• Title/Summary/Keyword: Frequency analyzer

Search Result 617, Processing Time 0.028 seconds

Acoustic responses of natural fibre reinforced nanocomposite structure using multiphysics approach and experimental validation

  • Satankar, Rajesh Kumar;Sharma, Nitin;Ramteke, Prashik Malhari;Panda, Subtra Kumar;Mahapatra, Siba Shankar
    • Advances in nano research
    • /
    • v.9 no.4
    • /
    • pp.263-276
    • /
    • 2020
  • In this article, the acoustic responses of free vibrated natural fibre-reinforced polymer nanocomposite structure have been investigated first time with the help of commercial package (ANSYS) using the multiphysical modelling approach. The sound relevant data of the polymeric structure is obtained by varying weight fractions of the natural nanofibre within the composite. Firstly, the structural frequencies are obtained through a simulation model prepared in ANSYS and solved through the static structural analysis module. Further, the corresponding sound data within a certain range of frequencies are evaluated by modelling the medium through the boundary element steps with adequate coupling between structure and fluid via LMS Virtual Lab. The simulation model validity has been established by comparing the frequency and sound responses with published results. In addition, sets of experimentation are carried out for the eigenvalue and the sound pressure level for different weight fractions of natural fibre and compared with own simulation data. The experimental frequencies are obtained using own impact type vibration analyzer and recorded through LABVIEW support software. Similarly, the noise data due to the harmonically excited vibrating plate are recorded through the available Array microphone (40 PH and serial no: 190569). The numerical results and subsequent experimental comparison are indicating the comprehensiveness of the presently derived simulation model. Finally, the effects of structural design parameters (thickness ratio, aspect ratio and boundary conditions) on the acoustic behaviour of the natural-fibre reinforced nanocomposite are computed using the present multiphysical model and highlighted the inferences.

Analysis of Phonatory Aerodynamic & E.G.G. during Passaggio of the Trained Male Singers (남성성악가의 Vocal Register Transition(Passaggio)시 공기역학적 변화와 EGG의 변화 연구)

  • Nam, Do-Hyun;Choi, Seong-Hee;Choi, Jae-Nam;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.1
    • /
    • pp.21-26
    • /
    • 2004
  • Vocal Register Transition(Passaggio) is one of the most important vocal technique for classically trined male singers(tenor). Passaggio is that it bridges the chest register to head register without a noticeable voice break. Vocalist gest the feeling that voice is not locked a particular register. The purpose of this study was to clarify the difference between easy($B_3$) tone and non passaggio(F#_4$) & passaggio(F#_4$). We selected 6 trained singers(tenor), who had more than 12.6 years of experience and were well trained in passaggio technique. Simulataneous measurement was performed frequency(F0), mean flow rate(MFR), intensity(I), and subglottal pressure(Psub) using a phonatory function analyzer(Nagashima) and Closed Quotient(CQ), Jitter, Shimmer, NHR a Electro-glottography(EGG) of Lx. Speech Studio(Laryngogrph Lt, London, UK) and vocal efficiency was calculated by Carroll's method. For the tenor, target tone/a/was measured in three conditions : 1) easy phonation : $B_3$, 2) high tone without passaggio : F#_4$, 3) high tone with passaggio : F#_4$). The results revealed that F0 of the target tones between non-passaggio group and passaggio group were not significantly different though higher is F0, higher is subglottal pressure. And also CQ, MFR, Psub were increased in passagio than nonpssagio but these values were not statistically different. This study concluded that passaggio is the vocal technique to make the same quality of tone between chest register and head register in tenor.

  • PDF

Eddy Current Testing using Encircling Differential Probe for Research Reactor Fuel Rods (외삽 차동형 탐촉자를 사용한 연구로용 핵연료봉의 와전류탐상)

  • Lee, Yoon-Sang;Kim, Chang-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.561-564
    • /
    • 2001
  • The cladding area of HANARO Research Reactor fuel rods should be checked not to have any defects larger than the size required at QA documents by using eddy torrent testing method doting fabrication process. To apply eddy current testing inspection to the fuel rods, encircling differential probes and standard specimen were designed and fabricated. The impedance of the fabricated probes was measured with impedance analyzer in order to cheek that the probe has a suitable impedance for the inspection frequency, and with this probe and MIZ-40A eddy current equipment, the detectability of this probes was investigated. The developed probes could detect artificial notch with 2mm length 10% depth of cladding thickness in cladding area. In addition, the probe was successfully applied to detect the defects in cladding area doting fabrication of the research reactor rods.

