• 제목/요약/키워드: Frequency and power stability

검색결과 468건 처리시간 0.029초

풍력발전단지의 효율적 운영을 위한 퍼지로직 기반 주파수 제어기 설계 (A Design for a Fuzzy Logic based Frequency Controller for Efficient wind Farm Operation)

  • 김세윤;김성호
    • 제어로봇시스템학회논문지
    • /
    • 제20권2호
    • /
    • pp.186-192
    • /
    • 2014
  • Recently wind energy penetration into power systems has increased. Wind power, as a renewable energy source, plays a different role in the power system compared to conventional power generation units. As long as only single and small wind power units are installed in the power system, wind power does not influence power system operation and can easily be integrated. However, when wind power penetration reaches a significantly high level and conventional power production units are substituted, the impact of wind power on the power system becomes noticeable and must be handled. The connection of large wind turbines and wind farms to the grid has a large impact on grid stability. The electrical power system becomes more vulnerable to and dependent on wind energy production, and therefore there is an increased concern about the large wind turbines impact on grid stability. In this work, a new type of fuzzy logic controller for the frequency control of wind farms is proposed and its performance is verified using SimWindFarm toolbox which was developed as part of the Aeolus FP7 project.

전력계통 안정도를 고려한 계통보호 대책 연구 (A Study of System Protection with emphasis on Power System Stability)

  • 장병태;이소영;김경호;안정식;양정재;강계희;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.99-101
    • /
    • 2002
  • This paper is to introduce the R&D project called "System Protection with emphasis on Power System Stability". The principal objective of this project is protection aids to system stability. The objects of this project arc as follows. First, drawbacks of classical under frequency load shedding and implementation issues of the rate-of-change of frequency will be described. Secondly, the project discusses the possibilities of voltage instability in power system and how this risk will affect protective relays in real system. Lastly, special protection system is designed to preserve system stability for KEPCO.

  • PDF

주파수 조정을 위한 4MW 전력 저장 시스템 연구 (The Study on 4MW Energy Storage System for Frequency Regulation)

  • 고광수;이충우;강병관;오승훈;이윤재;최은식;류강열;김희중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.125-126
    • /
    • 2013
  • ESS(Energy Storage System) for Improve the quality of the power grid, supply reliability, system stability and the efficient operation method of power is drawing attention. According to changes in the load of the power system frequency will be adjustable in real time in response to changes in the frequency of the grid, so thermal power output is mainly controlled in order to keep the grid frequency stable. ESS for adjusting the frequency of the grid when the frequency rises to grid and charge the energy storage device. If the frequency drops to discharge the battery power to the grid and the future is expected to replace the thermal power plant. This paper describes 4MW ESS for the frequency regulation and find out about the characteristics through the PSCAD/EMTDC.

  • PDF

MOBA based design of FOPID-SSSC for load frequency control of interconnected multi-area power systems

  • Falehi, Ali Darvish
    • Smart Structures and Systems
    • /
    • 제22권1호
    • /
    • pp.81-94
    • /
    • 2018
  • Automatic Generation Control (AGC) has functionally controlled the interchange power flow in order to suppress the dynamic oscillations of frequency and tie-line power deviations as a perturbation occurs in the interconnected multi-area power system. Furthermore, Flexible AC Transmission Systems (FACTS) can effectively assist AGC to more enhance the dynamic stability of power system. So, Static Synchronous Series Compensator (SSSC), one of the well-known FACTS devices, is here applied to accurately control and regulate the load frequency of multi-area multi-source interconnected power system. The research and efforts made in this regard have caused to introduce the Fractional Order Proportional Integral Derivative (FOPID) based SSSC, to alleviate both the most significant issues in multi-area interconnected power systems i.e., frequency and tie-line power deviations. Due to multi-objective nature of aforementioned problem, suppression of the frequency and tie-line power deviations is formularized in the form of a multi-object problem. Considering the high performance of Multi Objective Bees Algorithm (MOBA) in solution of the non-linear objectives, it has been utilized to appropriately unravel the optimization problem. To verify and validate the dynamic performance of self-defined FOPID-SSSC, it has been thoroughly evaluated in three different multi-area interconnected power systems. Meanwhile, the dynamic performance of FOPID-SSSC has been accurately compared with a conventional controller based SSSC while the power systems are affected by different Step Load Perturbations (SLPs). Eventually, the simulation results of all three power systems have transparently demonstrated the dynamic performance of FOPID-SSSC to significantly suppress the frequency and tie-line power deviations as compared to conventional controller based SSSC.

교류-직류 연계계통에 있어서 직류제어방식의 비교연구 (A study on comparative analysis of direct current control in A.C.-D.C. interconnected power system)

  • 정형환;왕용필;안병철;이광우
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.474-483
    • /
    • 1996
  • In this paper, as a part of the method improving stability, the load-flow calculation in D.C. power system and the models for stability analysis are studied with A.C-D.C. interconnected power systems transmission performed. Moreover, the theory is established in relation to each control method of D.C. power systems. Then the stability of A.C-D.C.interconnected power systems is compared and considered by the way of dividing the operating control method of the rectifier inverter converter into ACR-AVR, APR-A.gamma.R, A.alpha.R-ACR. The dynamics characteristic of terminal voltage, frequency, active-reactive power and rotor angle of the generator with disturbances and load fluctuations is considered. In addition, the characteristic of direct voltage, direct current, power and control systems. From this the comparative analysis of the direct current control method, the possibility of the stability analysis of A.C.-D.C. interconnected power system is considered. (author). refs., figs., tabs.

