• 제목/요약/키워드: Fresh water generation

검색결과 44건 처리시간 0.029초

저압 증발기를 갖는 청수제조 장치에 관한 실험적 연구 (Experimental Study on Fresh Water Generation System with Low Pressure Evaporation)

  • 정한식;위보워;이경환;신용한;정효민
    • 동력기계공학회지
    • /
    • 제15권2호
    • /
    • pp.25-30
    • /
    • 2011
  • A fresh water generation system is designed for converting brackish water or seawater into fresh water. In this paper fresh water generation by distillation process that evaporates feed water and subsequently condenses vapor as evaporation product to get fresh water was studied and city water was employed as feed water. The system uses the ejector to create a vacuum, under which liquid can be evaporated at lower temperature than it at normal or atmospheric condition, hence less energy consumption. The effect of various operating conditions i.e. temperature of feed water and different orifice diameters were studied experimentally to investigate the characteristic of the system. It was found that these parameters have significant effect in the performance of fresh water generation system with low pressure evaporation.

자가 발전 시스템을 갖춘 고전압 전기장 수질개선 장치 개발 (Water Quality Improvement System Using High Voltage Electric Field with Self-Generation System)

  • 강래윤;강철웅
    • 동력기계공학회지
    • /
    • 제19권2호
    • /
    • pp.84-89
    • /
    • 2015
  • The occurrence of algae caused by eutrophication of fresh water is a pollution source to destroy the aquatic environment. When the high voltage electric field is applied in the water, When a high voltage is applied to the electric field in the water, the algae can be broken the balance of cell membranes, and is dead. In this paper, we develop a water quality improvement system for generating an electric field having a higher energy than the zeta potential when a high voltage is applied to 4,000V. To ensure the mobility of the water quality improvement system, we designed the PV generation system using the optimal size technique that is based on the model of power lack ratio. By evaluating the output characteristics of the water quality improvement system, power generation characteristics of the PV generation system, and battery charging characteristics, we can show that the proposed system can be applicable to the water quality improvement system inhibiting the growth rate of the algae in the fresh water.

태양에너지 해수담수화시스템 실증 (Demonstration study on Desalination System using Solar energy)

  • 김정배;주홍진;윤응상;주문창;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.27-33
    • /
    • 2007
  • In this research, to develop the practical application system of fresh water generation system with plate-type fresh water generator using low pressure evaporation method is the main object, and to do that, this study used the evacuated solar collector with operating range of about $50-85^{\circ}C$ as thermal energy source and solar photovoltaic as electric energy source. To achieve that object, this study set up the demo-plant, then estimated and analyzed the usefulness, the safety, and the reliability through pre-tests during short time ahead of the long-time operation. This study showed that the pumps, which are including sea water supply, ejector, hot water supply, and fresh water pumps, were operated one after another. And, the fresh water yield was closely related with the solar irradiance and lower supply temperature of hot water was revealed more reasonable for the solar energy desalination system. That is due to the insufficient area than the solar collector area being required that was estimated through the performance tests of the fresh water generator.

태양에너지 해수담수화 시스템 일일 운전 특성 (Daily Operating Characteristics of Desalination System with Solar Energy)

  • 곽희열;주홍진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.262-265
    • /
    • 2009
  • This study was carried out to evaluate the clear day operating performances for the decentralized desalination system with the solar thermal system and the photovoltaic power system. In a clear day, we used a solar thermal system as heat source of the single-stage fresh water generator with plate-type heat exchangers and a photovoltaic power system as electric source for hydraulic pumps. The demonstration system generation was designed and installed at Jeju-island in 2006. The system was comprised of the desalination unit with daily fresh water capacity designed as $2m^3$, a $120m^3$ evacuated tubular solar collector to supply the heat, a $6m^3$ heat storage tank, and a 5.2kW photovoltaic power generation to supply the electricity of hydraulic pumps for the heat medium fluids. In a clear day, solar irradiance daily averaged was measured $518W/m^3$, the daily fresh water yield showed that about 565 liter.

