• Title/Summary/Keyword: Front-Door/Back-Door Coupling

Search Result 1, Processing Time 0.017 seconds

Electromagnetic Pulse Coupling into Naval Warship and Protective Measures (해군 함정에서의 EMP 영향 및 대책)

  • Yang, Jin-Ho;Nam, Sang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.4
    • /
    • pp.426-433
    • /
    • 2014
  • The high-altitude electromagnetic pulse(HEMP) generated by a high-altitude nuclear explosion. This paper presents the comparison of electric field penetration in Bell laboratories and IEC 61000-2-9 standard when HEMP source penetrates through Naval Warship conducted coupling path and radiated coupling path. Also we analyze the effects of two kinds of coupling and propose Protective measures. Simulation results confirm IEC 61000-2-9 standard is more strict than the Bell Laboratories standard except for a lower frequency band, so we proposed IEC 61000-2-9 standard as a Naval HEMP standard. Finally, we offer the protective measures such as the shielding coating, Honeycomb ventilation, TVS in order to meet the military criteria.