• Title/Summary/Keyword: Frequency change

Search Result 4,358, Processing Time 0.031 seconds

Study on Process Monitoring of Elliptical Vibration Cutting by Utilizing Internal Data in Ultrasonic Elliptical Vibration Device

  • Jung, Hongjin;Hayasaka, Takehiro;Shamoto, Eiji
    • International Journal of Precision Engineering and Manufacturing-Green Technology
    • /
    • v.5 no.5
    • /
    • pp.571-581
    • /
    • 2018
  • In the present study, monitoring of elliptical vibration cutting process by utilizing internal data in the ultrasonic elliptical vibration device without external sensors such as a dynamometer and displacement sensor is investigated. The internal data utilized here is the change of excitation frequency, i.e. resonant frequency of the device, voltages applied to the piezoelectric actuators composing the device, and electric currents flowing through the actuators. These internal data change automatically in the elliptical vibration control system in order to keep a constant elliptical vibration against the change of the cutting process. Correlativity between the process and the internal data is described by using a vibration model of ultrasonic elliptical vibration cutting and verified by several experiments, i.e. planing and mirror surface finishing of hardened die steel carried out with single crystalline diamond tools. As a result, it is proved that it is possible to estimate the elements of elliptical vibration cutting process, e.g. tool wear and machining load, which are important for stable cutting in such precision machining.

Analysis of the Textbook Contents Related to the Action Competence on Climate Change(ACoCC) of the 2015 Revised Middle School 「Technology & Home Economics」 Curriculum and the Suggestions for Improvements of Activity Tasks (2015 개정 교육과정 중학교 「기술·가정」 교과서에 나타난 기후변화 대응 실천역량 분석 및 활동과제 개선 방안)

  • Jo, Yoon-Jeong;Han, Ju
    • Journal of Korean Home Economics Education Association
    • /
    • v.34 no.2
    • /
    • pp.95-113
    • /
    • 2022
  • The purpose of this study is to analyze the 'Action Competence on Climate Change(ACoCC)' shown in 12 types of middle school 「Technology & Home Economics」 textbooks written according to the 2015 revised curriculum, and to suggest ways to improve the activity tasks. According to the results of the analysis, first, the 'knowledge on climate change' was the most frequently mentioned, and 'climate change communication' was the least frequently mentioned in the textbook among ACoCC. Second, all 12 textbooks dealt with 'knowledge about climate change' most frequently, yet the frequency of mentioning other competencies differed by publisher. In relation to the core concepts, the ACoCCs were most often discussed in the 'Management,' yet never discussed in the 'Life Design' at all. In relation to the academic sub-fields of home economics, the 'clothing life' showed the highest frequency of mentioning ACoCCs, while 'family life' the lowest frequency. Based on the results of the above analysis, it was suggested that the capacity to respond to climate change should be dealt with in the overall fields of home economics education. This study has implications as a basic study related to climate change in home economics education, and it is expected that various research and educational programs in home economics education that focus on climate change mitigation are implemented in the future.

The Influence of Position Change on Autonomic Nervous System Function (자세변화가 자율신경계에 미치는 영향)

  • Kim, In-Bae;Kim, Eun-Kyung;Kang, Jong-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.1
    • /
    • pp.63-68
    • /
    • 2014
  • PURPOSE: The purpose of this study was to examine the position changes with tilt table on autonomic nervous system using heart rate variability analysis. METHODS: Fourty healthy adult males volunteered in this study. The low frequency, high frequency and low frequency/high frequency ratio and mean heart rate, standard deviation of all normal R-R intervals, root mean square of successive differences, heart rate variability index were measured at the tilt table angle of $0^{\circ}$, $45^{\circ}$ and $90^{\circ}$ with pulsoximeter. Data were analyzed one-way ANOVA and LSD post hoc test. RESULTS: The mean heart rate, low frequency and low frequency/high frequency ratio increased significantly at higher angle of tilt table(p<.05). The root mean square of successive differences, heart rate variability index decreased significantly at lower angle of tilt table(p<.05). The standard deviation of all normal R-R intervals, high frequency decreased at higher angle of tilt table did not show significant difference. CONCLUSION: The symphathetic activity increased significantly at higher angle of tilt table. The parasymphathetic activity decreased at higher angle of tilt table, but the difference were not significant. The autonomic adaptation, balance and heart rate variability decreased significantly at higher angle of tilt table. Based on these results, in the treatment of patients with a change in posture precedence should be carefully treated. Further studies are necessary to determine the most safety and effective methods.

