• Title/Summary/Keyword: Full resonance

Search Result 252, Processing Time 0.027 seconds

Diagnostic Performance of Simulated Abbreviated MRI for Early-Stage Hepatocellular Carcinoma Screening: A Comparison to Conventional Dynamic Contrast-Enhanced MRI (초기 간암 선별 검사로서 단축 자기공명영상 검사의 진단능: 고식적 역동학적 자기공명영상검사와의 비교)

  • Eun Sol Lim;Sung Mo Kim;Sang Soo Shin;Suk Hee Heo;Jong Eun Lee;Yong Yeon Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1218-1230
    • /
    • 2021
  • Purpose To compare the per-patient diagnostic performance of simulated abbreviated MRI (AMRI) to that of conventional MRI (CMRI) with full-sequence dynamic gadoxetic acid (GA) enhancement for early-stage hepatocellular carcinoma (HCC) screening in high-risk patients. Materials and Methods A total of 201 consecutive patients at high-risk for HCC, who underwent 3T liver MRI, were included in this retrospective study. The AMRI protocol comprised T2-weighted imaging, hepatobiliary phase imaging after GA injection, and diffusion-weighted imaging. For each patient, two AMRI and CMRI image sets were independently reviewed by two radiologists. Inter-reader agreement was assessed using Cohen's kappa value. A composite reference standard was used to determine the diagnostic performance of each image set for each reader. Results A total of 93 HCCs were detected in 79 patients. The inter-reader agreement was almost perfect for both image sets (κ = 0.839, 0.948). In AMRI, the per-patient sensitivity and negative predictive values (NPV) were 94.9% and 96.4%, respectively. In CMRI, the per-patient sensitivity and NPV were 96.2% and 97.5%, respectively. Conclusion AMRI, using only three sequences, had a comparable diagnostic performance to CMRI in screening early-stage HCC. AMRI could be an alternative HCC screening tool for high-risk HCC patients.

Optochiasmatic cavernoma: Surgical treatment and outcomes

  • Anton Konovalov;Oleg Saripov;Vadim Gadzhiagaev;Oleg Titov;Nikolay Lasunin;Abzal Zhumabekov;Dmitry Fomichev;Eliava Shalva Salvovich;Pavel Kalinin;Bipin Chaurasia
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.4
    • /
    • pp.411-419
    • /
    • 2023
  • Objective: Optochiasmatic cavernoma is an extremely rare cerebral lesion. They account for approximately 1% of all cavernomas of the central nervous system. Reports on this pathology are limited. Abrupt visual deterioration is a common symptom of the disease. Treatment strategy and visual outcomes after different treatment approaches remain a subject for discussion. Methods: Patients operated in a period 2005-2021 were analyzed in this study. All patients preoperatively underwent computed tomography (CT) scan, CT-angiography, and magnetic resonance imaging (MRI). Visual function of the patients was assessed pre-op, post-op and at the follow-up. Duration of visual dysfunction was noted as well. Surgical details were also extracted from medical notes. All patients were followed up, and control MRI was performed one month after operation. We assessed surgical series of optochiasmatic cavernomas published for last 10 years. Further comparative analysis with our data was performed. Results: Five patients were included into this study. There were four men and one woman. Mean age comprised 33.8 years (range 20-48 years). Most patients were admitted to our hospital due to visual disturbances (80%). Visual function improved in four patients. Visual function was unchanged in one patient, lacking visual distur-bancies pre-op. Complication developed in one patient. Conclusions: Optochiasmatic cavernomas are encountered extremely rare. Despite the use of contemporary diagnostic options, differential diagnosis remains challenging. Full diagnostic work-up is mandatory. After the diagnosis is made, surgical treatment should be considered first. Total microsurgical or endoscopic transsphenoidal removal of the optochiasmatic cavernoma is a relatively safe and effective treatment method facilitating improvement of visual function.

