An Experimental Study on the Frost Resistance of High-Flowing Concrete Using Granulated Blast-Furnace Slag (고로슬래그 미분말을 사용한 고유동콘크리트의 내동해성에 관한 실험적 연구)

  • 김무한;권영진;강석표
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.2
    • /
    • pp.43-51
    • /
    • 2000
  • This study is to investigate for the frost resistance of high-flowing concrete using finely ground granulated blast-furnace slag with experimental parameters, such as type of binder, type of superplasticizer and method of curing. The resistance to freezing and thawing of high-flowing concrete by type of binder and superplasticizer is presented differently. Though the frost resistance of high-flowing concrete is satisfactory under standard condition, it is required that high-flowing concrete has entrained air like plain concrete. Because the critical spacing factor, being capacity of frost resistance, of high-flowing concrete is longer that of plain concrete, the frost resistance of high-flowing concrete, using finely ground granulated furnace blast slag, is superior to that of plain concrete.

Frost resistance of porous concrete assuming actual environment (實環境を考慮したポーラスコンクリートの耐凍害性の評価(실제 환경을 고려한 다공질 콘크리트의 내동해성(耐凍害性) 평가))

  • NAKAMURA, Takuro;HORIGUCHI, Takashi;SHIMURA, Kazunori;SUGAWARA, Takashi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.227-233
    • /
    • 2008
  • Porous concrete has large continuous voids of 20-30 % by volume, and this concrete is attractive as environmental material in Japan i.e. permeable road pavement, river bank protection with vegetation and green roof system which influence thermal environment. It is necessary to confirm the frost resistance when constructing porous concrete structure in cold region. However applicable test method and evaluation criterion of porous concrete has not defined yet. Therefore, the object of this study is to investigate the frost resistance of porous concrete and this investigation attempts to address this concern by comparing 4 kinds of specified freezing and thawing tests methods (JIS A1148 procedure A/B and RILEM CIF/CDF test) in consideration of actual environment. RILEM freeze-thaw tests are different from JIS A1148 freeze-thaw tests, which are widely adopted for evaluating the frost resistance of conventional concrete in Japan, in water absorption, cooling rate, length of freezing and thawing period, and number of freezing and thawing cycles. RILEM CIF test measures internal damage and is primarily applicable for pure frost attack. CDF test is appropriate for freeze-thaw and de-icing salt attack. JIS A1148 procedure A/B showed extremely low frost resistance of porous concrete if the large continuous voids were filled with water and the ice expansion in the large continuous voids set in during cooling. Frost resistance of porous concrete was improved by mixing coarse aggregate (G7) which particle size is smaller and fine aggregate in JIS freezing and thawing tests. RILEM CIF/CDF test showed that freeze-thaw and de-icing resistance of porous concrete was seems to be superior in that of conventional concrete.

  • PDF

Heat and Mass Transfer of Parallel Plate Heat Exchanger under Frosting Condition (착상조건하에서 평행 평판 열교환기의 열 및 물질전달)

  • Lee, K.S.;Lee, T.H.;Kim, W.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.155-165
    • /
    • 1994
  • In this study, the following factors are investigated from experiments for a vertical parallel plate heat exchanger under the frosting condition ; the growth of frost layer, the characteristics of heat and mass transfer, the change of mass flow rate of the air passing through the heat exchanger, and the pressure drop of the air in the heat exchanger. The amount of heat and mass flux of water vapor transferred from the air stream to the heat exchanger surface is large at the early stage of frosting and then decreases dramatically, and the extent of decreasing rate becomes moderate with time. The frost layer formed near the inlet of the heat exchanger is thicker and denser than that formed near the outlet. It is found that the gradient of the amount of frost along the flow direction increases with time. In the early period of frost formation, the thermal resistance between the air and the cooling plate increases dramatically and then the extent of change decreases with time. Initially the convective thermal resistance is dominant. Then, while the convective thermal resistance decreases with time, the conductive thermal resistance continues to increase with time and finally the conductive thermal resistance becomes dominant.

  • PDF

The Effect of Operating Conditions on the Frost Formation in a Vertical Plate at a Low Temperature (저온 수직평판에서 착상에 대한 운전조건의 영향)

  • 이관수;이태희;김우승
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.12
    • /
    • pp.3305-3314
    • /
    • 1994
  • In this study, the influence of a frost formed on the vertical plate for different operating conditions(the temperature of the air, the humidity of the air, the velocity of the air, and the temperature of the cooling plate) is investigated. The performance of the heat exchanger is examined by introducing a parameter such as the energy transfer resistance. Correlations which relate frost density, frost thickness and energy transfer resistance to Reynolds number, air temperature and humidity, and cooling plate temperature are developed. Static pressure drop and air flow rate are expressed as a function of free flow area of air.

An Experimental Study on the Frost Resistance of High-Strength Concrete using Blast-Furnace Slag (고로슬래그를 이용한 고강도콘크리트의 내동해성에 관한 실험적 연구)

  • 박선규;유재강;강석표;권영진;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.671-674
    • /
    • 1999
  • With increasing content of granulated blase furnace slag in cement, the content of capillary pores in the mortar decreases and later age strength of the concrete. Therefore, this provides greater reserves study is carried out to estimate frost resistance of high-strength concrete specimens with water cement ratios using blast-furnace slag. 1. Blast furnace concrete is comparatively more good frost resistance than normal concrete. 2. As the blast furnace slag increases, the quantity of pores with a radius of more than 30nanometer decreses.

