• Title/Summary/Keyword: Frequency Sensitivity

Search Result 1,526, Processing Time 0.028 seconds

Implantable Flexible Sensor for Telemetrical Real-Time Blood Pressure Monitoring using Polymer/Metal Multilayer Processing Technique (폴리머/ 금속 다층 공정 기술을 이용한 실시간 혈압 모니터링을 위한 유연한 생체 삽입형 센서)

  • Lim Chang-Hyun;Kim Yong-Jun;Yoon Young-Ro;Yoon Hyoung-Ro;Shin Tae-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.599-604
    • /
    • 2004
  • Implantable flexible sensor using polymer/metal multilayer processing technique for telemetrical real-time blood pressure monitoring is presented. The realized sensor is mechanically flexible, which can be less invasively implanted and attached on the outside of blood vessel to monitor the variation of blood pressure. Therefore, unlike conventional detecting methods which install sensor on the inside of vessel, the suggested monitoring method can monitor the relative blood pressure without injuring blood vessel. The major factor of sudden death of adults is a disease of artery like angina pectoris and myocardial infarction. A disease of circulatory system resulted from vessel occlusion by plaque can be preventable and treatable early through continuous blood pressure monitoring. The procedure of suggested new method for monitoring variation of blood pressure is as follows. First, integrated sensor is attached to the outer wall of blood vessel. Second, it detects mechanical contraction and expansion of blood vessel. And then, reader antenna recognizes it using telemetrical method as the relative variation of blood pressure. There are not any active devices in the sensor system; therefore, the transmission of energy and signal depends on the principle of mutual inductance between internal antenna of LC resonator and external antenna of reader. To confirm the feasibility of the sensing mechanism, in vitro experiment using silicone rubber tubing and blood is practiced. First of all, pressure is applied to the silicone tubing which is filled by blood. Then the shift of resonant frequency with the change of applied pressure is measured. The frequency of 2.4 MHz is varied while the applied pressure is changed from 0 to 213.3 kPa. Therefore, the sensitivity of implantable blood pressure is 11.25 kHz/kPa.

Vulnerability Assessment of Cultivation Facility by Abnormal Weather of Climate Change (이상기후에 의한 재배시설의 취약성 평가)

  • Yoon, Seong-Tak;Lee, Yong-Ho;Hong, Sun-Hee;Kim, Myung-Hyun;Kang, Kee-Kyung;Na, Young-Eun;Oh, Young-Ju
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.15 no.4
    • /
    • pp.264-272
    • /
    • 2013
  • Climate changes have caused not only changes in the frequency and intensity of extreme climate events, but also temperature and precipitation. The damages on agricultural production system will be increased by heavy rainfall and snow. In this study we assessed vulnerability of crop cultivation facility and animal husbandry facility by heavy rain in 232 agricultural districts. The climate data of 2000 years were used for vulnerability analysis on present status and the data derived from A1B scenario were used for the assessment in the years of 2020, 2050 and 2100, respectively. Vulnerability of local districts was evaluated by three indices such as climate exposure, sensitivity and adaptive capacity, and each index was determined from selected alternative variables. Collected data were normalized and then multiplied by weight value that was elicited in delphi investigation. Jeonla-do and Gangwon-do showed higher climate exposures than the other provinces. The higher sensitivity to abnormal weather was observed from the regions that have large-scale cultivation facility complex compared to the other regions and vulnerability to abnormal weather also was higher at these provinces. In the projected estimation based on the SRES A1B, the vulnerability of controlled agricultural facility in Korea totally increased, especially was dramatic between 2000's and 2020 year.

Clinical Observation on C.V.A with Diabetes Mellitus (당뇨병(糖尿病) 환자(患者)에 병발(倂發)된 뇌졸중(腦卒中)의 임상적(臨床的) 고찰(考察))

