• Title/Summary/Keyword: Frost formation

Search Result 68, Processing Time 0.019 seconds

Stiffness change measurement for subgrade soils at freezing and thawing using impact resonance test (충격공진시험을 이용한 노상토의 동결.융해시 강성도 변화 측정)

  • Lee, Jae-Hoan;Kweon, Gi-Chul
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.686-691
    • /
    • 2009
  • Damage due to frost action in pavement structure system is creating either frost heave or stiffness-weakening of subgrade soil follow melting. The formation of ice lenses requires a frost-susceptible soil, freezing temperatures, and continuous water supply. Eliminating one of these conditions suffices to significantly reduce the intensity of frost action. It is important to know characteristics of subgrade soil in frost susceptibility or decide degree of freezing permission. Also, study on the stiffness variation of subgrade soil during freezing and thawing cycle is very important. In this study, Impact resonance test for subgrade soil at freezing and thawing confirms that is applied for.

  • PDF

Characteristic of Frost Formed on Thermally Conductive Plain Plastic Plate

  • Lee Jang-Seok;Lee Kwan-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.3
    • /
    • pp.138-144
    • /
    • 2005
  • In order to select a new material for a heat exchanger, the frosting behavior of a thermally conductive plastic based on PBT was compared to the frosting behavior of aluminum and three types of plastics based on PTFE. The frosting behavior on the 1 mm thick PBT specimen was similar to that of the aluminum specimen but not that of the pure PTFE specimen. The properties of the frost formed on the specimens were affected by both the thermal conductivity and surface characteristics of the materials. The heat and mass transfer rates of the thermally conductive plastic were almost equivalent to those of the aluminum specimen.

Experimental Study for Development of Air Eject Defrost Equipment (공기분사식 제상장치 개발에 관한 실험적 연구)

  • Han, In-Geun;Kim, Chang-Yeong;Kim, Jae-Dol;Yun, Jeong-In
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.3
    • /
    • pp.277-284
    • /
    • 2001
  • One of the problems in a refrigerator operation is the frost formation on a cold surface of the evaporator. The frost layer is formed by the sublimation of water vapor when the surface temperature is below the freezing point. This frost layer is usually porous and formed on the cold surface of the evaporator. The frost layer on the surface of a evaporator will make side effect such as thermal resistance. However, these important factors have not been used in determining the defrosting period. Therefore, the proper defrosting operation period based on the new defrosting method is very important, and make a comparison between conventional method like electric defrost and new method in compression work, evaporation pressure, evaporation temperature.

Minimum Curing Time Prediction of Early Age Concrete to Prevent Frost Damage (동해방지를 위한 초기재령 콘크리트의 최소 양생 시간 예측)

  • Pae, Su-Won;Yi, Seong-Tae;Kim, Jin-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.1
    • /
    • pp.27-37
    • /
    • 2007
  • The purpose of this study is to propose a method to predict the minimum curing time of early age concrete required to prevent frost damage. Tests were performed to examine major factors, which affect the compressive strength of concrete frozen at early ages and investigate the source of frost damage at early age concrete. The results from the tests showed that the loss rate of compressive strength decreases as the beginning time of frost damage was delayed and water-cement ratio was lower. In addition, the test results also showed that concrete made with type III cement was less susceptible to frost damage than concrete made with ordinary Portland cement and frost damage occurred through the formation of ice lenses. When early age concrete is being damaged by frozen, a phase transition into ice of free water presented at the capillary pores of the concrete gives a reason for the decrease of compressive strength. Accordingly, the frost resistance of fresh concrete can be determined based on the saturation degree of the capillary pores. The method to predict the minimum curing time was suggested using the concept of critical saturation degree of the capillary pores.

