• Title/Summary/Keyword: Frequency-tension curve

Search Result 11, Processing Time 0.024 seconds

The Influence of Several Drugs Affecting $Ca^{2+}$ Influx on Frequency-tension Curve of Rat Left Atrium (쥐의 좌심방에서 세포막을 통한 $Ca^{2+}\;Flux$에 영향을 주는 약물이 자극빈도-장력 곡선에 미치는 영향)

  • Kim, Chan-Yun;Ahn, Sok-Kyun;Suh, Chang-Kook;Kang, Doo-Hee
    • The Korean Journal of Physiology
    • /
    • v.23 no.2
    • /
    • pp.329-337
    • /
    • 1989
  • Cardiac muscles show stimulation frequency-dependent tension changes i.e. Bowditch phenomenon and Woodworth phenomenon, the former is an increase of tension with the increase of stimulation frequency, whereas the latter is an increase of tension with a decrease of stimulation frequency. Bowditch phenomenon is seen in the range of frequency 1.0 cps and above, and Woodworth phenomenon below the frequency 1.0 cps in the most of mammalian cardiac atrium. To throw some light on the possible mechanism of both phenomena in rat atrium, influences of drugs affecting $Ca^{2+}$ influx through the plasma membrane $(verapamil,\;La^{3+},\;norepinephrine)$ and $Ca^{2+}$ release from sarcoplasmic reticulum (SR) on frequency-tension curve were studied. The results obtained are summarized as follows: 1) At low temperature $(27.5^{\circ}C)$, both Bowditch and Woodworth phenomenon were demonstrated. But Bowditch phenomenon disappeared at the temperature above $(32.5^{\circ}C)$. 2) At $(27.5^{\circ}C)$, in the presence of verapamil, a $Ca^{2+}$ channel blocker, a time course of change in the frequency-tension was studied. It was found that Bowditch phenomenon was affected before the Woodworth phenomenon, then the former was completely disappeared. At $(32.5^{\circ}C)$, where no Bow-ditch is seen in normal atrial muscle, Bowditch phenomenon was reappeared by an administration of norepinephrine suggesting again that slow inward current of such as $Ca^{2+}$ channel is closely related to Bowditch phenomenon. 3) At $27.5^{\circ}C$, in the presence of $La^{3+}$, although tensions were decreased at all stimulation frequencies, Bowditch and Woodworth phenomenon were still demonstrated. However in the presence of both $La^{3+}$ and verapamil, Bowditch phenomena was disappeared suggesting that $La^{3+}$ is less effective in blocking $Ca^{2+}$ channel than verapamil. 4) At $27.5^{\circ}C$, in the presence of ryanodine, an inhibitor of calcium release from SR, Woodworth phenomenon was disappeared, which was consistent with previous reports of others, suggesting that $Ca^{2+}$ release from SR is closely related to Woodworth phenomenon. From the above findings, it may be concluded that Bowditch phenomenon is dependent on the magnitude of $Ca^{2+}$ influx through slow channel and Woodworth phenomenon is dependent on the amount of $Ca^{2+}$ stored in SR.

  • PDF

Studies on the Acoustical Characteristics of Violin Bridges and SDM Simulation (바이올린 브릿지의 음향적 특성 및 SDM 시뮬레이션에 관한 연구)

  • 정우양
    • Journal of the Korea Furniture Society
    • /
    • v.12 no.1
    • /
    • pp.47-55
    • /
    • 2001
  • Violin bridge blank cut from maple wood with good quality has typical pattern of the radial direction in the side edge with minimal dispersion. This experimental study was designed and carried out to examine the effect of the physical and macroscopical characteristics on the compressive creep of violin bridge blank which had been imported from European manufacturer. This research arose from the idea that the maple solid wood with heterogeneous wood density and ray direction in the side edge would have uneven rheological property of violin bridge blank which is supposed to be pressed by the tension of strings. Experimentally, the compressive creep of bridge blank became smaller with the higher density of imported maple wood and showed clear density-dependence for the duration of load under the string tension of 5 kgf. Every bridge blank showed the behavior of primary creep stage(stress stabilization) having logarithmic regression creep curve with high correlation coefficient under the designed stress level. Even though the relationship between compressive creep and ray direction on the side edge of bridge was not so clear contrary to expectation, we could conclude that wood density and ray direction should be the quality decisive factors affecting the acoustical characteristics and performance of the bridge, the core member of violin-family bow instruments.

