• Title/Summary/Keyword: Full-scale

Search Result 3,019, Processing Time 0.031 seconds

실물크기 점탄성 감쇠기의 동적 특성 (Dynamic Characteristics of Full-Scale Viscoelastic Dampers)

  • 민경원
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall
    • /
    • pp.367-374
    • /
    • 1999
  • this paper focuses on the dynamic characteristics of full-scale viscoelastic dampers through the experimental study. Viscoelastic dampers which dissipate the response energy of a building under earthquake excitation make a role of increasing damping capacity of the building. Therefore it is important to recognize the damping behavior of viscoelastic dampers. Full-scale viscoelastic dampers are made of three types of rubbers for experimental test. The hysteretic behavior is obtained through the load-deformation experiment over the various loading frequencies and damper strains The experimental results show the good performance of viscoelastic dampers under earthquake excitations,

  • PDF

실 구조물 진동제어를 위한 점탄성 댐퍼 설계 및 적용 실험 (Designs and Tests for the Vibration Control of Full-Scale Steel Frame Structure with Added Viscoelastic Dampers)

  • 정정교;김두훈;김영찬;박진일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.687-692
    • /
    • 2002
  • In order to verify the effectiveness of adding visooelastic dampers to full-scale steel frame structure on the reduction of their seismic and wind response a experimental work was carried out. First, The test was conducted on the VE dampers subjected to sinusoidal excitations under a variety of ambient temperatures, frequency, and the damper strain. Results from these tests showed that the viscoelastic dampers have high energy dissipation capacity. Second, The vibration tests was conducted of the full-scale steel frame structure with md without added VE dampers at different temperatures. Viscoelastically damped full-scale structure test result on the effect of ambient temperature show that viscoelastic dampers are very effective in reducing excessive vibration of the structure due to sinusoidal excitation over a wide ringe of ambient temperature.

  • PDF

Evaluation of Internally Cured Concrete Pavement Using Environmental Responses and Critical Stress Analysis

  • Kim, Kukjoo;Chun, Sanghyun
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권4호
    • /
    • pp.463-473
    • /
    • 2015
  • Three full-scale instrumented test slabs were constructed and tested using a heavy vehicle simulator (HVS) to evaluate the structural behavior of internally cured concrete (ICC) for use in pavements under Florida condition. Three mix designs selected from a previous laboratory testing program include the standard mixture with 0.40 water-cement ratio, the ICC with 0.32 water-cement ratio, and the ICC mixture with 0.40 water-cement ratio. Concrete samples were prepared and laboratory tests were performed to measure strength, elastic modulus, coefficient of thermal expansion and shrinkage properties. The environmental responses were measured using strain gages, thermocouples, and linear variable differential transformers instrumented in full-scale concrete slabs. A 3-D finite element model was developed and calibrated using strain data measured from the full-scale tests using the HVS. The results indicate that the ICC slabs were less susceptible to the change of environmental conditions and appear to have better potential performance based on the critical stress analysis.

전기체 구조시험의 덤프밸브 조절절차 개발; (Setup Procedure of Dump Valve for Full-Scale Airframe Test)

  • 김성찬;김성준;황인희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1252-1257
    • /
    • 2003
  • This paper present a procedure of meter-out flow control method for dump valve in full-scale airframe test. Emergency stop, which results in dump state, can be happened during full-scale airframe test by several causes. Because servo valve can't control hydraulics actuator in the dump state, pressure in cylinder chamber may rise abruptly and overload can be acted to the test article. In this paper, the procedure and technology of orifice setting are investigated to protect the test article from unexpected loads by dump. The test results show that the presented methods decrease peak loads and improve unloading characteristics of hydraulic actuators in the dump state.

  • PDF

Numerical Study on the Extrapolation Method for Predicting the Full-scale Resistance of a Ship with an Air Lubrication System

  • Kim, Dong-Young;Ha, Ji-Yeon;Paik, Kwang-Jun
    • 한국해양공학회지
    • /
    • 제34권6호
    • /
    • pp.387-393
    • /
    • 2020
  • Frictional resistance comprises more than 60% of the total resistance for most merchant ships. Active and passive devices have been used to reduce frictional resistance, but the most effective and practical device is an air lubrication system. Such systems have been applied in several ships, and their effects have been verified in sea trials. On the other hand, there are some differences between the results predicted in model tests and those measured in sea trials. In this study, numerical analyses were carried out for a model and a full-scale ship. A new extrapolation method was proposed to improve the estimation of the full-scale resistance of a ship with an air lubrication system. The volume of fluid (VOF) method was considered for the numerical models of the air layer. The numerical method was validated by comparing the experimental data on the air layer pattern and the total resistance.

