• 제목/요약/키워드: Fuel tank noise

검색결과 26건 처리시간 0.02초

KSR-III 로켓의 액체 연료 탱크 내에서 발생하는 슬로슁 현상의 배플에 의한 감쇄율 측정 (Measurment of Damping Ratio of Fuel Sloshing in Baffled Liquid Propellant Tank of KSR-III Rocket)

  • Park, Soon-Hong;Yoo, Joon-Tae
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.323.2-323
    • /
    • 2002
  • Sloshing of fuel in a liquid propellant tank is an important part of the dynamic and the stability analysis of the rocket. Baffles are installed in a propellant tank to reduce the instability due to sloshing. Multi degree of spring-mass-damper model was used to model sloshing of fuel in an axisymmetric tank. The natural frequencies and damping ratios are estimated. In order to verify the estimated natural frequencies and damping ratios, tests are performed for the real propellant tank of KSR-III with single ring baffle. Results of fuel sloshing analysis are compared with those of tests.

  • PDF

연료공급 장치의 진동 특성에 대한 연구 (A study on the characteristics of vibration in fuel pump system)

  • 권요섭;김찬묵;강태원;사종성;강태식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.494-500
    • /
    • 2007
  • The comfort and quietness of vehicle has been improved greatly due to the development of technology in automobile industry. It is driven by reduction on the level of vibration and noise in powertrain system. However, the hidden problems in automobile parts become noticeable since the vehicle has been better in overall performance. One of them is related to the fuel pump system. Therefore, this study is focused on investigating the characteristics of fuel pump and fuel tank first, and then comparing the data before and after installation of fuel pump system in a testing vehicle. Additionally, the measured data will be analyzed to identify the problems and find a solution to improve the level of noise and vibration in fuel pump system.

  • PDF

동하중을 받는 원통형 액화연료 탱크의 배플에 따른 슬로싱 저감 특성 (Sloshing Reduction Characteristics to Baffle for Cylindrical Liquefied Fuel Tank subject to Dynamic Load)

  • 구준효;조진래;정의봉;김당주
    • 한국소음진동공학회논문집
    • /
    • 제19권9호
    • /
    • pp.950-959
    • /
    • 2009
  • Liquid fluctuation called sloshing within liquid-storage tank gives rise to the significant effect on the dynamic stability of tank. This liquid sloshing can be effectively suppressed by installing baffles within the tank, and the suppression effect depends strongly on the design parameters of baffle like the baffle configuration. The present study is concerned with the parametric evaluation of the sloshing suppression effect for the CNG-storage tank, a next generation liquefied fuel for vehicles, to the major design parameters of baffle, such as the baffle configuration, the installation angle and height, the hole size of baffle. The coupled FEM-FVM analysis was employed to effectively reflect the interaction between the interior liquid flow and the tank elastic deformation.

유체-구조 연성 방법에 의한 단순 탱크 슬로싱 해석 (Sloshing Analysis of a Simple Tank using Fluid-structure Interface Method)

  • 강성종;서홍재;김병주
    • 한국기계가공학회지
    • /
    • 제10권4호
    • /
    • pp.31-37
    • /
    • 2011
  • Fuel tank sloshing noise of vehicle is caused by flow impact on the tank wall during sudden braking, and the sloshing vibration of tank wall is a coupled phenomenon of the fuel inside tank and tank wall structure. Therefore, Fluid-Structure Interface(FSI) analysis technology should be adopted to predict accurately the sloshing vibration. In this study, FSI approach was employed to analyze sloshing phenomenon for a simple tank model with velocity change of the actual vehicle test. First, the simulated results for rigid tank model were compared with those for deformable tank model. Next, influence of baffle location and shape of baffle holes on the acceleration magnitude and the maximum stress of tank wall was investigated. In addition, sloshing analysis for tank with another baffle type was carried out.

모달특성을 고려한 Fuel Tank의 손상도 계산 (Damage Value Calculation of Fuel Tank Considering Modal Characteristics)

  • 한우섭;박광서;김영호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.534-538
    • /
    • 2008
  • The vehicle system is exposed to random source in service. Therefore, it is important to consider dynamic effect of the system. But, fatigue analysis is traditionally performed by using time signal of loading. To obtain dynamic effect of resonance, we carried out resonance durability analysis with frequency response and the dynamic load on frequency domain. The study shows that the damage considering resonant frequency of fuel tank system can be effectively estimated.