  • PDF

The Effect of Electrical Stimulation of Body Composition in Obese Person (전기자극이 체성분에 미치는 효과)

  • Kim, Yong-Seong;Bang, Sang-Bun
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.2 no.3
    • /
    • pp.13-24
    • /
    • 2004
  • The purpose of this study is to reveal the effect of electrical stimulation of body composition in obese person. Subjects were 30s to 40s aged healthy workers(2004. 3. 8~4. 17) in the S general Hospital in Suwon and they were brought to manage obesity. Subjects were divided into control group(Female<0.85, Male<0.90) and study group(Female>0.85, Male>0.90) by WHR(waist-hip ratio) that is measured by Automatic body composition analyzer(InBody 3.0). And we divided the study group with randomized methods into group A(n=8) and group B(n=8). Then we compared and analyzed the change of muscle mass, body fat, abdominal girth, WHR, BMI(body mass index) after application of electrical stimulation, three times a week, for 30 minutes in each session with 50 Hz of pulse frequency, $20\;{\mu}s$ or $250\;{\mu}s$ of pulse duration. There was statistically meaningful decrement of body fat(p<0.05) and abdominal girth(p<0.05) but not of body weight, muscle mass, WHR and BMI in the control group after application of electrical stimulation with 50 Hz, $20\;{\mu}s$. There were meaningful change of abdominal girth(p<0.05), WHR(p<0.05) and BMI(p<0.05), but not of body weight, muscle mass and body fat after application of electrical stimulation with 50 Hz, $20\;{\mu}s$ in group A. We applied electrical stimulation with 50 Hz, $250\;{\mu}s$ in group B, then there were meaningful change of body weight(p<0.05), body fat(p<0.01), abdominal girth(p<0.01), WHR(p<0.05) and BMI(p<0.01) but not of muscle mass only. Consequently, the pulse duration is the main parameter of electrical stimulation that affect the body composition of obese person in this study and if we combined the diet control to reduce blood components we could have better result. So it would be more effective to manage localized obesity(in abdomen, thigh, upper arm, etc.) if you apply electrical stimulation considering the pulse duration.

  • PDF

Investigation and measurement of indoor low voltage powerline impedance for high data rate powerline communications (PLC) (고속 전력선 통신용 옥내 저전압 전력선 임피던스 측정 및 특성 연구)

  • 박영진;김관호
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.8
    • /
    • pp.93-97
    • /
    • 2004
  • Since powerline for powerline communications (PLC) is designed for supplying electric power using 60 Hz wave, they will have different electrical behaviors for high data rate PLC whose bandwidth is allocated between 1 MHz and 30 MHz. Thus, it is necessary to investigate the different properties in this frequency bandwidth for the high data rate PLC. In this paper, low voltage (220V) powerline impedance for indoor high data rate PLC in between 1 MHz and 30 MHz is measured. For measurement a low voltage coupling unit is made and a vector network analyzer is used. A T-equivalent circuit of the low voltage coupling unit is obtained and then powerline impedance is derived by measuring the reflection coefficient of the total powerline network. With the method proposed, impedance is measured in case of a general korean apartment and its property is analyzed. Measurement shows that the average impedance is about 100Ω.

Design and Fabrication of the H-Type Slot Antenna with Bazooka Balun for a WiBro Repeater (WiBro 중계기용 Bazooka 발룬이 내장된 H형 슬롯 안테나의 설계 및 제작)

  • Choi, Won-Jun;Kim, Che-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.5
    • /
    • pp.515-522
    • /
    • 2008
  • In this paper, a slot antenna with built-in Bazooka balun aimed for a WiBro repeater was designed and fabricated. The return loss and radiation pattern of the slot antenna were improved due to the introduced Bazooka balun. This balun brings about even radiation pattern and keeps the stabilized coverage of repeater And it is easy to unite this balun with the antenna body by providing the terminal of Bazooka balun with screw shape. H-type slot was used to reduce the size of the antenna, and the slot antenna was fabricated in the structural symmetry with respect to a feeding point to afford the omni-directional radiation pattern. The simulated results were obtained by MWS(Microwave Studio Simulator) of CST company, and the measurement on the proposed antenna was conducted in an anechoic chamber equipped with a network analyzer and a far field measurement system. The measured peak gain shows 5.75 dBi and the average gain is above -0.8 dBi. The return loss remains below -12.35 dB for all frequency bands in WiBro regarded as a good performance.