  • PDF

전산모사기법과 WRDF를 활용한 ONP 재활용 공정의 용수 및 오염부하 절감 방안에 관한 연구 (Methods for the Reduction of Consumption and Contamination of Water in a Newsprint Mill by Using Simulation Model and WRDF)

  • 이영애;류정용;성용주;김용환;송재광;송봉근;서영범
    • 펄프종이기술
    • /
    • 제36권2호
    • /
    • pp.54-59
    • /
    • 2004
  • The methods for the minimization of fresh water consumption, waste water generation and water contamination have been greatly investigated and developed for last ten years. Recently, the rising cost of waste water treatment and the more strict environmental regulation lead to the higher demand of more efficient and systematic methods for process water management. The water reuse technology, which not only reduce the process water needs but also minimize waste water generation within the process, could be one of most efficient way for current demand. In this study, the practical way for reduction of water pollution and optimal reuse or recycle of process water in a newsprint mill was investigated by using a simulation model. The result of computer simulation showed that the COD level of approach system could be reduced by 50% after the stock concentration at the 2nd disc filter was increased upto 30%. The application of WRDF(Wrinkled Rotary Drum Filter) to the newsprint mill was carried out with pilot scale. The process water treated by WRDF had enough cleanliness to substitute the forming fabric shower water with the PDF water, which could result in the 30% reduction in fresh water consumption.

1단 증발식 해수담수화 시스템의 계절별 성능 평가 (Evaluation of seasonal performance for single-stage desalination system with solar energy)

  • 곽희열;주홍진;주문창;김정배
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.221-226
    • /
    • 2008
  • This study was carry out evaluation of seasonal performance for the decentralized desalination system with the solar thermal system and the photovoltaic power system. First operating demonstration system was set up in Cheju in 2006. These system comprises the desalination unit with designed daily fresh water capacity of $2m^3$ and is supplied by a $120m^2$ evacuated tubular solar collector, a $6m^3$ heat storage tank, and a 5kW photovoltaic power generation supply the electricity for hydraulic pumps to move the working fluids. In a spring season day average $392W/m^2$, the daily fresh water showed to produce about 340liter. In a summer season day average $296W/m^2$, the daily fresh water showed to produce about 328liter. In a autumn season day average $349W/m^2$, the daily fresh water showed to produce about 277liter. In a winter season day average $342W/m^2$, the daily fresh water showed to produce about 271liter.

  • PDF

R123 열원 적용 증발식 담수 시스템 특성 연구 (Characteristics of Solar Desalination System Using Refrigerant-123 As a Heating Source)

  • 윤상국;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.33-38
    • /
    • 2010
  • The evaporative desalination system using solar thermal energy would be the efficient and attractive method to get fresh water from brine due to low carbon dioxide generation. In this research the solar desalination system as a heating source of refrigerant R123 in the evaporator was considered. The circulation of refrigerant in the evaporator can reduce the energy consumption of the system, because of using the latent heat of the refrigerant 123 instead of the sensible heat of present hot water. The system was comprised of the single-stage fresh water production unit on the capacity of 1ton/day with shell and tube type evaporator, heaters instead of solar collector to supply the proper heat to refrigerant, and refrigerant and brine circulation systems. Various operating flowrate and temperature ranges were varied in the experiments to get the optimum design data. The results showed that the optimum flow rate of brine feed rate to evaporator was 1.2Liter/min, and the yield of fresh water was increased as higher temperature of feed brine. It was confirmed that the circulation flowrate of heating source of refrigerant was decrease of one fifth of the present warm water system, and very efficient system for solar desalination.