  • PDF

LPLi 연료펌프의 맥놀이 소음 저감 연구 (Reduction of Beating noise at LPLi pump)

  • 강태식;심재기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.161-165
    • /
    • 2005
  • Until now LPG car has drived used to mixer and vaporizer. So LPG car always has problems back fire and when in the winter. LPG Car's Fuel consumption is rather than gasoline. But LPLi Fuel pump located in the fuel tank is directly injection in the engine. So Fuel consumption is better than LPG mixer system and result to reduced exhaust gas. In this paper to reduction of beating noise of LPLi(liquid phase LPG Injection) fuel pump. General speaking we know, beating noise is occur to near frequency each of pump. So we Modification of RPM through chang of amature turn number and area of dimension of the pump's body.

  • PDF

수치해석에 의한 심수 탱크구조물의 진동에 관한 연구 (Numerical Analysis of Vibration Characteristics in Deep Water Tank)

  • 배성용
    • 한국소음진동공학회논문집
    • /
    • 제13권10호
    • /
    • pp.791-797
    • /
    • 2003
  • A liquid storage rectangular tank structures are used In many fields of civil, mechanical and marine engineering. Especially, Ship structures have many tanks In contact with Inner or outer fluid, like ballast, fuel and cargo tanks. Fatigue damages are sometimes observed in these tanks which seem to be caused by resonance with exciting force of engine and propeller. Vibration characteristics of these thin walled tanks in contact with fluid near engine or propeller are strongly affected by added mass of containing fluid. Therefore it is essentially important to estimate the added mass effect to predict vibration of the tank structures. In the previous report, we have developed numerical tool of vibration analysis of 3-dimensional tank structure using finite elements for plates and boundary elements for fluid region. In the present report, using the numerical analysis, vibrations characteristics In deep water tank are investigated and discussed.

수치해석에 의한 심수 탱크구조물의 진동에 관한 연구 (Numerical Analysis of Vibration Characteristics in Deep Water Tank)

  • 배성용;홍봉기;배동명
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1079-1084
    • /
    • 2003
  • A liquid storage rectangular tank structures are used in many fields of civil, mechanical and marine engineering. Especially, Ship structures have many tanks in contact with inner or outer fluid, like ballast, fuel and cargo tanks. Fatigue damages are sometimes observed in these tanks which seem to be caused by resonance with exciting force of engine and propeller. Vibration characteristics of these thin walled tanks ill contact with fluid near engine or propeller are strongly affected by added mass of containing fluid. Therefore it is essentially important to estimate the added mass effect to predict vibration of the tank structures. In the previous report, we have developed numerical tool of vibration analysis of 3-dimensional tank structure using finite elements for plates and boundary elements for fluid region. In the present report, using the numerical analysis, vibrations characteristics in deep water tank are investigated and discussed.

  • PDF

CNG 탱크 내 연료량 계측을 위한 송·수신 초음파 센서의 접촉면 변경에 따른 수신 감도 분석 (Analysis of Receiving sensitivity according to Contact Surface Change of Transmit-Receiver Ultrasonic Sensor for Fuel Level Measurement in CNG Tank)

  • 김남욱;임석연;최두석
    • 한국융합학회논문지
    • /
    • 제9권4호
    • /
    • pp.137-142
    • /
    • 2018
  • 본 연구는 송 수신 초음파 센서를 이용하여 CNG 탱크에서의 정밀한 연료량을 측정하기 위한 기초 연구로써 탱크내부 압력 및 초음파 센서의 접촉면 변경에 따른 수신감도를 분석하였다. 실험은 탱크와 센서의 접촉면을 점, 선, 면의 3가지 타입으로 변경하고 탱크 내부의 압력을 0 bar 부터 5 bar까지 1 bar 간격으로 충전하면서 측정을 진행하였다. 실험결과 탱크내부의 압력이 증가함에 따라 초음파 센서의 수신신호 값이 감소하는 경향을 확인할 수 있었다. 또한 탱크와 센서의 접촉면적이 증가할수록 수신 신호 값은 증가하지만, 노이즈 또한 증가하는 것을 확인 할 수 있었다. 이와 같은 실험 결과 초음파의 투과 특성을 이용하여 탱크내부의 기체 연료량을 측정할 수 있을 것으로 판단되며, 센서의 접촉면 변경을 통해 정밀성을 향상시킬 수 있을 것으로 판단된다.