  • Yoon, Cheol-Ho;Seo, Un-Kyo;Jeong, Ji-Cheon
    • The Journal of Internal Korean Medicine
    • /
    • v.15 no.1
    • /
    • pp.22-44
    • /
    • 1994
  • Clinical observations were done on 67 cases with Diabetes Mellitus in CVA patients who were confirmed by CT scan and observed for over 1 week, admitted to the Dept. of Internal Medicine in Oriental Medical Hospital of Dongguk University from January 1992 to December 1993. The results were as follows; 1. 86 patients (15.3%) with Diabetes Mellitus were found in 561 CVA patients, the 6th decade of age was 40.2%, the ratio of male to female was 0.72:1. 2. The local distribution of CVA was similar to common CVA, and occlusive CVD was 83.6%, cerebral hemorrhage was 16.4% in this study. 3. The association between blood glucose and years were not significant. The largest ratio of fasting blood glucose were 140-199 mg/dl (44.6%) in admission, below 139 mg/dl (51.8%) in discharge in case of occlusive CVD. In cerebral hemorrhage, that were 140-199 mg/dl(45.5%) in dmission, below 139 mg/dl (45.5%) in discharge. The largest ratio of pp2hrs blood glucose were 200-299mg/dl in admission and discharge both occlusive CVD and cerebral hemorrhage. 4. The total sensitivity of urine glucose was 71.6%, and sensitivity of urine glucose in cerebral hemorrhage (81.8%) was more higher than that of occlusive CVD (69.6%). 5. Below 4 years had the highest prevalence(44.8%) in duration of diabetes mellitus. Patients usually used oral hypoglycemic agents(41.8%), insulin injection(23.9%) treatment and non-therapeutic was 17.9% in this study. 6. Predisposing factors and symptoms in admissin were similar to common CVA. The conscious disturbance on attacck was 41.1% in occlusive CVD, and that was 63.7% in cerebral hemorrhage. 7. The most common ratio of the season's attack was spring (44.8%), 8. The frequency of post history was as follows, hypertension (44.8%), heart disease (10.4%), and they were in below 199 mg/dl (83.3%) of fasting blood glucose. 9. The family history of CVA was 46.3%, and they was higher than nondiabetic patients. 10. The recurrence rate of CVA was 28.4%, and that of occlusive CVD(28.6%) was higer than cerebral hemorrhage's (18.2%). 11. The smoker was 52.2%, the drinker was 38.9%. 12. The complications was occured in 10 cases (14.9%) after admission, and they frequently occured than common CVA. 13. In admission, the ratio of systolic blood pressure in over l60mmHg was 42.9%, that of diastolic blood pressure in over l00mmHg was 12.5% in occlusive CVD. In cerebral hemorrhage, the ratio of systolic blood pressure in over l60mmHg was 54.5%, that of diastolic blood pressure in over l00mmHg was 27.3%. 14. The average beginned time of physical theraphy was, generally lated, 8.3 days in occlusive CVD, 11.2 days in cerebral hemorrhage. Average admitted period was longer than common CVA, and was 29.2 days in occlusive CVD, 11.2 days in cerebral hemorrhage. 15. The degree of recovery were 82.1% in occlusive CVD, 72.7% in cerebral hemorrhage. 16. The herb medications were various Sunghyanggeonggisans, Sopungtang, Ganghwalyupungtang, Yanggyuksan etc. were used most frequently, and Yukmijihwangtang, Gamidaebotang, Mangeumtang etc. were used as discharge.

  • PDF

The role of $Na^+-Ca^{2+}$ exchange on calcium activated chloride current in single isolated cardiac myocyte in pulmonary vein of rabbit.