담수 사용 NaBH4 가수 분해반응에 의한 수소발생 (Generation of Hydrogen from Hydrolysis Reaction of NaBH4 Using Fresh Water)

  • 오소형;유동근;김태호;김익균;박권필
    • Korean Chemical Engineering Research
    • /
    • 제59권4호
    • /
    • pp.503-507
    • /
    • 2021
  • 이동용 고분자전해질 연료전지(PEMFC)의 수소발생용으로써 NaBH4는 많은 장점을 갖고 있다. 야외에서 PEMFC가 이송형으로 사용될 때 증류수대신 담수를 이용해 NaBH4 가수분해하면 경제적이다. 그래서 본 연구에서는 NaBH4 가수분해 과정에 증류수대신 담수를 이용해 수소를 발생시켰다. 활성탄 담지 Co-P-B/C 촉매를 사용해 NaBH4 가수분해 특성에 대해 연구하였다. 담수는 NaBH4 가수분해과정에서 4수화물을 발생시키지 않았고, 증류수는 4수화물 부산물이 생성되어 가수분해과정에서 많은 물이 소모되어서 NaBH4 25% 이상 고농도에서 반응 종료시점에는 건조한 부산물과 미반응 NaBH4가 남았음을 확인하였다. 이 결과 담수를 사용했을 때 NaBH4 25% 이상 고농도에서 증류수보다 수소 수율과 수소발생속도가 더 높아 무인항공기등 이송형 연료전지에도 적용하기에 적합함을 보였다.

신재생에너지를 이용한 해수담수시스템 실증 연구 (Demonstration study of desalination system with renewable energy)

  • 주홍진;황인선;주문창;곽희열
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.197.1-197.1
    • /
    • 2010
  • This study was carried out to evaluate the operating performances of the evaporation desalination system with solar energy. This system was designed to use evacuated solar collector as the heat source, supplying the required heat energy and photovoltaic power as the electric source, supplying required power to pumps in the desalination system. The 5kW photovoltaic power generation system to make the electricity, the single-stage fresh water generator with plate heat exchanger, and remote control and monitoring system. Solar desalination system was designed and installed in Jeju-island, Korea in 2006, after about 4 years of operation, usability and stability of solar desalination system was guaranteed. The system comprises of the desalination unit which was designed to have daily fresh water capacity of $2m^3$, a $120m^2$ evacuated tubular solar collector to supply the heat, a $6m^3$ heat storage tank, and a 5.2kW photovoltaic power generation to supply the electricity to hydraulic pumps for the heat medium fluids. On a clear day, average daily solar irradiance in Jeju-island was measured to be $500W/m^2$ and the daily fresh water yield showed to be more than 500 liters under this condition. After around three years of a long term operation of the system from January 2007 to August 2009, average daily freshwater yield was analyzed to be around $330{\ell}$. The relationship equation between solar irradiance and freshwater yield was found to be y=1.1806x - 107.89.

  • PDF

LNG 선박 하이브리드 엔진 및 해수 담수화 복합 시스템 (LNG-Vessels Hybrid Engine Seawater Desalination Complex System)

  • 임재준;이동헌;변기식;김관형
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.663-664
    • /
    • 2016
  • 해수를 이용한 온도차 발전은 심층수와 표층수의 온도 차이를 이용한 암모니아(냉매)를 사용하여 폐쇄적인 액화와 기화를 반복하여 터빈을 돌리는 방식이다. 온도차 발전의 특성상 온도 차이가 클수록 에너지 발전 특성은 좋아진다. 이는 심층수 표층수의 온도차이가 커야 됨을 이야기 한다. 하지만 겨울이 되면 표층수와 심층수의 온도차이가 크지 않아 에너지 효율이 떨어지는 문제점이 있다. 그리고 해수 담수화기술은 지구의 97%를 차지하지만 우리가 먹을 수 없는 바닷물을 담수로 바꾸는 기술로, 해수 담수화기술로 생산된 담수는 선박내의 공업, 식수 등 각종 용수로 사용할 수 있다. 본 논문에서는 현재 문제가 되고 있는 계절에 따른 표층수의 온도 변화를 개선하기 위해 기존에 사용하고 있는 선박용 디젤엔진의 열에너지와 LNG의 냉열 에너지를 사용한 온도차 발전을 위해 LNG 운송 선박을 기준으로 LNG 운송 선박 하이브리드 엔진에 관한 연구와 냉열 에너지를 활용한 해수 냉동법으로 담수화하는 발전 및 담수화를 복합시킨 연구를 제시하고자 한다.

  • PDF