The Development of Theoretical Model for Relaxation Mechanism of Sup erparamagnetic Nano Particles (초상자성 나노 입자의 자기이완 특성에 관한 이론적 연구)

  • 장용민;황문정
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.39-46
    • /
    • 2003
  • Purpose : To develop a theoretical model for magnetic relaxation behavior of the superparamagnetic nano-particle agent, which demonstrates multi-functionality such as liver- and lymp node-specificity. Based on the developed model, the computer simulation was performed to clarify the relationship between relaxation time and the applied magnetic field strength. Materials and Methods : The ultrasmall superparamagnetic iron oxide (USPIO) was encapsulated with biocompatiable polymer, to develop a relaxation model based on outsphere mechanism, which was resulting from diffusion and/or electron spin fluctuation. In addition, Brillouin function was introduced to describe the full magnetization by considering the fact that the low-field approximation, which was adapted in paramagnetic case, is no longer valid. The developed model describes therefore the T1 and T2 relaxation behavior of superparamagnetic iron oxide both in low-field and in high-field. Based on our model, the computer simulation was performed to test the relaxation behavior of superparamagnetic contrast agent over various magnetic fields using MathCad (MathCad, U.S.A.), a symbolic computation software. Results : For T1 and T2 magnetic relaxation characteristics of ultrasmall superparamagnetic iron oxide, the theoretical model showed that at low field (<1.0 Mhz), $\tau_{S1}(\tau_{S2}$, in case of T2), which is a correlation time in spectral density function, plays a major role. This suggests that realignment of nano-magnetic particles is most important at low magnetic field. On the other hand, at high field, $\tau$, which is another correlation time in spectral density function, plays a major role. Since $\tau$ is closely related to particle size, this suggests that the difference in R1 and R2 over particle sizes, at high field, is resulting not from the realignment of particles but from the particle size itself. Within normal body temperature region, the temperature dependence of T1 and T2 relaxation time showed that there is no change in T1 and T2 relaxation times at high field. Especially, T1 showed less temperature dependence compared to T2. Conclusion : We developed a theoretical model of r magnetic relaxation behavior of ultrasmall superparamagnetic iron oxide (USPIO), which was reported to show clinical multi-functionality by utilizing physical properties of nano-magnetic particle. In addition, based on the developed model, the computer simulation was performed to investigate the relationship between relaxation time of USPIO and the applied magnetic field strength.

  • PDF

The Results of Arthroscopic Double-Row Rotator Cuff Repairs with Combined Knot-tying and Knotless Suture Anchors (매듭 결속과 비매듭 봉합나사를 이용한 관절경적 이열 회전근개 봉합술의 결과)

  • Ku, Jung-Hoei;Lee, Choon-Key;Cho, Hyung-Lae;Choi, Seung-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.172-179
    • /
    • 2008
  • Purpose: To evaluate the functional and structural results of arthroscopic double-row repair using combined knot-tying and knotless suture anchors in rotator cuff tears. Materials and Methods: From March 2006 to June 2007, twenty-one patients (15 males, 6 females; mean age 55.6 years; range 48 to 67) were included who underwent arthroscopic double-row repair for full-thickness tears of the rotator cuff following conservative treatment for a mean of 6.5 months (range 3 to 11). The tear size was carefully inspected arthroscopically and we found 2 small, 13 medium and 6 large-sized rotator cuff tears, with a mean tear size of 2.5cm(range 1.8 to 3.2). The repair constructs were consisted of horizontal mattress sutures using conventional knot-tying suture anchors medially and simple suture at the same level of medial row stitch with Bioknotless RC anchors (DePuy Mitek, Norwood, MA) as lateral row. Clinical and functional evaluations were made according to the range of motion, the ASES, UCLA scale and the isokinetic strength testing. Postoperative cuff integrity was determined through magnetic resonance imaging. The mean follow-up was 15 months (range 13 to 24). Results: The average clinical outcome scores and strength were all improved significantly at the time of the final follow-up (p < 0.01). Nineteen patients (90%) were satisfied with the result of the treatment. In 17 of 21 patients (81%) were judged to reveal healed tendon on magnetic resonance imaging at a mean of 7 months postoperatively. There were no significant functional differences according to the preoperative tear size (p<0.01), but large-sized tear shows less favorable structural results in 3 out of 6 cases(50%). Conclusion: Our results document the usefulness and variability of arthroscopic double-row rotator cuff repairs comparable to the results of the other types of double-row repairs.

