• Title/Summary/Keyword: Full denture

Search Result 113, Processing Time 0.021 seconds

Correction of an unusual abnormal buccal frenum by Total Palatal Mucosal Free Graft : A Case Report (Total Palatal Mucosal Free Graft를 이용한 비정상 협소대 치험 1예)

  • Park, Hyung-Sik;Kim, Sun-Yong;Lee, Sang-Hye
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.12 no.3
    • /
    • pp.42-48
    • /
    • 1990
  • This is a case report on an unusual - heavy buccal frenum in young lady which was treated by frenectomy, vestibuloplasty and total-palatal mucosal free graft. The authors noticed that this abnormal condition lead several chronic complications in young patient as like as premature loss of upper molar teeth, early and rapid loss of alveolar bone around insertion of frenum, over - extended eruption of lower molar teeth and abnormal mandibular movements, etc. After frenectomy and surgical extension of buccal vestiblue on both upper and lower posterior regions, we obtained a full - sized palatal mucosal graft and moved it on upper and lower extension area seperately as two pieces of free grafts to offer inherent function of denture - bearing mucogingiva and same color - matching with oral mucosa and to prevent post - operative relapse of vestibular height. We discussed here about unusual abnormality and their complications of unusual buccal frenum and its treatment.

  • PDF

Reestablishing the occlusal plane in full mouth rehabilitation patient, using Shilla system (전악수복환자에서 Shilla system을 이용한 교합평면 재구성 증례)

  • Yang, Min-Soo;Vang, Mong-Sook;Park, Sang-Won;Lim, Hyun-Phil;Yun, Kwi-Dug;Yang, Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.33-38
    • /
    • 2013
  • Occlusal plane is a sagittal expression of dental arch form, and it composes the shape of occlusion, which is one of the most important elements of Maxillo-oral system. In this case, vertical, horizontal coordinates of bionic-median-sagittal plane was produced in articulator, and to achieve relation of left and right position of upper, lower teeth and deficits in alveola, Shilla system was used to reconstruct occlusal plane. In this case, a 41 year-old male patient visited for fracture of 10 unit metal-ceramic fixed partial denture of upper anterior teeth and for overall treatment. Clinical, radiographical, model examination was held, full mouth rehabilitation was achieved by placing dental implant. Maxillo-oral relation was recorded using Gothic arch Tracer complex and were mounted. And for the next step, we estimated original occlusal plane using Shilla system. After analysis we produced diagnosis wax pattern. On the basis of this, radiography stent was manufactured and dental implant was placed, and temporary prosthesis was made by using diagnosis wax pattern. Cross mounting and anterior guiding table were performed in order to reproduce temporary restoration morphology and bite pattern, followed by final restoration made of all ceramic crown with zirconia coping. As stated above, appropriately esthetic and functional results can be seen in using Shilla system in diagnosis and treatment procedure of full mouth rehabilitation patient.

Full-mouth rehabilitation of a patient with loss of posterior support and collapsed occlusion utilizing dental CAD-CAM system (구치부 지지 소실 및 무너진 교합관계를 보이는 환자에서 Dental CAD-CAM system을 활용한 완전 구강 회복 증례)

  • Jung, Jiwon;Heo, Seong-Joo;Kim, Seong-Kyun;Koak, Jai-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.44-54
    • /
    • 2022
  • Without proper treatment on the multiple tooth missing area, the lack of posterior support and the supra-eruption of the teeth cause many severe complications of occlusion, vertical dimension and masticatory function. This report is a case of full-mouth rehabilitation of a patient with loss of posterior support and collapsed occlusion due to missing teeth area left untreated for a long time. The patient who is 68-year old male patient had some teeth fallen out while removing his old maxillary denture and was complaining about pain in the region of anterior teeth due to traumatic contact. The vertical dimension was corrected by 4 mm from the top cervical point of the canine through various evaluations and the edentulous area was treated with the implant fixed prostheses through computer guided implant surgery based on the diagnosis and treatment plan for definitive prostheses supported by computed tomography (CT) data analysis and CAD-CAM (Computer-aided design/computer-aided manufacturing) technique. After full mouth rehabilitation, the patient was very satisfied with remarkable improvements in mastication, function, and aesthetics.