  • PDF

Effects of $Ca^{++}$, Verapamil and $La^{+++}$ on the Spontaneous Contraction and K-contracture in the Isolated Rat Uterine Smooth Muscle (칼슘, 베라파밀, 란타눔이 흰쥐 자궁근의 자발적 수축과 칼륨 경축에 미치는 효과)

  • Hwang, Sang-Ik
    • The Korean Journal of Physiology
    • /
    • v.18 no.1
    • /
    • pp.37-50
    • /
    • 1984
  • The effects of $Ca^{++}$ and its antagonists (verapamil and $La^{+++}$) upon the spontaneous contraction and the contracture induced by 60 mM K-Tyrode solution were studied in the isolated uterine muscle. Longitudinal muscle strips were prepared from the rat uteri at estrous stage. All experiments were performed in tris-buffered Tyrode solution which was aerated with 100% $O_2$ and kept at 35^{\circ}$. The results obtained were as follows: 1) In the uterine strips contracting spontaneously, both the amplitude of peak tension and the area of contraction curve increased dose-dependently in the range of $0.5${\sim}8$ mM $Ca^{++}$. The frequency of contraction increased as the concentration of $Ca^{++}$ increased up to 2 mM, but above this concentration the frequency decreased. In $Ca^{++}-free$ media, however, contraction did not develop. In the contracture induced by 60 mM K-Tyrode solution, the developed tension increased dose-dependently as the concentration of external $Ca^{++}$ increased to 8 mM. In the absence of external $Ca^{++}$ K-contracture appeared, but it was not sustained. 2) The spontaneous contraction of rat uterus was suppressed by verapamil in proportion to an increase of its concentration and totally abolished at the concentration of $3{\times}10^{-4}\;g/l$, but the spontaneous contraction re-appeared by addition of $Ca^{++}$. The amplitude of peak tension recovered completely but the recovery of frequency was incomplete. K-contracture decreased in a dose-dependent manner after the treatment with verapamil and totally disappeared at its concentration of $3{\times}10^{-4}\;g/l$. Even in this case contracture developed again by extra $Ca^{++}$. 3) The spontaneous contractile activity was inhibited by $La^{+++}$. At the concentration of $10^{-4}$M $La^{+++}$, fibrillation appeared. In the strip inhibited by $10^{-5}M\;La^{+++}$, contractility recovered completely by extra $Ca^{++}$ while in the $10^{-4}M\;La^{+++}$ treated preparation, the rhythmic spontaneous contraction did not develop even at the concentration of 16 mM $Ca^{++}$. After the initial transient depression of contracture tension by $10^{-3}M$ of $La^{+++}$, the strip stowed considerably large size of contracture, hardly influenced by external $Ca^{++}$ or verapamil. The results obtained in this experiment suggest that in the rat uterine muscle there would be some competitive actions between $Ca^{++}$ and its antagonists. It is speculated that $Ca^{++}$ plays an important role in the conduction of excitation, and $La^{+++}$ influences upon cellular $Ca^{++}$ mobilization and re-uptake process as well as transmembrane $Ca^{++}$ transport in a K-depolarized state.

  • PDF

Frequency domain analysis of Froude-Krylov and diffraction forces on TLP

  • Malayjerdi, Ebrahim;Tabeshpour, Mohammad Reza
    • Ocean Systems Engineering
    • /
    • v.6 no.3
    • /
    • pp.233-244
    • /
    • 2016
  • Tension Leg Platform (TLP) is a floating structure that consists of four columns with large diameter. The diffraction theory is used to calculate the wave force of floating structures with large dimensions (TLP). In this study, the diffraction and Froude-Krylov wave forces of TLP for surge, sway and heave motions and wave force moment for roll, pitch degrees of freedom in different wave periods and three wave approach angles have been investigated. From the numerical results, it can be concluded that the wave force for different wave approach angle is different. There are some humps and hollows in the curve of wave forces and moment in different wave periods (different wavelengths). When wave incidents with angle 0 degree, the moment of diffraction force for pitch in high wave periods (low frequencies) is dominant. The diffraction force for heave in low wave periods (high wave frequencies) is dominant. The phase difference between Froude-Krylov and diffraction forces is important to obtain total wave force.

