication process, high batch productivity, and high structural compatibility with various substrate materials. It is anticipated that this device structure will be potentially useful in unique applications including mapping spatial humidity variations over a meso-scale area and implementing flexible humidity sensing element arrays.

Real-scale field testing for the applicability examination of an improved modular underground arch culvert with vertical walls

  • Tae-Yun Kwon;Jin-Hee Ahn;Hong-duk Moon;Kwang-Il Cho;Jungwon Huh
    • Advances in concrete construction
    • /
    • v.15 no.6
    • /
    • pp.377-389
    • /
    • 2023
  • In this study, an improved modular arch system with the lower arch space composed of a precast arch block and an outrigger was proposed as an underground culvert, and its applicability and structural behaviors were confirmed. This modular arch culvert structure with vertical walls was designed using precast blocks and by adjusting the placement spacing of concrete blocks to the upper part form an arch shape and the lower part form a vertical wall shape, based on previously researched modular arch systems. Owing to the vertical wall of the proposed modular arch system, it is possible to secure a load-carrying capacity and an arch space that can sufficiently resist the earth pressure generated from the backfill soil and loading on the arch system. To verify the structural characteristics, and applicability of the proposed modular precast arch culvert structure, a full-scale modular culvert specimen was fabricated, and a loading test was conducted. By examining its construction process and loading test results, the applicability and constructability of the proposed structure were analyzed along with its structural characteristics. In addition, its the structural predictability and safety for the applicability were evaluated by comparing the construction process and loading test results with the FE analysis results.

Breastfeeding Adaptation Scale-Short Form for mothers at 2 weeks postpartum: construct validity, reliability, and measurement invariance (산후 2주 축약형 모유수유 적응 측정도구의 구성 타당도, 신뢰도와 측정 불변성)

  • Kim, Sun-Hee
    • Women's Health Nursing
    • /
    • v.26 no.4
    • /
    • pp.326-335
    • /
    • 2020
  • Purpose: This study was conducted to evaluate the construct validity, reliability, measurement invariance, and latent mean differences in the Breastfeeding Adaptation Scale-Short Form (BFAS-SF) for use with mothers at 2 weeks postpartum. Methods: This methodological study was designed to evaluate the validity, reliability, and measurement invariance of the BFAS-SF at 2 weeks postpartum, with data collected from 431 breastfeeding mothers. Confirmatory factor analysis and multi-group confirmatory factor analysis were conducted to assess the factor structure and the measurement invariance across employment status, delivery mode, parity, and previous breastfeeding experience, and the latent mean differences were then examined. Results: The goodness of fit of the six-factor model at 2 weeks postpartum was acceptable. Multi-group confirmatory factor analysis supported strict invariance of the BFAS-SF across employment status and delivery mode. Full configural invariance, full metric invariance, and partial scalar invariance across parity and full configural invariance and full metric invariance across previous breastfeeding experience were supported, respectively. The results for latent mean differences suggested that mothers who were employed showed significantly higher scores for breastfeeding confidence. Mothers who had a vaginal delivery showed significantly higher scores for sufficient breast milk and baby's feeding capability. Multiparous mothers showed significantly higher scores for baby's feeding capability and baby's satisfaction with breastfeeding. Conclusion: The validity and reliability of the BFAS-SF at 2 weeks postpartum are acceptable. It can be used to compare mean scores of breastfeeding adaptation according to employment status, delivery mode, and parity.

System dentification of Apartment Buildings with Wall-Slab configuration using Modal Analysis (모드해석을 통한 벽식구조 아파트건물의 System Identification)

  • 장극관;천영수
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.191-197
    • /
    • 1998
  • This paper described the dynamic characteristics of 20-story apartment buildings from the results of full-scale measurements and analysis. The natural frequencies and mode shapes are quantified by measuring and analyzing ambient vibrations of the structure and compared with the results from dynamic analysis. Comparison with computed mode shapes and frequencies shows good agreement with the experimental results. It proved that it is important to estimate coupling beam and soil parameters through a comparison of the measured results with calculated results.

  • PDF

Pole Assignment for Structural Active Control

  • Vongchavalitkul, Sanguan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.5-7
    • /
    • 2004
  • Significant progress has been achieved in the active control of civil-engineering structures, not only in the control algorithm, but also in control testing of the scaled model and full-scale building. At the present time, most algorithms used in the active control of civil engineering structures are based on the various active control techniques. In this paper represents active control method, by using pole assignment for reducing structural vibration under excited load. Numerical simulations are performed to assess the effectiveness of pole assignment control system. The relative displacement of structure system is significantly reduced.

  • PDF

A Silicon Piezoresistive Accelerometer with Silicon-on-insulator Structure (Silicon-no-insulatir 구조를 갖는 실리콘 압저항 가속도계)

  • 양의혁;양상식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.6
    • /
    • pp.1036-1038
    • /
    • 1994
  • In this paper, a silicon piezoresistive accelerometer is designed and fabricated using a silicon direct bonded wafer. The accelerometer consists of a seismic mass and four cantilevers, and is fabricated mainly by the anisotropic etching method using EPW as an etchant. The measured sensitivity and the resonant frequency are 0.02 mV/V.g and 3.4 kHz, respectively. The nonlinearity is less than $\pm$0.3% of the full scale of the output.