• 제목/요약/키워드: Frequency Sweep

검색결과 150건 처리시간 0.026초

거리 측정용 주파수 변조 연속파 레이더 개발에 관한 연구 (A study on the Development of Frequency Modulated Continuous Wave Radar for Distance Measurement)

  • 박동국;한태경;이현수
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.1005-1010
    • /
    • 2005
  • In this paper, it is presented a frequency modulated continuous wave radar (FMCW) for distance measurement. The frequency range is $10{\sim}11$ GHz and the sweep time of the signal is 100 ms. The test target is 0.8 m2 of metal plate. The experiment is performed in open ground and the pyramidal horn antenna of about 22 dBi gain is used. The beat frequency according to the target moving to 40 m is measured. There is a good agreement between measured and calculated results. But the resolution of the FMCW radar is not good such as about 10 cm. It is result from the nonlinear signal of voltage controlled oscillator (VCO). To improve the nonlinear characteristic of VCO, a high pass filter and phase locked loop (PLL) frequency synthesizer are included in the radar system.

  • PDF

Experimental Evaluation of Frequency Characteristics of Gain-saturated EDFA for Suppression of Signal Fluctuation in Terrestrial Free-space Optical Communication Systems

  • Yoo Seok, Jeong;Chul Han, Kim
    • Current Optics and Photonics
    • /
    • 제7권1호
    • /
    • pp.28-32
    • /
    • 2023
  • Frequency characteristics of gain-saturated erbium-doped fiber amplifier (EDFA) are experimentally evaluated to mitigate the optical signal fluctuation induced by atmospheric turbulence in terrestrial freespace optical communication systems. Here, an acousto-optic modulator (AOM) is used to emulate optical signal fluctuations induced by atmospheric turbulence. The waveform which is generated in proportion to the refractive-index structural parameters is used to drive the AOM at various periodic frequencies. Thus, the dependence of the signal fluctuation suppression on the frequency is evaluated. The experiment is conducted using a periodic frequency sweep of the AOM driving voltage waveform and signal input power variation of the amplifier. It is observed that a low periodic frequency and high input signal power effectively suppress the optical signal fluctuation. This study evaluates the experimental results from the high-pass filter and gain-saturation characteristics of the EDFA.

고무의 동탄성계수와 손실계수의 주파수 의존성을 평가하기 위한 양팔 샌드위치보 시험법의 개발 (Development of a double cantilever sandwich beam method for evaluating frequency dependence of dynamic modulus and damping factor of rubber materials)

  • 김광우;최낙삼
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.19-22
    • /
    • 2001
  • This paper proposes a double cantilever sandwich-beam method for evaluating the frequency dependence of material dynamic characteristics. The flexural vibration of a double cantilever sandwich-beam specimen with a partially inserted rubber layer was studied using a finite element simulation in combination with the sine-sweep test. Quadratic relationships of dynamic elastic modulus and material loss factor of rubbers with frequency were quantitatively suggested employing the least square error method.

  • PDF

Determination of Frequency Independent Critical Concentration of Xathan and Carob Mixed Gels

  • Yoon, Won-Byong;Gunasekaran, Sundaram
    • Food Science and Biotechnology
    • /
    • 제16권6호
    • /
    • pp.1069-1071
    • /
    • 2007
  • The frequency independent critical concentration (Cc) of xanthan and carob (X/C) mixed gel was determined based on the Winter-Chambon's theory. X/C mixed (X/C=1:1 ratio) gels were prepared from 0.1 to 1% of concentration. The linear viscoelastic properties, i.e., storage and loss modulus, of X/C mixed gel at $20^{\circ}C$ were measured by frequency sweep tests. The frequency independence of tangent function of phase angle (tan ${\delta}$) of X/C mixed gels was graphically determined from the intersection of the plot of phase angle against concentration at varied frequencies. The intersection (C=0.43%) was considered to be Cc of X/C mixed gel.

부착식 텐던의 유효 긴장력 평가를 위한 최적의 매개변수 결정에 관한 연구 (A Study on the Determination of the Optimal Parameter for the Evaluation of the Effective Prestress Force on the Bonded Tendon)

  • 장정범;이홍표;황경민;송영철
    • 대한토목학회논문집
    • /
    • 제30권2A호
    • /
    • pp.161-168
    • /
    • 2010
  • 국내 가동 중 일부 원전의 원자로건물에 부착식 텐던이 설치되어 있고, 부착식 텐던에 대한 유효 긴장력 평가는 이들 원전의 계속운전을 위한 주요 현안으로 부각되고 있다. 따라서, 본 연구에서는 System Identification 기법을 이용한 부착식 텐던의 유효 긴장력 평가를 위하여, SI 기법에 유효한 주요 매개변수의 영향 평가를 수행하고 최적의 매개변수를 도출하였다. 본 연구를 위하여, 원자로건물 벽체의 1/5 축소모형 시험체를 제작하였고, 유효 긴장력과 고유진동수 및 변위와의 상관성을 분석하기 위하여 Impact test, SIMO sine sweep test 및 광섬유센서와 변위계에 의한 휨시험을 수행하였다. 시험결과, 고유진동수와 변위 모두 유효 긴장력과 좋은 상관성을 지니는 것으로 나타나, 이들 매개변수 모두 SI 기법의 입력자료로 활용되어 부착식 텐던의 유효 긴장력 예측이 가능한 것으로 분석되었다.