  • Kim, Won-Tae;Lee, Yoon-Jin;Ha, Jeong-Mi;Han Choe;Jang, Yeon-Jin;Park, Chun-Sik;Lee, Chae-Hun m
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 2003.06a
    • /
    • pp.37-37
    • /
    • 2003
  • We have shown the $Ca^{2+}$-activated chloride current is present in cardiac myocyte in rabbit pulmonary vein (Kim et al., 2002). This current amplitude was increased as [N $a^{+}$]$_{i}$ was increased and we suggested this chloride current may be involve in the spontaneous action potential frequency change. Since this current is activated by the increase of intracellular $Ca^{2+}$, we would like to test what is the inducer of the increase of [C $a^{2+}$]$_{i}$ between a L-type $Ca^{2+}$-current or a reverse mode of N $a^{+}$-C $a^{2+}$ exchange current. White rabbit (1.5 kg) was used and anesthetized with Ketamin (100 mg/kg). Pulmonary vein (PV) was isolated and sleeve area between left atrium and PV was dissected. Using collagenase (Worthington 0.7 mg/cc), single cardiac myocytes were isolated. In the presence of 15 mM of N $a^{+}$, three steps of voltage pulses were applied (holding potential : -40 ㎷, -80 ㎷ for 50 msec, 30 ㎷ for 5 msec, 10 ㎷ steps from -70 ㎷ to 60 ㎷). The inward and outward tail current was activated after brief 5 msec prepulse. The outward tail current was blocked by the removal of extracellular chloride substituted by glucuronic acid or by a chloride channel blocker, 5 mM 9-AC. But the inward tail current was still remained even though the amplitude was decreased. The reversal potentials were changed to the direction of the change of chloride equilibrium potential ( $E_{Cl}$ ) but the shift of equilibrium potential was not enough to match to the theoretical equilibrium potential shift. In the presence of L-type $Ca^{2+}$ channel blocker, nifedipine 1 uM, inward tail currents were greatly reduced but the outward current tail currents were still remained. In the presence of N $a^{+}$-C $a^{2+}$ exchange current blocker, 10 uM KB-R7943, the inward and outward tail currents were blocked almost completely. We tried to test the $Ca^{2+}$sensitivity of the chloride current with various [C $a^{2+}$]$_{i}$ in pipette solution from 100 nM to 1 uM but we failed to activate $Ca^{2+}$-activated chloride currents even though the cell became contracted in the presence of 1 uM $Ca^{2+}$. From these results, we could conclude that the increase of [C $a^{2+}$]$_{i}$ to activate the outward $Ca^{2+}$-activated chloride current was mainly induced by the activation of the reverse mode of N $a^{+}$-C $a^{2+}$ exchanger, But for the increase of [C $a^{2+}$]$_{i}$ to activate the inward tail current, L-type $Ca^{2+}$ current may be the major provoking current. Since the cytosolic increase of [C $a^{2+}$]$_{i}$ through pipette solution have failed to activate $Ca^{2+}$-activated chloride current, this chloride current may have very low $Ca^{2+}$ sensitivity or a comparmental increase $Ca^{2+}$ such as in subsarcolemmal space may activate the chloride current. Since there are several reports and models that the increase of $Ca^{2+}$ in subsarcolemmal space would be over several to tens of uM, both possibility may be valid together.uM, both possibility may be valid together.

  • PDF

Development of a split beam transducer for measuring fish size distribution (어체 크기의 자동 식별을 위한 split beam 음향 변환기의 재발)

  • 이대재;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.196-213
    • /
    • 2001
  • A split beam ultrasonic transducer operating at a frequency of 70 kHz to use in the fish sizing echo sounder was developed and the acoustic radiation characteristics were experimentally analyzed. The amplitude shading method utilizing the properties of the Chebyshev polynomials was used to obtain side lobe levels below -20 dB and to optimize the relationship between main beam width and side lobe level of the transducer, and the amplitude shading coefficient to each of the elements was achieved by changing the amplitude contribution of elements with 4 weighting transformers embodied in the planar array transducer assembly. The planar array split beam transducer assembly was composed of 36 piezoelectric ceramics (NEPEC N-21, Tokin) of rod type of 10 mm in diameter and 18.7 mm in length of 70 kHz arranged in the rectangular configuration, and the 4 electrical inputs were supplied to the beamformer. A series of impedance measurements were conducted to check the uniformity of the individual quadrants, and also in the configurations of reception and transmission, resonant frequency, and the transmitting and receiving characteristics were measured in the water tank and analyzed, respectively. The results obtained are summarized as follows : 1. Average resonant and antiresonant frequencies of electrical impedance for four quadrants of the split beam transducer in water were 69.8 kHz and 83.0 kHz, respectively. Average electrical impedance for each individual transducer quadrant was 49.2$\Omega$ at resonant frequency and 704.7$\Omega$ at antiresonant frequency. 2. The resonance peak in the transmitting voltage response (TVR) for four quadrants of the split beam transducer was observed all at 70.0 kHz and the value of TVR was all about 165.5 dB re 1 $\mu$Pa/V at 1 m at 70.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The resonance peak in the receiving sensitivity (SRT) for four combined quadrants (quad LU+LL, quad RU+RL, quad LU+RU, quad LL+RL) of the split beam transducer was observed all at 75.0 kHz and the value of SRT was all about -177.7 dB re 1 V/$\mu$Pa at 75.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The sum beam transmitting voltage response and receiving senstivity was 175.0 dB re 1$\mu$Pa/V at 1 m at 75.0 kHz with bandwidth of 10.0 kHz, respectively. 3. The sum beam of split beam transducer was approximately circular with a half beam angle of $9.0^\circ$ at -3 dB points all in both axis of the horizontal plane and the vertical plane. The first measured side lobe levels for the sum beam of split beam transducer were -19.7 dB at $22^\circ$ and -19.4 dB at $-26^\circ$ in the horizontal plane, respectively and -20.1 dB at $22^\circ$ and -22.0 dB at $-26^\circ$ in the vertical plane, respectively. 4. The developed split beam transducer was tested to estimate the angular position of the target in the beam through split beam phase measurements, and the beam pattern loss for target strength corrections was measured and analyzed.

