• 제목/요약/키워드: Frosting

검색결과 82건 처리시간 0.024초

착상에 의한 휜관형 열교환기의 성능변화에 관한 실험적 연구 (Experimental Study on the Performance Change of the Fin and Tube Type Heat Exchanger by the Frosting)

  • 김정국;소산번;상원헌;박병덕;김동휘;사용철
    • 설비공학논문집
    • /
    • 제21권2호
    • /
    • pp.79-86
    • /
    • 2009
  • The present study was investigates the effect of the parameters on the frost formation and heat transfer performance such as fin shape, air temperature and air velocity. Heat transfer rate and pressure drop by frost were experimentally investigated. Effect of the wet blub temperature and air velocity on the heat transfer performance has been also investigated. The heat transfer performance of the louver fin and tube type heat exchanger was higher by maximum of 0.85% than the corrugate fin type at the air temperature of $2.0/1.5^{\circ}C$. As the wet blub temperature of air were increased, the heat transfer rate, pressure drop and mass of frost of three test models were increased. Especially, the maximum heat transfer rate and maximum pressure drop were shown for the Type B louver fin heat exchanger. As an experimental result, the enhancement factor(EF) of louver fin and tube type heat exchanger was only $0.2{\sim}0.4$ due to the high pressure drop.

도로포장의 효율적 동상방지층 설계를 위한 현장 계측자료의 데이터베이스(DB) 구축 (An Establishment of Database for Effective Design of Anti-Frost Heave Layer using Field Data)

  • 김낙석;남영국;조규태;이범우
    • 한국방재학회 논문집
    • /
    • 제11권3호
    • /
    • pp.43-47
    • /
    • 2011
  • 우리나라는 겨울철에 동결된 상태로 있다가 봄에는 해빙되는 계절적 동토지역이다. 이러한 계절적 특성으로 인하여 겨울에서 봄에 이르기까지 도로포장의 동결 융해가 반복되어 도로 파손을 유발 시키고 있다. 동결 융해로 인한 피해를 줄이기 위하여 도로포장 설계 시 노상이 동결하는 것을 방지하기 위한 동상방지층을 별도로 설치를 하고 있으나 실효성 검증 없이 국외 연구 결과에 따른 시방서를 바탕으로 무분별하게 적용되고 있어 국가적으로 예산을 낭비하고 있는 실정이다. 본 연구에서는 동결지수 선도를 따라 선정된 15개 지역의 성토부 2 m 이하, 절토부, 절성경계부 구간에서 계측된 온도 및 함수비 데이터들을 효율적으로 관리하고 모니터링 하기위한 데이터베이스를 구축하고자 하였다. 연구결과 계측자료의 효율적인 저장 및 관리가 가능한 데이터베이스를 구축하여 도로설계 기술자의 손쉬운 계측 자료 검색 및 다운로드가 가능하게 되었다.

Flutter phenomenon in composite sandwich beams with flexible core under follower force

  • Saghavaz, Fahimeh Rashed;Payganeh, GHolamhassan;Fard, Keramat Malekzadeh
    • Steel and Composite Structures
    • /
    • 제39권5호
    • /
    • pp.615-630
    • /
    • 2021
  • The main purpose of the present work was to study the dynamic instability of a three-layered, thick composite sandwich beam with the functionally graded (FG) flexible core subjected to an axial compressive follower force. Flutter instability of a sandwich cantilever beam was analyzed using the high-order theory of sandwich beams, for the first time. The governing equations in general for sandwich beams with an FG core were extracted and could be used for all types of sandwich beams with any types of face sheets and cores. A polynomial function is considered for the vertical distribution of the displacement field in the core layer along the thickness, based on the results of the first Frosting's higher order model. The governing partial differential equations and the equations of boundary conditions of the dynamic system are derived using Hamilton's principle. By applying the boundary conditions and numerical solution methods of squares quadrature, the beam flutter phenomenon is studied. In addition, the effects of different geometrical and material parameters on the flutter threshold were investigated. The results showed that the responses of the dynamic instability of the system were influenced by the follower force, the coefficients of FGs and the geometrical parameters like the core thickness. Comparison of the present results with the published results in the literature for the special case confirmed the accuracy of the proposed theory. The results showed that the follower force of the flutter phenomenon threshold for long beams tends to the corresponding results in the Timoshenko beam.