Effect of Cholesterol-loaded-cyclodextrin in Presence and Absence of Egg Yolk during Freezing Step on Quality of Markhoz Buck's Spermatozoa

  • Farshad, A.;Amidi, F.;Khor, A. Koohi;Rashidi, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.2
    • /
    • pp.181-189
    • /
    • 2011
  • Cryopreservation protocols induce partially irreversible damage to mammalian sperm plasma membranes. Previous studies have indicated that adding cholesterol to the plasma membrane, as cholesterol-loaded-cyclodextrins, improves cryosurvival of sperm. Therefore, the purpose of this study was to determine if treating sperm of Markhoz bucks with cholesterol-loaded-cyclodextrins (CLC) (0, 0.75, 1.5, 2.25 and 3 mg/ml diluted $240{\times}10^6$ sperm/ml) in Tris-citric acid-glucose diluents with and without egg yolk (containing 5% glycerol) would improve the post-thaw sperm quality. The motion characteristics were evaluated with a Computer Assisted System Analyzer (CASA); acrosome integrity and vitality were measured with the triple-stain technique. Samples were recovered before and after freezing by means of putting straws into $37^{\circ}C$ water for 30 sec and then parameters were assessed. The results showed that the treatments significantly affected motility, progressive motility, recovery rate, curvilinear velocity, beat cross frequency, live sperm with reacted acrosome, live sperm with unreacted acrosome, dead sperm with reacted acrosorne, and dead sperm with unreacted acrosome during freezing (p<0.05). However; no significant differences were found for average path velocity, straight line velocity, amplitude of lateral head displacement, straightness and linearity (p>0.05). The best results were observed for extender containing 2.25 mg/ml ($240{\times}10^6$ sperm/ml) CLC supplemented with 2.6% egg yolk. In conclusion, the findings of this study indicate improved Markhoz sperm viability and motility following treatment in the presence of egg yolk.

A study on characteristics of magneto-dielectrics as the antenna substrate (안테나 기판으로 자성유전체 특성에 관한 연구)

  • Lee, Young-Soon;Yoo, Jin-Ha;Lee, Ga-Young;Cho, Yun-Ki;Kim, Ui-Jung;Oh, Byoung-Hee
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.6
    • /
    • pp.838-845
    • /
    • 2009
  • In order to obtain magneto-dielectrics with various permmittivity and permeability which could be used as the antenna substrate, various magneto-dielectrics compounded of dielectric materials(such as silicon and epoxy resin) and magnetic materials(such as carbonyl iron, barium and strontium powder) were fabricated. The relative permittivity and permeability of those were measured by use of HP 4291B impedance analyzer. Based upon the measured results, inverted-F meander monopole antennas(IFA) which were printed on the magneto-dielectric substrates fabricated as film type were designed and fabricated to investigate into variations of antenna characteristics such as the resonant frequency and impedance bandwidth in comparison with use of dielectric substrate. Some simulated and measured results for the designed IFA were presented. Characteristics of magneto-dielectrics which are different according as the choice of magnetic material or the composition ratio between magnetic material and dielectric material is different have been discussed.

  • PDF

A Study on Vibration Characteristics of Plate Structures Spot-Welded with respect to Area Ratio and Distance Ratio (점용접된 판 구조물의 면적비와 거리비에 따른 진동특성 연구)

  • Han, Dong-Seop;Ahn, Sung-Chan;Ahn, Chan-Woo;Han, Geun-Jo
    • Journal of Navigation and Port Research
    • /
    • v.26 no.1
    • /
    • pp.43-49
    • /
    • 2002
  • In this Paper, the mechanical behavior of two reかangular plates spot-welded under free vibration is investigated in detail. The focus of the analysis is to evaluate the effect of thickness of reinforced plates with equivalent thickness. The results of this the investigation are compared with detailed finite element analysis end experiments of the plates spot-welded for various parameters, such as aspect ratio, arm ratio, and distance ratio of spot-welding Points. The conclusion obtained are as followed. 1. The effect thickness due to spot-weld is very large, such as 55% in comparison with area ratio of spot-welding joint is just 4.52%. 2 The effect of thickness with respect to the distance ratio is maximized when the distance ratio is 0.4.

Annealing Effect in the Cold-Plastic Deformation of Amorphous PET Material (무정형 PET 재료의 플라스틱 냉간 변형에서의 열처리 효과)

  • Lee, Jong-Young;Park, Seong-Soo
    • Polymer(Korea)
    • /
    • v.25 no.1
    • /
    • pp.56-62
    • /
    • 2001
  • When polyethylene terephthalate(PET) film specimen were stepwise elongated under tension with various speeds of about 0.5~500 mm/min, the necking area, consisted of transparent and opaque bands, was formed during plastic deformation. Stress oscillation was apparently obtained in the stress-strain curve of above specimen. However, stress oscillation was not obtained in the stress-strain curve of annealing specimen. Microstructure was examined dynamically using an optical microscopy and thermal analysis was carried out in a differential scanning calorimeter at a heating rate of 10${\circ}$/min. Also, orientation and crystallization were examined using monochromatic-pinhole technique and elastic modulus was measured by a dynamic mechanical analyzer in the temperature range of -150~70 ${\circ}$ with the frequency of 1 Hz. Transparent PET products were fabricated by use of the PET pellets annealed at 83${\circ}$ for 30 min in an electric furnace.

  • PDF