  • PDF

Acromial Morphology in Different MR Oblique Sagittal Slices: Correlation with Rotator Cuff Disorder (자기 공명 영상의 사 시상면에서의 견봉 형태의 변화: 회전근 개 질환과의 임상적 연관성 분석)

  • Jo, Chris H.;Kim, Ji-Beom;Choi, Hye-Yeon;Ko, Young-Whan;Yoon, Kang-Sup;Lee, Ji-Ho;Kang, Seung-Baik;Lee, Jae-Hyup;Han, Hyuk-Soo;Rhee, Seung-Whan
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.173-179
    • /
    • 2009
  • Purpose: On the hypothesis that the acromion morphology is changed according to the its site, we identified the morphology of the acromion on the oblique slices of MRI and we investigated the association of the acromial shape with the clinical stages of rotator cuff disorder on the magnetic resonance (MR) images. In addition, we compared the acromion morphology on MRI and simple X-rays. Material and Methods: The MR images of seventy one patients with rotator cuff disorder and who underwent arthroscopic surgery were compared with that of a control group of sixteen patients who didn't have rotator cuff disorder on MRI. On three subsequent oblique sagittal slices from the lateral edge of the acromion (S1, S2 and S3), each acromion morphology on the MRI slices was classified according to Epstein et al: flat, curved or hooked. We investigated the changing parttern of the acromion shape and we compared the acromion shape on MRI and that on simple X-rays. We classified the rotator cuff tear by the severity: bursitis, partial thickness tear or full thickness tear. We investigated which acromial type on the MRI oblique slice was associated with the severity of rotator cuff disease. Results: Changes of the acromial shape occurred in 54 patients (76.1%). The most frequent pattern was that the types are same on S1 and S2 and different on S3 (22 cases, 31.0%). The acromial type on S1 and S2 was significantly associated with the severity of rotator cuff disorder (p=0.001 and 0.022), respectively. There was no reliability of the acromial shape on MRI and roentgenography (p>0.05) Conclusion: The type of acromion changed from lateral to medial. Among the three positions, the shape of the acromion on S1 and S2 had meaningful correlation with the clinical stage of rotator cuff disorder. There was no statistical correlation of the acromial shape between MRI and simple X-ray.

Clinical and Imaging Findings of Neonatal Seizures Presenting as Diffuse Cerebral White Matter Abnormality on Diffusion-Weighted Imaging without any Structural or Metabolic Etiology (확산강조영상에서 미만성 대뇌 백질의 이상을 보이는 신생아 경련 환자에서 구조적 이상이나 대사와 관련된 원인이 없을 경우 임상적 소견과 영상 소견의 특징)

  • Maeran Kim;Jae-Yeon Hwang;Yeoun Joo Lee;Yong-Woo Kim;Shin Yun Byun;Yun-Jin Lee;Jeong A Yeom;Ung Bae Jeon;Ki Seok Choo;Kyung Jin Nam;Storm Nicholas Shaun Reid
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1412-1423
    • /
    • 2020
  • Purpose Some patients with neonatal seizures show diffuse, symmetric diffusion-restricted lesions in the cerebral white matter. The aim of this study was to describe clinical and imaging findings of patients with neonatal seizures who had diffuse, symmetric diffusion-restricted lesions without any structural or metabolic etiology. Materials and Methods A total of 56 neonates aged less than 1 week underwent brain magnetic resonance imaging (MRI) for evaluation of seizures from November 2008 to February 2017. After excluding 43 patients, 13 patients showed diffuse white matter abnormality on diffusion-weighted imaging. Initial and follow-up clinical and MRI findings were analyzed retrospectively. Results All 13 patients were born at full term. Among the ten patients who underwent a stool test for viruses, six were positive for rotavirus and one for astrovirus. MRI revealed diffuse, symmetric diffusion-restricted lesions distributed along the cerebral white matter, thalami, and midbrain variably. Conclusion Diffuse, symmetric diffusion-restricted lesions involving the cerebral white matter can be seen in patients with neonatal seizures without any structural or metabolic etiology. Rotavirus is commonly but not exclusively detected in these patients. Nevertheless, viral infection-associated encephalopathy should be considered for patients with characteristic clinical and MRI findings.