덕트형 항온챔버에서 히트펌프 실외기의 성능평가 가능성에 대한 CFD (CFD on the possibility of performance evaluation of heat pump outdoor unit in duct-type constant temperature chamber)

  • 김종열
    • 융합신호처리학회논문지
    • /
    • 제22권3호
    • /
    • pp.116-121
    • /
    • 2021
  • 에너지를 절약하기 위해 고효율 히트펌프를 개발하기 위한 많은 연구가 이루어지고 있으며, 실외기 코일에 발생하는 서리가 발생하는 현상을 줄이거나 없애기 위한 연구도 동시에 이루어지고 있다. 계절과 관계없이 히트펌프의 실외기에 서리가 발생하지 않는 연구를 진행할 수 있도록 자연 상태와 동일한 조건에서 실험할 수 있는 곡선형 항온챔버를 구축하였다. 이러한 곡선형 항온챔버가 실험 장치로서 타당성을 갖추고 있는지 검증하기 위해 시뮬레이션을 하였다. CFD 조건은 곡선형 항온챔버 내에 위치한 실외기 앞의 직선형 덕트 길이를 덕트 관경의 1배, 5배, 10배, 15배로 하였다. 그 결과 덕트 관경의 10배 길이로 시뮬레이션했을 때 자연 상태와 가장 유사하다는 것을 알게 되었다.

공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • 설비공학논문집
    • /
    • 제12권12호
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF

나선형 핀-튜브 증발기를 적용한 냉장고의 성능 특성에 관한 연구 (Study on Performance Characteristics of Spiral Fin-Tube Evaporator Applied to Domestic Refrigerator-Freezers)

  • 이상헌;윤원재;김용찬;이무연;윤성중
    • 대한기계학회논문집B
    • /
    • 제37권3호
    • /
    • pp.205-212
    • /
    • 2013
  • 본 연구는 평판 핀-튜브 증발기와 나선형 핀-튜브 증발기를 적용한 가정용 냉장고의 성능특성 비교를 통하여 기존에 사용하고 있는 핀-튜브 증발기를 나선형 핀-튜브 증발기로 대체할 수 있는 가능성을 고찰하는데 그 목적이 있다. 실험은 2단 15열의 평판 핀-튜브 증발기와 2단 15열에서 2단 11열까지 열 수를 단계적으로 감소시킨 3종류의 나선형 핀-튜브 증발기를 실제 냉장고에 적용하여 수행하였다. 핀-튜브 증발기의 열 수가 감소할수록 냉동시스템의 최적 냉매 충전량은 감소하였으며, 2단 13열과 2단 11열의 나선형 핀-튜브 증발기를 장착한 냉장고의 소비전력은 기존 2단 15열의 평판 핀-튜브 증발기를 적용한 냉장고 대비 각각 1.5%와 2.8% 감소하였다. 또한 내착상 실험결과 나선형 핀-튜브 증발기가 기존 평판 핀-튜브 증발기와 비교하여 같은 착상조건에서 3~7% 향상된 냉각능력을 보였다. 냉각속도 실험에서는 모든 증발기는 동등수준의 성능을 나타내었다.

타블렛 형태 급결제가 콘크리트의 응결시간 및 조기강도에 미치는 영향에 관한 연구 (A Study on Setting Time and Early Strength of Tablet-Shaped Accelerators)

  • 류재석;이용수
    • 콘크리트학회논문집
    • /
    • 제23권3호
    • /
    • pp.347-352
    • /
    • 2011
  • 한중 콘크리트 타설시 발생되는 초기 동해로 인한 피해를 방지하고 조강성을 향상시키기 위해 열풍기 사용을 통한 보양, 결합수와 골재의 가열 및 시멘트 사용량을 늘리는 방법, 급결제 및 촉진제를 사용하는 등 다양한 방법이 사용되고 있다. 하지만 이러한 방법은 사용상의 어려움과 에너지 소비 및 생산비의 증가에 따른 경제성 감소 등의 문제점을 가지고 있다. 이중 급결제 및 촉진제의 사용은 경제적 이지만 수화 초기부터 급격하게 반응하여 급결하는 특성 때문에 작업성의 확보가 어렵다는 문제점을 가지고 있다. 이에 이 논문에서는 기존 의약 분야에서 주로 이용되는 약물의 고형 투여 형태인 정제(Tablet)화 방법을 이용하여 급결제와의 응결 시간을 비교하였고, 이 결과를 토대로 콘크리트의 물리적 특성 및 역학적 특성 시험을 실시하여 일정 시간 동안 작업이 가능하고 초기동해 방지 및 조강성이 향상 되는지 확인 하였다. 그 결과 급결제 및 타블렛의 경우 사용량이 증가 할수록 응결 시간이 줄어드는 것을 확인하였고, 콘크리트의 물리적 역학적 시험에서는 경시 변화에 대하여 Control과 비교 타블렛0.5%, 1.0%가 일정 시간 동안 작업 시간 확보가 가능함을 확인하였을 뿐만 아니라 조기 강도에서도 급결제 0.5%와 타블렛 0.5%, 1.0%가 뛰어난 조기 강도 발현 특성을 보여주었다.