Electrophysiological and Mechanical Characteristics in Human Ileal Motility: Recordings of Slow Waves Conductions and Contractions, In vitro

  • Ryoo, Seung-Bum;Oh, Heung-Kwon;Moon, Sang Hui;Choe, Eun Kyung;Yu, Sung A;Park, Sung-Hye;Park, Kyu Joo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.19 no.6
    • /
    • pp.533-542
    • /
    • 2015
  • Little human tissue data are available for slow waves and migrating motor complexes, which are the main components of small bowel motility. We investigated the electrophysiological and mechanical characteristics of human ileal motility, in vitro. Ileum was obtained from patients undergoing bowel resection. Electrophysiological microelectrode recordings for membrane potential changes and mechanical tension recordings for contraction from smooth muscle strips and ileal segments were performed. Drugs affecting the enteric nervous system were applied to measure the changes in activity. Slow waves were detected with a frequency of 9~10/min. There were no cross-sectional differences in resting membrane potential (RMP), amplitude or frequency between outer and inner circular muscle (CM), suggesting that electrical activities could be effectively transmitted from outer to inner CM. The presence of the interstitial cell of Cajal (ICC) at the linia septa was verified by immunohistochemistry. Contractions of strips and segments occurred at a frequency of 3~4/min and 1~2/min, respectively. The frequency, amplitude and area under the curve were similar between CM and LM. In segments, contractions of CM were associated with LM, but propagation varied with antegrade and retrograde directions. Atropine, $N^W$-oxide-L-arginine, and sodium nitroprusside exhibited different effects on RMP and contractions. There were no cross-sectional differences with regard to the characteristics of slow waves in CM. The frequency of contractions in smooth muscle strips and ileal segments was lower than slow waves. The directions of propagation were diverse, indicating both mixing and transport functions of the ileum.

Fatigue crack effect on magnetic flux leakage for A283 grade C steel

  • Ahmad, M.I.M.;Arifin, A.;Abdullah, S.;Jusoh, W.Z.W.;Singh, S.S.K.
    • Steel and Composite Structures
    • /
    • v.19 no.6
    • /
    • pp.1549-1560
    • /
    • 2015
  • This paper presents the characterization of fatigue crack in the A283 Grade C steel using the MMM method by identifying the effects of magnetic flux leakage towards the crack growth rate, da/dN, and crack length. The previous and current research on the relation between MMM parameters and fatigue crack effect is still unclear and requires specific analysis to validate that. This method is considered to be a passive magnetic method among other Non-Destructive Testing (NDT) methods. The tension-tension fatigue test was conducted with a testing frequency of 10 Hz with 4 kN loaded, meanwhile the MMM response signals were captured using a MMM instrument. A correlation between the crack growth rate and magnetic flux leakage produces a sigmoid shape curve with a constant values which present the gradient, m value is in the ranges of 1.4357 to 4.0506, and the y-intercept, log C in the ranges of $4{\times}10^{-7}$ to 0.0303. Moreover, a linear relation was obtained between the crack length and magnetic flux leakage which present the R-Squared values is at 0.830 to 0.978. Therefore, MMM method has their own capability to investigate and characterize the fatigue crack effects as a main source of fracture mechanism for ferrous-based materials.

Modified sigmoid based model and experimental analysis of shape memory alloy spring as variable stiffness actuator

  • Sul, Bhagoji B.;Dhanalakshmi, K.
    • Smart Structures and Systems
    • /
    • v.24 no.3
    • /
    • pp.361-377
    • /
    • 2019
  • The stiffness of shape memory alloy (SMA) spring while in actuation is represented by an empirical model that is derived from the logistic differential equation. This model correlates the stiffness to the alloy temperature and the functionality of SMA spring as active variable stiffness actuator (VSA) is analyzed based on factors that are the input conditions (activation current, duty cycle and excitation frequency) and operating conditions (pre-stress and mechanical connection). The model parameters are estimated by adopting the nonlinear least square method, henceforth, the model is validated experimentally. The average correlation factor of 0.95 between the model response and experimental results validates the proposed model. In furtherance, the justification is augmented from the comparison with existing stiffness models (logistic curve model and polynomial model). The important distinction from several observations regarding the comparison of the model prediction with the experimental states that it is more superior, flexible and adaptable than the existing. The nature of stiffness variation in the SMA spring is assessed also from the Dynamic Mechanical Thermal Analysis (DMTA), which as well proves the proposal. This model advances the ability to use SMA integrated mechanism for enhanced variable stiffness actuation. The investigation proves that the stiffness of SMA spring may be altered under controlled conditions.