Usefulness of Serial Ultrasonography of the Rotator Cuff Repair (회전근 개 파열의 수술적 치료시 초음파 연속 검사의 유용성)

  • Park, Jae-Hyun;Choi, Won-Ki;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.2
    • /
    • pp.78-85
    • /
    • 2008
  • Purpose: The findings of preoperative magnetic resonance imaging (MRI) and ultrasonography (US) examination in the diagnosis of rotator cuff tear were then compared with the findings of arthroscopic examination, and to evaluate the postoperative integrity of rotator cuff using serial US examination. Methods: Between February and May 2008, 29 patients with rotator cuff tear had undergone preoperative US and MRI examination and subsequent arthroscopic examination. And the results of MRI and US were compared with intra-operative results of the arthroscopic examination. We observed the postoperative integrity of rotator cuff using serial (postoperative 2 weeks, 6 weeks, 3 months) US examination. Results: The sensitivity of US and MRI for identifying rotator cuff tear were 100% and 100%. The sensitivity of US and MRI were 95% and 82% in full thickness tear, and 50%, 33% in partial thickness tear, respectively. Overall accuracy of US and MRI were 86%, 69%. Among 22 patients were operated for full thickness tear, intra-operative gap formation was identified in 11 patients (50%, small to medium 2 cases, large to massive 9 cases) which were identified at 2 weeks postoperative US. We could find 5 re-tears (23%, small to medium 1 case, large to massive 4 cases) on 6 weeks postoperative US after passive range of motion (ROM) exercise, and could also find 7 re-tears (32%, small to medium 2 cases, large to massive 5 cases)on 3 months postoperative US after active ROM exercise. Conclusion: Serial US after arthroscopic rotator cuff repair was useful to differentiate intra-operative gap formation from postoperative re-tear. We found 5 retears (23%) at 6 weeks and 7 retears (32%) at 3 months postoperative US, it was useful to make treatment plan during postoperative rehabilitation.

  • PDF

The Significance of Maturation Score of Brain Magnetic Resonance Imaging in Extremely Low Birth Weight Infant (초극소 저체중 출생아의 뇌 MRI 상 Maturation Score의 의의)

  • Song, In-Gu;Kim, Su-Yeong;Kim, Cur-Rie;Kim, Yoon-Joo;Shin, Seung-Han;Lee, Seung-Hyun;Lee, Jae-Myoung;Lee, Ju-Young;Kim, Ji-Young;Sohn, Jin-A;Lee, Jin-A;Choi, Chang-Won;Kim, Ee-Kyung;Cheon, Jung-Eun;Kim, Woo-Sun;Kim, Han-Suk;Kim, Byeong-II;Kim, In-One;Choi, Jung-Hwan
    • Neonatal Medicine
    • /
    • v.18 no.2
    • /
    • pp.310-319
    • /
    • 2011
  • Purpose: The aim of this study was to investigate the effect of perinatal risk factors on brain maturation and the relationship of brain maturation and neurodevelopmental outcomes with brain maturation scoring system in brain MRI. Methods: ELBWI infants born at the Seoul National University Children's Hospital from January 2006 to December 2010 were included. A retrospective analysis was performed with their medical record and brain MR images acquired at near full term. We read brain MRI and measured maturity with total maturation score (TMS). TMS is a previously developed anatomic scoring system to assess brain maturity. The total maturation score was used to evaluate the four parameters of maturity: (1) myelination, (2) cortical infolding, (3) involution of glial cell migration bands, and (4) presence of germinal matrix tissue. Results: Images from 124 infants were evaluated. Their mean gestational age at birth was 27.1${\pm}$2.1 weeks, and mean birth weight was 781.5${\pm}$143.9 g. The mean TMS was 10.8${\pm}$2.0. TMS was significantly related to the postmenstrual age (PMA) of the infant, increasing with advancing postmenstrual age (P<0.001). TMS showed no significance with neurodevelopmental delay, and with brain injury, respectively. Conclusion: TMS was developed for evaluating brain maturation in conventional brain MRI. The results of this study suggest that TMS was not useful for predicting neurodevelopmental delay, but further studies are needed to make standard score for each PMA and to re-evaluate the relationship between brain maturation and neurodevelopmental delay.

The results of arthroscopic repair according to the delamination of rotator cuff (회전근 개 판분리 파열에 따른 관절경하 회전근 개 봉합술의 결과)