  • PDF

Distribution of Yeast Isolated from Clinical Specimens at a University Hospital in last Five Years (최근 5년간 단일 대학병원의 임상검체에서 분리된 효모균의 분포)

  • Seo, Choong-Won;Yu, Young-Bin;Shin, Kyeong Seob;Kim, Young-Kwon
    • Journal of Digital Convergence
    • /
    • v.12 no.9
    • /
    • pp.237-244
    • /
    • 2014
  • Pathogenic fungal infections are predominantly occurred in patients with severe immune or metabolic defects. In the present study, we aimed to investigate the last five years (2007~2011) 190,250 cases clinical specimens of yeast 3,487 results that had shown positive culture and to look at the significance of regional difference and identify relationship between provide the characteristics about association between clinical isolates and gender, age, and type of specimens. The yearly strain-specific isolation frequency of yeast separated was 1,925(55.2%) for C. albicans the largest of them. All kinds of clinical specimen was 1,495(42.9%) in urine, 998(28.6%) in sputum. Strain-specific gender differences in C. albicans for males was 1,177(57.8%) of the total of 2,037 and 748(51.6%) of 1,450 and as for age, those between 70 and 79 were the largest with 639(55.1%) of the 1,925 strain. In this study, well presented the general characteristics of pathogenic yeast seen in diverse specimens. This limitation has been implemented in a single area, Future research is expected to examine more on nationwide distribution chart, dynamic characteristics and future antibiotic sensitivity.

Designing and Realizing the Ground Station Receiver Low Noise Amplifier of the Next-Generation Aeronautical Surveillance System (차세대 항공 감시시스템(ADS-BES) 지상국 수신기 저잡음 증폭기 설계 및 구현)

  • Cho, Ju-Yong;Yoon, Jun-Chul;Park, Chan-Sub;Park, Hyo-Dal;Kang, Suk-Youb
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.10
    • /
    • pp.2273-2280
    • /
    • 2013
  • This article introduces the next-generation air surveillance system and investigates how to design of front-end low noise amplifier of the ground station receiver. In consideration of the international standard documentation and the performance of existing products, the study conducts the link budget on the entire system so that it can be competitive in terms of receive sensitivity or reliability. To obtain a proper low noise amplifier, standards of design are decided so that such factors as gain, gain flatness, and reflective loss can be optimal. In its design, the bias circuit appropriate for the characteristics of low power, low noise, or high gain was built, and according to the results of the simulation conducted after the optimal design, its gain was 16.24dB, noise factor was 0.36dB, input-output reflective loss was -18dB and -28dB each, and frequency stability was 1.11. According to the results measured after the design, its gain was 17dB, noise factor was 0.51dB, gain flatness was 0.23dB, and input-output reflective loss was -18.28dB and -24.50dB each, so the results gained were suitable for building the overall system.

Study of expression in virtual character of facial smile by emotion recognition (감성인식에 따른 가상 캐릭터의 미소 표정변화에 관한 연구)

