• 제목/요약/키워드: Fuel flow control

검색결과 385건 처리시간 0.027초

기체연료 엔진에서 공연비제어를 위한 흡입공기량 추정 (Estimation of Inlet Air Mass Flow for Air-Fuel Raito Control of Gaseous-Fuel Engines)

  • 심한섭;이강윤;선우명호;송창섭
    • 한국자동차공학회논문집
    • /
    • 제9권5호
    • /
    • pp.131-139
    • /
    • 2001
  • Highly accurate control of the air-fuel ratio is important to reduce exhaust gas emissions of the gaseous-fuel engines. In order to achieve this purpose, inlet air mass flow must be measured exactly, and precise engine models are necessary to design engine control systems. In this paper, the effects of water vapor and gaseous fuel that change the air mass flow are studied. The effective air mass ratio is defined as the air mass flow divided by the mixture mass flow, and also it is applied to the estimation of the inlet air mass flow. The presence of the gaseous fuel and the water vapor in the mixture reduces the air partial pressure and the effective air mass ratio of the gaseous-fuel engines. The Experimental results for an LPG engine show that the estimation of the inlet ai mass flow based upon the effective air mass ratio is more accurate than that of the normal air mass flow.

  • PDF

유량 제어 밸브 방식이 DME 고압 연료 펌프의 성능에 미치는 영향 (Effect of Flow Control Valve Type on the Performance of DME High Pressure Fuel Pump)

  • 신윤섭;이기수;김현철;정수진;박경용;서현규
    • 한국자동차공학회논문집
    • /
    • 제21권5호
    • /
    • pp.67-73
    • /
    • 2013
  • This experimental work described the effect of flow control valve type on the performance of wobble plate type fuel pump for the stable DME fuel supply. In order to study this, different four types of flow control valves (ITV, SCV, IMV and MPROP) were installed on the wobble plate fuel pump, and fuel flow rate, torque, and temperature variation of pump were investigated under various operating conditions by using pump performance test system. It was revealed that wobble plate type fuel pump worked well with ITV and SCV control valve, and the flow rate and torque of fuel pump was in proportion to the value of valve open duty. The maximum flow rate and torque of fuel pump were achieved around the 50% duty of control valve. Temperature variation at all pump measuring points were under $60^{\circ}C$ which is acceptable.

적분형 초음파 유량계를 이용한 MPI 엔진의 비정상상태 공연비 제어 (A/F Control of an MPI Engine on Transient Conditions with an Intergration type Ultrasonic Flow Meter)

  • 김중일;장준석;고상근
    • 한국자동차공학회논문집
    • /
    • 제7권9호
    • /
    • pp.36-47
    • /
    • 1999
  • Three-way catalyst converter, cleaning up the exhaust gas contamination of SI engine, has the best efficiency when A/F ratio is near the stoichiometry . The feedback control using oxygen sensors in the exhaust manifold has limits caused by the system delays. So the accurate measurement of air flow rate to an engine is essential to control the fuel injection rate especially on transient condition like the rapid throttle opening and closing. To measure the rapid change of flow rates. the air flow meter for the engine requires quick response, flow reversal detection, and linearity . Tjhe proposed integration type air flow meter (IFM), composed of an ultrasonic flow meter with an integration circuit, has significantly improved the measurement accuracy of air mass inducted through the throttle body. The proposed control method estimated the air mass at the cylinder port using the measured air mass at the throttle . For the fuel dynamic model, the two constant fuel model is introduced . The control parameters from air and fuel dynamics are tuned to minimize the excursion of the air fuel ratio. As a result A/F ratio excursion can be reduced within 5% when throttle rapidly opens and closes at the various engine conditions.

  • PDF

하나로 핵연료 시험 루프 주냉각수 계통의 유량 제어에 대한 유동 해석 (Flow Network Analysis for the Flow Control of a Main Cooling Water System in the HANARO Fuel Test Loop)

  • 박용철;이용섭;지대영
    • 한국유체기계학회 논문집
    • /
    • 제12권5호
    • /
    • pp.7-12
    • /
    • 2009
  • A nuclear fuel test loop(after below, FTL) is installed in the IRI of an irradiation hole in HANARO for testing the neutron irradiation characteristics and thermo hydraulic characteristics of a fuel loaded in a light water power reactor or a heavy water power reactor. There is an in-pile section(IPS) and an out-pile section(OPS) in this test loop. When HANARO is operated normally, the fuel loaded into the IPS has a nuclear reaction heat generated by a neutron irradiation. To remove the generated heat and to maintain the operation conditions of the test fuel, a main cooling water system(MCWS) is installed in the OPS of the FTL. The MCWS is composed of a main cooler, a pressurizer, two circulation pumps, a main heater, an interconnection pipe line and instruments. The interconnection pipeline is a closed loop which is connected to an inlet and an outlet of the IPS respectively. The MCWS is under a cold function test during a start-up period. This paper describes the system flow network analysis results of the flow control of a main cooling water system in the HANARO fuel test loop. It was confirmed through the results that the flow was met the system design requirements.