Safety education needs among the dental technology-major college students to prevent injuries in their laboratory classes (치기공과 학생들의 실습 중 안전에 대한 안전교육 요구도 특성)

  • Park, Jong-Hee
    • Journal of Technologic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.177-198
    • /
    • 2006
  • This study purposed to offer basic data for safety education of the dental laboratory technology after the investigation of how much the students in the dept. of dental laboratory technology are aware of the danger of each instrument, equipment or laboratory procedure that they use during laboratory and how much they demand safety education for this. The objects for this study were 423 students who were in the dept. of dental laboratory technology. In this regard, four colleges which have the dept. of dental laboratory technology were randomly selected to do a questionnaire survey. SPSS 12.0 was used to analyze the collected data. The results were as follows: As for satisfaction with their major, the respondents answered Satisfied (59.1%), Average (35.5%) and Dissatisfied (5.4%). In terms of the production process of a partial denture, they considered casting, polishing the casting body, polishing denture and burn out were most dangerous in order. As for the production process of a full denture, what they regarded as the most dangerous in order was polishing denture, deflasking and wax wash. Regarding the laboratory procedures of porcelain material, casting, trimming casting body, polishing porcelain material and burn out were the most dangerous procedures that they perceived. With regard to materials for use, alcohol, polishing, metal and wire were the most dangerous ones they thought. As for the handling characteristics of each material, small towns showed a higher demand for safety of the handling characteristics of alcohol. In terms of school year and sex, juniors and girls had higher scores in the demand for safety of the handling characteristics of acid. Regarding the handling characteristics of each equipment and instrument, all of small towns, juniors and girls showed the highest demand for safety of the handling characteristics of alcohol lamps. With regard to scores in the demand for safety of other characteristics, all of small towns, juniors and girls had the highest demand for safety of emergency treatment. Concerning the demand for safety education by the completion of safety education, in terms of each material, highest was the demand for safety of acid from the group which completed safety education. In regard to equipments and instruments, when it came to the demand for safety of the handling characteristics of casting machine, the educated group's demand for safety of acid was higher. Regarding other characteristics, the group which was not educated gained higher scores in the demand for safety of emergency treatment. 11. In all areas(materials, machines and others), small towns, girls and juniors showed higher scores in the demand for safety. Based on the above results, it was found that when students conduct the laboratory of dental technology, they would think that many materials, instruments or equipments for use are very dangerous. However, safety education was not fully given to them. Regarding the scores in the damned for safety education, the highest was 4.16 and the lowest was 3.43, which suggests that the scores were generally very high. In this regard, it is necessary to continue delivering a systematic safety education of materials, equipments or instruments used during the laboratory of dental technology. Therefore, through the analysis of each material, instruments or facility used in every laboratory and each process, safety accident types and accident risk factors should be investigated to develop educational materials for this. Moreover, it is required to open safety education as a single course of study or insert safety contents of all materials and machines into the class of dental laboratory instrument or dental materials for the purpose of a systematic and thorough safety education to prevent a safety accident during laboratory.

  • PDF

Implant prosthesis for fully edentulous patients using intra-oral scanning and abutment merging technique: A case report (무치악 환자에서 구강 스캔과 지대주 중첩을 이용한 임플란트 보철수복 증례)

  • Hwang, Chan-Hyeon;Jeong, Seung-Mi;Kim, Yong-Jun;Kim, Kyeong-Hee;Fang, Jeong-Whan;Kim, Dae-Hwan;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.61-70
    • /
    • 2017
  • In this case, the impression surface of the existing denture was scanned and was inverted three-dimensionally to express the residual ridge form. Implant planning was performed on the superimposed data of the CT with the scanned image of the denture with radiopaque markers attached. At the day of surgery, customized abutments fabricated in accordance with the form of the gingival margin were linked with fixtures and temporary restorations were set. In the process of fabricating the final prosthesis after the osseointegration of implant fixture, the intraoral scan images at abutment level were merged with images of the abutments scanned and stored before implant surgery. By fabricating the final prosthesis with the abutments obtained by merging can increase the marginal fitness of the final prosthesis and simplify the clinical process.