FRP복합체로 보강된 실물모형 RC보의 보강재 강성에 따른 휨 보강성능 (Flexural Performance of Full-scale RC Beams Strengthened with Different Amount of FRP Composite)

  • 최기선;유영찬;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.125-128
    • /
    • 2006
  • Many research have been carried out concerned with the flexural performance of FRP composite in a various ways. Most of them, however, have used a small-scale specimen, so haven't been fully verified by full-scale model test. In this study, a full-scale RC beam model test for flexural strengthening with CFRP composites has been performed in order to verify test results obtained through a series of small-scale model test with respect to FRP stiffness affecting strengthening performance in the previous studies. A total of 4 specimens have been manufactured including control beam. The specimens strengthened with CFRP composites consist of 3 different CFRP stiffness with 2 types of CFRP composite. Consequently, the purpose of this study is to estimate influence of the size effect of specimens and FRP stiffness on the flexural performance. As a result, the effective strain of FRP composite is inversely proportional to FRP stiffness and ensures the same performance with small-scale model test.

  • PDF

Evolution of Large-Scale Filmless Full-PACS in Korea

  • Kim, Hee-Joung;Haijo Jung;Yoo, Hyung-Sik
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.28-31
    • /
    • 2002
  • Filmless full-PACS in korea has rapidly been growing, since government had supported collaborative PACS project between industry and university hospital in late of 1995. At the same time, a small company had started PACS business, while the Korea PACS society was being formed. In the beginning, PACS societies had focused on developing peripheral solutions such as DICOM gateway for image acquisition, x-ray film digitizer, and viewing software for research or management of personal image data, while Samsung Medical Center had started installing an imported partial PACS system which had recently upgraded with a new system. In similar time frame, a few hospitals had started developing and installing domestic large scale full-PACS system. Several years later, many hospitals have installed full-PACS system with national policy of reimbursement for PACS exams in November 1999. It is believed that Korea is the first country that adopted PACS reimbursement for filmless full-PACS as a national policy. Both experiences of full-PACS installation and national policy generated tremendous intellectual and technological expertise about PACS at all levels, clinical, hospital management, education, and industrial sectors. There are currently three types of PACS system which includes domestic, imported, and hybrid PACS system with imported solution for core system and domestic solution for peripheral system. There are more than 20 domestic PACS companies and they have now enough experiences so that they are capable of installing a truly full-PACS system for large-scale teaching hospitals. PACS societies in Korea understand how to design, implement, install, manage, sustain, and provide good services for large-scale full-PACS. PACS society has also strength for the highest integration technology of the Hospital Information. However, further understanding and timely implementation of continuously evolving international standard and integrated healthcare enterprise concepts may be necessary for international leading of PACS technologies for the future.

  • PDF

실물모형 실험에 의한 탄소섬유쉬트 보강 RC 보의 휨 부착거동 (Flexural Adhesive Behavior of Full-scale RC Beams Strengthened by Carbon Fiber Sheets)

  • 최기선;류화성;최근도;이한승;유영찬;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.1003-1008
    • /
    • 2001
  • It is recently reported that bond failure can be initiated in the region where maximum bending moment and shear force is acted by accompanying shear deformation after flexural crack in full-scale RC beams strengthened by CFRP. Such a shear deformation effect causing bond failure is relatively little in the case of small-scale specimens. So, additional reinforcing details to the critical beam section where maximum moment and shear were acted is required to prevent the bond failure caused by the shear deformations. The U-type wrapping methods by CFRP to the critical beam section is proposed and tested in this paper. Also, the applicability of design bond strength derived from the tests of small-scale beam was investigated by the full-scale RC beam strengthened by CFRP.

  • PDF

휨-전단 복합 거동 원형 RC교각의 내진성능 평가 (Seismic Performance Evaluation of Circular RC Bridge Piers with Shear-Flexure Behavior)

  • 김병석;곽임종;조창백;조정래
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.337-344
    • /
    • 2001
  • Some as-built drawings in national roadway bridges in Korea were examined. There are many bridge piers, whose aspect ratios are in the vicinity of 2.5. These columns are expected to do shear-flexure behaviour and have large scale effect between full and reduced scale model. In the study, full and 1/2 scale model tests on the shear-flexure behaviour columns were carried out. The seismic performance of existing bridge piers without seismic details were examined by Quasi Static Test

  • PDF

유리섬유쉬트에 의한 실물모형 RC보의 보강매수별 휨 보강효과 (Flexural Strengthening with Multi-Layer GFRP Sheets on Full-Scale RC Beams)

  • 유영찬;최기선;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.177-180
    • /
    • 2005
  • The specified tensile strength provided by the manufacturer is determined on the basis of the reliable lower limit ($X-3{\sigma}$ : X=average tensile strength, $\sigma$=standard deviation) obtained from the material test results. Most of these data, however, are based on the test results of 1 layer of FRP sheet. Also, the partial strength reduction factor for strengthening RC members with FRP is based on the small-scale model tests. But, the failure mechanisms of small-scale model tests are reported to be different from those of the full-scale tests. This paper present the test results of full-scale RC beams strengthened with multi-layer GFRP sheets up to 3 layer as well as the material tests. From the material tests, it was observed that the average tensile strengths of GFRP sheets are decreased as the number of layer are increased. Also the premature debonding failure of RC beams strengthened with multi-layer GFRP sheets are observed in inverse proportion to the number of GFRP sheets

  • PDF