나노 가이드 시스템에서 초기 변위의 영향에 관한 연구 (Effect of an initial displacement on a nano-guiding system)

  • 이동연;이무연;권대갑;박준호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1396-1403
    • /
    • 2006
  • This study shows that the system performance of a positioning system composed of a piezoelectric actuator-driven flexure guide depends largely on the preload applied on the flexure guide and the driving input amplitude. We used a flexure guided system that had an original resonant frequency of 54Hz. Our experiment showed that we could increase the driving bandwidth above the original resonant frequency, for a case involving a large preload and a small input amplitude. Results show that there is a specific 'separation frequency' where the response of the moving mass of the flexure system decouples from the response oi the piezoelectric actuator, and this specific separation frequency can be selected by a proper choice of the preload and the input amplitude. To find the separation frequency, sine sweep tests were performed. To confirm the increased system bandwidth frequency, open-loop sine tracking experiments were performed. Test results show that the system responds very well up to 130 Hz frequency higher than the original natural frequency (54Hz).

  • PDF

나노 가이드 시스템에서 초기 변위의 영향에 관한 연구 (Effect of an Initial Displacement on a Nano-guiding System)

  • 이무연;권대갑;이동연
    • 한국소음진동공학회논문집
    • /
    • 제16권4호
    • /
    • pp.346-354
    • /
    • 2006
  • This study shows that the system performance of a positioning system composed of a piezoelectric actuator-driven flexure guide depends largely on the preload applied on the flexure guide and the driving input amplitude. We used a flexure guided system that had an original resonant frequency of 54 Hz. Our experiment showed that we could increase the driving bandwidth above the original resonant frequency, for a case involving a large preload and a small input amplitude. Results show that there is a specific 'separation frequency' where the response of the moving mass of the flexure system decouples from the response of the piezoelectric actuator, and this specific separation frequency can be selected by a proper choice of the preload and the input amplitude. To find the separation frequency, sine sweep tests were performed. To confirm the increased system bandwidth frequency, open-loop sine tracking experiments were performed. Test results show that the system responds very well up to 130 Hz frequency higher than the original natural frequency (54 Hz).

Experimental study on models of cylindrical steel tanks under mining tremors and moderate earthquakes

  • Burkacki, Daniel;Jankowski, Robert
    • Earthquakes and Structures
    • /
    • 제17권2호
    • /
    • pp.175-189
    • /
    • 2019
  • The aim of the study is to show the results of complex shaking table experimental investigation focused on the response of two models of cylindrical steel tanks under mining tremors and moderate earthquakes, including the aspects of diagnosis of structural damage. Firstly, the impact and the sweep-sine tests have been carried out, so as to determine the dynamic properties of models filled with different levels of liquid. Then, the models have been subjected to seismic and paraseismic excitations. Finally, one fully filled structure has been tested after introducing two different types of damages, so as to verify the method of damage diagnosis. The results of the impact and the sweep-sine tests show that filling the models with liquid leads to substantial reduction in natural frequencies, due to gradually increasing overall mass. Moreover, the results of sweep-sine tests clearly indicate that the increase in the liquid level results in significant increase in the damping structural ratio, which is the effect of damping properties of liquid due to its sloshing. The results of seismic and paraseismic tests indicate that filling the tank with liquid leads initially to considerable reduction in values of acceleration (damping effect of liquid sloshing); however, beyond a certain level of water filling, this regularity is inverted and acceleration values increase (effect of increasing total mass of the structure). Moreover, comparison of the responses under mining tremors and moderate earthquakes indicate that the power amplification factor of the mining tremors may be larger than the seismic power amplification factor. Finally, the results of damage diagnosis of fully filled steel tank model indicate that the forms of the Fourier spectra, together with the frequency and power spectral density values, can be directly related to the specific type of structural damage. They show a decrease in the natural frequencies for the model with unscrewed support bolts (global type of damage), while cutting the welds (local type of damage) has resulted in significant increase in values of the power spectral density for higher vibration modes.

동적전단유동하에서 측정된 시멘트 페이스트의 히스테리시스곡선 (Hysteresis Loops of cement Paste Measured by Oscillatory Shear Experiments)

  • L. Erwin
    • 유변학
    • /
    • 제5권2호
    • /
    • pp.99-108
    • /
    • 1993
  • 시멘트 페이스트의 비선형적 점탄성 거동을 연구하기 위해 동적인 전단 유동 시험 이 수행되었다. 전단응력과 전단변형 또는 전단변형율간의 관계를 보여주는 히스테리시스 곡선을 얻기 위하여 전단응력이 연속적으로 측정되었다. 이는 기존의 주파수 혹은 변형의 증가에 의한 실험(frequency or strain sweep experiment)과는 달리 저자에 의해 수정된 점 성계(HAAKE Model RV20/RC20/CV20N)의 조정프로그램을 이용하여 수행되었다. 동적 전 단유동시험에서 얻어진 히스테리시스곡선은 시멘트 페이스트가 전단변형을 받는 동안 선형 탄성, 입자간 연결고리의 파괴 및 점성유체 거동을 보여준다. 측정된 항복전단응력은 전단변 형율의 증가에 따라 파우어함수(Power low equation)에 의해 증가함을 보여준다.

  • PDF

FIV 시험루프의 유동기인 진동 신호분석 (Flow-Induced Vibration Signal Analysis of the FIV Test Loop)

  • 이강희;강흥석;윤경호;송기남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.601-606
    • /
    • 2004
  • Vibration spectrums of the test loop according to flow conditions were analyzed in order to identify the sources of vibration at peak frequencies. While a flow condition of the sweep test was changed by varying pump rotational speed from 450 rpm to 1500 rpm by the step 150 rpm, midspan acceleration of the test section in width-direction and dynamic pressure perturbation in the test section were measured. Other sources of vibration due to the flow structure interactions, such as acoustic resonance, blade pulsing frequency and bellows wrinkles, were investigated. Pressure perturbation in the section and acoustic resonance due to branch pipe give major effects to the vibration of the test section in high frequency range of 1.5 kHz to 2.8 kHz.

  • PDF