A Case Study on the Reduction of Noise and Vibration at the Backpass Heat Surface in the Power Plant Boiler (발전용 보일러 후부 전열면 소음진동 저감에 관한 연구)

  • Lee, Gyong-Soon;Lee, Tae-Gu;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.4 no.3
    • /
    • pp.54-59
    • /
    • 2008
  • The resonance of boiler is caused by exciting force in the gas path and it generates the vibration by the harmony of boiler's dimensional factor. According to trending toward the boiler of increasing capacity and a bigger size, it has a problem of the vibration at back-pass heating surfaces. We can predict such vibrations as comparison between vortex frequency and gas column's natural frequency. We can't rely on the method for the past decades because of changing parameters, such as an allowable error, gas temperature, gas velocity, Strouhal number. We can reduce the vibration to use the seasoning effect and change the operating condition in coal fired boiler but it's not essential solution. When the vibration occurred in the model boiler, we must measures the acoustic pressure and frequency of places for considering the means. So far, we confirmed the problem from field measures and theoretical analysis about the acoustic vibration of boiler. We installed anti-acoustic baffle in a existing boiler to change the acoustic natural frequency at the cavity, which results in reducing the acoustic vibration. The first, we prove that the acoustic resonance is caused by harmonizing vortex shedding frequency of tube heat surface with acoustic natural frequency of cavity in the range of 650~750 MW loads. The second, the acoustic resonance at the back-pass heating surface has the third order of acoustic natural frequency at the second economizer. We install five anti-acoustic baffles at the second economizer to reducing the resonance. We confirm considerably reducing the acoustic vibration of boiler during the commercial boiler.

  • PDF

The Effect of the Physical Therapy Treatment Room Environment Using Microwave Diathermy on the Autonomic Nervous System of Human Body (극초단파치료기를 사용하는 물리치료실의 환경이 물리치료사의 인체자율신경계에 미치는 영향)

  • Shin, Han-Ki;Lee, Tae-Kyu;Jun, Je-Yoon;Kim, Ju-Seung;Kang, Jong-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.1
    • /
    • pp.37-43
    • /
    • 2015
  • PURPOSE: The purpose of this study is to investigate the effect of the physical therapy treatment room environment using microwave diathermy on the autonomic nervous system of human body. METHODS: Participants were 24 healthy adults. Standard deviation of all normal R-R intervals(SDNN), root mean square of successive differences(RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were compared in microwave irradiation and non-irradiation group. Data were analyzed in Wilcoxon's signed-ranks test and Mann-Whitney U test. RESULTS: Standard deviation of all normal R-R intervals (SDNN), root mean square of successive differences (RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were not significantly different in microwave irradiation group. Standard deviation of all normal R-R intervals(SDNN), root mean square of successive differences (RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were not significantly different in microwave non-irradiation group. Standard deviation of all normal R-R intervals(SDNN), root mean square of successive differences (RMSSD), low frequency(LF), high frequency(HF), LF/HF ratio were not significantly different between two groups. CONCLUSION: There was no significant change in the sympathetic nervous system and parasympathetic nervous system regardless of the presence of microwave irradiation. There was no significant change in the autonomic nervous system adaptability regardless of the presence of microwave irradiation.According to this study, microwave diathermy does not have significant effect on the autonomic nervous system.Future study is necessary to investigate the long term effect of the physical therapy treatment room environment using microwave diathermy on the autonomic nervous system of the human body.