Fatigue Characteristics of Engine Rubber Mount for Automotive (자동차용 엔진 마운트의 피로거동에 관한 연구)

  • Suh, Chang-Min;Oh, Sang-Yeob;Park, Dae-Kyu;Jang, Ju-Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.5
    • /
    • pp.45-53
    • /
    • 2009
  • In this study, Finite Element Analysis (FEA) was used to decide three kinds of material property of vibration proof rubber with the unique characteristic of non-linear and large deformation. As well, three types of hardness (Hs 50, 55, 60) were compared with the result of fatigue tests, fatigue life was able to be predicted. The request for fatigue life becomes strict more and more as increasing stress under conditions like a compaction, high load and high temperature for parts because it is main characteristics of rubber mount for automotive. Regarding to the fatigue life under dynamic deformation condition, it can be predicted as checking forced deformation extends and its frequency and its strain-life curve. As for material property tests of uniaxial tension test, uniaxial compression test, pure shear test, Ogden model was used for FEA by observing relations between stress and strain's rate as curve fitting. As a result of FEA, fatigue life for rubber mount was predicted and accorded well with the experimental data of fatigue test with hourglass specimens. In addition, its property of the predictable fatigue life method suggested in this study was accorded well with the experimental data by comparing the predicted fatigue life of FEA with the result of fatigue test for rubber component of engine rubber mount.

Annealing Effect in the Cold-Plastic Deformation of Amorphous PET Material (무정형 PET 재료의 플라스틱 냉간 변형에서의 열처리 효과)

  • Lee, Jong-Young;Park, Seong-Soo
    • Polymer(Korea)
    • /
    • v.25 no.1
    • /
    • pp.56-62
    • /
    • 2001
  • When polyethylene terephthalate(PET) film specimen were stepwise elongated under tension with various speeds of about 0.5~500 mm/min, the necking area, consisted of transparent and opaque bands, was formed during plastic deformation. Stress oscillation was apparently obtained in the stress-strain curve of above specimen. However, stress oscillation was not obtained in the stress-strain curve of annealing specimen. Microstructure was examined dynamically using an optical microscopy and thermal analysis was carried out in a differential scanning calorimeter at a heating rate of 10${\circ}$/min. Also, orientation and crystallization were examined using monochromatic-pinhole technique and elastic modulus was measured by a dynamic mechanical analyzer in the temperature range of -150~70 ${\circ}$ with the frequency of 1 Hz. Transparent PET products were fabricated by use of the PET pellets annealed at 83${\circ}$ for 30 min in an electric furnace.

  • PDF

Model on the Capillary Action-Induced Dynamics of Contact Lens (모세관 작용에 의한 콘택트 렌즈의 운동 모델)

  • Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.85-97
    • /
    • 2001
  • A mathematical model was proposed to analyze the damped motion of contact lens which is initially displaced from the equilibrium position. The model incorporates the differential equations and their numerical solution program, based on the formulations of restoring force arising from the capillary action in the tear-film layer between the lens and cornea. The model predicts the capillary action induced surface tension, time dependence of displacement of lens when it is released from the equilibrium position. It seems that the motion of lens is similar to the typical over-damped oscillation caused by the large viscous friction in the liquid layer between the cornea and lens. The effect of variables such as base curves, lens diameters and thickness of tear film layer were illustrated by the computer simulation of the derived program. The time required for the lens to return to the original position increases as the liquid layer thickness increases and it decreases as the diameter of lens increases. With the certain value of base curve the time interval is found to be minimum. The free vibrations of lenses were also simulated varying the parameters such as base curve, diameter, layer thickness. The resonant frequencies are inversely proportional to the liquid layer thickness and it increases as the lens diameter increases. The resonant frequency of lens has a maximum when the diameter is of certain value. If the external impulse or force of the same frequency as the natural frequency of contact lens acted on the cornea in vivo it may cause an excessive movement and thus it might cause the distortion 10 the lens or be pulled off the eye.

  • PDF