  • PDF

전 디지털제어 전원장치 (Fully Digital Controlled Power Supply for PLS)

  • 하기만;김윤식;이성근
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.1011-1015
    • /
    • 2005
  • Fully digital controlled 20-bit magnet power supplies have been developed and successfully tested for closed orbit correction of PLS(Pohang Light Source). The new digital power supply has used fiber optics for 25kHz switching of IGBT drivers, and implemented DSP, ADC, Interlock, DCCT cards in a compact 3U-sized 19" chassis. Input/Output low-pass filters suppress harmonics of 60Hz line frequency and switching frequency noise effectively. Overall performance of the power supplies have been demonstrated as +/- 2ppm short-term stability(<1 min), and +/- 10ppm long-term stability(<36 hours). All the existing 12-bit 70 power supplies for vertical correction magnets will be replaced with new digital power supplies during 2005 summer shutdown period. In this paper, we will describe the hardware structure and control method of the digital power supply and the experimental results will be shown.

  • PDF

산업용 플랜트 및 상업용 시설물 전력계통의 안정도에 대한 연구 (A STABILITY STUDY FOR INDUSTRIAL PLANTS AND COMMERCIAL FACILITIES)

  • 김기택;윤덕로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 전기설비
    • /
    • pp.19-21
    • /
    • 2005
  • The purpose of power system design is, in a word, to provide a good quality of electric power. The design of reliable industrial and commercial power distribution system is important because of the high costs associated with power outage. Three major factors for realization of the purpose are: (1) To hold system frequency at or very close to a specified nominal value(e.g. 60Hz) by control of frequency-effective power. (2) To maintain the correct value of interchange power between power and local generators. (3) To hold system voltage at or very close to a specified nominal value by control of voltage-reactive power. Within the past decade, numbers of industrial and commercial facilities installed with local generation, large motors or both, are increasing. This means that system stability is of concern to a growing number of industrial plant electrical engineers and consultants.

  • PDF

주파수 안정도 개선을 위한 디지털 조속기 제어기 개발 (Design of Digital Governor Controller for Frequency Stability Improvement)

  • 이상훈;최상규;이화춘;송성근
    • 조명전기설비학회논문지
    • /
    • 제26권9호
    • /
    • pp.64-72
    • /
    • 2012
  • The interest in wind power generation area such as developing and operating wind-diesel pilot complex in remote and island regions that have difficulty in having power plant and connecting to power system is growing rapidly in the world. We have installed and researched the hybrid system in Sekgok Pilot Complex to meet the new generation system. From the monitored data of the system, the performance of each diesel power plant is outstanding. However, step out problem was detected with respect to load sharing and synchronization with decentralized power supply. An advanced controller design having better response time and stability is needed to solve such problem. In this paper, we proposed the algorithm, through digital controller of Governor, which is applied to hybrid system. As a result, we obtained the stable frequency value in variable loading conditions. Also, we proved the advanced response time and stability through the simulation and experiment by applying additional current signal to the control algorithm.

HVDC 연계 시스템의 전력계통 안정화 장치와 전력변환기 적정 파라미터 선정에 관한 연구 (A Study on the Optimal Parameter Selection of a Power System Stabilizer and Power Converters for HVDC Linked System)

  • 조의상;김경철;최홍규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.65-72
    • /
    • 2001
  • Power system stabilizer act efficiently to damp the electromechanical oscillations in interconnected power systems. This paper presents an algorithm for the optimal parameter selection of a power system stabilizer in two-area power systems with a series HVDC link. This method is one of the classical techniques by allocating properly pole-zero positions to fit as closely as desired the ideal phase lead between the voltage reference and the generator electrical power and by changing the gain to produce a necessary damping torque over the matched frequency range. Control of HVDC converter and inverter are used a constant current loop. Proper parameters of PI controllers are obtain based on the Root-locus technique in other to have sufficient speed and stability margin to cope with charging reference values and disturbance. The small signal stability arid transient stability studies using the PSS parameters obtained from this method show that a natural oscillation frequency of the studycase system is adequately damped. Also the simulation results using the HVDC converter and inverter parameters obtained from this proposed method show proper current control characteristics. The simulation used in the paper was performed by the Power System Toolbox software program based on MATLAB.

  • PDF

전자계통 현상 시각화 MMI 개발에 관한 연구 (A Study of the development of a visualization MMI for Power System Phenomenons)

  • 이욱화;박인권;김욱;이진;최종웅;윤용범;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.175-177
    • /
    • 1999
  • This paper presents a prototype of visualization MMI of the Power System Phenomenon, specially synchronous machine dynamics and frequency deviations of power system for KEPCO's Enhanced Power System Simulator(KEPS)[1]. And some visualization designs of the Power System Phenomenons such as voltage stability, transient stability, SSR, Line overflow, and voltage deviations are presented. The prototype MMI has included the animations & 3D graphics presentations for synchronous machine rotor deviations and frequency deviations. So, a user can intuitively acquire the basic concepts of the power system oscillations. Finally, it will be scheduled to development of the various visualization MMI of the power system phenomenons for development and installation of KEPS.

  • PDF