An Experimental Study on the Effects of Design Factors for the Performance of Fin-Tube Heat Exchanger Under Frosting Conditions (착상시 설계인자에 따른 핀-관 열교환기의 성능변화에 관한 실험적 연구)

  • 이관수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.10
    • /
    • pp.2657-2666
    • /
    • 1995
  • In this study, the effects of design factors of finned-tube heat exchanger, such as fin spacing and fin array on the frost growth and heat exchanger performance are investigated under a frosting condition. The results show that the amount of frost, frost density and blockage ratio of air flow passage increase with decreasing fin spacing. Heat transfer rate increases momentarily at the initial stage of frosting and then decreases. After that heat transfer rate continues to increase again to reach a maximum value and then decreases dramatically. It is shown that the time required for heat transfer rate to reach a maximum value becomes shorter with decreasing fin spacing, and after a maximum value, heat transfer rate decreases very fast. The maximum allowable blockage ratio is introduced to determine the operation limit of a finned-tube heat exchanger operating under frosting condition and is obtained as a function of fin spacing. It is also shown that heat transfer rate of heat exchanger with staggered fin array increases about 17% and the amount of pressure drop of air increases about 1~2 mmH$_{2}$O, compared with those of in-line type heat exchanger under frosting condition.

Improvement of Multiple-sensor based Frost Observation System (MFOS v2) (다중센서 기반 서리관측 시스템의 개선: MFOS v2)

  • Suhyun Kim;Seung-Jae Lee;Kyu Rang Kim
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.25 no.3
    • /
    • pp.226-235
    • /
    • 2023
  • This study aimed to supplement the shortcomings of the Multiple-sensor-based Frost Observation System (MFOS). The developed frost observation system is an improvement of the existing system. Based on the leaf wetness sensor (LWS), it not only detects frost but also functions to predict surface temperature, which is a major factor in frost occurrence. With the existing observation system, 1) it is difficult to observe ice (frost) formation on the surface when capturing an image of the LWS with an RGB camera because the surface of the sensor reflects most visible light, 2) images captured using the RGB camera before and after sunrise are dark, and 3) the thermal infrared camera only shows the relative high and low temperature. To identify the ice (frost) generated on the surface of the LWS, a LWS that was painted black and three sheets of glass at the same height to be used as an auxiliary tool to check the occurrence of ice (frost) were installed. For RGB camera shooting before and after sunrise, synchronous LED lighting was installed so the power turns on/off according to the camera shooting time. The existing thermal infrared camera, which could only assess the relative temperature (high or low), was improved to extract the temperature value per pixel, and a comparison with the surface temperature sensor installed by the National Institute of Meteorological Sciences (NIMS) was performed to verify its accuracy. As a result of installing and operating the MFOS v2, which reflects these improvements, the accuracy and efficiency of automatic frost observation were demonstrated to be improved, and the usefulness of the data as input data for the frost prediction model was enhanced.

Correlation of Critical Air Temperature for Frost Delay on a Cold Plate (냉각면 평판에서 착상 지연을 위한 임계공기온도 상관식)

  • Kim, Jung-Soo;Kim, Yoo-Yil;Kim, Ook-Joong;Lee, Kwan-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.12 s.255
    • /
    • pp.1188-1195
    • /
    • 2006
  • This paper examines the critical air temperature at which frost formation does not occur on a cold plate in order to improve the efficiency of a heat pump. The critical air temperature on test points is obtained from numerical analysis and a correlation of the critical air temperature is derived as a function of frosting factors (air absolute humidity, air velocity, and cold plate temperature) by least square method. Experiments are carried out to verify the correlation proposed in this study, and the prediction obtained with the correlation agrees well with the experimental data. Based on the correlation, we propose the non-frosting regions according to frosting factors.

Leaching of Metal Sulfides and the Stability of Reaction Intermediates (황화광의 침출반응 및 중간생성물의 안정도)

  • Lee, Man Seung;Choi, Seung Hoon
    • Resources Recycling
    • /
    • v.27 no.3
    • /
    • pp.3-7
    • /
    • 2018
  • Development of extractive metallurgical processes for metal sulfides has become of importance owing to the depletion of oxide ores with rich metal contents. Most of the leaching reactions of metal sulfides is electrochemical reaction and can be classified as $H_2S$, S, and ${SO_4}^{2-}$ evolution type. The acidity of leaching solution and the presence and concentration of an oxidizing agent affect the formation of reaction intermediates containing sulfur. Frost diagram of sulfuroxoanion indicates that the oxoanions with higher oxidation number are more thermodynamically stable in the presence of oxidizing agents.