• Title/Summary/Keyword: Frequency Recovery

Search Result 679, Processing Time 0.024 seconds

Robust Symbol Timing Recovery for Telephone tine Modems

  • Hwang, Sung-Hyun;Park, Hyun-Cheol k;Park, Hyung-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1819-1822
    • /
    • 2002
  • The authors propose a robust symbol timing recovery (STR) for telephone line modems supporting data rates up to 32 Mbps. The STR is initialized by a start signal from carrier sensor, and the novel method is proposed which resolves the difference between the frequency of the transmitter's clock and the receiver's clock, called baud frequency offset. The proposed method is applied on digital receiver in a 16 frequency diverse quadrature amplitude modulation (FDQAM) system.

  • PDF

Design of Carrier Recovery Loop for QPSK Demodulator (QPSK 복조기를 위한 반송파 복구 회로 설계)

  • 하창우;김형균;김환용
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.85-88
    • /
    • 2000
  • In order to resolve problems according to the phase error in QPSK demodulator of the digital communication systems. The demodulator requires carrier recovery loop which searches for the frequency and phase of the carrier. In this paper the complexity of implementation is reduced by the reduction into half of the number of the multiplier in filter structure of the conventional carrier recovery loop, and as the drawback of NCO of the conventional carrier recovery loop wastes a amount of power for the structure of lookup table , We designed the structure of combinational logic without the lookup table. In the comparison with dynamic power of the proposed NCO, the power of NCO with the lookup table is 175㎼, NCO with the proposed structure is 24.65㎼. As the result, it is recognized that about one eight of loss power is reduced. In the simulation of carrier recovery loop designed QPSK demodulator, it is known that the carrier phase is compensated.

  • PDF

Currant Source GTO Inverter with Double Recovery Path of Commutation Energy by LCD (수동소자에 의한 축적에너지 2중 궤환방식 전류형 GTO 인버터의 입.출력 특성)

  • Kim, Jin-Pyo;Choi, Sang-Won;Lee, Jong-Ha
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2104-2106
    • /
    • 1997
  • In order to develop the three phase GTO CSI with double recovery path of commutation energy by passive devices (LCD), we studied the clamping circuit to protect switching device and energy recovery circuit to recover absorbed energy of capacitor and DC inductor. In this paper, we investigated how DC input power is increased or decreased according to energy recovery path with or not in the three phase GTO current source inverter, we used a induction motor as inverter load, and controlled a induction motor with v/f constant control. Experimental results show that dissipated DC power is decreased in $9{\sim}14%$ by double recovery path. We also confirmed that the characteristics is met as compare simulation results with experimental results according to each frequency.

  • PDF

Design and Fabrication of Synchronous Clock Recovery Module for S-DMB GaP Filler (위성 DMB 중계기의 동기용 클럭 재생 모듈 설계 및 제작)

  • Chang, Lae-Kyu;Park, Eun-Hee;Lee, Hang-Soo;Hong, Sung-Yong;Park, Jung-Seo
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.107-110
    • /
    • 2005
  • This paper describes the design and fabrication of synchronous clock recovery module for S-DMB Gap Filler. Using the 2.304MHz TTL signal from gap filler tuner, clock recovery module with 10MHz output frequency including holdover function is designed. The measured performance of the clock recovery module shows a stability of less than 0.01ppm, 29 sec stability time, 10 sec holdover time, and maximum -113dBc/Hz@100Hz phase noise.

  • PDF

A study on the optimal distance between the data center and the disaster recovery center for the business continuity (업무 연속성 확보를 위한 재해복구센터의 최적 거리에 관한 연구)

  • 서용원
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2003.11a
    • /
    • pp.57-60
    • /
    • 2003
  • As the business dependency to information systems and the frequency of the large scale disasters increase, implementing the disaster recovery center has been a common practice. However, since there has been little quantitative decision method for the distance between the data center and the disaster recovery center, the distance decision has been commonly made by qualitative guidelines. In this research, the decision method for the optimal distance between the data center and the disaster recovery center is developed, using the cost analysis including the operation cost and the expected disaster cost. An illustrative numerical example is provided.

  • PDF

Surface Elevation Recovery Methods from Pressure Gage for Irregular Waves (불규칙파(不規則波에) 대한 압력식(壓力式) 파고계(波高計)의 적용성(適用性)에 관한 연구(研究))

  • Kwon, Jung Gon;Kang, Ju Bok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.4_1
    • /
    • pp.129-136
    • /
    • 1992
  • A precedure for recovering surface displacement from a time series of pressure measured by a pressure gage in a shallow water (that is, FFTM, LCM. IWM) is investigated with respect to a proper cut-off-frequency of a frequency response function for the accurate recovery of wave height and period. The authors examined the applicability of above mentioned three transformation procedures through field observations and laboratory experiments and the following results are obtained. i) The cut-off-frequency of the frequency response function used in FFTM is deeply depend on both the frequency response of the pressure sensor and the water depth at the sensor. In this study, a relatively accurate surface displacement can be recovered when the frequency response function is cut off at the frequency corresponding to kh=3.0 where k is a wave number at the depth of h. The frequency response function in the region higher than the cut-off-frequency is set constant to be the value at the cut-off-frequency. ii) The transformed surface displacements by LCM are affected by the small waves of short periods included in the measured pressure. It is found that pressure variation whose local frequency is higher than kh=1.5 has to be neglected to recover surface displacement sufficiently. iii) In IWM, the linear pressure response function is usually utilized by multiplying a coefficient N which is a function of the frequency (or kh) and takes a value around unity. However, in this study, a constant value of N(=1.0) gives a relatively accurate recovery of surface displacements.