  • Ku, Jung Hoei;Cho, Hyung Lae;Park, Man Jun;Kim, Jeong Cheol
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.2
    • /
    • pp.61-68
    • /
    • 2011
  • Purpose: We evaluated the clinical outcome after arthroscopic repair in full thickness rotator cuff tears with and without delamination. Materials and Methods: From March 2006 to October 2008, we included 48 consecutive shoulders (31 males, 17 females; mean age 57.6 years; 45~68) who had arthroscopic double row repair for fullthickness tears of the rotator cuff. Mean rotator cuff tear size was 2.8 cm (range: 1.2~3.6) and the techniques of tendon-to-bone fixation varied according to the presence of delamination; separate row fixations of bursal and articular layer were used in delaminated tear. The mean follow-up was 26 months (range: 18~33) and functional and structural results were evaluated by American Shoulder and Elbow Surgeons (ASES), University of California at Los Angeles (UCLA) scale, isokinetic strength testing and magnetic resonance imaging (MRI) obtained mean 8 months (range:6~13) postoperatively. The patterns of delamination, age, sex, symptom duration, size of tear, satisfaction rate, retear rate ware compared and significance was set at p values < 0.05. Results: Postoperative functional shoulder score improved significantly in 44 shoulders (91.7%). Delamination was observed in 15 shoulders (31%) and it extended proximally and posteriorly in the majority of shoulders, and the articular layer was thicker (8/15, 53%) and more retracted (9/15, 60%) compared with the superficial bursal layer. Final follow up functional shoulder scores showed no differences between non-delaminated and delaminated tears and the presence of delamination had no correlations with sex, symptom duration, tear size and satisfaction rate, however, older age had more delaminated tears (p=0.041). Follow up MRI in 29 shoulders revealed that fourteen (48%) shoulders had complete healing; nine (31%), partial healing; six (21%), complete retear but the half of the retear group showed favorable clinical results. 79% (15/19) in non-delaminated tear and 80% (8/10) in delaminated tear were judged as healed tendon on MRI and double-layer double row repairs in delaminated tears resulted in nearly same rate of structural integrity of single-layer double row repairs (p=0.165). Conclusion: The incidence of delamination in our series was 31% and older age had more delaminated tears. Sex, symptom duration, preoperative size of the tear, functional results and satisfaction rate had no significant correlations with the presence of delamination. Nearly the same postoperative structural integrity was noted in both delaminated and non-delaminated tears.

  • PDF

The Effect of Placing Biomembrane cover following Microfracture on Cartilage Repair: Comparison with Conventional Microfracture Technique in a Prospective Randomized Trial (미세골절술 후 생체막 덮개가 연골 재생에 미치는 영향 : 고식적인 미세골절술과의 전향적 비교 연구)

  • Son, Kwang-Hyun;Kim, Jin-Ho;Kwak, Kyu-Sung;Park, Jang-Won;Yoon, Kyoung Ho;Min, Byoung-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.15 no.2
    • /
    • pp.83-91
    • /
    • 2011
  • Purpose: Microfracture has been used as a first-line treatment to repair articular cartilage defects. In this study, a new technique using an extracelluar matrix biomembrane to cover the cartilage lesions after microfracture was evaluated in terms of cartilage repairability and clinical outcome compared with conventional microfracture technique in a prospective randomized trial. Materials and Methods: A total of 53 patients (59 cases) without osteoarthritis who had focal full thickness articular cartilage lesions were randomly assigned in two group. Seventeen patients (17 cases) underwent conventional microfracture procedure (control group) and thirty-six patients (42 cases) received microfracture and placing biomembrane cover (ArtiFilm$^{TM}$) concomitantly (experimental group). Clinical assessment was done through 6 months postoperatively using the subjective International Knee Documentation Committee IKDC questionnaire, and visual analog scale (VAS) for pain and satisfaction. Magnetic resonance imaging (MRI) was performed at 6 months after the operation in all patients. Results: In clinical outcomes, the significant difference was observed between both groups in IKDC, but not in VAS for pain and for satisfaction (final outcomes of IKDC, p=0.001; VAS for pain, p=0.074; VAS for satisfaction, p=0.194). The MRI showed good to complete defect fill (67 to 100%) in 33 patients (78.6%) of experimental group and 4 patients (23.5%) of control group, respectively. In control group, 9 of 17 patients (52.9%) showed poor defect fill (less than 33%), whereas 5 (11.9%) in experimental group (p=0.001). Assessment of peripheral integration revealed no gap formation in 35 patients (83.3%) in experimental group and 6 patients (35.3%) in control group (p=0.001). No serious complications or adverse effects related to the biomembrane were found. Conclusion: Good short-term follow-up clinical results were obtained in the group whose cartilage defects in the knee joint were covered with biomembrane after the microfracture, with the MRI findings confirming the excellent regeneration of the defective cartilage area. This suggests that the surgery to cover the defective area with biomembrane (ArtiFilm$^{TM}$) after the microfracture procedure is a safe, more effective treatment to induce cartilage regeneration.

  • PDF