흡기포트 분사식 LPG 엔진의 연료량 제어 및 연소 특성에 관한 연구 (A Study on the Combustion Characteristics and the Control on the Fuel Flow Rate of LPG Intake Port Injection Engine)

  • 김우석;이종화;정창현
    • 한국자동차공학회논문집
    • /
    • 제8권6호
    • /
    • pp.31-39
    • /
    • 2000
  • In this paper, characteristics of a port injection type LPG fuel system were investigated to adopt the system to a spark ignition engine through rig test. Engine combustion characteristics for limited conditions and the precise control method of LPG fuel supply were also studied. As a basic experiment, the effects and the relationships of parameters such as orifice area, fuel delivery pressure, fuel temperature and flow coefficient were established. From this, one dimensional compressible flow equation can be applied to control gaseous fuel flow rate by setting pressure difference between vaporizer and manifold to a certain range, for example about 1.2 bar in a naturally aspirated engine. The combustion analysis results of LPG engine were also compared with those of gasoline engine according to spark timing and load change. At part load and stoichiometric condition, the MBT spark timing of LPG fueled engine is retarded by 2$^{\circ}$ - 4$^{\circ}$CA compared to that of gasoline engine. On the contrary, the spark timing of LPG fueled engine can be advanced by 5$^{\circ}$- 10$^{\circ}$ CA at WOT, which results from higher Octane Number and burned fraction of LPG fuel compared to gasoline.

  • PDF

가솔린 기관 공연비 제어를 위한 흡기포트 내의 연료액막 모델링 (Modeling of Liquid Fuel Behavior to Control Air/Fuel Ratio in the Intake Port of SI Engines)

  • 조훈;민경덕;황승환;이종화
    • 대한기계학회논문집B
    • /
    • 제24권4호
    • /
    • pp.512-518
    • /
    • 2000
  • A wall fuel-film flow model is developed to predict the effect of a wall-fuel-film on air-fuel ratio in an SI engine in transient conditions. Fuel redistribution in the intake port resulting from charge backflow and a simple liquid fuel behavior in the cylinder are included in this model. Liquid fuel film flow is calculated of every crank angle degree using the instantaneous air flow rate. The model is validated by comparing the calculated results and corresponding engine experiment results of a commercial 4 cylinder DOHC engine. The predicted results match well with the experimental results. To maintain the constant air-fuel ratio during transient operation. the fuel injection rate control can be obtained from the simulation result.

관류형 보일러의 온도제어 (Temperature control for once through boiler)

  • 김은기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.900-904
    • /
    • 1991
  • It is important and difficult to control the steam temperature in the once through boiler. Generally, steam temperature of once through boiler not only is controlled by boiler spray water flow, but also is influenced by feed water flow and fuel flow. So we have to make the same gain of fuel flow controller and feed water flow controller. This paper is shown the design and test of steam temperature and feed water flow control system for once through boiler in pusan thermal power plant.

  • PDF

왕복유동을 이용한 확산증대 효과에 대한 연구 (Enhanced diffusion by using pulsating flow)

  • 황용신;이대영;김서영;최훈;차석원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.538-541
    • /
    • 2008
  • This study considers the feasibility of the concentration control of the feul and air by oscillating flow in the channel of Fuel Cells. Fuel Cell Stack performance is largely influenced by the fuel and air concentration. If the fuel and air concentration is lower than stoichiometry 1.25 of the fuel and 2.5 of the air, its performance deteriorates seriously because of the fuel and air starvation. In this respect the optimization of the fuel and air concentration is crucially important to maximize fuel cell stack performance. In this work, the effects of oscillating actuation are studied to control the concentration. Two important nondimensional parameters are introduced, each of which represents either the oscillating frequency or the oscillating amplitude. It is shown how these factors affect the stack performance and the efficiency of the fuel cell stack stack.

  • PDF

연료극 왕복유동이 직접 메탄올 연료전지에 미치는 영향에 대한 해석적 연구 (Analytical Study on the Oscillating Flow Effect in a Anode Channel of Direct Methanol Fuel Cells)

  • 황용신;이대영;김서영;최훈;차석원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.27-30
    • /
    • 2007
  • This study considers the feasibility of the concentration control of the methanol solution by oscillating flow in the anode channel of passive type Direct Methanol Fuel Cells(DMFC). DMFC stack performance is largely influenced by the fuel concentration. If the fuel concentration is either lower than 0.5M or more than 2M, its performance deteriorates seriously because of the fuel starvation or the fuel crossover. In this respect the optimization of the fuel concentration is crucially important to maximize the DMFC stack performance. In this work, the effects of oscillating actuation in the fuel supply are studied to control the fuel concentration. Two important nondimensional parameters are introduced, each of which represents either the oscillating frequency or the oscillating amplitude. It is shown how these factors affect the stack performance and the efficiency of the DMFC stack.

  • PDF

최신 전투기 사례를 통한 T-50 FFP 시스템 최적 설계 연구 (A Study on Optimal design of T-50 Aircraft FFP system through a case of F-16 Aircraft)

  • 남용석;김태환;정년수
    • 항공우주시스템공학회지
    • /
    • 제4권1호
    • /
    • pp.10-14
    • /
    • 2010
  • The Fuel system of T-50 Advanced Trainer is equipped with two boost pump and fuel flow proportioner for feeding fuel to turbo jet engine. when an unexpected failure occurs, they can feed the fuel to turbo jet engine which fuel quantity required. fuel quantity control method is applied for minimizing the center of gravity change. and fuel quantity control method is controlled by FQMS(Fuel Quantity Measuring System) and FFP(Fuel Flow Proportioner). This paper presents life cycle extension plans of FFP hydraulic motor by design improvements of connecting and arrangement of pipe comparing with KF-16.

  • PDF