반죽의 냉동과 저장 조건에 따른 빵의 품질 특성 (Quality Characteristics of Wheat Flour Breads with the Doughs Frozen at the Different Freezing and Storage Conditions)

  • 고봉경
    • 한국식품과학회지
    • /
    • 제34권3호
    • /
    • pp.413-418
    • /
    • 2002
  • 제빵에 이용 할 반죽을 발효하거나 발효하지 않은 상태로 다섯 가지의 다른 냉동 및 저장 환경에서 냉동하고 일주일간 저장하여 해동 한 후 제조된 빵의 품질을 비교하였다. 냉동속도가 빠르더라도 발효한 후 냉동된 반죽은 빵의 부피가 감소하였으며 이러한 문제점은 침지식 냉동 방식에서도 해결되지 않았다. $-70^{\circ}C$의 초저온 냉동은 $-20^{\circ}C$ 침지식 냉동고에 비하여 냉동 온도가 매우 낮으나, 냉동 속도도 느리고 해동 후 재 발효하여도 빵의 부피가 작아서 효과적인 냉동 방법이 되지 못하였다. 반면 냉동 속도는 느리지만 $-20^{\circ}C$ 공기 송풍식 냉동고가 $-70^{\circ}C$ 공시 송풍식 냉동고보다 냉동에 따른 장해가 적어서 반죽의 발효가 잘되었다. 동일한 온도일 때는 침지식 냉동이 더욱 효과적이었으며 침지식 가운데도 온도가 더 높은 $-10^{\circ}C$ 냉동이 가장 효과적이어서 발효하지 않고 냉동하여 재 발효 할 경우 대조구보다도 오히려 반죽의 발효가 잘되어 빵의 부피가 더 컸다. 따라서 본 연구에 이용한 방법 가운데 $-70^{\circ}C$ 공기 송풍식 냉동고에서 냉동, 저장하는 것이 가장 비효율적이며 침지식 냉동방법들이 냉동 온도가 높더라도 오히려 해동 후 발효 장해가 적어서 효율적이었다. 위의 실험 결과를 종합하였을 때, 냉동 전에 반죽을 발효하지 않고 $-10^{\circ}C$ 침지식 냉동고에서 냉동하여 저장하거나, $-20^{\circ}C$ 침지식 냉동고에서 초기에 냉동을 하고, $-20^{\circ}C$ air freezer에 저장하는 방법이 가장 효과적이었다.

동결 및 해동중의 연시의 품질변화 (Changes in Quality of Soft Persimmon during Freezing and Defrosting)

  • 성전중;노영균;박석희;변효숙;함영진;최종욱
    • 한국식품저장유통학회지
    • /
    • 제6권4호
    • /
    • pp.398-401
    • /
    • 1999
  • 경북 상주지역에서 가장 많이 재배되고 있는 둥시와 청도지역의 대표적인 반시를 공시하여 동결감의 제조 및 해동중에 일어나는 품질변화를 구명하기 위하여 연구한 결과, 동결감 과육의 온도변화는 -4$0^{\circ}C$까지 도달하는 시간이 상주둥시보다 청도반시가 10~20분 더 소요되었고 감은 -2$^{\circ}C$~3$^{\circ}C$에서 동결되었다. 동결저장중의 파열과 발생은 상주둥시가 24.5%, 청도반시가 15.5%로 청도반시가 상주둥시보다 상대적으로 적게 파열되어 동결감 제조시 청도반시가 더 유리하였다. 해동온도별 경도변화는 상주둥시 5$^{\circ}C$에서 150분, 청도반시 120분이 소요되었고 1$0^{\circ}C$, 2$0^{\circ}C$, 3$0^{\circ}C$로 해동할 경우 현저히 해동시간을 단축할 수 있었다. 해동온도별 해동전후의 색도의 변화는 L값은 해동전과 비교하여 약간 감소하였으나, a, b값은 급격히 어두운 갈색으로 변하는 경향을 보였다. 동결감 제조시기별 당도의 변화는 수확, 연시, 동결, 해동 단계별로 두 품종 공히 별다른 변화를 보이지 않았다. 완전해동시까지의 도달시간은 상온에서(10.9~14.8$^{\circ}C$)상주둥시가 4시간 30분, 청도반시는 4시간 20분 소요되었다.

  • PDF

설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009)

  • 한화택;이대영;김서영;최종민;백용규;권영철
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.