A Study on the education status in department of Dental Technology (Focusing on the Dental Laboratory practice education) (임상 실습을 중심으로한 치기공(학)과 교육 실태조사)

  • Park, Jong-Hee
    • Journal of Technologic Dentistry
    • /
    • v.37 no.3
    • /
    • pp.131-144
    • /
    • 2015
  • Purpose: This study set out to propose plans for more efficient and effective clinical practice by investigating the current state of clinical practice in the field of dental technology and thus provide basic data to develop pre- and post-education programs for clinical practice. Methods: The subjects include dental technicians at dental technical laboratories that were appointed as the place of clinical practice by the Department of Dental Technology of G University. The survey period spanned from December 22, 2014 to January 20, 2015. Total 250 questionnaires were distributed to them, and 190(76.0%) were returned. After excluding 23 whose answers were uncertain or seemed to lack reliability, total 167(66.8%) were used in final analysis. Results: 1. The most frequent practice the student did during clinical practice was articulator attachment, which was followed by pin operation or model making, one's own task and practice, sand and crow sculpturing, burying, casting, and grinding. 2. In case of going through the entire process, porcelain had the most students at 39(23.4%), being followed by crown & bridge at 28(16.8%), clinical model at 23(13.8%), full denture at 17(10.2%), and partial denture at 17(10.2%) in the order. 3. Of the students, 59.8%(30.5% for reinforced basic practice; 29.3% for intensive practice education) said that intensive practice education should be reinforced in school; and 22.3% said that intensive theory and practice education was needed, which indicates that 82.6% voiced their opinion of reinforcing education around practice. 4. The students felt that they lacked diligence, passion, and theoretical knowledge somewhat and were relatively good at clinical adaptation and operational skills. Conclusion: The findings show that the students felt an absolute lack of practice education as the school education was focused on theory and national exams in the field of dental technology, thus raising a need to reinforce practice education. Of all the respondents, 62.9% said there was a need to improve the current education with a focus on jobs. In future, education of dental technology should work to bring up able dental technicians that can perform in clinical dental technology right after graduation by reinforcing job-based practice education.

The Effect of Korean Elderly's Prosthetic Status on Health Related Quality by Using EuroQol-5 Dimension (한국 노인의 보철상태에 따른 건강관련 삶의 질)

  • Park, Jeong-Hye;Lee, Min-Kyung;Lee, Jung-Hwa;Jin, Hye-Jung
    • Journal of dental hygiene science
    • /
    • v.14 no.3
    • /
    • pp.417-423
    • /
    • 2014
  • The aim of this study was to evaluate the relationship between prosthetic status and health related quality of elderly by using EuroQol-5 dimension (EQ-5D) which is a standardized instrument used as a measure of health outcome. Data from 1,179 elderly subjects (over 65 years old) from the fifth Korea National Health and Nutrition Examination Survey were used in our analysis. Oral examination were conducted to obtain wearing prosthetic and needed prosthetic. EQ-5D is a widely used health condition measuring instrument. It consists of the five dimensions: Mobility, Self-care, Usual activities, Pain/discomfort and Anxiety/depression. EQ-5D index is a score calculated out of a weighting system. In this study, the mean score of the EQ-5D index among the elderly was 0.86. For EQ-5D index gender, female showed statistically significantly lower quality of life than male. The related factors EQ-5D index, when the lower demand for fixed prosthodontics and full denture. Wearers in partial and complete denture than non-wearers showed higher EQ-5D index. In order to improve EQ-5D index among the elderly who demand prosthetic status, which has lost its function through providing proper dental prostheses.