  • PDF

Frost Resistance of Concrete with Antifreezers and Superplasticizers at Early age (고성능 감수제와 방동제를 사용한 콘크리트의 초기 동해 저항성능)

  • 박찬규;한광재
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.195-200
    • /
    • 2002
  • In this paper, the effects of type and content of antifreezer on the frost resistance of concrete at early age were investigated. For this purpose, 4 types of antifreezer and 2 types of superplasticizer were selected, and based on the strength recovery ratio, the frost resistance of concrete was estimated. The optimum concrete mixes were also produced when the curing temperatures were -5 and -10$\{circ}{c}$.

  • PDF

An Experimental Study on the Early Frost Resistance Properties of High-Strength Concrete in Winter Concreting (동절기 고강도콘크리트의 시공에 있어서 초기동해 방지에 관한 실험적 연구)

  • 권영진
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.76-81
    • /
    • 2001
  • Recently, the structure is higher and larger, so that the application of high-strength concrete is increased, And as the development of construction skills, it is possible to place during the winter. Concrete work during winter is indispensible to shorten time of completion and cut costs. When concrete work during winter is placed, it has anxiety that concrete freeze at low temperature. As repetition of concrete's freezing cause reduction of durability, it is necessary for mixing to pay attention to air content and W/C ratios. Accordingly, in this study, we estimate the frost resistance by air content and W/C ratios, and development of strength after early-frost damage in the high-strength concrete during the cold weather. In this study, it could be confirmed that factors which were air content, W/C ratios and early curing period, affected on the frost resistance.

  • PDF

Experimental Study on Frost Resistance of High-Strength Concrete Using Granulated Blast-Furnace Slag (고로슬래그 미분말을 흔입한 고강도콘크리트의 내동해성에 관한 실험적 연구)

  • 김무한;권영진;강석표;박선규
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.4
    • /
    • pp.41-48
    • /
    • 2000
  • This study is to investigate for the frost resistance of high-strength concrete using finely ground granulated blast-furnace slag with experimental parameters, such as water/binder ratio, replacement proportion of granulated blast-furnace slag, air content and methods of curing. The high-strength concrete using granulated blast-furnace slag is effective to resist frost and decrease scaling. The more increasable replacement proportion of granulated blast-furnace slag is, the better the effect is. The high-strength concrete using granulated blast-furnace slag needs hydrating adequately to prevent deterioration by drying in the early curing period. The micro structure of high-strength concrete, increased to the pore number with diameter of 0.03~0.1mm, is changed by using granulated blast-furnace slag, but is presented differently according to water/binder ration and replacement proportion of granulated blast-furnace slag.

Evaluation on Surface Scaling and Frost Resistance for concrete Deteriorated due to Cyclic Freezing and Thawing with Inherent Chloride

  • Kim, Gyu Yong;Cho, Bong Suk;Lee, Seung Hoon;Kim, Moo Han
    • Corrosion Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.177-185
    • /
    • 2007
  • The purpose of this study is to evaluate freezing-thawing and surface scaling resistance in order to examine the frost durability of concrete in a chloride-inherent environment. The mixing design for this study is as follows: 3 water binder ratios of 0.37, 0.42, and 0.47; 2-ingredient type concrete (50% OPC concrete and 50% ground granulated blast-furnace slag), and 3-ingredient type concrete (50% OPC concrete, 15% fly ash, and 35% ground granulated blast-furnace slag). As found in this study, the decrease of durability was much more noticeable in combined deterioration through both salt damage and frost damage than in a single deterioration through either ofthese; when using blast-furnace slag in freezing-thawing seawater, the frost durability and surface deterioration resistance was evaluated as higher than when using OPC concrete. BF 50% concrete, especially, rather than BFS35%+FA15%, had a notable effect on resistance to chloride penetration and freezing/expansion. It has been confirmed that surface deterioration can be evaluated through a quantitative analysis of scaling, calculated from concrete's underwater weight and surface-dry weight as affected by the freezing-thawing of seawater.

Strength Development and Freeze-Thaw Resistance of Concrete Incorporating High Volume Blast-Furnace Slag Subjected to Initial Frost Damage (초기동해를 받은 고로슬래그 다량 혼입 콘크리트의 강도발현 및 동결융해 저항성)

  • Koh, Kyung-Taek;Ryu, Gum-Sung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.3
    • /
    • pp.79-87
    • /
    • 2011
  • Concrete incorporating high volume blast-furnace slag placed in cold weather regions might be in danger of initial frost damage because dependently on the mix proportions, the setting and the hardening would be remarkably delayed. Therefore, this study investigated to effect of the degree of frost on the strength development and the resistance to freezing and thawing of the concrete incorporating blast-furnace slag when being subjected to freeze at early age. As the experimental results, the concrete incorporating blast-furnace slag attacked by initial frost damage showed the remarkable reduction of both the compressive strength development and the resistance to freezing and thawing. Especially, the resistance to freezing-thawing of the concrete incorporating high volume blast-furnace slag became much lower than that of the normal concrete.

  • PDF