  • PDF

A Study on the Optimal Load Shedding Method under Large Generator Outage (대전원 탈락사고시 최적부하 차단방법에 관한 연구)

  • 유현재;정재길
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.2
    • /
    • pp.35-41
    • /
    • 1995
  • This paper proposes an adaptive methodology for setting of the underfrequency relays that is based on the initial rate of change of the frequency decline to protect for excess frequency decline of power system under large generator outage. The strategy of the load shedding is as follows : Let the load shedding of the first step occur when the frequency reaches 59.5 (Hz), and the load shedding power of this first and second step be one half of the total "Static Load Shed" value for any given disturbance size based on the initial rate of change of the frequency. As a results, it is verified that the use of the proposed method is more efficient than the conventional method in the characteristic of the frequency recovery. recovery.

  • PDF

Resonant Frequency Recovery of Resonator for Magnetic Resonant Wireless Power Transfer Inserted into Dielectric Material (유전체에 삽입된 자기공진형 무선전력전송 공진기의 공진주파수 복원에 관한 연구)

  • Kang, Seok Hyon;Jung, Chang Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.12
    • /
    • pp.992-995
    • /
    • 2018
  • The wireless charging of body-embedded medical instruments and wireless power transfer to various inside dielectric-materials is still a future technology that has not yet been achieved. This paper proposes methods for controlling the capacitance of the resonators and installing air pockets on the top and bottom sides of the resonators for optimal design, which considered efficiency and resonant frequency in accordance with the electromagnetic characteristics of the dielectric medium. In future, the results of this research will be utilized as the basic research data to design and restore resonant frequency of resonators embedded in various dielectric environments.

Analysis of Anesthesia and Recovery Room Nurses's Activities (일 대학 병원 마취${\cdot}$회복실 간호사의 간호활동 분석)

  • Kang, Yoon-Kyung;Kim, Kyoung-Mee;Kim, Yon-Yi;Park, Hae-Ok;Seo, Kwang-Hee;Song, Song;Lee, Hyun-Suk;Cho, Eui-Young
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.12 no.1
    • /
    • pp.63-75
    • /
    • 2006
  • Purpose: This study was aimed to specify roles of nurses from the anesthesia and recovery room by analyzing nursing activities as well as anesthesia nursing during surgery. Method: The objects were 12 RNs working in the recovery room of a university hospital located in Incheon. Self-report was performed by measuring stop-watch for five days from May 17th to May 21st in 2004. Research method was designed to record the time and frequency of the nursing activity from anesthesia and recovery room based on nurses' statement and other references for five days. The data were analyzed with descriptive statistics, ANOVA, and t-test via SPSS Win 10.0 program. Result: Nursing activities in anesthesia recovery room were classified into two different characteristics such as direct and indirect nursing activity. The activities consisted of 11 direct nursing areas and 39 nursing activities in anesthesia preparation room. The indirect nursing was classified into 8 nursing areas and 32 nursing activities. The direct nursing was classified into 12 nursing areas and 55 nursing activity. Also, the indirect nursing was classified into 7 nursing areas and 21 nursing activities in recovery room. In terms of prevalence of nursing activities in the anesthesia preparation room, observation and cooperation of anesthesia was the most prevalent activity, drug and eqipment management the second prevalent, and drug administration the third. On the other hand, in the recovery room, the most prevalent activity was vital sign checking and observation, the second most prevalent activity informative activity, and the third body temperature control. Nursing activity time was recorded according to the nursing characteristics. In the anesthesia preparation room, the direct nursing spent for 8092.20 minutes was larger than the indirect nursing spent for 7198.50 minutes. Also, in the recovery room, the direct nursing spent for 2361.16 minutes was larger than the indirect nursing spent for 1134.13 minutes. 4. Nursing activity time was compared to duty shifts. In the anesthesia preparation room, the direct nursing was more prevalent on day shift and the indirect nursing was prevalent on evening shift. However, in the recovery room, both direct and indirect nursing activities were prevalent on day shift. Conclusion: The role of anesthesia and recovery room nurses was analysed according to the time, frequency, and its characteristics.

  • PDF

Design and Fabrication of Clock Recovery Module for Gap Filter of Satellite DMB (위성 DMB 중계기용 클럭 재생 모듈 설계 및 제작)

  • Hong, Soon-Young;Shin, Yeoung-Seop;Hong, Sung-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.4 s.119
    • /
    • pp.423-429
    • /
    • 2007
  • The clock recovery module of gap filler for satellite DMB is proposed. Proposed module sustains the output frequency of 10 MHz whether the received signal from the satellite is unstable or cut off within 0.5 sec. The advantages of this module is without frequency tuning at regular interval and low material cost. This module is fabricated by using CPLD as clock recovery IC and new type of loop filter for satisfying the fast lock time and long hold over time simultaneously. The measured performance of the fabricated module has a holdover time of 11 sec at frequency stability less than 0.01 ppm, and phase noise of -113 dBc/Hz at 100 Hz offset.