Full mouth rehabilitation of a partially edentulous patient with crossed occlusion using implant-retained RPD with zirconia occlusal table (엇갈린 교합을 가진 부분 무치악 환자에서 지르코니아 교합면을 가지는 Implant-Retained RPD 이용한 전악 수복 증례)

  • Kwon, Tae-Min;Seo, Chi-Won;Kim, Kyung-A;Ahn, Seung-Geun;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.314-321
    • /
    • 2016
  • Conventional removable partial dentures (RPDs) with distal extensions are associated with some problems, including lack of stability that calls for frequent relining, and cantilever actions of claps that can produce excessive loading to abutment teeth, and the need for unesthetic retentive arm clasps. Therefore, IARPDs (Implant-assisted RPD) that use implants to support or retain RPDs has been reported to improve stability, esthetics and masticatory performance of RPDs. Also, an IARPD that has zirconia occlusal table can prevent the incongruity of occlusal plane and the extrusion of antagonistic tooth. In this case of partially edentulous patient with crossed occlusion, each edentulous area was restored with implant fixed prosthesis and implant retained partial denture to suit each situation. Through the procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.

Full mouth rehabilitation of fully edentulous patient with implant-supported fixed prosthesis preceding bone graft: A case report (전악 무치악 환자에서 골이식술을 선행한 임플란트 고정성 보철 수복 증례)

  • An, Ju-Nam;Lee, Jung-Jin;Seo, Jae-Min;Kim, Kyoung-A
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.77-87
    • /
    • 2018
  • Prosthetic treatment using implants in fully edentulous patients includes implant-supported fixed prosthesis, implant hybrid prosthesis, implant retained- or supported-over-denture and implant supported fixed prosthesis has advantages such as psychological stability, pronunciation. If an implant supported fixed prosthesis is planned, the implants should be placed in consideration of pronunciation, esthetics, and oral hygiene. For this, clinical and radiological diagnosis is indispensable. When placing the prosthetic driven implant at the site determined from the diagnosis, a sufficient amount of alveolar bone and soft tissue support are required. If these requirements found to be insufficient, a wide range of bone grafting should be performed in advance. In this case, a fully edentulous patient with severe alveolar bone resorption due to periodontal disease was treated with a full mouth rehabilitation using implant-supported fixed prosthesis preceding maxillary sinus graft and alveolar bone augmentation. We report this patient were satisfied with esthetic and function.

Full mouth rehabilitation in osteoporosis patient with loss of teeth and excessive wear (치아 상실과 심한 마모를 보이는 골다공증 환자에서의 완전구강 회복 증례)

  • Kim, Hyun-Tack;Kim, Myung-Joo;Lim, Young-Jun;Kwon, Ho-Beom
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.63-70
    • /
    • 2022
  • Teeth wear with loss of posterior support often leads to symptoms such as irregular occlusal plane and excessive wear of anterior teeth. In such environment, establishing proper posterior support and harmonious anterior guidance and occlusal plane is recommended. In this case, the patient had excessively worn dentition with loss of posterior support, while denying surgical treatment due to her(his) history of osteoporosis, ibandronate injection, and risk of medication-related osteonecrosis of the jaw (MRONJ). To recover the vertical space needed for prosthetic restoration, full mouth rehabilitation with vertical dimension increase of remaining teeth was decided. Missing teeth in the posterior area were restored with mandibular removable partial denture. The treatment plan was determined through careful diagnosis, and every step of procedures including tooth preparation, provisional phase with the increased vertical dimension, and definitive prosthetic phase were carried out accordingly. Once the treatment was completed, the patient was satisfied functionally and esthetically. Periodic examination of oral hygiene, occlusal stability was conducted.