  • Lee, Dong-Yeop
    • Cartoon and Animation Studies
    • /
    • s.33
    • /
    • pp.383-402
    • /
    • 2013
  • In this study, we apply the facial Facial Action Coding System for coding the muscular system anatomical approach facial expressions to be displayed in response to a change in sensitivity. To verify by applying the virtual character the Duchenne smile to the original. I extracted the Duchenne smile by inducing experiment of emotion (man 2, woman 2) and the movie theater department students trained for the experiment. Based on the expression that has been extracted, I collect the data of the facial muscles. Calculates the frequency of expression of the face and other parts of the body muscles around the mouth and lips, to be applied to the virtual character of the data. Orbicularis muscle to contract end of lips due to shrinkage of the Zygomatic Major is a upward movement, cheek goes up, the movement of the muscles, facial expressions appear the outer eyelid under the eye goes up with a look of smile. Muscle movement of large muscle and surrounding Zygomatic Major is observed together (AU9) muscles around the nose and (AU25, AU26, AU27) muscles around the mouth associated with openness. Duchen smile occurred in the form of Orbicularis Oculi and Zygomatic Major moves at the same time. Based on this, by separating the orbicularis muscle that is displayed in the form of laughter and sympathy to emotional feelings and viable large muscle by the will of the person, by applying to the character of the virtual, and expression of human I try to examine expression of the virtual character's ability to distinguish.

Quantitative Sensory Test: Normal Range in Korean Adults and Application to Diabetic Polyneuropathy (정량적 감각 검사: 한국인에서의 연령별 정상 범위 및 당뇨병성 다발신경병증에서의 유용성 평가)

  • Kim, Su-Hyun;Kim, Sung-Min;Ahn, Suk-Won;Hong, Yoon-Ho;Park, Kyung-Seok;Sung, Jung-Joon;Lee, Kwang-Woo
    • Annals of Clinical Neurophysiology
    • /
    • v.12 no.1
    • /
    • pp.21-26
    • /
    • 2010
  • Background: Although quantitative sensory test (QST) is being used with increasing frequency for measuring sensory thresholds in clinical practice and epidemiologic studies, there has been no age-matched normative data in Korean adults. The objective of this study is to evaluate the value of QST in diabetic polyneuropathy with normal range in Korean adults. Methods: The Computer Aided Sensory Examination IV 4,2 (WR Medical Electronics Co., Stillwater, Minnesota, U.S.A.), with 4,2,1 stepping algorithm was used to determine vibration and cold perception threshold in 70 normal controls and 19 patients with diabetic polyneuropathy aged from 21 to 79 years. The data were used to define age-matched upper and lower normal limits and normal range of side to side difference. We also evaluated the duration of diabetes, serum HbA1C level, and findings of nerve conduction study (NCS) and QST in patients with diabetic polyneuropathy. Results: In normal adults, sensory thresholds slightly increased with age, and a slight side-to-side difference was observed. The diagnostic sensitivity of QST was not higher than NCS in patients with diabetic polyneuropathy (36.8% vs. 42.1%, p=0.716), especially among elderly patients. Conclusions: QST might be used as a complementary test for NCS in the diagnosis of diabetic polyneuropathy. Although the QST is a simple method for the evaluation of peripheral nerve function, there are some limitations. Most of all, because the QST measuring is dependent on the subjective response of patients, the degree of concentration and cooperation of the patients can significantly affect the result. And thus, attention should be paid during the interpretation of QST results in patients with peripheral neuropathy.

AC-DC Transfer Characteristics of a Bi-Sb Multijunction Thermal Converter (Bi-Sb 다중접합 열전변환기의 교류-직류 변환 특성)

  • 김진섭;이현철;함성호;이종현;이정희;박세일;권성원
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.11
    • /
    • pp.46-54
    • /
    • 1998
  • A planar Bi-Sb multijunction thermal converter, which is consisted of a linear or bifilar thin film NiCr-heater and a thin film Bi-Sb thermopile, has been fabricated, and its ac-dc transfer characteristics were examined in a frequency range from 10 Hz to 10 KHz. In order to increase the thermal sensitivity and to decrease the ac-dc transfer error of a thermal converter, the heater and the hot junctions of a thermopile were prepared on a Si$_3$N$_4$/SiO$_2$/Si$_3$N$_4$-diaphragm which acts as a thermal isolation layer, and the cold junctions on the Si$_3$N$_4$/SiO$_2$/Si$_3$N$_4$-thin film supported with the silicon rim which functions as a heat sink. The respective thermal sensitivities in air and in a vacuum of the converter with a built-in bifilar heater were about 14.0 ㎷/㎽ and 54.0 ㎷/㎽, and the ac-dc voltage and the current transfer difference ranges in air were about $\pm$0.60 ppm and $\pm$0.11 ppm, respectively, indicating that the ac-dc transfer accuracy of the converter are much higher than that of a commercial 3-dimensional multijunction thermal converter. However, the output thermoelectric voltage fluctuation of the converter was rather high.

  • PDF