Least Mean Square Estimator for Motor Frequency Measurement Based on Linear Hall Sensor (선형 홀센서 기반의 모터 회전속도 측정을 위한 평균 최소 자승 추정기)

  • Choi, Ga-Hyoung;Ra, Won-Sang;Kwak, Ki-Seok;Yoon, Tae-Sung;Park, Jin-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.866-874
    • /
    • 2008
  • Motor frequency can be measured by a hall sensor. Among the many hall sensors, a linear type hall sensor is good at high accuracy frequency measuring problem. However, in general, this linear type hall sensor has DC offset which can vary along sensor's operating voltage change. Therefore, In motor frequency measurement problem using the linear hall sensor, it needs an estimator that can estimate frequency and DC offset simultaneously. In this paper, we propose the least mean square estimator to estimate motor frequency. To verify its performance, we compare the LMS estimator with a commercial analog tachometer. Experimental results shows the proposed LMS estimator works well in varying frequency and stationary DC offset.

Estimation Technique of Frequency using FIR Filter in the Power System (FIR 필터를 이용한 전력계통의 주파수 추정기법)

  • 남시복;박철원;신명철
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.50 no.3
    • /
    • pp.101-108
    • /
    • 2001
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the Power system energy balance. This paper describes a digital signal processing technique for measuring the operating frequency of a power system. The fundamental frequency component of 3-phase signal is first extracted by using an algorithm based on FIR filter. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154KV double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

New Adaptive Linear Combination Structure for Tracking/Estimating Phasor and Frequency of Power System

  • Wattanasakpubal, Choowong;Bunyagul, Teratum
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.28-35
    • /
    • 2010
  • This paper presents new Adaptive Linear Combination Structure (ADALINE) for tracking/estimating voltage-current phasor and frequency of power system. To estimate the phasors and frequency from sampled data, the algorithm assumes that orthogonal coefficients and speed of angular frequency of power system are unknown parameters. With adequate sampled data, the estimation problem can be considered as a linear weighted least squares (LMS) problem. In addition to determining the phasors (orthogonal coefficients), the procedure estimates the power system frequency. The main algorithm is verified through a computer simulation and data from field. The proposed algorithm is tested with transient and dynamic behaviors during power swing, a step change of frequency upon islanding of small generators and disconnection of load. The algorithm shows a very high accuracy, robustness, fast response time and adaptive performance over a wide range of frequency, from 10 to 2000 Hz.

Developmental Competence of Intrafollicular Oocytes Derived from Preantral Follicle Culture with Different Protocols after Parthenogenetic Activation

  • Choi, Jung Kyu;Lee, Jae Hee;Lee, Seung Tae;Choi, Mun Hwan;Gong, Seung Pyo;Lee, Eun Ju;Lim, Jeong Mook
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.8
    • /
    • pp.1190-1195
    • /
    • 2007
  • This study was conducted to improve efficiency of a follicle culture system without reducing developmental competence of intrafollicular oocytes. Preantral follicles (100 to $125{\mu}m$ in diameter) of F1 hybrid (B6CBAF1) mice were cultured singly for 216 h in modified ${\alpha}$-MEM-glutamax medium, to which 2.5 IU/ml hCG and epidermal growth factor was added 16 h prior to the end of culture. Medium change was either performed three times (54 h interval), twice (72 h interval), once (108 h interval), or not at all (216 h interval). Maturation (progression to the metaphase II stage) of intrafollicular oocytes was detected from 4 days after culture in the three-times change treatment, while all treatments yielded mature oocytes from day 5 of culture. Compared with the three-times change, decreasing the change frequency to once did not reduce the capacity to begin maturation (germinal vesicle breakdown of 82 to 86%), to mature (78 to 79%) and to develop into blastocysts after parthenogenetic activation (29 to 32%). Morphological parameters were similar among these treatments. Except for the no medium change treatment, similar colony-forming activity of inner cell mass cells after culturing of blastocysts in leukemia inhibitory factor-containing medium was detected, while the morphology of the colony-forming cells deteriorated in the change-once treatment compared with the change twice or three-times. In conclusion, the efficiency of the preantral follicle culture system could be improved by reducing frequency of medium change up to a 72 h interval (three times in total 216 h culture) without decreasing developmental competence of oocytes.